Quick Installation Guide
Quick Installation Guide
A General information
Control signals
STO
RJ45 Connection for Bluetooth
RJ45 CAN CAN CAN CAN CAN
GND L SHLD H V+ RA RC
Rating label
Current ratings and switching frequency
TDU00xE000 TDU 4 kHz 5 kHz 6 kHz 7 kHz 8 kHz 9 kHz 10 kHz 11 kHz 12 kHz 13 kHz 14 kHz 15 kHz
INPUT: 3PH, 380~480VAC, 50/60Hz
OUTPUT1: x.x A , x.x kVA 004 3.4 A 3.1 A 2.8 A 2.5 A 2.3 A 2.1 A 1.9 A 1.7 A 1.6 A 1.5 A 1.4 A 1.3 A
OUTPUT2: x.x A, x.x kVA
Page 1/2 | DOC665120/2 | 26 May 2021
FREQUENCY RANGE: 0~320Hz 009 8.2 A 8.0 A 7.9 A 7.6 A 7.1 A 6.6 A 6.2 A 5.7 A 5.3 A 5.0 A 4.7 A 4.4 A
VERSION: x.x
EMC LEVEL MODIFIED 017 16.5 A 16.0 A 15.5 A 14.7 A 13.7 A 12.9 A 12.0 A 11.2 A 10.6 A 9.9 A 9.2 A 8.7 A
OPTION BOARD
028 28.0 A 27.2 A 26.3 A 24.9 A 23.2 A 21.8 A 20.4 A 19.0 A 17.9 A 16.8 A 15.7 A 14.8 A
045 45.0 A 45.0 A 45.0 A 45.0 A 43.2 A 39.6 A 36.0 A 32.9 A 30.2 A 27.5 A 25.2 A 23.0 A
This document and the information contained herein, is the exclusive property of SWF Krantechnik GmbH and represents a non-public, confidential and
proprietary trade secret that may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the
express written consent of SWF Krantechnik GmbH. Copyright 2021 © SWF Krantechnik GmbH. All rights reserved.
B Installation
High voltages inside the device.
Wait at least 5 min after the mains input voltage has been switched off before service actions.
When signal LEDs are on there is dangerous voltage on the DC bus.
When signal LEDs turns off, the DC bus voltage is about 100 V.
Note that there is a dangerous voltage in the braking resistor when DC bus is charged.
°C °F
RH
Preparations
1. Check that the delivery corresponds to the order.
2. Read the safety instructions. Dashboard
3. Check the clearances around device carefully. Disconnected
Parameters
00-00 User Role Key 03-06 Motor Rs
00-01 Drive Selection 03-07 Motor Rr !
Monitor
Monitoring values Events Common fault codes
00-02 Accel Time 03-08 Motor Lm
00-03 Decel Time 03-09 Motor Lx Output frequency Output frequency to the
00-04 Min Frequency 03-10 System Inertia motor F001... Over current
Motor current Output current to the induction F003 Over current
00-05 Max Frequency 03-11 ASR1/2 Switch F F006 Over current
01-00 Motor Nom Volt 03-12 ASR Zero-Speed motor
F007... Overvoltage
01-01 Motor Nom Freq 03-13 ASR1 Low-Speed Motor voltage Output voltage to the motor F010 Overvoltage
01-02 Motor Nom Curr 03-14 ASR2 High-Speed IGBT Internal temperature of IGBT F011... Undervoltage
Page 2/2 | DOC665120/2 | 26 May 2021
01-03 No-Load Current 04-00 DI1 Function… temperature module F014 Undervoltage
01-04 Motor Cos Phi 04-05 DI6 Function DC voltage Inverter DC-link voltage F140 Ground fault
01-05 Motor Nom Power 05-00 Ramp Stretching
F141 Ground fault
Freq reference Frequency reference
01-06 Motor Nom Speed 05-01 Flux Brake F200 CANopen communication
Freq command Frequency command from a F201 Motor overtemperature
01-08 Start Current 05-02 Slowdown Mode radio or a pendant controller
02-00 Brake Open Delay 05-03 Brake Chopper F202 Both directions fault
STO input Safe torque off input status F203 Ramp supervision
02-01 Start DC Time 06-00 Node ID
02-02 Start Frequency 06-01 CAN Speed RO status Status of relay output F204 Parameter fault
02-03 Load Floating Time 06-02 Control Place DI status Status of digital input F205 Parameter fault
03-00 ESR mode 06-03 Process Data 1… CANopen SW Status word of CANopen
03-01 ESR Max Freq 06-09 Process Data 7 CANopen CW Control word of CANopen
03-02 Ramp Scale Freq 07-00 Switching Freq Active Warning Code of active warning
03-03 U/f Zero Freq Volt 08-00 F#1 Fault Record…
Active Fault Code of active fault
03-04 U/f Mid Voltage 08-09 F#10 Fault Record
03-05 U/f Mid Freq Drive Label Drive label code of the
connected frequency converter