Datasheet E110

Robust explosion proof indicator

Flow rate Indicator / Totalizer


with analog and pulse signal outputs

Advantages Outputs
Save time and gain flexibility with the easy-to-operate through glass Isolated, loop powered 4 - 20mA output according to flow rate.
keypad: no need to remove the front cover or to arrange a work permit. S
 caled pulse output according to accumulated total.
Your crew is in control with our highly praised “know one, know them all”
configuration structure, saving time, cost and aggravation. Inputs
Easy installation with the spacious chamber and plug and play connectors. Ability to process all types of volumetric or mass flow meter signals:
Cost saving with an easy to install, 1” NPT thread for flow meter mounting. Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), Active pulse
Durable high grade stainless steel 316L Ex d enclosure for extremely salty signals, (0)4 - 20mA and 0 - 10V DC analog inputs.
atmospheres (offshore).
Key information at a glance as the display shows flow rate, total, Applications
measuring units and a flow rate indicating speedometer. Flow measurement where re-transmission of the flow rate and/or
totalizer functions or serial communication is required.
Features The E110 offers you a flow rate indicator / totalizer designed to be used
Explosion proof according ATEX, IECEx, FM and CSA c-us. in rough and tough applications, beyond being just explosion proof. Its
Easy K-factor and engineering unit configuration for volumetric or mass. sturdy design and ease of use are unequaled by any other explosion
7 digit flow rate / total and 11 digit accumulated total. proof indicator in the market! The E-Series is always your first and safest
Bright LED backlight. choice in explosion proof applications.
Power options: Loop powered, battery and 9 - 27V DC. For intrinsically safe applications we offer our field mount F-Series
Sensor supply 8.2 / 12 / 24V DC. indicators.
Data logging to survey information.
USB communication for remote configuration or local data extraction.
Modbus communication option RS232 / RS485.
Easy configurable via PC with free downloadable configuration tool.

Your first and safest choice for explosion proof indicators. Datasheet E110 -1-
High grade Stainless Steel 316L enclosure
General information
Introduction
The E110 is a popular model in our range of ­explosion proof flow
rate indicators. The E-series distinguishes itself by its quality and
functionality driven European design and ­manufacturing. It is more
than fulfilling the rules for ­explosion proof design, it is about safety
during the daily ­operation. Often, the environment is much tougher
than the ­explosion proof ­requirements demand. Thus dangerous
conditions may be experienced due to a ­broken enclosure or a
poorly made flame path. Ruggedness and reliability is where
Turbines stands for and it is now available in a comprehensive well
designed and purpose driven explosion proof flow rate indicator /
totalizer. Easy-to-operate through glass keypad

Display
The unique LCD display provides multiple flow data at a glance.
The main information is displayed with 7 digits (12mm, 0.47”) to
show total or flow rate and 11 digits (7mm, 0.28”), which can be set
to show flow rate and accumulated total. On-screen engineering
units are easily configured from a ­comprehensive selection,
while different units for flow rate and total can be displayed
simultaneously. The speedometer offers a quick impression of the
actual flow rate. For good readings in full sunlight and darkness, the
E110 is provided with a bright backlight. When battery powered the
backlight is only operational after a keypad touch, to safe battery
life. Robust entry threads

Configuration
The E-Series uses the highly appreciated configuration structure
of our F-, D- and N-Series product lines. Each setting is clearly
indicated with an alphanumerical description, which avoids
confusing abbreviations. Once familiar with one E-series product,
you will be able to program all models in all series without a
manual. For example: an (intrinsically safe) F110 operates identical
to an explosion proof E110 and has the same three buttons! In other
words: know one, know them all.

Remote configuration USB communnication for local data extraction


Even more user-friendly is the remote configuration via a PC
using the free downloadable E-Series Configuration Software.
Depending on your product, just connect the E-Series to your
PC with the ­special Configuration Cable (ACE02) or use the
Modbus or USB ­communication cables (ACE01/06/07).

Operation
Operation is done via the optical, easy-to-operate, through glass
keypad without having to remove the front cover. These optical keys
can be disabled. For easy handheld configuration there are three
mechanical push buttons on the bottom side of the display collar.
All settings are accessed via a simple operator menu that can be
passcode protected.

Your first and safest choice for explosion proof indicators. Datasheet E110 -2-
Flow meter input Hazardous areas
The E110 accepts most input signals for volume flow or mass The E-Series has been ­certified according ATEX, IECEx,
flow meters. The pulse input signal type can be selected in FM and CSA c-us with an ­ambient temperature of -40°C to +70°C
the configuration menu without having to adjust any sensitive (-40°F to +158°F).
mechanical dip-switches or jumpers. The analog input is The application range of the enclosure is very wide:
available with linear and square root calculation. The ATEX markings are:
Gas: II 2 G Ex d IIC T6 Gb
Analog output Dust: II 2 D Ex tb IIIC T85°C Db
The flow rate is transmitted with the galvanically isolated The IECEx markings are:
4 - 20mA output signal. The E110 can even be loop powered via the Gas: Ex d IIC T6 Gb
isolated loop-current. Dust: Ex tb IIIC T85°C Db
The FM and SA c-us markings are:
Pulse outputs XP (Explosion-proof ): Class I, Division 1, Grps A, B, C, D.
A scaled pulse output is available according the accumulated total. DIP (Dust-Ignition-proof ): Class II/III, Division 1, Groups E, F
The pulse length is user defined from 1msec up to 10 seconds. The and G. Class I, Zone 1, AEx d IIc T6 Gb, Zone 21, AEx tb IIIC T85°C
output can be a passive NPN signal or a mechanical relay output. Db.

Power requirements Communication


Several power inputs are possible to power the E110 and sensor. As All processed data and settings can be read and modified through
standard, the E110 can be loop powered via the isolated, two-wire, the Modbus link (RS232 / RS485) or the local USB communication
analog output. The battery powered version with a long life lithium which is located at the side entry plug. Under safe conditions, the
battery and the basic 9 - 27V DC can power the E110 including the plug can be removed for easy configuration or data log extraction.
backlight, but don’t offer a real sensor supply. A real sensor supply
of 8.2, 12 or 24V is optional available with type PD. Screenshot Remote Configuration Software

Data logging
The data log function can hold up to 2824 logs. Each log contains
the flow rate, total, acc. total, time stamp and log number.
The log interval can be user defined from every minute up to once
every 24 hours. Events like cleared total, changed menu settings or
factory reset can also be logged. Once the log is full it will roll over,
deleting the oldest data.
The log data can be visualized on the LCD but is also easy accessible
and downloadable as .CSV file via Modbus or USB communication
with our free software tool.

Enclosures Overview application E110


Two fundamental versions of our IP66/IP67, NEMA Type4X/7/9
explosion proof enclosures are available: a solid die cast aluminum
or a high grade stainless steel 316L enclosure resistant to extremely
Pulse Analog Modbus
salty atmospheres (offshore). The aluminum enclosure has an output output Communication
industrial two component coating and is better suitable for outdoor
and chemical plant applications than powder coated alternatives.
A major advantage for the installation engineer is the spacious mid- USB
Communication
chamber for the cable entry in combination with the plug-and-play
Remote control:
connectors. Especially for straight flow meter mounting a 1” NPT reset total / clear-lock
connection is available (see page 4 for available NPT and Metric
threads sizes).
Flow meter
input

Your first and safest choice for explosion proof indicators. Datasheet E110 -3-
Dimensions enclosures Terminal connections
112mm (4.41”)
Main Electronics Module
POWER
REQUIREMENTS PULSE OUTPUT

P1 P2 R1 R2 R3
PD: 9 - 27V DC OT: passive transistor output

+ +

PX: 9 - 27V DC

+
133mm (5.24”)

PB: battery powered


(PX is standard available: if supply PX/PD
is connected, the battery supply will be
switched off automatically.)

SENSOR LOOP POWERED


E-Series SENSOR INPUT SUPPLY ADDITIONAL INPUT COMMUNICATION ANALOG OUTPUT

S1 S2 S3 P3 E1 E2 C1 C2 C3 C4 A1 A2
P: coil IB: Reset total/Clear-lock CB: RS232 AH: Isolated 4 - 20mA
8.2 / 12
/ 24V
+ +
DTR
+12V RXD TXD I -/+ I -/+
P: reed switch / NPN CH: RS485 - 2 wire Note: Non-polarity
8.2 / 12 sensitive.
+ / 24V
A B
+
P: PNP CU: USB Communication
3V 8.2 / 12
148mm (5.83”) - +
/ 24V
+
Black Red White Green

P: namur
2 x Entry thread T1 3V 8.2 / 12
- +
/ 24V
+
P: active signal
3V 8.2 / 12
+ +
/ 24V
+
A: (0)4 - 20mA
8.2 / 12
I+ / 24V
+
U: 0 -10V
8.2 / 12
U+ / 24V
+

Note: The sensor supply (P3)


is only available with PD.

Supply Module
POWER
REQUIREMENTS PULSE OUTPUT

P5 P6 P7 R8 R9
PD: 9 - 27V DC* OR: Relay output*

+ COM1 NO1

PX: 9 - 27V DC*

* Type OR requires 24 - 27V DC and power supply via P5-P6,


Entry thread T2 instead of P1-P2

Enclosure types Display example - scale 1:1


Type HA_ Aluminum Ex d enclosure.
Weight 1300 gr.
Type HS_ Stainless steel 316L Ex d enclosure.
Weight 3600 gr.

Enclosure drillings
Type H_A T1: 2 x 3/4”NPT / T2: 1 x 1”NPT
Type H_B T1: 2 x 3/4”NPT / T2: 1 x 3/4”NPT
Type H_C T1: 2 x 1/2”NPT / T2: 1 x 1”NPT
Type H_D T1: 2 x 1/2”NPT / T2: 1 x 3/4”NPT
Type H_G T1: 2 x M20 / T2: 1 x M25
Type H_H T1: 2 x M25 / T2: 1x M25

Your first and safest choice for explosion proof indicators. Datasheet E110 -4-
Typical wiring diagram E110-A-AH-CB-IB-OR-PD Typical wiring diagram E110-P-AH-CH-IB-OT-PX

TERMINAL CONNECTORS
TERMINAL CONNECTORS
9 - 27V DC9 POWER
- 27V DCREQUIREMENT
POWER REQUIREMENT TERMINAL CONNECTORS
TERMINAL CONNECTORS
OUTPUT LOOP
OUTPUT
POWERED
LOOP POWERED
Main Electronics
MainModule
Electronics Module Main Electronics
MainModule
Electronics Module
E-series E-series e.g. indicatore.g. indicator E-series E-series e.g. indicatore.g. indicator
+ + + +
A2

A2

A2

A2
Analog output
Analog
type AH:
output
(loop
typepowered)
AH: (loop 11
powered)
- 27V DC 11 - 27V DC Analog output
Analog
type AH:
output
(loop
typepowered)
AH: (loop powered)
11 - 27V DC 11 - 27V DC
Galvanically Galvanically
isolated 4 - 20mA
isolated 4 - 20mA Galvanically Galvanically
isolated 4 - 20mA
isolated 4 - 20mA
- - - -
A1

A1

A1

A1
Power Power Power Power
supply supply supply supply

B B
C4

C4

C4

C4
TXD TXD

A A
C3

C3

C3

C3
RXD RXD
Modbus communication
Modbus communication
type CH: RS485
type- CH:
2 wire
RS485 - 2 wire
C2

C2

C2

C2
DTR DTR Modbus communication
Modbus communication
type CB: RS232
type CB: RS232
12V 12V
Common ground
Common ground Common ground
Common ground
C1

C1

C1

C1
+ 3V + 3V + 3V + 3V
low-pass low-pass low-pass low-pass
filter filter Additional input
Additional input filter filter Additional input
Additional input
E2

E2

E2

E2
Type IB: Type IB: Type IB: Type IB:
Reset total /Reset
Clear-lock
total / Clear-lock Reset total /Reset
Clear-lock
total / Clear-lock
Common ground
Common ground Common ground
Common ground
E1

E1

E1

E1
Supply * Supply * Supply * Supply *

P3

P3
P3

P3

Circuit depends on

Circuit depends on
Supply * Supply *
type of signal

S2 of signal
S3

S3
Signal Signal Signal Signal Flow meter input
Flow meter input
Flow meter input
Flow type
meterA:input type A: type: P type: P
type

(0)4 - 20mA (0)4 - 20mA

S2
S2

S2

pulse pulse

Common ground
Common ground Common ground
Common ground
S1

S1
S1

S1

Pulse outputPulse
type OT:
output type OT:
Common ground
Common ground passive transistor,
passive transistor, Common ground
Common ground
R3

R3

R3

R3

remains available
remains
with
available
type OR**
with type OR**

123456
123456 + +
123456
123456 + +
Pulse outputPulse
type OT:
output type OT:
R2

R2

R2

R2

e.g. counter e.g.


output
counter output e.g. counter e.g.
output
counter output passive transistor
passive transistor
- - - -
Common ground
Common ground Common ground
Common ground
R1

R1

R1

R1

Power supplyPower
type PX:
supply type PX:
P2

P2

P2

P2

Main supply Main supply Main supply Main supply 9 - 27V DC 9 - 27V DC
(not used in (not
this example)
used in this example)
Common ground
Common ground Common ground
Common ground
P1

P1

P1

P1

TERMINAL CONNECTORS
TERMINAL CONNECTORS TERMINAL CONNECTORS
TERMINAL CONNECTORS
Supply Module
Supply Module Supply Module
Supply Module
E-series E-series E-series E-series

123456
123456 + +
Pulse outputPulse
type OR:
output type OR: Pulse outputPulse
type OR:
output type OR:
R9

R9

R9

R9

e.g. counter e.g.


output
counter output
- mechanical relay**
- mechanical relay** mechanical relay
mechanical relay
(not used in (not
this example)
used in this example)
R8

R8

R8

R8
P7

P7

P7

P7

+ +
Power supplyPower
type PX:
supply type PX:
P6

P6

P6

P6

Main supply Main supply Power supplyPower


type PD:
supply type PD:9 - 27V DC 9 - 27V DC Main supply Main supply 9 - 27V DC 9 - 27V DC
9 - 27V DC 9 - 27V DC (not used in (not
this example)
used in this example)
- -
Common ground
Common ground Common ground
Common ground
P5

P5

P5

P5

Earth Earth

* Supply voltage
* Supply
P3: 8.2
voltage
/ 12 /P3:
24V8.2
DC/ to
12 sensor
/ 24V DC to sensor *Supply voltage
*Supply
S3: 3V
voltage
DC toS3:
sensor
3V DC to sensor
** Type OR requires
** Type OR
24 -requires
27V DC and
24 - power
27V DCsupplied
and power
via supplied
P5-P6, instead
via P5-P6,
of P1-P2
instead of P1-P2

Your first and safest choice for explosion proof indicators. Datasheet E110 -5-
Technical specification Directives & Standards
General EMC Directive 2014/30/EU, FCC 47 CFR part 15.
Display Low voltage Directive 2014/35/EU.
Type High intensity transflective numeric and alpha- RoHS Directive 2011/65/EU.
numeric LCD, UV-resistant, with bright backlight. ATEX / IECEx Directive 2014/34/EU, IEC 60079-0, IEC 60079-1,
Intensity can be adjusted via the keypad. IEC 60079-31.
Note When battery powered, the backlight is only FM Class 3600, 3615, 3616, 3810.
operational after a keypad touch to extend the
CSA CSA 22.2 No. 25, No. 30, No. 61010-1-12.
battery lifetime.
UL UL 61010-1.
Dimensions Ø 65 x 45mm (2.56” x 1.77”).
Digits Seven 12mm (0.47”) and eleven 7mm (0.28”) digits. IP & NEMA EN 60529 & NEMA 250.
Various symbols and measuring units.
Refresh rate User definable: 8 times/sec. - 30 secs. Hazardous area
Speedometer To indicate the actual flow rate the bargraph runs Explosion proof
from 0 to 100% in 20 blocks, each block is 5%. Ambient Ta -40°C to +70°C (-40°F to +158°F).
ATEX Gas:  II 2 G Ex d IIC T6 Gb.
Operating temperature certification Dust: II 2 D Ex tb IIIC T85°C Db.
Ambient -40°C to +70°C (-40°F to +158°F). IECEx Gas: Ex d IIC T6 Gb.
certification Dust: Ex tb IIIC T85°C Db.
Power requirements FM & CSA c-us Class I, Div. 1, Grps A, B, C, D.
Type PB Long life Lithium battery - life-time depends upon certification Class II/III, Div. 1, Grps E, F, & G.
settings and configuration - up to approx. 3 years. Class I, Zone 1, AEx d IIc T6 Gb,
Note PB The battery can power the backlight for a short time
Zone 21, AEx tb IIIC T85°C Db.
after a keypad touch but cannot power the relay
output (OR) or the real sensor supply (Terminal P3). Enclosure
Type PD 9 - 27V DC. Consumption max. 4.5W General
Type PX 9 - 27V DC. Consumption max. 3W. Window Glass window.
Type AH Loop powered, analog output. 11 - 27V DC, Sealing Silicone.
Min. 3.5mA. Consumption max. 675mW (25mA @ 27VDC). Control keys Three infra-red keys with operation through the
Note AH The loop powered analog output cannot power the glass front window.
backlight, mechanical relay output (OR) or the real Rating IP66, IP67 / NEMA Type4X / Type7 / Type9.
sensor supply (Terminal P3). Dimensions 112 x 133 x 148mm (4.41” x 5.24” x 5.83”) - W x H x D.

Sensor excitation Enclosure types


Type AH/PB/PX Terminal S3: 3V DC for pulse signals and 1.2V DC for Type HA_ Aluminum Ex d enclosure.
coil pick-up, Iout max. 100μA. Weight 1550 gr. (3.41 lbs).
Note This is not a real sensor supply. Only suitable for Type HS_ Stainless steel 316L Ex d enclosure.
sensors with a very low power consumption like coils Weight 3600 gr. (9.65 lbs).
(sine wave) and reed-switches.
Type PD Terminal P3: 8.2 / 12 / 24V DC Enclosure drillings
8.2V DC, Iout max. 20mA. Type H_A Entry threads: 2 x 3/4”NPT / 1 x 1”NPT
12V DC, Iout max. 30mA. Type H_B Entry threads: 3 x 3/4”NPT
24V DC, Iout max. 75mA (this voltage varies Type H_C Entry threads: 2 x 1/2”NPT / 1 x 1”NPT
depending on the input supply voltage) Type H_D Entry threads: 2 x 1/2”NPT / 1 x 3/4”NPT
Type H_G Entry threads: 2 x M20 / 1 x M25
Terminal connections Type H_H Entry threads: 3 x M25
Type Removable plug-in terminal strip.
Wire max. 1.5mm2 and 2.5mm2. Accessories
General E-Series accessories
Data protection
ACE01 USB data logging and configuration cable for type CU.
Type EEPROM backup of all settings. Backup of running
ACE02 Remote configuration cable for type CX.
totals every minute. Data retention at least 10 years.
ACE03 Stainless steel wall mounting kit (inc. screws+plugs).
Pass-code Configuration settings can be pass-code protected.
ACE04 Stainless steel pipe mounting kit.
ACE05 2 pins, 30cm (12”) cable with Amphenol connector.
ACE06 Remote configuration cable (1.8m/5.9ft) for type CH.
ACE07 Remote configuration cable (1.8m/5.9ft) for type CB.

Your first and safest choice for explosion proof indicators. Datasheet E110 -6-
Signal input Communication option
Flow meter sensor Function Reading display information, reading / writing all
Type P Coil / sine wave (COIL-HI: 20mVpp or COIL-LO: configuration settings and data log extraction.
90mVpp sensitivity selectable), NPN, PNP, Protocol Modbus ASCII / RTU.
reedswitch, Namur, active pulse signals 8 or 24V DC. Type CB RS232
Frequency Minimum 0Hz - maximum 10kHz for total and flow Type CH RS485 2-wire
rate. Maximum frequency depends on signal type Type CU Local USB communication for connection to a PC /
and internal low-pass filter. E.g. reed switch with laptop incl. Ex d USB plug at the right-hand side entry.
low-pass filter: max. frequency 120Hz. Restriction CU Requires 3/4”NPT or M25 side entry thread.
K-Factor 0.000010 - 9,999,999 with variable decimal position. Type CX No communication, remote configuration possible
Low-pass filter Available for all pulse signals. with accessory cable ACE02.
Option ZF Coil sensitivity 10mVpp. Operational
Option ZG Coil sensitivity 5mVpp. Operator functions
Type A (0)4 - 20mA. Analog input signal can be Displayed • Flow rate and / or total.
scaled to any desired range within 0 - 20mA. functions • Total and accumulated total.
Type U 0 - 10V DC. Analog input signal can be • Indicating speedometer for flow rate.
scaled to any desired range within 0 - 10V DC. • Reset total by pressing the CLEAR-key twice.
Accuracy 16 bit. Low level cut-off programmable.
Type A: Error 0.03% @ 20°C (Typical 30ppm/°C). Remote configuration
Type U: Error 0.03% @ 20°C (Typical 45ppm/°C). Function Easy remote configuration via our free downloadable
Span 0.001 / 9,999,999 with variable decimal position. software and a special communication cable.
Update time Two times per second. Type CB Requires ACE07 cable with RS232 to USB plug.
Voltage drop Type A: max. 1V DC @ 20mA. Type CH Requires ACE06 cable with RS485 to USB plug.
Load impedance Type U: 3kOhm. Type CU Requires ACE01 cable with mini USB to USB plug.
Relationship Linear and square root calculation. Type CX Requires ACE02 cable for option CX to USB plug.
Note For signal type A and U: external power to sensor is
required; e.g. type PD. Data logging
Function Records process data over time with real time clock.
Type ZL Each log containing flowrate, total, acc. total,
Additional input signal time/date stamp and log number, requires Type P.
Function Terminal input to reset total remotely or to lock the Interval logs Every: 1 min, 5 min, 10 min, 15 min, 30 min, 1 hr,
“clear total” button. 2 hr, 3 hr, 4 hr, 6 hr, 8 hr or disable.
Type IB Internally pulled-up switch contact - NPN. Max. 1500 interval logs
Duration Minimum pulse duration 100msec. Daily logs Configurable time once / twice per day or disable.
Max. 600 daily logs.
Event logs When settings change (manual/Modbus), restart /
Signal outputs
power failure, factory reset, cleared total or error event.
Digital output
Max. 724 event logs.
Function Pulse output: Transmitting accumulated total.
Extraction Via USB (CU) or Modbus communication (CB/CH) as .csv
Frequency Max. 500Hz. Pulse length user definable between
1msec up to 10 seconds.
Total
Type OR One isolated electro-mechanical relay output (NO).
Digits 7 digits.
Maximum resistive load: 2A @ 250V AC / 30V DC.
Units L, m3, US gal, igal, cf, Oil bbl, kg, ton, US ton,
Maximum inductive load: 0,5A (pilot duty applications).
lb or none.
Type OT remains also available.
Decimals 0 - 1 - 2 or 3.
Restrictions OR Requires 24 - 27V DC and supplied via P5 - P6.
Note Total can be reset to zero.
Frequency max. 5Hz.
Type OT One passive transistor output (NPN) - not isolated.
Accumulated total
300mA - 50V @ 25°C.
Digits 11 digits.
Units / decimals According to selection for total.
Analog output
Note Can not be reset to zero.
Function Transmitting flow rate.
Type AH Galvanically isolated, loop powered 4 - 20mA output
Flow rate
Accuracy 12 bit. Error 0.03% @ 20°C (Typical 45ppm/°C).
Digits 7 digits.
Output signal can be scaled to any desired range.
Units mL, L, m3, mg, g, kg, ton, US ton, US gal, igal, Oil bbl,
lb, cf, rev, none, scf, nm3, nL or p.
Decimals 0 - 1 - 2 or 3.
Time units /sec - /min - /hr - /day.

Your first and safest choice for explosion proof indicators. Datasheet E110 -7-
Datasheet E110
Robust explosion proof indicator

Ordering information (in aphabetical order)


Standard configuration: E110-P-AH-CX-HAA-IB-OT-PX-XD-ZB.
Ordering information: E110 -_ -AH -C _ -H _ _ -IB -O_ -P _ -XD -Z _
Flow meter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AH Galvanically isolated, loop powered 4 - 20mA output.
Communication
CB RS232 communication - Modbus ASCII / RTU.
CH RS485 communication - 2wire - Modbus ASCII / RTU.
CU USB communication incl. Ex d plug - requires 3/4”NPT or M25 entry thread.
CX No communication, remote configuration is possible with accessory ACE02.
Enclosure types - IP66,IP67 / NEMA Type4X / Type7 / Type9.
HA_ Die-cast aluminum Ex d enclosure.
HS_ Stainless steel 316L Ex d enclosure.
Enclosure drillings
H_A Entry threads: 2 x 3/4”NPT / 1 x 1”NPT.
H_B Entry threads: 3 x 3/4”NPT.
H_C Entry threads: 2 x 1/2”NPT / 1 x 1”NPT.
H_D Entry threads: 2 x 1/2”NPT / 1 x 3/4”NPT.
H_G Entry threads: 2 x M20 / 1 x M25.
H_H Entry threads: 3 x M25.
Additional input signal
IB Remote control input to reset total or to lock the “clear total” button.
Digital output signal
OR Mechanical relay output (OT remains available) - requires 24 - 27V DC.
OT Passive transistor output - standard configuration.
Power requirements
PD 9 - 27V DC + sensor supply.
PX Basic power input 9 - 27V DC (no real sensor supply).
Additional battery supply (optional)
PB Lithium battery powered.
Hazardous area
XD Explosion proof enclosure according ATEX, IECEx, FM and CSA c-us.
Other options
ZB Backlight is included as standard.
ZF Coil input 10mVpp.
ZG Coil input 5mVpp.
ZL Data logging to survey information - requires Type P.
ZM Extra manual in “DE-German” and/or “ES-Spanish”. English and French manuals are included as standard.
The bold marked text contains the standard configuration.

Turbines Incorporated
Telephone: 800-809-1387
Internet: www.turbinesincorporated.com Important: Specifications are subject to change without notice.
Copyright: Fluidwell bv - 2017 - E110TURBINES-DATA-EN-V1727