Project: Installation photovoltaïque 2.775kWc
Variant: New simulation variant
PVsyst V7.2.11
VC0, Simulation date:
24/06/24 17:38
with v7.2.11
Project summary
Geographical Site Situation Project settings
Ariana Latitude 36.86 °N Albedo 0.20
Tunisia Longitude 10.19 °E
Altitude 16 m
Time zone UTC+1
Meteo data
Sukrah
Meteonorm 8.0 (1991-2000), Sat=24% - Synthetic
System summary
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 5 units Nb. of units 1 unit
Pnom total 2775 Wp Pnom total 3000 W
Pnom ratio 0.925
Results summary
Produced Energy 4461 kWh/year Specific production 1608 kWh/kWp/year Perf. Ratio PR 84.38 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6
PVsyst V7.2.11
VC0, Simulation date:
24/06/24 17:38
with v7.2.11
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PV Array Characteristics
PV module Inverter
Manufacturer CSI Solar Manufacturer Ginlong Technologies
Model CS6W-555MS Model Solis S6 GR1P3K-M
(Custom parameters definition) (Custom parameters definition)
Unit Nom. Power 555 Wp Unit Nom. Power 3.00 kWac
Number of PV modules 5 units Number of inverters 1 unit
Nominal (STC) 2775 Wp Total power 3.0 kWac
Modules 1 String x 5 In series Operating voltage 90-520 V
At operating cond. (50°C) Pnom ratio (DC:AC) 0.92
Pmpp 2540 Wp
U mpp 189 V
I mpp 13 A
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 233 mΩ Loss Fraction -0.5 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.11
VC0, Simulation date:
24/06/24 17:38
with v7.2.11
Main results
System Production
Produced Energy 4461 kWh/year Specific production 1608 kWh/kWp/year
Performance Ratio PR 84.38 %
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst V7.2.11
VC0, Simulation date:
24/06/24 17:38
with v7.2.11
Loss diagram
1692 kWh/m² Global horizontal irradiation
+12.6% Global incident in coll. plane
PVsyst V7.2.11
VC0, Simulation date:
24/06/24 17:38
with v7.2.11
Special graphs
Daily Input/Output diagram