Containerized ESS (LV) SYSTEM PARAMETERS

CS40HN-P4000B4608-E & CS40HN-P4000B9216-E &CS40HN-P4000B13824-E & CS40HN-P4000B18432-E


CS40HN-P4000B4608 CS40HN-P4000B9216 CS40HN-P4000B13824 CS40HN-P4000B18432
System Type
-E -E -E -E

DC Side

Cell Type LFP C15 LFP C15 LFP C15 LFP C15

Highly integrated battery container, PCS


Module Type 1P9S 1P9S 1P9S 1P9S

to provide customers with AC low-voltage


String Type 1P225S(25 Modules) 1P225S(25 Modules) 1P225S(25 Modules) 1P225S(25 Modules)

grid-connected energy storage system.


System Configuration 20x1P225S 40x1P225S 60x1P225S 80x1P225S
DC Usable Energy 4245kWh 8582kWh 12872kWh 17163kWh
(BOL)@FAT
Battery Voltage Range 630~810V 630~810V 630~810V 630~810V

AC Side
Nominal Power 4000kVA 4000kVA 4000kVA 4000kVA
AC Usable
4160kWh 8410kWh 12615kWh 16820kWh

SYSTEM FEATURES
Energy (BOL)@FAT
AC Energy at Full
3952kWh 8410kWh 12615kWh 16820kWh
Power (BOL)@FAT
Highly Integrated & Cost-effective Nominal Voltage/ 400V/360~440V 400V/360~440V 400V/360~440V 400V/360~440V
Integrate core equipment such as PCS, LFP batteries, RMU, transformer, local controller, all-in-one design and total Voltage Range
delivery Cell-level precise temperature control, intelligent charge and discharge management, longer battery cycle life. Nominal Grid Frequency/ 50Hz/47~52Hz 50Hz/47~52Hz 50Hz/47~52Hz 50Hz/47~52Hz
Grid Frequency Range
Power Factor 0.95(lagging)~0.95(leading) 0.95(lagging)~0.95(leading) 0.95(lagging)~0.95(leading) 0.95(lagging)~0.95(leading)

Unified Management & Safe And Reliable THD <3% (@Nominal) <3%(@Nominal) <3% (@Nominal) <3% (@Nominal)
Integrate the local controller, unify the communication interfaces and protocols to realize the comprehensive
management of equipment.AC side online insulation detection, four-level fuse, five-level linkage protection
Isolation Method Transformer-less Transformer-less Transformer-less Transformer-less

design. Intelligent fire suppression system, multi-point monitoring and early warning. General Parameters

CIRCUIT DIAGRAM
Dimensions 12192x2438x2896mm 12192x2438x2896mm 12192x2438x2896mm 12192x2438x2896mm
(Container) (W×D×H)
Dimensions 1510x1350x2300mm 1510x1350x2300mm 1510x1350x2300mm 1510x1350x2300mm
(PCS) (W×D×H)
LFP Battery Unit #1
Battery Container Weight 29000kg 29000kg 29000kg 29000kg
Battery String #1

PCS Weight 1350kg 1350kg 1350kg 1350kg


BMS
IP Rating IP54 IP54 IP54 IP54

PCS#1
L3 Operating Ambient -20°C~+45°C【1】 -20°C~+45°C【1】 -20°C~+45°C【1】 -20°C~+45°C【1】
Battery String #10 L2
Temperature
L1

Relative Humidity 5%~95% 5%~95% 5%~95% 5%~95%


BMS
Max. Working Altitude <3000m <3000m <3000m <3000m

Smart HVAC FSS Cooling Concept (PCS) Forced air cooling Forced air cooling Forced air cooling Forced air cooling

Battery String #1 Cooling Concept


(Battery Container) Smart Air Cooling Smart Air Cooling Smart Air Cooling Smart Air Cooling

BMS Fire Suppression HFC-227ea Fire HFC-227ea Fire HFC-227ea Fire HFC-227ea Fire
System Extinguishing Extinguishing Extinguishing Extinguishing

PCS#5
L3 Communication Interfaces Ethernet Ethernet Ethernet Ethernet
Battery String #10
L2
L1
Communication Protocols Modbus TCP/IP Modbus TCP/IP Modbus TCP/IP Modbus TCP/IP
BMS
Compliance IEC62619,UL1642,UL1973,UL9540A

Smart HVAC FSS Unit Controller EMS Standard Color RAL9003/RAL6012 RAL9003/RAL6012 RAL9003/RAL6012 RAL9003/RAL6012

LFPBattery Unit #2 Note:


【1】Power derating is performed when the ambient temperature is above 45℃.