Ancamide 2426U
Ancamide 2426U
STORAGE LIFE
At least 24 months from the date of manufacture
in the original sealed container at ambient
temperature. Store away from excessive heat
and humidity in tightly closed containers.
Air Products and Chemicals, Inc., 7201 Hamilton Boulevard, Allentown, PA 18195-1501
Tel: (800) 345-3148, (610) 481-6799, Fax: (610) 481-4381, http://www.airproducts.com/epoxyadditives
The information contained herein is offered without charge for use by technically qualified personnel at their discretion and risk. All statements, technical information and recommendations contained
herein are based on tests and data which we believe to be reliable, but the accuracy or completeness thereof is not guaranteed and no warranty of any kind is made with respect thereto.
Blush Resistance
Ancamide 2426 curing agent offers significantly improved blush resistance compared with standard amidoamine
curing agents. At ambient temperature, Ancamide 2426 curing agent-based films have only a slight haze with no
induction time, and no haze with 15 minutes of induction time.
Hardness Development
Pendulum hardness with no induction time was measured for 3-mil DFT clear films based on Ancamide 2426
curing agent. Excellent hardness was achieved within the typical 7-day cure schedule, and the rate of hardness
build accelerated within the first 3 days.
Corrosion Resistance
4-mil thick clearcoat films on grit blasted steel panels and 5-mil clear films on cold rolled steel were tested for
1000 hours for humidity resistance per ASTM D-2247. The schedule utilized was 10 hours wet at 104 °F followed
by 2 hours dry at 113 °F. There was no blistering or visible corrosion at the end of the test period on either
substrate.
Chemical Resistance
Ancamide 2426 curing agent offers good chemical resistance to many aqueous solutions in immersion conditions.
Results for liquid epoxy resin (EEW = 190) cured for 7 days at ambient temperature are shown below. Chemical
resistance data is expressed as percent weight change. Testing was completed in accordance with ASTM D543-
83.