1
1. Never attempt to open this scale, no user
serviceable parts inside.
2. Remove all loads from hook when not in use.
3. Do not remove the wire rope stopper. For
safety reasons, always apply it.
4. Before weighing, check and make sure that
all hanging /load- receiving elements/
devices are in good condition. And please
replace the necessary component regularly.
5. Crane scale is only suitable for hanging
from a mechanical hook, e.g. a crane hook.
Check whether the used crane hook or the
lifting device is suitable for the suspended
load.
6. Make sure that there are no persons or
objects under the load; secure Working Area
to prevent any possible injury or damage.
7. The scale is not suitable for weighing a
person.
8. Load the scale only in vertical traction
direction.
9. Always avoid vibration and horizontal
2
force.
10.Prevent jolts, torsion and oscillation (e.g.
by sloping appending) of all kinds. Be sure
to prevent overloading the scales (Stated
Maximum Load  Object Weight + Tare Weight).
Overload could damage the scale (risk of
breakage). Do not use the crane scale to
transport loads (e.g. traveling crane).
11.Never operate the scale in hazardous
locations. The series design is not
explosion-proof.
12.Any structural alterations should not be
made to the scale. This will lead to
incorrect weighing result, to violation of
safety regulations and to destruction of
the scale.
13.Avoid sudden and jerky acceleration or
deceleration of the load (risk of breakage).
Please always follow the instruction.

3
INSTALLATION INSTRUCTIONS

2.1 UNPACK this scale very carefully. Check


and make sure that the following items are
included:
a. This operation manual
b. CSB series scale x 1 (one Power Pack
installed)
c. AC adaptor x 1
d. Wireless remote control x 1 (optional)
e. Additional Power pack x 1 (optional)
Contact your dealer if any item is missing.

2.2 SECURING THE SCALE

2.2.1 This unit must be hanged via a strong


media, e.g. a wire rope or a metal hook, to
a firm support that can withstands at least
5 times of scale capacity.

2.2.2 Make sure that the crane scale is hanged


vertically.

2.3 POWERING THE SCALE


a. This scale is powered by the built-in
rechargeable Power Pack and/or by an AC
4
adapter. An additional Power Pack is
available as option.

b. Check and make sure that the voltage of the


AC adaptor supplied matches with the voltage
of the main output.

c. Insert the output plug of AC adaptor firmly


into the DC input jack of scale. The DC input
jack is located underneath the back of the
scale.

d. Before the first time use, charge the


rechargeable Power Pack for at least 8 hours
consecutively or until the charging
indicator turns green.

e. For safety reasons, do not share the same


mains outlet with other apparatus.

2.4 OPTIMAL INSTALLATION REQUIREMENTS

For optimal results, it is recommended that


this product should be installed in a location
free from corrosive gas, dust, and electronic
interference.
5
SPECIFICATIONS

Test
Net
Model No. Capacity Division Ultimate
Weight
Overload
CSB-3T 300% of
3000kg/6600lb 1kg/2lb 13.6kg
R.C.
CSB-5T 300% of
5000kg/11000lb 2kg/5lb 19.5kg
R.C.
CSB-7.5T 300% of
7500kg/16000lb 5kg/10lb 29.6kg
R.C.
CSB-10T 300% of
10000kg/20000lb 5kg/10lb 29.6kg
R.C.
CSB-15T 300% of
15000kg/30000lb 5kg/10lb 73.1kg
R.C.
CSB-20T 300% of
20000kg/40000lb 10kg/20lb 73.1kg
R.C.
By Built-in Rechargeable Power Pack and/or,
Power
Source DC12~15V,500mA or 1A.
Fixed type for CSB models and Wire Rope
Hook Type Stopper Included
Tare Range Full Range
Zero Range Maximum = 2% of Rated Capacity
Wireless or Cable Remote Control,
Optional Power Pack (24 Hours Non-stop
Options Operation)

*To comply with the law of certain countries, the pound unit may be

disabled. AC Adaptor might differ from country to country.

Specifications and functions subject to change without prior notice.

6
DIMENSIONS FOR CSB (mm)

DIMENSIONS (mm):

Model
A B C D E F G H HOOK
Cap.
CSB-3T 211 118 181 183 58 36 50 264 6.5T
CSB-5T 211 164 181 188 72 43 60 274 9.5T
CSB-7.5T 211 254 181 255 90 48 70 298 13.5T
CSB-10T 211 254 181 255 90 48 70 298 13.5T
CSB-15T 211 361 181 462 150 88 95 304 35T
CSB-20T 211 361 181 462 150 88 95 304 35T
A H
E
B
C

F
D

7
KEYBOARD LAYOUT

CSB

8
KEYS AND INDICATORS

1. POWER ON/OFF KEY


Press this key to turn scale on/off.

2. HOLD KEY
Press this key to hold/release the current
weight being displayed/held.

3. MODE KEY
Press this key to switch between measurement
units, or to convert a weight reading into the
other unit of measurement. (In Metric System
Countries, this key will be without any
function.)

4. TARE KEY
Press this key to tare off the weight of a
container or decrease value during function
setting.

5. ZERO KEY
Press this key to set weight to zero, or increase
value during function setting.
9
6. ZERO INDICATOR
When the weight detected is at true zero, ZERO
indication will appear (ON).

7. TARE INDICATOR
When the tare function is being employed, a
TARE indication will appear (ON).

8. METRIC INDICATOR
When this indicator is on, the metric weight
unit is being employed.

9. POUND INDICATOR
When this indicator is on, the pound weight
unit is being employed. (This indicator may
not be available in certain countries).

KEYS ON REMOTE CONTROL (OPTION)

10. ZERO KEY


Press this key to set weight to zero (max. zero
range = 2% of rated capacity).

11. TARE KEY


10
Press this key to tare off the weight of a
container.

12. MODE KEY


Press this key to shift between weight units.

13. HOLD KEY


Press this key to hold/release the current
weight being displayed/ held.

11
INTERNAL FUNCTIONS

6.1 INTERNAL FUNCTION TABLE


Function Symbol Description NOTE

1 Fun-1 Scale configuration **


setting and dealer
Calibration.
2 Fun-2 Display segment
check.
3 Fun-3 Offset value and span **
value reading.
4 Fun-4 Auto power off
setting

NOTE **:
For dealer and authorized personnel only.
Inappropriate setting(s) will cause system
failure. Contact your dealer for more
information or service.

6.2 HOW TO ENTER THE REQUIRED FUNCTION MODE


a. Turn scale off.
b. Press and hold TARE, then turn scale on.
Scale displays Fun-1
c. Press TARE until the required function
number appears.
d. Press MODE

12
e. Press MODE until the required setting
appears.
f. Press TARE to confirm.
g. Repeat step c to f for other function setting,
or
h. Press ZERO to save settings and return to
normal operation.

6.3 INTERNAL FUNCTIONS DESCRIPTION

Fun-1 Contact your dealer for more


information.
Fun-2 To check all display segments work
properly.
Fun-3 Contact your dealer for more
information.
Fun-4 To set Auto Power Off Function.
Two modes are available: (Default =
4_OFF)
0._OFF = Auto Power Off Function is
disabled.
4._OFF = Scale will automatically
turned off after 4 minutes
unused.

13
OPERATING INSTRUCTIONS

8.1 PLACING THE SCALE


Hang this scale with a strong enough media where
is free from RF interference, vibration, fire,
direct sunlight and excessive moisture.

For safety reasons and best weighing result,


always hang this scale and lift a load
vertically.

8.2 POWER ON/OFF THE SCALE


Press ON to turn scale on.
Press OFF to turn scale off.

8.3 ZERO FUNCTION


If ZERO INDICATOR does not appear when scale
is unloaded, press ZERO to reset weight
displayed to zero. Refer to general
specification table for maximum zero range.

8.4 TARE FUNCTION


8.4.1 To Tare Off the Weight of a Container
Apply a container to hook, then press TARE
to tare off the weight of it. After the TARE
is pressed, the TARE INDICATOR appears.
14
8.4.2 To Clear the Weight of a Container
from memory
Remove the container from hook then press
TARE. The tare indicator will go off
indicating no container weight is resided
in memory.

8.5 PLACING A LOAD


Always apply a load to hook gently. Sudden shock,
excessive force or overloading the scale may
cause damage to the weight sensor inside.
It is a good practice to remove all loads from
hook when not in use.
This would prolong the lifetime of weight
sensor.

8.6 WEIGHING FUNCTION


a. Before weighing, make sure that the Zero
Status Sign is on.
b. Press MODE until the required weight unit
appears.
c. Apply subject matter to hook and the weight
of it is displayed.
d. For best weighing result, refer to general
specification table for recommended
minimum weight to be applied.
15
8.7 HOLDING THE WEIGHT BEING DISPLAYED
a. Press HOLD to hold the weight being display.
For accuracy considerations, only press
HOLD when weight is stable.
b. After HOLD is pressed, the flashing weight
value appears.
c. To release weight value being held, press
HOLD again.

8.8 AUTO-HOLD FUNCTION


This function provides a smart way to reduce
the waiting time for stable weighting.
While the weight is placed on the hook, an
average weight value will be calculated and
held on the display for few seconds depending
on the Auto-Hold Time Period setting.
Auto-Hold Time Period setting:
1. Press HOLD key for about 2 seconds, the
display will read “Hod._0”
2. Press the HOLD key to increase the time
period for 3, 5, 8, 10, 12, 15, 17, 20
(sec.) in sequence.
3. Choose the time period, then wait for
about 5 sec., it will be switched back
to normal operation automatically.
16
8.9 SHIFT BETWEEN DIFFERENT WEIGHT UNITS
Press MODE to shift different weight units.
NOTE: The pound unit may not be available in
certain countries.

8.10 SWITCHING BACKLIGHT ON/OFF


Method 1: During operating process, the
backlight can be switched ON/OFF by
pressing the MODE key to shift to the desired
status.
Method 2: When unloaded (weight=0), press
and hold the ON/ZERO key for about 2
seconds to set backlight ON/OFF.

8.11 RECHARGING THE SCALE


8.11.1 When low battery signal appears,
insert a charged Power Pack or apply the
AC adaptor to recharge the inserted Power
Pack. Failure in doing so may cause
irrecoverable damage to the rechargeable
Power Pack.

8.11.2 Low battery signal is represented


by either case of the follows depends on
operating status.
8.11.2.1 Low battery is detected when power
17
on
Scale shows LOBAT after self-test down
count but displaying zero weight.

8.11.2.2 Low battery is detected during


operation
Weight display flashes once every 5
seconds.

8.12 REMOTE CONTROL


a. Pressing the corresponding key on the remote
control can attain same control results.

NOTE: All internal function settings can only


be operated through scale panel keys.
b. Operation distance from CSB scale to
wireless remote control is 10 meters
unobstructed.
c. When remote control distance decreases,
change the battery located inside the
wireless remote control.
d. Unique radio frequency is assigned to
specified unit. Never change DIP switch
setting of the wireless remote control.

18
TROUBLESHOOTING

SCALE CANNOT BE TURNED ON

 CHECK: Is the rechargeable Power Pack


properly charged and plugged?
ACTION: Reexamine the Power Pack and make
sure that the Power Pack is
charged (8 hour charging time is
recommended during first time
use).

ZERO WEIGHT CANNOT BE ATTAINED WHEN TURNED ON

 CHECK: Is the scale hanged vertically?


ACTION: Check and try again.

 CHECK: Is any load applied to the hook?


ACTION: Remove all loads from hook. Turn
scale off and turn on again.

 CHECK: Is the scale affected by airflow,


vibration or RF interference?
ACTION: Place scale away from all
disturbances and try again.

19
RATED CAPACITY CANNOT BE ATTAINED

 CHECK: Is TARE function being utilized?


ACTION: Remove all loads from hook, press
TARE and try again.

00000
SCALE DISPLAYS

 CHECK: Is the scale overloaded?


ACTION: Remove all loads from hook
immediately and check again.

SCALE DOES NOT WEIGH CORRECTLY

 CHECK: Is the correct weight unit being


utilized?
ACTION: Select the correct weight unit.

 CHECK: Is min. weight applied to scale?


ACTION: Refer to General Specifications
for recommended min. load
applied and try again.

 CHECK: Is the load lifted vertically?


ACTION: Remove all loads and retry.
20
 CHECK: Is the scale affected by airflow,
vibration or RF interference?
ACTION: Place scale away from all
disturbances.

 CHECK: Does the scale have the correct


calibration?
ACTION: Contact your dealer.

SCALE TURNED OFF AUTOMATICALLY

 CHECK: Is the AUTO POWER OFF function


being utilized?
ACTION: Disable the AUTO POWER OFF
function.

 CHECK: Is the LOW BATTERY sign on?


ACTION: Insert a charged Power Pack or
use AC adaptor.

WIRELESS REMOTE CONTROL DOES NOT FUNCTION

 CHECK: Is the distance between the scale


and the wireless remote control
exceeding maximum transmission
range?
21
ACTION: Try again in a shorter distance.

 CHECK: Is the battery of the wireless


remote control low?
ACTION: Change the battery with a new
one.

 CHECK: Does the transmission frequency


matches with the receiving
frequency?
ACTION: Contact your dealer.

 CHECK: (For CSB models only) Is the


antenna correctly attached to
the scale?
ACTION: Attach the antenna to the scale
and try again.

22
WARRANTY

Warranty varies from country to country.


In general, all products carry a one-year
warranty from factory shipment (Battery is
guaranteed for three months only). If other
consumer protection laws are applied, please
refer to your local dealer/representative for
more information.
The warranty only applies to product
failures due to defective materials and/or
workmanship. Wear-out caused by frequent use
is not considered as a result of defective
material (it highly depends on the frequency
and load applied to the scale). The warranty
will be rendered invalid if, upon inspection,
it is found that the product was abused; used
in a way for which it was not designed;
mishandled; placed in a hostile environment;
repaired by unauthorized personnel;
improperly installed or not adjusted in
accordance with instructions given in this
manual.
For service, please contact your local
dealer.
23
DAILY CARE AND MAINTENANCE

a. Do not open scale for any reason. Contact


your dealer for servicing.
b. Avoid exposing scale to direct sunlight or
excess moisture.
c. Do not submerge scale in water or drop scale.
d. Remove all loads from hook before
transportation.
e. Clean the scale with a soft and damp cloth,
if necessary with mild detergent.
f. Do not use any harsh, abrasive material;
violate solvent thinner or alcohol for
cleaning.
g. Verify the accuracy of scale periodically.
Re-calibrate the scale when needed.

NOTE: In some countries, calibration is


restricted to be done by qualified or
authorized agent only. Contract your
dealer for more information.

24
h. If the hanging hook or the hanging ring wears
down due to attrition or appears defective,
such as cracks or a change in shape, stop
the use immediately and send it to an
authorized dealer for repairs or for the
replacement of the part, before resuming
usage.
i. Store scale in a dry and cool place.
j. Charge the rechargeable Power Pack once
every 3 months when not in use in order to
keep the Power Pack functioning properly.