Meril Diagnostics

Emerging from a lineage of successful business enterprise, Meril Diagnostics is an in-vitro diagnostic arm of the multi million dollar
MNC group .
Meril Diagnostic’s core objective is to design, manufacture and distribute, clinically relevant, state of the art and best in class analyzers
and reagents to alleviate human suffering and improve Quality of Life.

Corporate Office
Meril's corporate office sits proud ensconced within the serene hill sides of
Chala town; located 150 kms north of Mumbai at Vapi

Meril Park
300,000 sq feet state of the art manufacturing, research and development facility
located at Vapi for Diagnostics, Orthopaedics, Endo-surgery equipments and
Cardiovascular, comprising a team of designers, engineers, chemists,
microbiologists and R&D scientists.

Meril Training Academy


While innovations and advancements play a vital role in contributing towards better
health of the society, a larger role also lies in educating and imparting training to
pathologists, clinicians, technicians and other members of the medical fraternity.

Meril's Training Academy is a world class, first of its kind institution that offers both practicing professionals and students hands on
training and knowledge.
Modernistic, contemporary academy with Hands on Trainings, Simulators, Live Case Learning, Distance learning, Hard-ware play
rooms, Libraries, Cadaver and Animal models.
Throughput: Up to 200 Tests / hour for 2 reagents
Up to 240 Tests / hour for single reagent
Analysis Method : End Point, Fixed Time (2-point), Kinetic Rate-A, Kinetic Rate-B
Assay Modes : Colorimetric, Turbidimetry, Single and Double reagent, Multi standard,
Mono and Bi – Chromatic
Random Access with STAT function
Measurement Principle : Photometry
Sample Positions: Maximum 30 positions
30 onboard cooled reagent positions maintained by water cooled Peltier system
Auto positioning for bar coded reagents
60 dismountable, easily replaceable and reusable cuvettes
Total 9 filters (340, 405, 450, 510, 546, 578, 620, 660, 700)
Calibration Points: K-Factor, Linear, Logit-log 4P, Logit-log 5P, Spline, Exponential,
Polynomial Multipoint curves for up to 6 points
User defined calibration validation
User defined reflex testing
User defined forbidden pairs with 3 different types of wash
Special wash for cuvettes possible
Laundry System, 7-step automatic washing
Low water consumption of 5 - 6 litres / hour
Easy-to-use Windows based software (Windows XP /
Windows 7 / Windows 8)
is a fully automated, random access, patient Optical System
prioritized analyzer with throughput of up to 200 tests / hour for
double reagent and up to 240 tests / hour for single reagent, uses Halogen Tungsten lamp, with fibre optics
making it ideal for small to mid sized laboratory. and silicon photo-diode detector.
Photometric system of Static filters with total 9 filters (340, 405,
Sample and Reagent System – An Art of Simplicity 450, 510, 546, 578, 620, 660, 700)
is provided with 30 sampling positions with
Assay Modes
possibility of using bar codes sample tubes.
Continuous loading possible with STAT samples can be placed End Point, Fixed time (2-point), Kinetic Rate-A, Kinetic Rate-B.
at any free positions.
30 cooled reagent positions available with auto-positioning of Auto Re-run
MERIL reagents.
is programmed with auto execution according
to abnormal or substrate depleted marking.

Perfect Quality Control Function


Real time quality control based on Multi-rule method.
Within day as well as day-to-day X and X-R control diagram (L-J
Graphs). Mean, SD, %CV, R is calculated for all parameters for
sample replicates.
Enhanced Lab Efficiency
is equipped with sample and reagent probe
with liquid level sensor. Analyzer is programmed with internal and
external probe washing.
Analyzer is provided with long life pipetting system with plunger,
driven by stepper motor and is equipped with vertical and
horizontal obstruction detection facility to prevent probe crash.

Reaction Disk Assembly


Data Storage
is provided with 60
dismountable, easily replaceable and Test results: Umlimited
reusable cuvettes. Analyzer is Reaction curve: Unlimimted
equipped with laundry and 7-step Profiles: 20 per sample type
automatic washing system, with low Data search provided as patient wise, Test wise, Date wise,
water consumption of 5 - 6 litres / hour. Doctor/Hospital wise etc.
Throughput Double Reagent : 200 Tests / hour Calibration K-Factor, Linear (one, two and multi
Single Reagent : 240 Tests / hour point), Logit-log, Spline, Exponential,
System Functions Polynomial (second, third and fourth
Analysis Method End Point, Fixed Time (2-point), order)
Kinetic Rate-A, Kinetic Rate-B Calibration Points Multipoint curves for up to 6 points
Assay Modes Colorimetry, Turbidimetry, Single and Execution by repeat run list or auto
Double reagent, Multi standard, execution
Mono and Bi – Chromatic Auto re-run Auto execution according to abnormal
Sample / Reagent handling marking or range over
Sample Volume 2 - 70 µl 0.12 µl step
Data Storage Test results: 1,000,000
Sample Dilution Dilution ratio of 2 to 40
Reaction curve: 40,000 tests
Reagent Position 30 for R1 and R2
Profiles: 20 per sample type
Reagent Volume 180 - 550 µl
Within day as well as day =-to-day X and
X-R control diagram (L-J Graph)
Reaction System
Quality Control Real time quality control based on
Reaction Cuvette 60 (Dismountable)
Multi-rule method mean, SD, %CV, R is
Cuvette Washing On board laundry with 7 step
calculated for all parameters for
washing system
Water Consumption 5 - 6 litres / hour sample replicates
Optical length of cuvette 5 mm Working Conditions
Reaction Volume 180 - 550 µl Power Supply 110/220 VAC, 50/60 Hz
Reaction Time 300 to 600 sec (Depending on the (Max. Power 250 W)
designated cycle time and number Temperature 100C - 300C
of reagents) Humidity 40% - 80% free from water dew
Reaction Temperature 37 + 0.2 C formation
Optical System Operation System Windows XP or Windows 2007 or
Measurement Phoometry Input and Output Winfix
Light Source Halogen Tungsten lamp Input RS 232 interface/computer
Wavelength Total 9 filters (340, 405, 450, 510, Output Multi Format Printout
546, 578, 620, 660, 700) Dimensions 550 mm (W) x 420 mm (D) x 380 mm (H)
Absorbance Range 0 - 3.0 Abs
Weight Approx. 50 kgs
Resolution 0.0001 Abs
ALBAQ1-01 Albumin 6 x 20
AMYAQ1-01 Amylase 4 x 20
ALPAQ1-01 Alkaline Phosphatase 4 x 15
GPTAQ1-01 ALAT (GPT) 6 x 20 / 6 x 5
GOTAQ1-01 ASAT (GOT) 6 x 20 / 6 x 5
BITAQ1-01 Bilirubin Total 5 x 15 / 5 x 5
BIDAQ1-01 Bilirubin Direct 5 x 15 / 5 x 5
CAAAQ1-01 Calcium A 4 x 20
CREAQ1-02 Creatinine 5 x 15 / 5 x 15
CKNAQ1-01 Creatine Kinase NAC 2 x 20 / 2 x 5
CKMAQ1-01 Creatine Kinase MB 2 x 20 / 2 x 5
CHOAQ1-01 Cholesterol 6 x 20
CO3AQ2-01 Compliment 3 2 x 20 / 2 x 5
CO4AQ2-01 Compliment 4 2 x 20 / 2 x 5
HDLAQ1-01 HDL Cholesterol (Direct) 2 x 18 / 2 x 6
LDLAQ1-01 LDL Cholesterol (Direct) 1 x 18 / 1 x 6
CHDAQ1-01 Chloride 4 x 20
GGTAQ1-01 γ-Glutamyl Transferase 1 x 20 / 1 x 5
GLUAQ1-01 Glucose 10 x 20
LDHAQ1-01 Lactate Dehydrogenase 1 x 20 / 1 x 5
MAGAQ1-01 Magnesium 4 x 20
PHOAQ1-01 Phosphorous 4 x 20
TPRAQ1-01 Total Protein 6 x 15
MTPAQ1-01 Microprotein 4 x 20
TRGAQ1-01 Triglyceride 6 x 20
URCAQ1-01 Uric Acid 4 x 15
UREAQ1-01 Urea 6 x 20 / 6 x 5
ASOAQ2-01 Anti Streptolysin-O (ASO) 2 x 20 / 2 x 5
APAAQ2-01 Apolipoprotein A1 (APO A1) 2 x 20 / 2 x 5
APBAQ2-01 Apolipoprotein B (APO B) 2 x 20 / 2 x 5
HSCAQ2-01 CRP Ultra 2 x 20 / 2 x 5
MALAQ2-01 Micro Albumin (µ-ALB) 2 x 20 / 2 x 5

AQ200i/BROCHURE/20141120/V2.0/IND
RHFAQ2-01 Rheumatoid Factor (RF) 2 x 20 / 2 x 5
LPAAQ2-01 Lipoprotein(a) 2 x 20 / 2 x 5
CRPAQ2-01 C-Reactive Protein (CRP) 2 x 20 / 2 x 5
LIPAQ2-01 Lipase 1 x 20 / 1 x 12