TFL 8 Cable Fault Pre-locator

UNDERGROUND CABLE FAULT LOCATING EQUIPMENTS & SYSTEMS

Description
The Cable Fault Pre-locator TFL8 is a latest micro-processor Another Impulse Current method (ICM) is available and use
controlled, menu driven, digital technology to offer precise to for pre-location of low insulation or intermittent nature cable
locate fault distance in any type of metallic cables and easy faults by coupling with high voltage surge tester in low,
to operate with friendly interface. medium and high voltage cables.

It is a portable cable fault locator, easy to use, single-phase The maximum measuring ranges enable for pre-location of
unit for cable fault pre-location of short and open faults by cable faults is 100 km in different selectable ranges.
using the Low Voltage Impulse method / Time Domain
Reflection (TDR) method.

Application
It is used for pre-location of short circuit, open circuit fault distance in Low Voltage Impulse method and low insulation / high
resistance / flashing fault in Impulse Current method ICM with the help of suitable surge tester by power transmission,
distribution network companies and cable fault location service providers.

Features
Two selectable work mode Low Voltage Impulse method Communication with computer through USB port.
(TDR) & Impulse Current method (ICM).
Memory save through USB device for printing of store
Capable to locate faults in any type of metallic single core graph.
armored or multi-core armored cables.
Big 7" color LED screen,160° viewing angle.
Interactive menu-guidance operation with manual and
touch screen operation. Built-in Polymer Lithium-ion internal rechargeable battery
capable of working for maximum 5 hours continuously.
Maximum measuring range up to 100 km.
Gain and zoom adjustment facility.
Three windows for easy comparison in low impulse
method. Internal battery charge status.

Cursor drag function, easy to locate. Intelligent charger for charging of internal batteries.

Internal storage of waveforms. Compact, light weight and user friendly menu driven
operation.

TELEMETRICS

TELEMETRICS EQUIPMENTS PVT. LTD.


Working Principle
TDR Mode / Low Voltage Impulse Method ICM Mode
A narrow electromagnetic pulse of 5 nsec with a fast rise A Surge tester applies DC high voltage and high energy
time is sent on the cable that reflects back from the fault point surges across the fault to the cable under test that induces a
/ far end where the impedance was change. breakdown or flash over across the fault point in the cable and
the current transient is developed at the fault point .The
The velocity of propagation (VOP) for each cable depending transient waves travels back and forth between the surge
on the cable dimension and di-electric material is set. The tester and the fault point. The current transient is measured
distance to the fault is then computed automatically and using a current transformer with a frequency response
displayed in meters on screen. adequate to resolve only the edges of the current transient.
The distance to the fault is then computed automatically and
displayed in meters on screen.
UNDERGROUND CABLE FAULT LOCATING EQUIPMENTS & SYSTEMS

Standard Accessories
Low voltage Impulse (TDR) testing cable Software CD
Impulse current method (ICM)testing cable Carrying case
Re-chargeable battery charger / Adapter Instruction / User Manual

Standard Warranty One Year


Other models available Cable Fault Pre-locator TFL 6

Specifications
Operating Mode Low voltage impulse TDR and Resolution
Impulse current ICM TDR Mode 0.425 m

Measuring Range 100 km max ICM Mode 0.85 m

Low Voltage of 30 V Display 15.3 * 8.6CM


Transmitting
Pulse Dead Zone 2 meter

Width of Trans- 5ns Charging Input 230V AC, 50Hz, Current 2A


mitting Pulse Supply Voltage

Voltage Power : 1500V, Port : 50V Charger Output 8.4 V


Withstand Voltage

Output 30 Ohm Operation Time 5 Hours Approx


Impedance of Batteries

Sampling Freq. 200 MHZ Storage Temp. -20 Deg C ~ +60 Deg C

VOP Range 100 ~ 300 meter/sec Working Temp. -10 Deg C ~ +55 Deg C

Number of 100 Memories Dimensions 274 (L) × 240 (W) × 125 (H) mm
Echograms
Memories Weight 3.5 Kg Approx

Gain Range 0 - 70 dB Type of Protection Splash proof and dust protected IP 54


Optional - IP 65

Telemetra Systems Pvt. Ltd. Pune


5, Electronic Sadan II, MIDC, Bhosari, [email protected]
Pune - 411026 [email protected]
www.telemetrics.in Maharashtra, INDIA.
CIN
+91-20-27122936 / 27123176 11-045075
9011083682
Regional Offices
Kolkata Delhi Chennai
[email protected] [email protected] [email protected]
Specification subject to change without notice 09748487005 09654045183 09791715130

You might also like