X-CUBE 70 Ultrasound System specifications

ALPINION MEDICAL SYSTEMS CO., LTD


X-CUBE 70 Ultrasound System General Specification
Physical Specification
• Width: 580 mm
• Depth: 835 mm
• Height: 1,440 - 1,605 mm
• Weight: approx. 85 kg (System only)

Electrical Specification
• 100 - 120 V, 200 - 240 V, 50/60 Hz
• Power consumption: Max. 700 VA
• Battery (Option): Max. 22 hours (in Sleep mode)

System Design
• 23” flat panel monitor and articulated arm
• Electric motorized control panel adjustment
– Range of height: 165 mm
– Left/right swivel: ±30°
• Front and rear handle
• 4 active transducer ports
• 1 parking transducer port
• 1 pencil transducer port
• Transducer holders
• Gel warmer (3 temperature levels)
– Low: 30° C
– Medium: 34° C
– High: 38° C
• 4 swivel wheels
Product Description • Locking mechanism
– Front wheels: Swivel & Brake Lock
X-CUBE 70 is a high-performing diagnostic ultrasound – Rear wheels: Swivel Lock
system that provides diagnostic confidence and user
• Integrated SSD
convenience with a vast range of convenient features
and superior image quality. • ECG (Option)
• Thermal printer storage
• Built-in stereo speaker
System Architecture • Built-in cable management
• X Architecture
+ • System boot-up
• X+ FIT – from off: approx. 62 sec
• X+ Crystal Signature™ – from Sleep mode to on: approx. 7 sec
• SensitiView™ Technology
• MicroFit™ Technology Computing power
• Windows10 Embedded • Main processor: Intel core i5-8400H 2.5 GHz
• Main memory: 16GB
• SSD[250GB] and HDD[1TB]

2/16 X-CUBE 70_Product Specificati


User Interface Operating Modes
• 2D mode
Control Panel • Harmonic mode (HAR)
• Alphanumeric keyboard with backlit • M mode
• Ergonomic key layout • Color M mode
• 8 TGC control levers • Anatomical M mode (AMM)
• 13 user customizable keys • Color Flow Doppler (CF) mode
• Power Doppler (PD) mode
Touch Screen • Directional PD mode
• Pulsed Wave Doppler (PWD) mode
• 12.1” high definition LED backlit LCD
• Continuous Wave Doppler (CWD) mode
• Resolution: 1,280 X 800
• High PRF Doppler mode
• 16.7M color display
• Tissue Doppler Imaging (TDI) mode
• Brightness and contrast adjustable (OSD)
• 3D/4D mode
• Adjustable screen angle: Up to 15°
• Contrast Enhanced Imaging (CEUS) mode
• Strain Elastography
Main Monitor
• Point Shear Wave Elastography (pSWE)
• 23” high definition LED backlit LCD • Micro View Imaging mode
• Resolution: 1,920 x 1,080 (16:9 wide) • Panoramic mode
• 16.7M color display
• Contrast: 1:1,000 Complex Modes
• IPS (In Plane Switching) technology
• Duplex: B+B, B+PW, B+CW, B+CF, B+PD, B+DPDI,
• Brightness and contrast adjustable
B+M, B+3D, B+4D, B+Live HQ, A+B+C+3D, A+B+C+4D,
• Articulated monitor arm B+Elastography
– Up/down: 145 mm • Triplex: B+CF+PW, B+CF+CW, B+CF+M
– Swivel: +/- 90°
– Tilt: +15° / -90° Imaging Presentation
• Dual
• Live Dual
System Overview • Quad
• Duplex Image Format
Applications
– 1:1/1:2/1:3/3:1/2:1/Full format
• Abdomen • Image Reverse: Left/Right
• Obstetrics (OB) • Image Rotation: 0°, 90°, 180°, 270°
• Gynecology (GYN) • Full screen mode
• Cardiology
• Small Parts Transducer Types
• Musculoskeletal (MSK)
• Pencil Doppler
• Vascular
• Linear Array
• Urology
• Sector Phased Array
• Emergency Medicine (EM)
• Convex Array
• TCD
• Endocavity
• Breast
• Volume Transducer
• Appendix
– Volume Convex
– Volume Endocavity

X-CUBE 70_Product Specificati 3/16


System Standard Features • X+ Volume Advance
• Cube Note
• 5 Transducer ports
• AutoEF
• Full Speckle Reduction Imaging (Full SRI)
• STIC (Ship-hold)
• Spatial Compounding Imaging (SCI)
• CEUS
• FTHI (Filtered Tissue Harmonic)
• Silhouette View
• PTHI (Pulse Inversion Tissue Harmonic)
• STL 3D Printing
• Xpeed
• X+ MicroView
• Virtual Convex
• X+ pSWE
• EX-FOV (Extended View)
• X+ Assistant
• Raw Data Processing
• X+ Auto Biometry
• Post Processing
• Measurement Package
Peripheral Options
Including worksheets/reports for:
• External USB DVD-RW
– Abdomen
– Hitachi-LG Data Storage, Inc
– OB
GP65NB60
– GYN
• USB thermal B&W printer
– Cardiology
– Sony Corporation
– Vascular UP-D897, UP-897MD, UP-D898MD, UP-X898MD,
– Urology UP-D25MD, UP-25MD
– Pediatrics • USB thermal color printer
– Small Parts – Sony Corporation
– Breast UP-D25MD, UP-25MD
– MSK • Wireless LAN
– EM • Tri-pedal footswitch, with programmable functionality
• Side tray
System Options • Endocavity transducer holder

• CV M&R
Display Annotation
• DICOM 3.0 Connectivity
• DICOM SR (OB) • Patient ID: Up to 64 characters
• DICOM SR (Adult Echo) • Patient name: First, last and middle
• DICOM SR (Vascular) • Gender, age and birth date
• DICOM Query • Gestational age from LMP, EDD and GA
• Auto IMT • Transducer name
• CW • Institution / hospital name: up to 25 characters
• Anatomical-M • Date format: 3 types
• Panoramic – YYYY/MM/DD
• Tissue Doppler Image – MM/DD/YYYY
• Stress Echo – DD/MM/YYYY
• Cube Strain™ • Time format: 2 types
• Live HQ™ – 12 hours / 24 hours
• Elastography • Acoustic power
• Cube View™ – Mechanical index (MI)
• Needle Vision™ Plus – Thermal index (TI): TIS, TIB, TIC
• Auto NT • Transducer name
• X 3D4D
+ • Preset

4/16 X-CUBE 70_Product Specificati


• Transducer orientation – Full SRI
• Depth – Edge Enhance
• Focus – Reject
• TGC line • M
• Frequency – Colorize
• Frame rate – Dynamic Range
• Power – Gain
• Mode name – Gray Map
• Gray scale bar – Reject
• Arrow – Sweep Speed
• Indicator • PWD
• Text – Gain
– Size: 1 - 10 – Auto Calc.
• Body pattern – Baseline
– 201 sets – Sweep Speed
– Size: small, medium, large – Invert
• Biopsy guideline – Colorize
• ECG and Respiration line – Gray Map
• Thumbnail – Auto Angle
• Stored image info – Angle Correct
• Cine gauge – Reject
• Measurement result – Dynamic Range
• Trackball controls and status • CWD
– Angle Correct
– Auto Calc.
System Parameters – Baseline
– Colorize
System Presets – Dynamic Range
– Gray Map
• User Programmable Preset Capability
– Reject
• Factory Default Preset Data
– Sweep Speed
• Languages: English, German, Spanish, French, Italian,
Portuguese, Russian, Chinese • CF/PD
• Programmable Annotation Library – Baseline
• Body Patterns – Blend / Adaptive Blend
– Colorize
Controls Available on Freeze (Post-Processing) – Color Map
– Invert (CF / DPDI)
• Read Zoom
– Threshold
• 2D
• PD
– Zoom
– Baseline
– Reverse
– Blend / Adaptive Blend
– Gain
– Colorize
– Dynamic Range
– Color Map
– Up/Down
– Invert (CF / DPDI)
– Colorize
– Threshold
– Gray Map

X-CUBE 70_Product Specificati 5/16


Controls Available while Live (Pre-Processing) – Baseline
– Dynamic Range
• Write Zoom
– Gray Map
• 2D
– Gain
– Angle Steer
– Scale (PRF)
– Colorize
– Frequency
– Dynamic Range
– Power
– Edge Enhance
– Reject
– Frequency
– Sound
– Full SRI
– Sweep Speed
– Gray Map
– Wall Filter
– Gain
• CF/PD
– Harmonic
– Angle Steer
– Pulse inversion harmonic
– Baseline
– Invert
– Color Map
– Line Density
– Ensemble
– Persist
– Frequency
– Power
– Flow State
– Reject
– Gain
– Spatial Compound
– Line Density
• M
– Power
– Anatomical M
– Scale (PRF)
– AMM Angle
– Smooth
– Colorize
– Wall Filter
– Dynamic Range
– Gray Map
• PWD
– Angle Image Processing and Presentation
– Angle Steer • System Frequency Range: 1 - 20 MHz
– Auto Angle • System processing channel: 7,645,867
– Baseline • ADC: 14 bits
– Colorize • Displayed Imaging Depth: 0 - 40 cm
– Dynamic Range • Max. Frame Rate (Transducer dependent)
– Frequency – 2D: 509 (Hz/FPS)
– Gray Map – Color: 270 (Hz/FPS)
– Gain – PW: 299 (Hz/FPS)
– Line Density – Volume Convex: 17 (Hz/VPS)
– Power – Volume Endocavity: 100 (Hz/VPS)
– Reject • Gray Scale: 256 levels
– Scale (PRF) • Dynamic Range: Max. 250 dB
– SV Size • Max. Scan line: 1,024
– Sweep Speed • Adjustable Field of View (FOV)
– Sound • Image Reverse: Right/ Left
– Wall Filter • Image Rotation: 0°, 90°, 180°, 270°
• CWD • Focus
– Angle – Focal number: Max. 8

6/16 X-CUBE 70_Product Specificati


– Focal position: Max. 19 • DICOM Print
• Zoom • DICOM Storage commitment
– Write Zoom: Max. 11.9x (Transducer dependent) • DICOM Media
– Read Zoom: Max. 10x • DICOM Worklist
• CF (Transducer dependent) • DICOM MPPS
– 300 Hz - 13.1 KHz • DICOM Q&R
– 2 cm/s - 423.9 cm/s • DICOM Structured Report (OB-GYN)
• PW (Transducer dependent) • DICOM Structured Report (Echocardiography)
– 300 Hz - 25 kHz • DICOM Structured Report (Vascular)
– 2.3cm/s - 1000 cm/s • Cube View™
• CW • Cube Note
– 1.6 KHz - 78.1 KHz • Network Storage
– 2.5 cm/s - 30.8 m/s • Wireless LAN (Option)

CINE Memory
• Cine memory: 716 MB, 16,384 frames, 312 volumes Scanning Parameters
• Prospective and retrospective
• Cine review, save and edit
2D Mode
• Run, stop, frame move • Angle Steer (Transducer dependent): 7 steps (-15 - 15°)
• Play speed: 50% 100%, 200%, 300%, 400%, 500%, 600%, • Colorize: 0 - 6
700%, 800%, 900%, 100% • Dynamic Range: 30 - 250 dB
• Edge Enhance: 0 - 10
Image Archive • Frequency
• Clipboard: Displays thumbnail images of the acquired • Full SRI: 0 - 5
data for the current exam • Gray Map: 0 - 8
• Previewing Clipboard Images: An enlarged preview of • Gain: 0 - 100
the image • Harmonic
• Recalling Images from the Clipboard • Pulse inversion harmonic
• E-View™: Archived images from the past patient exams • Line Density: 0 - 5
appear as well as images stored for the current exam • Persist: 0 - 4
• 916GB of the 1TB internal hard drive reserved for • Power: 1 - 100 %
patient data
• Reject: 0 - 6
• Image store
• Spatial Compound: 0 - 3
– Up to 916,000 images (with JPG compression)
• Image format
M Mode
– BMP, JPEG, DICOM, AVI, MPEG
• Export / Backup / Restore • Anatomical M: On / Off
• DVR • AMM Angle
– VCR: VCR/DVR, USB storage • Colorize: 0 - 6
– VCR Format: NTSC or PAL, MPEG or AVI • Dynamic Range: 30 - 150 dB
– VCR Maximum Time (min.): 1 to 20 (Only available • Gray Map: 0 - 6
for USB storage.) • Gain: 0 - 100
• Reject: 0 - 10
Connectivity • Power: 1 - 100 %

• Verification • Sweep Speed: 0 - 7

• DICOM Storage

X-CUBE 70_Product Specificati 7/16


PWD Mode • Power: 1 - 100 %
• Scale (PRF): 0.3 - 12.1 KHz (Transducer dependent)
• Angle: -89° - 89°
• Smooth: 0 - 10
• Angle Steer (Transducer dependent): 7 steps (-20 - 20°)
• Wall Filter: 0 - 7
• Auto Angle
• Baseline: -8 - 8
3D/4D Mode (X+ 3D4D)
• Colorize: 0 - 44
• Dynamic Range: 30 - 120 dB • Quality: Low, Mid, H1, H2, Max
• Frequency • Volume Angle
• Gray Map: 0 - 13 – Volume Convex: 15 - 80 (5 steps)
• Gain: 0 - 100 – Volume Endocavity: 10 - 95 (5 steps)
• Power: 1 - 100 % • Curved ROI
• Reject: 0 - 10 • Render Direction: Up, Down, Lt, Rt, Front, Back
• Scale (PRF): 0.3 - 25.7 KHz (Transducer dependent) • Brightness: 1 - 100
• SV Size: 5 - 11 mm • Contrast: 1 - 100
• Sweep Speed: 0 - 7 • Threshold: 0 - 255
• Sound: 0 - 100% • Opacity: 0 - 255
• Wall Filter: 0 - 7 • Smooth: 0 - 20
• Invert • 3D SRI: 0 - 5
• 2D SRI: 0 - 5
CWD Mode • ColorMap
– Gray map: 0 - 8
• Angle: -89° - 89°
– 2D Colorize: 0 - 6
• Baseline: -8 - 8
– 3D Color Map: 1 - 18
• Dynamic Range: 30 - 120 dB
• Gray Map: 0 - 9
3D/4D Aquisition Mode
• Colorize: 0 - 44
• Gain: 0 - 100 • STIC (Ship-hold)
• Scale (PRF): 0.3 - 78.1 KHz (Transducer dependent) – Acq. Time: 7 - 15 sec
• Frequency – Volume Angle: 15, 20, 25, 30, 35, 40, 45, 50
• Power: 1 - 100 %
• Reject: 0 - 10 3D/4D Visualization Mode
• Sound: 0 - 100 % • MPR
• Sweep Speed: 0 - 7 – Display format
• Wall Filter: 0 - 7 – Ref. Plane
• Invert – 3D Orientation
– Edit ROI
CF/PD Mode – Render Setup: Surface, Depth, Max, Min, XRay,
Light, Light2
• Angle Steer (Transducer dependent): 7 steps (-20 - 20°)
– Alpha Mode: 1, 2
• Baseline: -100 - 100
– Cine
• Color Map: 0 - 26 (CF), 0 - 8 (PD), 0 - 9 (DPDI)
– Cine Calc.
• Ensemble: 6 - 16
– Initial
• Frequency
– Easy Cut
• Flow State: Low, Mid, High
– Clear Face
• Gain: 0 - 100
– 3D Print
• Line Density: 0 - 3
• Silhouette: On / Off

8/16 X-CUBE 70_Product Specificati


• Sectional Planes • Light Direction
– Multi Plane • Move Light
– Cubic View: Mode1, Mode2 • Color Map: 1 - 12
– AnySlice • Value: 0 - 100
• Multi Slice • Transparency: 0 - 100
– Display format: 1*1 / 1*2 / 2*2 / 3*3 / 4*4
– Ref. plane Panoramic Imaging
– Active view
• Colorize: 0 - 6
– Guide view
• Dynamic Range: 30 - 250 dB
– Pitch: 1 - 10 mm
• Edge Enhance: 0 - 4
– Prev. / Next
• Frequency
– Oblique Angle: -90 - 90°
• Full SRI: 0 - 5
– Thinkness: 0 - 20 mm
• Gray Map: 0 - 6
– Slice Thickness: 2 mm, 5 mm, 8 mm, 12 mm, 20 mm
• Gain: 0 - 100
• AnySlice
• Harmonic
– Display format
• Pulse inversion harmonics
– Reference line (Ref. Line)
• Line Density: 0 - 5
– Delete / Delete All
• Persist: 0 - 4
– Thinkness: 0 - 20 mm
• Power: 1 - 100%
– Slice Thickness: 2 mm, 5 mm, 8 mm, 12 mm, 20 mm
• Reject: 0 - 6
• VOCAL
– Segment Mode: Sphere, Manual, Auto
Strain Elastography
– Structure: Hypo, Hyper
– Segment Angle: 10° / 15° / 30° • Live Dual: On / Off
– Frame • Invert: On / Off
– Sphere Size • Persist: 0 - 5
– Render Type: Wire, Surface, Volume • Opacity: 10 - 100
– Shell Type: Off / In / Out / In-Out • Color Map: 0 - 5
– Rotate X / Rotate Y / Rotate Z
– 3D Color Map: 1 - 18 point Shear Wave Elastography
– Shell Thickness: 1.0 - 20.0 mm • pSWE Units: kPa, m/s
• 12 samples (S1 - S12)
3D/4D Live HQ™
• Live HQ Setup Needle Vision™ Plus
• Light Direction • L/R Flip
• Move Light • Angle: Shallow, Medium, Steep
• Live HQ color map: 1 - 12
• HQ Scatter: 0 - 10 Contrast Enhanced Ultrasound Imaging (CEUS)
• Front Scale: 0 - 20
• Live Dual: On / Off
• Back Scale: -20 - 25
• Side Control: CEUS, Tissue
• Flash: On / Off
3D/4D Silhouette
• Timer: On / Off
• Silhouette1, Silhouette2 • Line Density: 0 - 5
• Mix: 0 - 100 • Edge Enhance: 0 - 10
• Level: -100 - 100 • Sepia: On / Off

X-CUBE 70_Product Specificati 9/16


• Rotation: 0°, 180° • Field of view: 25.0 mm
• Dynamic Range: 30 - 250 dB • Elements: 192
• Sepia Map: 0 - 4 • Footprint: 32.8 X 6.8 mm
• Output Power: -20 - 0 dB • Application: EM, MSK, Vascular, Small Parts
• Flash Frame: 1 - 100 • Biopsy is not available
• Frequency • Seamless window
• Persist: 0 - 4
• Reject: 0 - 10 SL3-19H
• Transducer type: Linear
• Frequency: 3.0 - 19.0 MHz
Transducers • Field of view: 38.4 mm
• Elements: 192
SC1-7H • Footprint: 43.3 X 8.3 mm
• Transducer type: Convex • Application: Abdomen, Pediatric, Gynecology,
• Frequency: 1.0 - 7.0 MHz Obstetrics, EM, MSK, Vascular, Small Parts, TCD
• Field of view: 60° • L3-12 Biopsy Starter Kit
• Elements: 192 • X+ Crystal Signature
• Radius of curvature: 60 mm • Seamless window
• Footprint: 72.4 X 16.8 mm
• Application: Abdomen, EM, Gynecology, Obstetrics, MP1-5X
Pediatric, Urology
• Transducer type: Sector Phased
• SC1-6 Biopsy Starter Kit
• Frequency: 1.0 - 5.0 MHz
• X+ Crystal Signature
• Field of view: 90°
• Elements: 80
L3-12X • Footprint: 23.0 X 15.4 mm
• Transducer type: Linear • Application: Abdomen, Pediatric, Cardiac, EM, TCD
• Frequency: 3.0 - 12.0 MHz • Biopsy is not available
• Field of view: 51.2 mm • X+ Crystal Signature
• Elements: 256
• Footprint: 58.2 X 10.4 mm EC2-11H/EV2-11H
• Application: Pediatric, EM, MSK, Vascular, Small Parts
• Transducer type: Endocavity
• L3-12X Biopsy Starter Kit
• Frequency: 2.0 - 11.0 MHz
• Field of view: 200° (Max. 230°)
L3-15H • Elements: 192
• Transducer type: Linear • Footprint: 19.0 X 17.4 mm
• Frequency: 3.0 - 15.0 MHz • Application: Gynecology, Obstetrics, Urology, EM
• Elements: 192 • EV2-11H Reusable Starter Kit
• Footprint: 45.2 X 8.3 mm • X+ Crystal Signature
• Application: EM, MSK, Vascular, Small Parts
• L3-12 Biopsy Starter Kit SVC1-8H
• Transducer type: Volume Convex
L10-25H • Frequency: 1.0 - 8.0 MHz
• Transducer type: Linear • Field of view: 79°
• Frequency: 10.0 - 25.0 MHz • Radius of curvature: 39 mm

10/16 X-CUBE 70_Product Specificati


• Elements: 192 • Auto Trace
• Footprint: 58.64 X 38.58 mm • VTI
• Application: Abdomen, Gynecology, Obstetrics,
Pediatric, Urology, EM Abdomen Measurement
• Biopsy is not available
• Aorta
• Seamless window
• Renal
• Renal A
VE3-10H
• Renal V
• Transducer type: Volume Endocavity • Hepatic A
• Frequency: 3.0 - 10.0 MHz • IVC
• Field of view: 152° • Hepatic V
• Radius of curvature: 10 mm • Mid HV
• Elements: 192 • MPV
• Footprint: 25.1 X 25.1 mm • Portal V
• Application: Gynecology, Obstetrics, Urology, EM • Splenic A
• VE3-10H Disposable Starter Kit • Splenic V
• VE3-10H Reusable Starter Kit • SMA
• SMV
CW2.0 • IMA
• Transducer type: Pencil Doppler • Iliac A
• Frequency: 2.0 MHz • Iliac V
• Footprint: 17.2 X 17.2 mm • Vessel
• Application: Cardiac • HR
• Biopsy is not available
Breast Measurement
• Mass 1 - 10
Measurement and Calculation • Duct dilatation
• Breast Flow
Basic Measurement • HR
• Distance
• Area Circumference Cardiology Measurement
• %Stenosis • Ao/LA
• Volume • LA Vol (Diam)
• Angle • Aorta Diam
• A/B ratio • Pul. Diam
• Volume Flow Area • Vena Cava
• Time • RV
• Slope • Simpson BP
• HR • Simpson SP
• Velocity • Modified Simpson
• Acceleration • Area Length
• S/D Ratio • Teichholz
• PI • LV Mass T-E
• RI • LV Mass A-L
• Trace • LA Vol (A-L)

X-CUBE 70_Product Specificati 11/16


• LA Vol (Simpson) • Outflow tract
• RA Vol (A-L) • RVOT
• RA Vol (Simpson) • Thorax
• TV • Venous
• PISA • FHR
• MV • Tricuspid Valve
• AV • Mitral Valve
• PV • Main Pulmonary A
• Qp/Qs • Aorta
• Pul. Vein • Ductus Art
• TDI • Umbilical A
• HR • Umbilical V
• Ductus Ven
Gynecology Measurement • Pulmonary Valve
• Aortic Valve
• Uterus
• Pulmonary Vein
• Ovary
• Carotid
• Follicle
• MCA
• Fibroid
• SMA
• Pelvic Floor
• Celiac A
• Early Gestation
• Uterine A
• Ovarian
• IVC
• Uterine
• Automated nuchal transparency measurement
• FHR
• Automated fetal biometry measurement
• Ovarian A
– BPD, HC, AC, FL, Humerus
• Uterine A
• Vessel
• Aorta
Emergency Medicine Measurement
• Umbilical A • Aorta
• Placenta • Renal
• Des. Aorta • Bladder
• HR • %Stenosis
• A/B ratio
Obstetrics Measurement • SMA
• IMA
• Early Gestation
• IVC
• Fetal Biometry
• Uterine A
• Fetal Long Bones
• Ovarian A
• Fetal Cranium
• Vessel
• Fetal Others
• HR
• Maternal Others
• Generic
• AFI
MSK Measurement
• CRAR • Volume
• 4 Chamber view • HIP (BA) / Hip (AB)
• Aortic Arch • Vessel
• LVOT • HR

12/16 X-CUBE 70_Product Specificati


Pediatric Measurement • Testicle
• Prostate
• Aorta
• Residual
• Renal
• Vessel
• Renal A
• Bladder
• CHA
• HR
• IVC
• Hepatic V
Vascular Measurement
• Mid HV
• MPV • CCA
• Portal V • ICA
• Splenic A • ECA
• Splenic V • Bulb
• SMA • Vert. A
• SMV • Subclav. A
• IMA • Axill. A
• Iliac A • Basilar A
• Iliac V • Brach. A
• Vessel • DBA
• Hip • Basilic A
• HR • Radial A
• Ulnar A
Renal Measurement • SPA
• Innom. A
• Renal L
• IJA
• Renal
• Subclav. V
• Aorta
• Ceph. V
• Renal A
• Brach. V
• Portal V
• DBV
• Vessel
• Basilic V
• HR
• Radial V
• Ulnar V
Small Parts Measurement
• Innom. V
• Thyroid • CIA
• Isthmus • EIA
• Nodule • IlA
• Lymph Node • CFA
• Parathyroid • DFA
• Thyroid Flow • SFA
• Testicle • Pop. A
• Testicle Flow • PTA
• HR • ATA
• Peron. A
Urology Measurement • DPA
• Renal • Prof. A
• Bladder • CIV

X-CUBE 70_Product Specificati 13/16


• EIV • Audio out port (Right)
• IlV • HDMI port
• CFV • Ethernet port
• DFV • S-Video output port
• SFV • VGA port
• GSV • CVBS output port
• LSV
• Pop. V
• PTV Safety Compliance
• ATV
• Peron. V System Classifications
• DPA
• IEC/EN 60601‐1:6.8.1
• Prof. A
– Type of protection against electrical shock: Class I
• MCA
– Degree of protection against electrical shock (Patient
• ACA connection): Type BF equipment
• PCA P1 – Degree of protection against harmful ingress of
• PCA P2 water: Ordinary equipment and all of applied parts
• Vert. A (IPX7, IPX8) except ECG meet ingress protection level
according to IEC 60529.
• Basilar A
– Degree of safety of application in the presence of
• PComA
a flammable anesthetic material with air or with
• AComA oxygen or nitrous oxide: Equipment not suitable
• Renal A for use in the presence of a flammable anesthetic
• Renal V mixture with air or with oxygen or nitrous oxide.
• Segm. A – Mode of operation: Continuous operation
• Interlob. A
• Arcuate A Standards Compliance
• ABD. Aorta • MDD 93/42/EEC
• SMA • EN ISO 10993-1:2009 (ISO 10993-1:2009)
• IMA • EN ISO 10993-10:2013 (ISO 10993-10:2010)
• Hepatic A • EN ISO 10993-5:2009 (ISO 10993-5:2009)
• Portal V • EN ISO 13485:2016 (ISO 13485:2016)
• Splenic A • EN ISO 14155:2011+AC:2011 (ISO 14155:2011)
• Straight Gft • EN ISO 14971:2012 (ISO 14971:2007)
• Loop Gft • EN ISO 15223-1:2016 (ISO 15223-1:2016)
• Cimino Gft • EN 1041:2008+A1:2013
• Comp Gft • EN 55011:2016+A1:2017 (CISPR 11:2015/AMD1:2016)
• HR • EN 55032:2015 (CISPR 32:2015)
• Automated imtima media thickness measurement • EN 60601-1:2006+A1:2013 (IEC 60601-1:2005/
AMD1:2012)
• EN 60601-1-2:2015 (IEC 60601-1-2:2014)
Inputs and Outputs (I/O) • EN 60601-1-6:2010+A1:2015 (IEC 60601-1-6:2010/
AMD1:2013)
• USB port (6 ports) • EN 60601-2-37:2008+A11:2011+A1:2015 (IEC 60601-2-
– 4 USB 3.0 ports 37:2007/AMD1:2015)
– 2 USB 2.0 ports • EN 61000-3-2:2014 (IEC 61000-3-2:2018)
• Audio out port (Left) • EN 61000-3-3:2013 (IEC 61000-3-3:2013)

14/16 X-CUBE 70_Product Specificati


• EN 61000-4-11:2004 (IEC 61000-4-11:2004)
• EN 61000-4-2:2009 (IEC 61000-4-2:2008)
• EN 61000-4-3:2006+A1:2008+A2:2010 (IEC 61000-4-
3:2006/AMD2:2010)
• EN 61000-4-4:2012 (IEC 61000-4-4:2012)
• EN 61000-4-5:2014 (IEC 61000-4-5:2014)
• EN 61000-4-6:2014 (IEC 61000-4-6:2013)
• EN 61000-4-8:2010 (IEC 61000-4-8:2009)
• EN 62304:2006+A1:2015 (IEC 62304:2006/AMD1:2015)
• EN 62366-1:2015 (IEC 62366-1:2015)
• MEDDEV 2.12/2 Rev.2
• MEDDEV 2.7.1 Rev.4
• NEMA UD2:2004 (R2009)
• Medical Devices Regulations (SOR/98-282)
• 의료기기법, 의료기기법 시행령, 의료기기법 시행규칙

X-CUBE 70_Product Specificati 15/16


Not all features or specifications described in this document
may be available in all transducers and/or modes.

© ALPINION MEDICAL SYSTEMS – All rights reserved.

ALPINION MEDICAL SYSTEMS reserves the right to make changes


in specifications and features shown hereby, or discontinue the
product described at any time without notice or obligation. Contact
you ALPINION representative or the most current information.

You might also like