Acterna OMS-150, OMS-200

Optical Measuring System


Features
. Modular, expandable system
guarantees cost-effective
performance
. Broad range of modules for
different applications
. Main application areas are
laboratories and production
test departments
. Inexpensive, time-saving
WDM mode for simultaneous
measurement at 1310 and
1550 nm
. Large high-contrast color
TFT liquid crystal display;
color combinations are user-
selectable
. Dual 1310/1550 nm laser
diode source with wide range
of settings from 0 to ±10 dBm
. Variable 60 dB attenuator with
monitor output for connection
to a reference level meter
Modular, expandable system OMS-150 . Long-term measurements
The OMS-150 is best suited to manual supported by built-in
The OMS Optical Measuring System is an measurements or tests of a random sampling application software
economical, future-oriented solution for of DUTs (Devices Under Test). This main- . Straightforward programming
most fiber optics measurements in the tele- frame is equipped with a high-contrast with test module drivers
com and datacom sectors. The modular for all common software
5.5@ color TFT liquid crystal display which development tools
design of the system means that it can be allows straightforward manual operation
easily adapted for different applications. . Windows application software
with softkeys and direct display of the for setting up the OMS-200
A wide variety of modules is available, in- results. The OMS-150 accepts up to three . Remote control via IEEE 488.2
cluding sources, power meters, attenuators measurement modules and is the most or RS232 interface
and reflection meters. The application soft- economical solution for laboratory appli-
ware built into the OMS firmware allows cations.
execution of automatic test sequences with
no additional programming work. OMS is OMS-200
based on a strict division between measure- In production of optical components and
ment and evaluation/display functions. The systems, manufacturers need to automati-
modules handle the measurement functions, cally test as many DUTs as possible in the
while the mainframe evaluates the results least possible time. The OMS-200 Optical
and communicates with the outside world. Measuring System with its 19@ rack-
With this concept the number of available mountable housing is ideal for this appli-
modules can grow to handle new measure- cation: The number of possible modules is
ments. increased to eight by eliminating the manual
controls and display. This means that more
Main application areas of complex tests (or multiple concurrent tests)
OMS-150 and OMS-200 can be performed at a lower cost. The
OMS-200 is also the right system for cali-
Depending on the application and the
bration laboratories and test shops which
number of modules required, either the
perform type acceptance testing using fixed
OMS-150 or the OMS-200 should be
test setups for many diverse measurements.
selected as the mainframe.
The system is remotely controlled from an
external computer via the IEEE 488/IEC
625 bus or the RS232/V.24 (V.28) serial
interface.
Drivers for all common software Powerful measurement modules
development tools Power meters for various level ranges are available with a
LabWindows for DOS and LabWindows/CVI for Windows range of additional functions. Laser sources with stabilized
are widely available software tools which allow straight- wavelengths and output level are required for attenuation
forward programming of instrument control and result measurements and calibration tasks. Each attenuator module
acquisition, display and documentation functions. The drivers is individually calibrated and can be used for measuring the
needed to use these software development tools are available sensitivity and dynamic range of system receivers and deter-
for all modules. mining system linearity. The OBR-100 Back-Reflection Meter
provides facilities for wide dynamic range, high-linearity back-
Drivers for other software tools such as LabVIEW or HP reflection measurements on connectors and components.
VEE are available, too.
Stable measurements and data logging
Simple OMS-200 setup
The built-in applications software for the OMS Optical
Since the OMS-200 has no front-panel controls, it must be Measuring System provides for long-term stability measure-
operated using an external PC or controller. As a general ments and single measurements. Power stability measure-
rule, the necessary test software is not available off the shelf. ments are mainly required on transmitter modules. The sys-
To make it easier for users to get the OMS-200 up and run- tem makes continuous measurements during the intervals
ning, application software is included so that OMS-200 can into which the presettable overall measurement time is
be manually operated from a PC. The software runs under divided. The minimum and maximum results in each inter-
Windows 95 and 98. The operation of the system and display val are evaluated. For automatic single measurements, only
of results are the same as the OMS-150. one measurement is made per interval. The results are
shown graphically on the display. They can be output to a
Assistance in setting up test programs printer or plotter via the IEEE 488 or RS232 interfaces. Out-
The monitor function of the OMS-200 is a useful tool when put as a table is also possible if a printer is used. It is also
preparing the test setup and software. A terminal, or a PC possible to log data by triggering measurements manually;
with terminal software, is connected to the RS232 interface the results obtained are stored and displayed graphically.
on the front panel to query status registers during program
execution as well as other parameters for the individual Traceable calibration
modules. This makes it easy to detect errors which occur The modules for the OMS Optical Measuring System are
during program execution. Measurements cannot be initiated calibrated against standards traceable to those of the Federal
via this interface. German Bureau of Standards (Physikalisch-Technische
Bundesanstalt, PTB), this traceability being equivalent and
exchangeable with the standards of other national metrology
institutes such as NIST (USA) or the NPL (UK). Acterna is
an accredited calibration center member of the German
Calibration Service (DKD).
Modules (overview)
Power Meter Modules OLP-xxx
Operating modes
Version Wavelength range Input power range
CW 1) AC 2) WDM 3)
OLP-130 800 to 1600 nm ± 90 to +27 dBm & & &
OLP-150 800 to 1700 nm ± 90 to +13 dBm & & &

Optical Source Module


Operating modes
Version Wavelength range Output power/setting range Stability Modulation frequencies
CW 1) AC 2) WDM3) DUAL4)
OLS-150 1310, 1550 nm (LD) 0 dBm (CW)/+0.5 dB, ±10 dB +0.005 dB (typ.) 270 Hz/330 Hz/1 kHz/2 kHz & & & &

Attenuator Module Back-reflection Meter Module


Version Wavelength range Attenuation range Attenuation setting Version Wavelength range Display range Applications
OLA-150 1260 to 1600 nm 2 to 65 (60) dB Continuous setting OBR-100 1250 to 1600 nm 0 to ± 70 dB Measurements on fiber
or with selectable optic connectors and
step width. components; WDM mode.

1) Power Meters: Average measurement; Sources: Continuous wave 3) Wavelength division multiplex operation with modulated light (270 Hz, 330 Hz).
2) Modulated light operation for frequency-selective signal evaluation 4) Wavelength division multiplex operation with continuous wave light (CW).

Specifications for OMS-150 and OMS-200 Mainframes


OMS-150 OMS-200
Module housing for up to three fiber optical test modules. Module housing for up to 8 fiber optical test modules.
Modules can be fitted in any combination or arrangement. Modules can be fitted in any combination or arrangement.
Automatic module detection. Automatic module detection.

Display . . . . . . . . . . . . . . . . . . . . . . .TFT color LCD graphic display, Monitor function


3206256 pixels, 5.5@; Status and parameter query; no control over test functions
5 color combinations selectable Connection of RS-232 terminals or PCs with terminal software
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . function keys, Interface (front panel) . . . . . . . . . . . . . . . . . . to RS232 (V.24, V.28)
number keypad and rotary control 9-pin subminiature D connector
Ambient temperature (including plug-in-modules) Ambient temperature
Operating range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to +50 C Operating range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +5 to +40 C
Storage and transport. . . . . . . . . . . . . . . . . . . . . . . . . ± 40 to +70 C Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 40 to +70 C
Dimensions (w6h6d) in mm . . . . . . . . . . . . . . . 34961596357 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 5 to +45 C
Weight (with no modules installed) . . . . . . . . . . . . . approx. 6.1 kg Dimensions (w6h6d) in mm. . . . . . . . . . . . . . . . 47761996434
Weight (with no modules installed) . . . . . . . . . . . . . approx. 8.8 kg

Common Specifications for OMS-150 and OMS-200


Remote control Electromagnetic interference
Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . 5IEC 6254/IEEE 488.2 (including plug-in modules) . . . . . . Conforms to CE requirements
RS-232 (V.24/V.28) EMI/RFI generation . . . . . . . . . . . . . . . . . . . . . . to EN 50081-1:1992
Command language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SCPI (CISPR 22 Class B)
EMI/RFI susceptibility . . . . . . . . . . . . to EN 55082-1:1992 61010-1
Power supply
Instrument safety class . . . . . . . . . . . . . . . . . . . . . Class I, IEC/EN
AC line voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 100 to 240 V +10%
AC line frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz +5%
Specifications for OMS-150 and OMS-200 Modules
Optical Power Meter Modules
OLP-130 OLP-150
Wavelength range 800 to 1600 nm 750 to 1700 nm
Photodiode InGaAs, fiber coupled InGaAs, 3mm; directly irradiated
Power measurement
Display range ± 90 to +27 dBm ± 90 to +13 dBm
Display units dBm or Watt, dB
Resolution
Manual operation 0.001 dB/0.001 pW
Remote control 0.0001 dB/0.001 pW
Optical interface
Measuring adapter for FC, SC, DIN, ST, E-2000, etc., for FC, SC, DIN, ST, E-2000, etc.,
Adapter BN 2060/00.xx Adapter BN 2014/00.xx
Connectable fiber type 9/125 to 50/125 mm, NA 5- 0.22
4)
9/125 (SM) to 100/140 mm (MM), NA 5- 0.3
Return loss (if angled
PC connectors are used) 450 dB (typical) 450 dB (typical)
Max. input power +27 dBm +13 dBm
Signal evaluation
Unmodulated light, CW Measurement of unmodulated and modulated light (average value display)
Modulated light, FMOD: Selective measurement of modulated light (square wave signals with duty cycle 1:1 and
270 Hz, 330 Hz, 1 kHz, 2 kHz modulation depth 100%), display of peak value
Modulated light, WDM Selective power measurement at two wavelengths simultaneously, characterized by modulation
frequencies of 270 and 330 Hz
Measurement uncertainty 1) 0.14 dB (+3,3 %) 0.09 dB ( +2 %)
(incl. aging)
Total measurement uncertainty
CW measurement 2)
1200 to 1600 nm +0.20 dB +20 pW5) (± 75 to +21 dBm) +0.16 dB +1.6 pW (± 80 to +8 dBm)
850 to 1200 nm +0.22 dB +100 pW5) (± 70 to +21 dBm) +0.26 dB +12 pW (± 70 to +8 dBm)
750 to 850 nm Ð +0.26 dB +24 pW (±70 to +8 dBm)

Measurement of modulated light 3)


1200 to 1600 nm +0.17 dB (± 70 to +8 dBm)
850 to 1200 nm +0.27 dB (± 65 to +8 dBm)
750 to 850 nm Ð +0.27 dB (± 62 to +8 dBm)

Linearity
CW measurement 2)
1200 to 1600 nm +0.030 dB +20 pW (± 60 to +21 dBm) 6) +0.03 dB +1.6 pW (± 80 to +8 dBm)
850 to 1200 nm +0.030 dB +100 pW (± 60 to +21 dBm) 6) +0.03 dB +12 pW (± 70 to +8 dBm)
750 to 850 nm Ð +0.03 dB +24 pW (± 70 to +8 dBm)

Measurement of modulated light 3)


1200 to 1600 nm +0.035 dB (± 55 to +21 dBm) 7) +0.07 dB (± 75 to +8 dBm)
850 to 1200 nm +0.035 (± 50 to +21 dBm) 7) +0.07 dB (± 65 to +8 dBm)
750 to 850 nm Ð +0.07 dB (± 62 to +8 dBm)

Warm-up time to meet specifications 30 min


Traceability to PTB
Recommended calibration interval 1 year
General specifications
Dimensions (w6h6d) in mm 3861026288 3861026288
Weight approx. 850 g approx 650 g
1) At reference conditions: ± 20 dBm +0.5 dB (CW), 1310 nm +1 nm, +23 C, 30 to 70 % rel. humidity (9/125 mm single mode fiber, DIN connector for OLP-130).
2) 30 to 70 % rel. humidity; ZEROING at measuring temperature, +0.5 C (bandwidth 0.5 Hz, wavelength 1300 to 1650 nm for OLP-150)
3) 30 to 70 % rel. humidity; modulation frequency 270 and 330 Hz; 1200 to 1650 nm for OLP-150.
4) When 50/125 mm multimode fibers are connected, the error specifications are valid only under mode equilibrium.
5) For measurements on multimode fibers, add +0.3 dB. ± 6) Add +0.007 dB at measurement values 4+17 dBm. ± 7) Add +0.015 dB at measurement values 4+17 dBm.
OLS-150 Optical Laser Source (Plug-in Module) Function . . . . . . . . . . . . . . . . . . . . . . . . . . continuous, bi-directional
Optical source type. . . . . . . . . . . . . . . Dual FP laser, Peltier-cooled, Insertion loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52.5 dB
both signals led through a coupler to a common output Repeatability of attenuation setting 1) . . . . . . . . . . . . . . . . . +0.1 dB
Wavelengths 1) . . . . . . . . . . . 1310 nm +15 nm / 1550 nm +15 nm (typically +0.05 dB)
Spectral bandwidth (RMS) . . . . . . . . . . . . . . . . . 52.5 nm / 54 nm 2)
Linearity . . . . . . . . . . +(0.2 dB +0.3% of attenuation value in dB)
Total attenuation uncertainty 3) . . . . . . . . . . . . . . . . . . . . . . +0.8 dB
Transmit operating modes
Unmodulated light Shutter isolation (pos. OFF) . . . . . . . .480 dB (typically 4100 dB)
CW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1310 nm or 1550 nm Monitor output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 dB tap
DUAL . . . . . . . . . . . . . . . . 1310 nm and 1550 nm simultaneously
Modulated light . . . . . . . . . . . . . . . . . . . . . . . 1310 nm or 1550 nm, Optical interfaces
modulated with 270 Hz, 330 Hz, Measuring adapter . . . . . . . . . for FC/PC, SC/PC, ST, DIN, E-2000...
1 kHz or 2 kHz (duty cycle 1:1, modulation depth 100%); Adapter BN 2060/00.xx
1310 nm (270 Hz) and 1550 nm (330 Hz) simultaneously Connectable fiber type . . . . . . . . . . . . . . . . . . . . . . . . 9/125 mm (SM)
Modulated light, WDM (both individually modulated Return loss . . . . . . . . . . . . . . . . . . . . . . . . .435 dB (typically 40 dB)
wavelengths are transmitted simultaneously) Max. input power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +20 dBm
Warm-up time to meet specifications . . . . . . . . . . . . . . . 5 minutes
Output power (power values per wavelength)
Traceability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to PTB
Unmodulated light . . . . . . . . . . . 0 dBm (laser class 1 to IEC 825-1)
Recommended calibration interval . . . . . . . . . . . . . . . . . . . . . . 1 year
Modulated light (average value) . . . . . . . . . . . . . . . . . . . . . ± 3 dBm
Setting range (level offset) . . . . . . . . . . . . . . . . . . . . +0.5 dB/±10 dB
Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01 dB General specifications
Dimensions (w6h6d) in mm . . . . . . . . . . . . . . . . 3861026288
Total output power uncertainty 2)
at nominal power (level offset 0 dB), Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 980 g
unmodulated and modulated light . . . . . . . . . ± 0.5 dB/+0.45 dB
for any arbitrary level offset, 1) Without disconnecting f.o. connectors, at constant ambient conditions, 30 to 70%
rel. humidity
unmodulated light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +0.6 dB 2) Without disconnecting f.o. connectors, deviation of used wavelength max. +50 nm
modulated light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +0.7 dB rel. to 1310 nm or 1550 nm, 30 to 70% rel. humidity.
3) Including DIN connectors, deviation of used wavelength max. +50 nm rel. to
Stability 1310 nm or 1550 nm, 30 to 70% rel. humidity. The total attenuation uncertainty
Short-term stability may increase by +0.3 dB (typically) for other connector types (FC, SC, ST).
(15 min, T = constant). . . . . . . . . . . . . . . . . . +0.005 dB (typical)
Long-term stability (6 h, DT = +3 K) . . . . . . . . . . . . . +0.05 dB

Optical interface OBR-100 Optical Back-Reflection Meter Module


Measuring adapter . . . . . . . . . . . . . . . . for FC/PC, SC/PC, ST, DIN, Wavelength range . . . . . . . . . . . . . . . . . . . . . . . . . . 1250 to 1600 nm
E-2000, etc., Adapter BN 2060/00.xx Display range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to ± 70 dB
Connectable fiber type . . . . . . . . . . . . . . . . . . . . . . . 9/125 mm (SM) Display units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . dB, %
to 100/140 mm (MM) Resolution
Warm-up time to meet specifications (T 5+40 C) . . . . . . . 1 hour Manual operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.001 dB
Traceability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to PTB Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.0001 dB
Recommended calibration interval . . . . . . . . . . . . . . . . . . . . . 1 year
Relative measurement uncertainty 1)
0 to ± 50 dB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - +0.25 dB
General specifications ± 50 to ± 60 dB 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - +0.35 dB
Dimensions (w6h6d) in mm. . . . . . . . . . . . . . . . . 3861026288 Total measurement uncertainty 1), 4)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750 g 0 to ± 50 dB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - +0.35 dB
± 50 to ± 60 dB 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - +0.45 dB
1) Measured center wavelength is indicated in the display. Reference reflector uncertainty . . . . . . . . . . . . . . . . . . . . . . . . +4 %
2) 30 to 70% rel. humidity, coupled into SM fiber (9/125 mm) via DIN connector.
Optical input/output
Source input . . . . . . . . . . . . . . . . . . . . . . . Adapter BN 2060/00.xx
Test port . . . . . . . . . . . . . . . . . Angled connector, interchangeable
OLA-150 Optical Attenuator (Plug-in Module) Fiber type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9/125 mm

Wavelength range General specifications


Setting range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1260 to 1600 nm
Dimensions (w6h6d) in mm . . . . . . . . . . . . . . . . 3861026288
Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 nm
Standard wavelengths. . . . . . . . . . . . . . . . . . . 1310 nm and 1550 nm Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 780 g
Recommended calibration interval . . . . . . . . . . . . . . . . . . . . . 1 year
Attenuation range
1260 to 1360 nm . . . . . . . . . . . . . . . . . . . . . . Insertion loss to 65 dB Accessories included:
1360 to 1600 nm . . . . . . . . . . . . . . . . . . . . . . Insertion loss to 60 dB Reference reflector and adapter for test port with various types
Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01 dB of connector: see OMS-150 ordering information.
Setting . . . . . . . absolute in dB or relative to reference value in dBr
1) For input levels 4
- ±10 dBm.
Setting time for any given attenuation value . . . . . . . . . . . . . . 53 s 2) Add 0.3 dB at measurement values 5±60 to ±65 dB.
Global Headquarters
20400 Observation Drive
Ordering Information Germantown, Maryland 20876-4023
USA
Toll Free 1-800-638-2049
OPT-150 Optical Options Tel +1-301-353-1550
Performance Tester BN 2207/15 Calibration report Fax +1-301-444-8468
www.acterna.com
(complete, consisting of OMS-150, OLP-150, OLS-150, (only when ordered with the module concerned)
OLA-150; measuring adapters to be ordered separately) for OLP-130/-150 BN 2201/00.01
for OLS-150 BN 2202/00.01
OMS-150 Mainframe BN 2207/05 for OLA-150 BN 2206/00.01 Regional Sales Headquarters
for OBR-100 BN 2232/90.02 North America
OMS-200 Mainframe BN 2241/01 20400 Observation Drive
Germantown, Maryland 20876-4023
ªOMS-200 remote operationº Accessories USA
software for Windows 95
Measuring adapters Toll Free 1-800-638-2049
To operate the optical modules, adapters for the connector Tel. +1-301-353-1550
Optical modules system are required (2 adapters for OBR-100, 3 adapters for
OLA-150, 1 adapter for OLS-150 and OLP-130/-150).
Fax +1-301-444-8468

(without measuring adapters):


for optical modules BN 2060/00.xx Latin America
Power Meter Modules for OLP-150 BN 2014/00.xx Av. Eng. Luis Carlos Berrini,
OLP-130 BN 2201/04 for OBR-100 (Test Port) 936-8/9. Andar
04571-000 S›o Paulo, SP
OLP-150 BN 2201/05 APC adapter BN 2060/00.5x
Brazil
Measuring Cables K 31xx, K 30xx Tel. +55 11 5503 3800
Fax +55 11 5505 1598
OLS-150 Optical Couplers S 31xx
Source Module BN 2202/05 For detailed ordering information refer to the
separate data sheet on optical adapters and cables. Asia-Pacific
42 Clarendon Street
SW drivers BN 2241/95.99
OLA-150 Optical (LabWindows DOS/CVI, LabVIEW, HP VEE, 3.5@ floppy disk)
PO Box 141
South Melbourne, Victoria 3205
Attenuator Module BN 2206/05 Optical connector cleaning tape BN 2229/90.07 Australia
Tel. +61 3 9690 6700
Connecting cable for IEC 625 interface bus K 420 Fax +61 3 9690 6750
OBR-100 Back-reflection (with IEEE 488 connectors, length 1.2 m)
Meter Module 1) BN 2232/01 RS232/V.24 interface cable K 764 Western Europe
(Zero modem, 2625-way/9way D connectors [f], Arbachtalstrasse 6
length 3 m) 72800 Eningen u.A.
Included with each OBR-100 ordered 2) : Germany
± Reference reflector with ABK-30 Storage case for Tel. +49 7121 86 2222
HRL-10/DIN connector BN 2232/90.01 optical accessories BN 2126/30 Fax +49 7121 86 1222
Test adapter HRL-10/DIN TPK-960/3 Carrying Case BN 960/00.05
for Test Port BN 2060/00.50 East Europe,
SD-930 Front and back panel Middle East & Africa
or
covers (OMS-150) BN 0960/00.01 Elisabethstrasse 36
± Reference reflector
PO Box 13
with FC-APC connector BN 2232/90.03 19@ rack mounting for OMS-150 BN 2203/00.07 2500 Baden
Test adapter FC-APC BN 2060/00.51 Austria
or Tel. +43 2252 85521 0
Fax +43 2252 80727
± Reference reflector
with SC-APC connector BN 2232/90.04 1st Neopalimovskiy Per. 15/7
(4th floor)
Test adapter SC-APC BN 2060/00.58 119121 Moscow
On request (not included Russia
Tel. +7 095 248 2508
in standard delivery package) Fax +7 095 248 4189
Reference reflector for OBR-100 BN 2232/90.0x
Acterna is present in more
than 80 countries. To find
1) Without measuring adapter your local sales office, go to
2) To be specified in order www.acterna.com

IEEE 488
IEC 625
RS-232
FO/EN/D156/0601/AE, repl. 1315

Note: Specifications, terms and conditions are subject to change


without prior notice
ã Copyright 2001 Acterna, LLC. All rights reserved.
Acterna, The Keepers of Communications, and its logo are
trademarks of Acterna, LLC. All other trademarks and registered
REG.NO 572 - 02
Acterna Eningen GmbH trademarks are the property of their respective owners.

You might also like