MC-CarbonFiber® Lamella

(Formerly Known as MC-Dur CFK Lamellen)


Surface-bonded, Carbon-fiber
strips for structural reinforcement
Product Properties

• MC-CarbonFiber® Lamella based on an epoxy resin matrix, reinforced with unidirectional carbon fibers
• High tensile strength at small cross-section and low structural height.
• Easy application, low weight, high efficiency
• Removal of dust by suction cleaning.
• Optimized utilization of mechanical properties due to alternative types/qualities.

Areas of Application

• Subsequent reinforcement of structural components made of reinforced concrete, pre-stressed concrete, masonry and wood.
• Increase and reconstruction of load bearing capacity and/or serviceability
• Reduction of structural deformation and subsequent restriction of crack widths.
• Interior and exterior areas of new and old structures.

Application

Preliminary Inspection Application


Prior to application the actual state of the structure to be The MC-CarbonFiber® Lamella must not be bent at right angles or
reinforced must be determined and the application requirements subjected to sharp lateral pressures. The Strips can be cut to size on
for the process must be verified by the structural engineer in site. The MC-CarbonFiber® Lamella have to be cleaned before
charge with proper structural auditing of the structure. The application using suction cleaning or lint-free white cloth in order to
structural analysis is carried out in accordance with Standard produce absolutely clean surface for subsequent gluing.
Guidelines.
The MC-CarbonFiber® Lamella adhesive MC-CarboSolid® 1280 is
Performance of work mixed according to the manufacture’s advice and applied according
to the general building approval. The MC-CarbonFiber® Lamella do
Application and monitoring are carried out by qualified staff with an
not require any support whilst hardening.
additional certificate for application of MC-CarbonFiber® Lamella
issued by MC-Bauchemie.
If used on surfaces exposed to weathering the MC-CarbonFiber®
Substrate Preparation Lamella must be protected against direct sun by application of
surface protection system. If used on surfaces exposed to
All substrates to be reinforced must be prepared by suitable mechanical impact the strips must be protected respectively.
manner, e.g. granulate blasting. The surface must be sound, dry
(residual moisture ≤ 6%) and free from any dust and grease. Quality assurance
Before application of the MC-CarbonFiber® Lamella the Production of the MC-CarbonFiber® Lamella is subject to an in-
evenness of the concrete surface is to be verified. The surface can house production control and an external surveillance. Application is
be levelled (roughness < 1.0 mm) with the levelling mortar. monitored according to the general building approval.

All the Surface should be repaired by MC Range Concrete


replacement, before application of MC-CarbonFiber® Lamella.
For Patch repair MC range epoxy system or Nafufill Range Repair
Mortar system should be recommended before application of MC-
CarbonFiber® Lamella. All the Pin holes, bug holes should be
Filled and levelled by using Epoxy putty.

MC-Bauchemie (India) Private Limited, B-501, Shelton Sapphire, Sector-15, CBD Belapur, Navi Mumbai 400614, India
Tel: 022- 27563867/ 27570803 / 27572856, e-mail: [email protected] www.mc-bauchemie.com
Technical Data For MC-CarbonFiber® Lamella
50/1,4 100/1,4 100/2,4
Characteristic Unit Value Value Value Comments
Nominal Width mm 50 100 100
Nominal Thickness mm 1,4 1,4 2,4
Design Area mm2 70 140 240
Modulus of elasticity gpa 152 152 152
Ultimate tensile strength mpa 2120 2120 2120
Elongation at break % 1,7 1,7 1,7

Product Characteristics for MC-CarbonFiber® Lamella


Matrix Epoxy resin
Colour Black
Durability Unlimited, provided proper storage
Strip Preparation Suction Cleaning or Cleaning with a Lint-free white cloth
UV Protection MC-Surface protection system
System products MC-CarboSolid® 1280
MC-DUR Putty

Safety Advice
Please Take notice of the safety information and advice given on the packaging labels, safety information sheets and General Application
Advice.

Note: - The information on this Data Sheet is based on our experiences and correct to the best of our knowledge. It is However, not binding. It has to be adjusted to the individual
structure, application purpose and especially to local conditions. Our Data refers to the accepted engineering rules, which have to be observed during application. This provided we are
liable for the correctness of this data within the scope of our terms and conditions of sale-delivery-and-service. Recommendations of our employees which differ from the data
contained in our information sheets are binding if given in written from. The accepted engineering rules must be observed at all times.

Edition: - MC/IND/190512, Some Technical Changes have been made to this print medium. Older editions are invalid and may not be used anymore. If a technically revised new
edition is issued, this edition becomes invalid.

MC-Bauchemie (India) Private Limited, B-501, Shelton Sapphire, Sector-15, CBD Belapur, Navi Mumbai 400614, India
Tel: 022- 27563867/ 27570803 / 27572856, e-mail: [email protected] www.mc-bauchemie.com