Cellular Plug-in Troubleshooting


Before Installing Cellular
Always verify the site has adequate cellular coverage prior to installing a cellular plug-in. SolarEdge Technical Support
cannot assist if a cellular plug-in has been installed in an area with unusable/non-existent cellular signal strength. You
can find coverage maps here: Sprint (CDMA and/or SetApp inverters) or Aeris (GSM and/or LCD screen inverters).

WARNING!
These troubleshooting steps require working inside the inverter. Never install a cellular plug-in or
any other hardware while AC power is connected to the inverter or damage may occur. Never open
the inverter if it is raining or if the inverter will be exposed to moisture. Always follow your company
safety protocols when working inside the inverter.

Verify You Are Installing the Correct Type of Plug-in


SetApp inverters will not work with cellular plug-ins intended for inverters with LCD screens and vice versa.
SetApp/Synergy compatible cellular plug-ins will have a ‘B’ in the Part Number. The inverter will not recognize the
cellular plug-in if the wrong type of card is used. Unfortunately, SolarEdge Technical Support cannot provide a
warranty replacement if the wrong plug-in is used.

Cellular plug-in appearance varies between LCD and SetApp compatible cards as well.

Installation
See the tutorial video available HERE for installation instructions. In most cases registration completes quickly, but
please allow up to 90 minutes for the cellular plug-in to register on the cellular network (depending on signal
strength and network traffic). Please allow up to 6 hours for the plug-in to upload data to the customer’s monitoring
portal.

Cellular Troubleshooting
See the steps below to troubleshoot possible cellular communication issues:

Sig 0 / Not Registered


TCP Connect Failure
Modem Not Recognized
Configuration Error
S_OK but No Data On Portal
No S_OK
Repeated Communication Failures

Cellular Plug-in Troubleshooting


2 Cellular Plug-in Troubleshooting

Sig 0 / Not Registered


This is normally seen after a cellular plug-in has been installed or if the cellular signal in the area is too low for reliable
cellular communications. It is most often seen in areas with poor signal. Update the inverter firmware to the newest
3.25xx CPU. After updating the firmware, perform the ‘Cellular Clean Install’ outlined below. After the reinstall, set the
Server to Cellular and run the Network Scan and Run Diagnostics available in the menu → Maintenance → Diagnostics
→ Cellular. Get pictures of the results and contact SolarEdge Technical Support if the issue does not resolve.

TCP Connect Failure


This message usually indicates the Cellular network is under load or maintenance. You can attempt to clear it by
setting the Server to LAN, exiting the menu completely, and then re-setting the Server to Cellular. If that fails you can
try the Cellular Clean Install as well. In the rare event the issue persists it may indicate a weak cellular signal, follow
the Sig 0 / Not Registered steps if that happens.

No Modem Detected / No Cellular Option


Most commonly caused by using a SetApp cellular plug-in in an inverter with LCD screen, or vice versa. Potentially
caused by installing the cellular plug-in with the AC power on. May also be caused by old firmware or a
communication board that needs to be rebooted or if the modem isn’t seated properly. Verify the correct type of
modem is in use. Try updating the inverter firmware and then performing the Cellular Clean Install below. If the issue
persists, contact SolarEdge Technical Support. Please have the IMSI/ICCID/or MEID of the cellular modem available.

Configuration Error
This message usually indicates a hold or block on the cellular data. Get the IMSI/ICCID/or MEID number from the
cellular modem (Menu → Information → Modem Info, then scroll down) and contact SolarEdge Technical Support.

S_OK but No Data On Portal


This message may indicate that the wrong inverter serial number has been entered on the customer’s Monitoring
Portal, or it may indicate incorrect firmware or software parameters. To verify the correct inverter serial number is in
use, check the ID# of the inverter on the screen or the Wi-Fi network name of the SetApp inverter (or the SN of the
inverter while logged into the SetApp). If the wrong serial number was entered onto the customer’s portal, correct it
using the logical layout. If the serial number is correct, please contact SolarEdge Technical Support.
Cellular Plug-in Troubleshooting 3

No S_OK
This can be an indication of weak cellular signal strength, server lag or maintenance, a need to update the firmware, a
need to reboot the communication board. To start, set the Server to LAN, exit the menu completely, then re-enter
the menu and set the Server back to Cellular. Do that a couple times, if no change in the S_OK status, update the
inverter firmware. If that fails, conduct the Sig 0 / Not Registered troubleshooting above and provide the Network
Scan and Run Diagnostics results to SolarEdge Technical Support.

Repeated Communication Drops


This message usually indicates sub-standard signal strength on site. Conduct the Sig 0 / Not Registered
troubleshooting and provide the Network Scan and Run Diagnostics results to SolarEdge Technical Support.

For SetApp inverters:

Cellular Clean Installation


Update the inverter firmware via MicroSD (LCD screen) or SetApp.
After the firmware update, set the Server to LAN. Exit the menu and shut the inverter down completely.
Ensure AC power is OFF.
Wait 60 seconds, then remove the cellular plug-in from the inverter and set it in a safe spot.
Turn ONLY the AC power – leave on for 60 seconds.
While waiting, get a picture of the Cellular plug-in, the SIMM card ICCID number (if using GSM) and inspect
your antenna connections to verify everything is secure.
After 60 seconds, shut down the AC again and reinstall the cellular plug-in.
After everything is reinstalled, turn on the AC power and set the Server back to Cellular.
Check the Server status screen after a few minutes to verify all is working properly.