Wind Load Calculations
Wind Load Calculations
COLLATERAL LOAD
Collateral Load on Rafter = 15.00 Kg/m² Other Collateral Load = 0.00 Kg/m²
= 0.85 KN/m = 0.00 KN/m
PRESURE COEFFICIENTS:~
Encloser condition of the building = Enclosed
Internal pressure coeff.(Cpi) = 0.20
h/w = 0.14
= h/w<=1/2
l/w = 1.44
= 1<l/w<=3/2
External pressure coeff.(Cpe) : Table 4 Table 5
Wind Angle Coeff. For Wall Coeff. For Roof
(ө)
Left Right Left Right
0 degree 0.70 -0.20 -1.2000 -0.40
90 degree -0.60 -0.60 -0.80 -0.60
Wind Across the Ridge (With -Ve Cpi) Wind Across the Ridge (With +Ve Cpi)
KN/m
-1.00 -5.44 KN/m -0.20 -1.09KN/m -1.40 -7.614 KN/m -0.60 -3.26
KN/m KN/m
-4.35 -4.35
-0.80 -0.80
KN/m KN/m
-2.18 -2.18
-0.40 -0.40
Note:
1) Values within the circles are the UDL
2) -Ve value means, load applied
away from structure.
DOUBLE SLOPED ROOF
Cpi ±0.2
Wind Load
CANOPY Cpe -0.5
0.2
Cpi = -0.2 Cpi = 0.2 Cpi = -0.2 Cpi = 0.2
W1 (→) W2 (←) W3 (→) W4 (←) W5 (↓) W6 (↑) W7 (↓) W8 (↑)
LOAD (kN) LOAD (kN) LOAD (kN) LOAD (kN) LOAD (kN) LOAD (kN) LOAD (kN) LOAD (kN)
A 8.655 -0.481 4.808 -4.328 -2.885 -2.885 -6.732 -6.732
B -0.481 8.655 -4.328 4.808 -2.885 -2.885 -6.732 -6.732
C -4.811 -4.811 -9.622 -9.622 10.825 1.203 6.014 -3.608
D -4.811 -4.811 -9.622 -9.622 1.203 10.825 -3.608 6.014
LEFT ROOF -9.617 -1.923 -13.464 -5.770 -2.885 -2.885 -6.732 -6.732
RIGHT ROOF -1.923 -9.617 -5.770 -13.464 -2.885 -2.885 -6.732 -6.732
CANOPY -2.885 -2.885 -6.732 -6.732 -2.885 -2.885 -6.732 -6.732