EPCON C8

STANDARD EMBEDMENT - Zinc coated & stainless steel studs 1/12

Epoxy resin - High performance ETA


for use in cracked and European Technical Assessment
STAINLESS
STEEL

non-cracked concrete ETA Option 1- 10/0309

Technical data
Tinst df
Anchor size Min. Max. thick. Min. thick. Thread Drilling Drilling Clearance Total Tighten Code*
d d0 anchor of part to of base diameter depth diameter diameter anchor torque MAXIMA stud
depth be fixed material length
tfix hef = h0
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Nm) zinc stainless
L hef tfix hmin d hO dO df L Tinst coated st. steel A4
M8X110 80 15 110 8 80 10 9 110 10 050950 052400
hmin
M10X130 90 20 120 10 90 12 12 130 20 050960 052410
APPLICATION M12X160 110 25 140 12 110 14 14 160 30 050970 052420
M16X190 125 35 160 16 125 18 18 190 60 050980 052440
 Steel profiles M20X260 170 65 220 20 170 25 22 260 120 655220 052450
 Fixing machinery (resistant to M24X300 210 63 265 24 210 28 26 300 200 655240 052470
vibration) M30X380 280 70 350 30 280 35 33 380 400 050940 -
 Storage tanks, pipes
EPCON C8 Epoxy resin, dual component cartridge 450 ml 055887
 Signs
EPCON C8 Epoxy resin, dual component cartridge 900 ml 055829
 Guard rails
* These are Maxima studs, for standard studs (zinc coated or stainless steel versions) see catalogue.
 Electrical insulated fixings

MATERIAL Anchor mechanical properties


Zinc coated steel version : Anchor size M8 M10 M12 M16 M20 M24 M30
 Stud M8-M16 : MAXIMA stud - zinc coated steel version
Steel cold form steel NF A35-053 fuk (N/mm2) Min. tensile strength 600 600 600 600 520 520 520
 Stud M20-M30 : fyk (N/mm2) Yield strength 420 420 420 420 420 420 420
11 SMnPb37 - NFA 35-561 M0rk,s (Nm) Characteristic bending moment 22 45 79 200 301 520 1052
 Nut : Steel grade 6 or 8 M (Nm) Recommended bending moment 11,0 22,5 39,5 100 150 160 525
NF EN 20898-2 MAXIMA stud - stainless steel A4 version
 Washer : Steel DIN 513 fuk (N/mm2) Min. tensile strength 700 700 700 700 700 700 -
 Protection : zinc coated 5 μm min. fyk (N/mm2) Yield strength 350 350 350 350 350 350 -
NF E25-009 M0rk,s (Nm) Characteristic bending moment 26 52 92 233 454 786 -
M (Nm) Recommended bending moment 12 23 42 122 206 357 -
Stainless steel version : As (mm2) Stressed cross-section 36,6 58 84,3 157 227 326,9 -
 Stud : A4-70 as per ISO 3506-1 Wel (mm3) Elastic section modulus 31,2 62,3 109,2 277,5 482,4 833,7 -
 Nut : Stainless steel A4-80,
NF EN 10088-3
 Washer : Stainless steel A4, Setting time
NF EN 20898-2 Ambient temperature Max. time Waiting time Curing time
for installation for 45 % load
(min) (h) (h)
INSTALLATION* 40°C 5 3 6
30°C 8 5 8
20°C 14 6 12
10°C 20 12 23
5°C 26 15 26
Effect of temperature on

100%

x2 80%
the resistance

60%
40%
20%
x2
0%
20 40 60 80 100 120 140

x2 Temperature of the fixing(°C)

Chemical resistance of the SPIT EPCON C8 resin


Chemical substances Concentration Resistance Chemical substances Concentration Resistance
(%) (%)
Sulfuric acid 10 (o) Toluene (o)
Hydrochloric acid 10 (o) Ethanol (o)
Nitric acid 10 (o) Methyl-ethyl-ketone (MEK) (-)
Acetic acid 10 (o) Methanol (-)
Ammonium hydroxide 10 (o) Demineralized water (+)
Sodium Hypochlorite 5 (o) Sea water 100 (+)
*Premium cleaning : Sodium hydroxide 50 (o) Engine Petrol 100 (+)
- 2 blowing with compressed air Acetone (-) Motor oil 100 (+)
- 2 brushing with brushed fitted on a drilling machine Resistant (+): the samples in contact with the substances did not show any Screwible damage such as cracks, attacked surfaces, burst
- 2 blowing with compressed air corners nor large swelling. Sensitive (o): use with care regarding exposure of the field of usage, precautions to be taken. The samples in
82 contact with the substance slightly attacked the material.
EPCON C8
2/12 STANDARD EMBEDMENT - Zinc coated & stainless steel studs

The loads specified on this page allow judging the product’s performances, but cannot be used for the designing.
The data given in the pages “CC method” have to be applied (3/10 to 10/10).

Number of sealings per cartridge


Anchor size M8 M10 M12 M16 M20 M24 M30
Drilling diameter (mm) 10 12 14 18 25 28 35
Drilling depth (mm) 80 90 110 125 170 210 280
Number of sealings per cartridge
EPCON C8 450 ml 166 121 83 56 12 11 5
EPCON C8 900 ml 331 241 167 112 25 22 10

Ultimate (NRu,m, VRu,m) and characteristic loads (NRk, VRk) in kN


Mean Ultimate loads are derived from test results in admissible service conditions, and characteristic loads are statistically determined.

TENSILE SHEAR
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
Non-cracked concrete VRu,m 15,9 22,75 32,8 56,2 73,6 115,0 177,7
hef 80 90 110 125 170 210 280 VRk 11,0 18,9 25,3 46,8 59,02 95,8 135,9
NRu,m 39,4 55,5 81,2 115,0 183,5 257,7 403,8
NRk 32,1 45,2 66,2 93,8 149,8 211,4 330,5
Cracked concrete
hef 80 90 110 125 170 210 280
NRu,m 27,0 37,7 55,1 82,5 139,4 205,4 340,4
NRk 20,8 29,1 42,3 63,6 107,3 157,9 261,3

Design loads (NRd, VRd) for one anchor without edge or spacing influence in kN
NRk * *Derived from test results
VRk *
NRd = VRd =
Mc Ms
(stud grade 10.9)
TENSILE SHEAR
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
Non-cracked concrete VRd 7,7 13,2 17,7 32,7 39,3 63,9 90,6
hef 80 90 110 125 170 210 280 Ms = 1,43 for M8 to M16 and Ms = 1,5 for M20 to M30
NRd 17,8 25,1 36,8 52,1 83,2 117,4 183,6
Cracked concrete
hef 80 90 110 125 170 210 280
NRd 11,6 16,1 23,5 35,3 59,6 87,7 145,1
Mc = 1,8

Recommended loads (Nrec, Vrec) for one anchor without edge or spacing influence in kN
NRk * *Derived from test results
VRk *
Nrec = Vrec =
M F M F
(stud grade 10.9)

TENSILE SHEAR

Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
Non-cracked concrete Vrec 5,5 9,4 12,6 23,4 28,1 45,6 64,7
hef 80 90 110 125 170 210 280 F= 1,4 ; Ms = 1,43 for M8 to M16 and Ms = 1,5 for M20 to M30
Nrec 12,7 17,9 26,3 37,2 59,4 83,8 131,1
Cracked concrete
hef 80 90 110 125 170 210 280
Nrec 8,3 11,5 16,7 25,2 42,5 62,6 103,6
Mc = 1,8 83
EPCON C8
STANDARD EMBEDMENT - Zinc coated & stainless steel studs 3/12

SPIT CC Method (values issued from ETA)


TENSILE in kN SHEAR in kN
N ¬ Pull-out resistance ¬ Concrete edge resistance
for dry and wet concrete (1) V

NRd,p = N0Rd,p . fb VRd,c = V0Rd,c . fb . fV . S-C,V

V0Rd,c Design concrete edge resistance


N0Rd,p Design pull-out resistance at minimum edge distance (Cmin)
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
hef 80 90 110 125 170 210 280 hef 80 90 110 125 170 210 280
Non-cracked concrete 17,9 25,1 36,9 52,4 83,1 114,4 190,6 Cmin 40 50 60 80 100 120 150
Cracked concrete 10,6 14,9 20,7 29,7 50,4 74,8 102,6 Smin 40 50 60 80 100 120 150
Mc = 1,8 Non-cracked concrete 2,5 3,8 5,5 9,4 15,4 21,9 34,6
Cracked concrete 1,8 2,7 3,9 6,7 11 15,6 24,7
Mc = 1,5
N
¬ Concrete cone resistance V
for dry and wet concrete (1) ¬ Pryout failure
NRd,c = N0Rd,c . fb . s . c,N VRd,cp = V0Rd,cp . fb . s . c,N
N0Rd,c Design cone resistance V0Rd,cp Design pryout resistance
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
hef 80 90 110 125 170 210 280 hef 80 90 110 125 170 210 280
Non-cracked concrete 20,0 23,9 32,3 39,1 62,1 85,2 131,2 Non-cracked concrete 35,7 47,8 64,6 78,3 124,1 170,4 262,4
Cracked concrete 14,3 17,1 23,1 28,0 44,3 60,9 93,7 Cracked concrete 21,2 29,8 41,5 55,9 88,7 121,7 187,4
Mc = 1,8 Mcp = 1,5

¬ Steel resistance V ¬ Steel resistance

NRd,s Steel design tensile resistance VRd,s Steel design shear resistance
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
MAXIMA stud Zn. 12,9 20,5 29,8 55,6 79,2 114,1 182,6 MAXIMA stud Zn. 7,7 12,2 17,7 32,9 39,3 56,7 90,7
MAXIMA stud A4 12,3 19,8 28,9 54,5 85,0 122,5 - MAXIMA stud A4 7,3 11,9 17,3 32,7 51,3 73,1 -
Std. stud grade 5.8* 12,0 19,3 28,0 52,0 81,3 118,0 186,7 Std. stud grade 5.8* 7,4 11,6 16,9 31,2 48,8 70,4 112,0
Std. stud grade 8.8* 19,3 30,7 44,7 84,0 130,7 188,0 299,3 Std. stud grade 8.8* 11,7 18,6 27,0 50,4 78,4 112,8 179,2
Std. stud grade 10.9* 26,4 41,4 60,0 112,1 175,0 252,1 400,7 Std. stud grade 10.9* 12,2 19,3 28,1 52,0 81,3 117,3 186,7
MAXIMA stud Zn. : Ms = 1,71 for M8 to M16 and Ms = 2,49 for M20 to M30 MAXIMA stud Zn. : Ms = 1,43 for M8 to M16 and Ms = 1,5 for M20 to M30
MAXIMA stud A4 : Ms = 1,87 MAXIMA stud A4 : Ms = 1,56
Std. stud grade 5.8 and 8.8 : Ms = 1,5 and grade 10.9 : Ms = 1,4 Std. stud grade 5.8 and 8.8 : Ms = 1,25 and grade 10.9 : Ms = 1,5
* Special grade available on request. * Special grade available on request.
(1) The concrete in the area of the anchorage is water statured. The anchor may be installed
in flooded holes, but the figures above cannot be used, you must use the values given in the
ETA for the category 2.

NRd = min(NRd,c ; NRd,s) VRd = min(VRd,c ; VRd,s)


N = NSd / NRd  1 V = VSd / VRd  1

N + V  1,2
fb INFLUENCE OF CONCRETE f,V INFLUENCE OF SHEAR LOADING DIRECTION
90˚
60°≤ β
Concrete class fb Angle [°] f,V ≤1
80° ≤9
0° V
C25/30 1,02 0 to 55 1
β


90°

≤β

C30/40 1,08 60 1,1


β
≤60°

C40/60 1,10 70 1,2 180˚ 0˚

C50/60 1,12 80 1,5


90 to 180 2 c
84
EPCON C8
4/12 STANDARD EMBEDMENT - Zinc coated & stainless steel studs

SPIT CC Method (values issued from ETA)


s INFLUENCE OF SPACING FOR CONCRETE CONE RESISTANCE IN TENSILE LOAD

N SPACING S Reduction factor s SPACING S Reduction factor s


Cracked & non-cracked concrete Cracked & non-cracked concrete
Anchor size M8 M10 M12 M16 Anchor size M20 M24 M30
40 0,58 100 0,60
50 0,60 0,59 120 0,62 0,60
60 0,63 0,61 0,59 0,58 150 0,65 0,62 0,59
s 80 0,67 0,65 0,62 0,61 180 0,68 0,64 0,61
100 0,71 0,69 0,65 0,63 200 0,70 0,66 0,62
s
s = 0,5 + 150 0,81 0,78 0,73 0,70 250 0,75 0,70 0,65
6.hef 200 0,92 0,87 0,80 0,77 350 0,84 0,78 0,71
smin < s < scr,N 250 1,00 0,96 0,88 0,83 450 0,94 0,86 0,77
300 1,00 0,95 0,90 510 1,00 0,90 0,80
scr,N = 3.hef
330 1,00 0,94 630 1,00 0,88
S must be used for each spacing
influenced the anchors group. 375 1,00 750 1,00 0,95
840 1,00

c,N INFLUENCE OF EDGE FOR CONCRETE CONE RESISTANCE IN TENSILE LOAD

N EDGE C Reduction factor c,N EDGE C Reduction factor c,N


Cracked & non-cracked concrete Cracked & non-cracked concrete
Anchor size M8 M10 M12 M16 Anchor size M20 M24 M30
40 0,50 100 0,54
50 0,56 0,53 120 0,60 0,54
c 60 0,63 0,58 0,52 150 0,69 0,61 0,52
80 0,75 0,69 0,61 0,57 180 0,78 0,68 0,57
c 120 1,00 0,92 0,80 0,73 200 0,84 0,73 0,61
c,N = 0,25 + 0,5 . 135 1,00 0,86 0,79 255 1,00 0,86 0,71
hef 165 1,00 0,91 315 1,00 0,81
cmin < c < ccr,N
ccr,N = 1,5.hef 190 1,00 420 1,00
c,N must be used for each distance
influenced the anchors group.

s-c,V INFLUENCE OF SPACING AND EDGE DISTANCE FOR CONCRETE EDGE RESISTANCE IN SHEAR LOAD

¬ For single anchor fastening


Reduction factor s-c,V
Cracked & non-cracked concrete
C
1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2
V Cmin

h>1,5.c
s-c,V 1,00 1,31 1,66 2,02 2,41 2,83 3,26 3,72 4,19 4,69 5,20 5,72


c c ¬ For 2 anchors fastening
s-c,V = .
cmin cmin Reduction factor s-c,V
Cracked & non-cracked concrete
s C
S Cmin 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2
Cmin
1,0 0,67 0,84 1,03 1,22 1,43 1,65 1,88 2,12 2,36 2,62 2,89 3,16
1,5 0,75 0,93 1,12 1,33 1,54 1,77 2,00 2,25 2,50 2,76 3,03 3,31
V 2,0 0,83 1,02 1,22 1,43 1,65 1,89 2,12 2,38 2,63 2,90 3,18 3,46
2,5 0,92 1,11 1,32 1,54 1,77 2,00 2,25 2,50 2,77 3,04 3,32 3,61
h>1,5.c
3,0 1,00 1,20 1,42 1,64 1,88 2,12 2,37 2,63 2,90 3,18 3,46 3,76
3,5 1,30 1,52 1,75 1,99 2,24 2,50 2,76 3,04 3,32 3,61 3,91


3.c + s c 4,0 1,62 1,86 2,10 2,36 2,62 2,89 3,17 3,46 3,75 4,05
s-c,V = .
6.cmin cmin 4,5 1,96 2,21 2,47 2,74 3,02 3,31 3,60 3,90 4,20
5,0 2,33 2,59 2,87 3,15 3,44 3,74 4,04 4,35
s1
s2 5,5 2,71 2,99 3,28 3,71 4,02 4,33 4,65
s3
6,0 2,83 3,11 3,41 3,71 4,02 4,33 4,65
sn-1

¬ For 3 anchors fastening and more


3.c + s1 + s2 + s3 +....+ sn-1 c
V
s-c,V = .
3.n.cmin cmin
h>1,5.c
85
EPCON C8
STANDARD EMBEDMENT - Zinc coated & stainless steel studs 5/12

SPIT CC Method (values issued from ETA - Seismic category C1)


TENSILE in kN SHEAR in kN

N
¬ Pull-out resistance V ¬ Concrete edge resistance

NRd,p,C1 = N0Rd,p,C1 . fb VRd,c,C1 = V0Rd,c,C1 . fb . fV . S-C,V


V0Rd,c,C1 Design concrete edge resistance
at minimum edge distance (Cmin)
N0Rd,p,C1 Design pull-out resistance Anchor size M10 M12 M16
Anchor size M10 M12 M16 Category C1 - Single anchor
Category C1 - Single anchor hef 90 110 125
hef 90 110 125 Cmin 50 60 80
N0Rd,p,C1 (C20/25) 9,7 13,1 23,7 Smin 45 55 65
0
V Rd,c,C1 (C20/25) 3,8 5,5 9,4
Category C1 - Group of anchors (1)
Category C1 - Group of anchors (1)
hef 90 110 125
N0Rd,p,C1 (C20/25) 8,2 11,1 20,2 hef 90 110 125
(1) when more than one anchor of the group is submitted to tensile load Cmin 50 60 80
Mc = 1,8 Smin 45 55 65
V0Rd,c,C1 (C20/25) 3,3 4,7 8,0
(1) when more than one anchor of the group is submitted to shear load
Mc = 1,5
N
V
¬ Concrete cone resistance ¬ Pryout failure

NRd,c,C1 = N0Rd,c,C1 . fb . s . c,N VRd,cp,C1 = V0Rd,cp,C1 . fb . s . c,N

N0Rd,c,C1 Design cone resistance V0Rd,cp,C1 Design pryout resistance


Anchor size M10 M12 M16 Anchor size M10 M12 M16
Category C1 - Single anchor Category C1 - Single anchor
hef 90 110 125 hef 90 110 125
N0Rd,c,C1 (C20/25) 9,4 12,4 19,0 V0Rd,cp,C1 (C20/25) 22,6 29,7 45,6
Category C1 - Group of anchors (1) Category C1 - Group of anchors (1)
hef 90 110 125 hef 90 110 125
N0Rd,c,C1 (C20/25) 8,3 10,9 16,8 V0Rd,cp,C1 (C20/25) 20,0 26,2 40,2
(1) when more than one anchor of the group is submitted to tensile load (1) when more than one anchor of the group is submitted to shear load
Mc = 1,8 Mc = 1,5

V
¬ Steel resistance (2)
N

¬ Steel resistance
VRd,s,C1 Steel design shear resistance
Anchor size M10 M12 M16
Category C1 - Single anchor
NRd,s,C1 Steel design tensile resistance MAXIMA stud Zn. 8,5 12,4 23,0
MAXIMA stud A4 12,8 19,2 35,3
Anchor size M10 M12 M16 Std. stud grade 5.8 8,1 11,8 21,8
MAXIMA stud Zn. 20,5 29,8 55,6 Std. stud grade 8.8 18,6 27,0 50,4
MAXIMA stud A4 21,9 31,6 58,8 Category C1 - Group of anchors (1)
Std. stud grade 5.8 19,3 28,0 52,0 MAXIMA stud Zn. 7,2 10,5 19,6
Std. stud grade 8.8 30,7 44,7 84,0 MAXIMA stud A4 10,9 16,3 30,0
(1) when more than one anchor of the group is submitted to tensile load
Std. stud grade 5.8 6,9 10,0 18,6
MAXIMA stud Zn. : Ms = 1,8 and MAXIMA stud A4: Ms = 1,87 Std. stud grade 8.8 15,8 22,9 42,8
Std. stud grade 5.8 and 8.8 : Ms = 1,5 (1) when more than one anchor of the group is submitted to shear load
(2) In case of no hole clearance between anchor and fixture.
MAXIMA stud Zn. : Ms = 1,43 and MAXIMA stud A4 : Ms = 1,56
Std. stud grade 5.8 and 8.8 : Ms = 1,25

NRd,C1 = min(NRd,p,C1 ; NRd,c,C1 ; NRd,s,C1) VRd,C1 = min(VRd,c,C1 ; VRd,cp,C1 ; VRd,s,C1)


N = NSd / NRd,C1  1 V = VSd / VRd,C1  1

N + V  1,2
fb INFLUENCE OF CONCRETE f,V INFLUENCE OF SHEAR LOADING DIRECTION
90˚
60°≤ β
Concrete class fb Angle [°] f,V 80° ≤9 V
≤1 0°
C25/30 1,02 0 to 55 1
β


90°

C30/40 1,08 60 1,1


≤β

β
≤60°

C40/60 1,10 70 1,2 180˚ 0˚


C50/60 1,12 80 1,5
90 to 180 2
86 c
EPCON C8
6/12 Seismic calculation with I-EXPERT software

87
EPCON C8
EMBEDMENT 12Ø - Zinc coated & stainless steel studs 7/12

SPIT CC Method (values issued from ETA)


TENSILE in kN SHEAR in kN
N ¬ Pull-out resistance ¬ Concrete edge resistance
for dry and wet concrete (1) V

NRd,p = N0Rd,p . fb VRd,c = V0Rd,c . fb . fV . S-C,V

V0Rd,c Design concrete edge resistance


N0Rd,p Design pull-out resistance at minimum edge distance (Cmin)
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
hef 95 120 144 192 220 280 330 hef 95 120 144 192 220 280 330
Non-cracked concrete 21,2 33,5 48,3 80,4 107,5 152,5 224,6 Cmin 40 50 60 80 100 120 150
Cracked concrete 12,6 19,9 27,1 45,6 65,3 99,7 121,0 Smin 40 50 60 80 100 120 150
Mc = 1,8 Non-cracked concrete 2,6 3,5 5,1 7,5 12,7 18,9 32,2
Cracked concrete 1,8 2,5 3,6 5,3 9 13,5 23
Mc = 1,5
N
¬ Concrete cone resistance V
for dry and wet concrete (1) ¬ Pryout failure
NRd,c = N0Rd,c . fb . s . c,N VRd,cp = V0Rd,cp . fb . s . c,N
N0Rd,c Design cone resistance V0Rd,cp Design pryout resistance
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
hef 95 120 144 192 220 280 330 hef 95 120 144 192 220 280 330
Non-cracked concrete 25,9 36,8 48,4 74,5 91,4 131,2 167,9 Non-cracked concrete 42,4 67,0 96,5 149,0 182,7 262,4 335,7
Cracked concrete 18,5 26,3 34,6 53,2 65,3 93,7 119,9 Cracked concrete 25,2 39,8 54,3 91,1 130,5 187,4 239,8
Mc = 1,8 Mcp = 1,5

¬ Steel resistance V ¬ Steel resistance

NRd,s Steel design tensile resistance VRd,s Steel design shear resistance
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
MAXIMA stud Zn. 12,9 20,5 29,8 55,6 79,2 114,1 182,6 MAXIMA stud Zn. 7,7 12,2 17,7 32,9 39,3 56,7 90,7
MAXIMA stud A4 12,3 19,8 28,9 54,5 85,0 122,5 - MAXIMA stud A4 7,3 11,9 17,3 32,7 51,3 73,1 -
Std. stud grade 5.8* 12,0 19,3 28,0 52,0 81,3 118,0 186,7 Std. stud grade 5.8* 7,4 11,6 16,9 31,2 48,8 70,4 112,0
Std. stud grade 8.8* 19,3 30,7 44,7 84,0 130,7 188,0 299,3 Std. stud grade 8.8* 11,7 18,6 27,0 50,4 78,4 112,8 179,2
Std. stud grade 10.9* 26,4 41,4 60,0 112,1 175,0 252,1 400,7 Std. stud grade 10.9* 12,2 19,3 28,1 52,0 81,3 117,3 186,7
MAXIMA stud Zn. : Ms = 1,71 for M8 to M16 and Ms = 2,49 for M20 to M30 MAXIMA stud Zn. : Ms = 1,43 for M8 to M16 and Ms = 1,5 for M20 to M30
MAXIMA stud A4 : Ms = 1,87 MAXIMA stud A4 : Ms = 1,56
Std. stud grade 5.8 and 8.8 : Ms = 1,5 and grade 10.9 : Ms = 1,4 Std. stud grade 5.8 and 8.8 : Ms = 1,25 and grade 10.9 : Ms = 1,5
* Special grade available on request. * Special grade available on request.
(1) The concrete in the area of the anchorage is water statured. The anchor may be installed
in flooded holes, but the figures above cannot be used, you must use the values given in the
ETA for the category 2.

NRd = min(NRd,p ; NRd,c ; NRd,s) VRd = min(VRd,c ; VRd,cp ; VRd,s)


N = NSd / NRd  1 V = VSd / VRd  1

N + V  1,2
fb INFLUENCE OF CONCRETE f,V INFLUENCE OF SHEAR LOADING DIRECTION
90˚
60°≤ β
Concrete class fb Angle [°] f,V ≤1
80° ≤9
0° V
C25/30 1,02 0 to 55 1
β


90°

≤β

C30/40 1,08 60 1,1


β
≤60°

C40/60 1,10 70 1,2 180˚ 0˚

C50/60 1,12 80 1,5


90 to 180 2 c
88
EPCON C8
8/12 Zinc coated & stainless steel studs - EMBEDMENT 12Ø

SPIT CC Method (values issued from ETA)


s INFLUENCE OF SPACING FOR CONCRETE CONE RESISTANCE IN TENSILE LOAD

N SPACING S Reduction factor s SPACING S Reduction factor s


Cracked & non-cracked concrete Cracked & non-cracked concrete
Anchor size M8 M10 M12 M16 Anchor size M20 M24 M30
40 0,57 100 0,58
50 0,59 0,57 120 0,59 0,57
60 0,61 0,58 0,57 0,55 150 0,61 0,59 0,58
s 80 0,64 0,61 0,59 0,57 180 0,64 0,61 0,59
100 0,68 0,64 0,62 0,59 200 0,65 0,62 0,60
s
s = 0,5 + 150 0,76 0,71 0,67 0,63 250 0,69 0,65 0,63
6.hef 200 0,85 0,78 0,73 0,67 300 0,73 0,68 0,65
smin < s < scr,N 290 1,00 0,90 0,84 0,75 400 0,80 0,74 0,70
360 1,00 0,92 0,81 500 0,88 0,80 0,75
scr,N = 3.hef
435 1,00 0,88 660 1,00 0,89 0,83
S must be used for each spacing
influenced the anchors group. 580 1,00 840 1,00 0,92
990 1,00

c,N INFLUENCE OF EDGE FOR CONCRETE CONE RESISTANCE IN TENSILE LOAD

N EDGE C Reduction factor c,N EDGE C Reduction factor c,N


Cracked & non-cracked concrete Cracked & non-cracked concrete
Anchor size M8 M10 M12 M16 Anchor size M20 M24 M30
40 0,46 100 0,48
50 0,51 0,46 120 0,52 0,46
c 60 0,57 0,50 0,46 150 0,59 0,52 0,48
80 0,67 0,58 0,53 0,46 200 0,70 0,61 0,55
c 145 1,00 0,85 0,75 0,63 250 0,82 0,70 0,63
c,N = 0,25 + 0,5 . 180 1,00 0,88 0,72 330 1,00 0,84 0,75
hef
cmin < c < ccr,N 215 1,00 0,81 420 1,00 0,89
ccr,N = 1,5.hef 290 1,00 500 1,00
c,N must be used for each distance
influenced the anchors group.

s-c,V INFLUENCE OF SPACING AND EDGE DISTANCE FOR CONCRETE EDGE RESISTANCE IN SHEAR LOAD

¬ For single anchor fastening


Reduction factor s-c,V
Cracked & non-cracked concrete
C
1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2
V Cmin

h>1,5.c
s-c,V 1,00 1,31 1,66 2,02 2,41 2,83 3,26 3,72 4,19 4,69 5,20 5,72


c c ¬ For 2 anchors fastening
s-c,V = .
cmin cmin Reduction factor s-c,V
Cracked & non-cracked concrete
s C
S Cmin 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2
Cmin
1,0 0,67 0,84 1,03 1,22 1,43 1,65 1,88 2,12 2,36 2,62 2,89 3,16
1,5 0,75 0,93 1,12 1,33 1,54 1,77 2,00 2,25 2,50 2,76 3,03 3,31
V 2,0 0,83 1,02 1,22 1,43 1,65 1,89 2,12 2,38 2,63 2,90 3,18 3,46
2,5 0,92 1,11 1,32 1,54 1,77 2,00 2,25 2,50 2,77 3,04 3,32 3,61
h>1,5.c
3,0 1,00 1,20 1,42 1,64 1,88 2,12 2,37 2,63 2,90 3,18 3,46 3,76
3,5 1,30 1,52 1,75 1,99 2,24 2,50 2,76 3,04 3,32 3,61 3,91


3.c + s c 4,0 1,62 1,86 2,10 2,36 2,62 2,89 3,17 3,46 3,75 4,05
s-c,V = .
6.cmin cmin 4,5 1,96 2,21 2,47 2,74 3,02 3,31 3,60 3,90 4,20
5,0 2,33 2,59 2,87 3,15 3,44 3,74 4,04 4,35
s1
s2 5,5 2,71 2,99 3,28 3,71 4,02 4,33 4,65
s3
6,0 2,83 3,11 3,41 3,71 4,02 4,33 4,65
sn-1

¬ For 3 anchors fastening and more


3.c + s1 + s2 + s3 +....+ sn-1 c
V
s-c,V = .
3.n.cmin cmin
h>1,5.c
89
EPCON C8
EMBEDMENT 16Ø - Zinc coated & stainless steel studs 9/12

SPIT CC Method (values issued from ETA)


TENSILE in kN SHEAR in kN
N ¬ Pull-out resistance ¬ Concrete edge resistance
for dry and wet concrete (1) V

NRd,p = N0Rd,p . fb VRd,c = V0Rd,c . fb . fV . S-C,V

V0Rd,c Design concrete edge resistance


N0Rd,p Design pull-out resistance at minimum edge distance (Cmin)
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
hef 128 160 192 256 320 384 480 hef 128 160 192 256 320 384 480
Non-cracked concrete 28,6 44,7 64,3 107,2 156,4 209,1 326,7 Cmin 40 50 60 80 100 120 150
Cracked concrete 17,0 26,5 36,2 60,8 94,9 136,7 175,9 Smin 40 50 60 80 100 120 150
Mc = 1,8 Non-cracked concrete 2,8 3,7 5,4 7,9 13,7 20,2 34,7
Cracked concrete 2,0 2,6 3,8 5,6 9,7 14,4 24,7
Mc = 1,5
N
¬ Concrete cone resistance V
for dry and wet concrete (1) ¬ Pryout failure
NRd,c = N0Rd,c . fb . s . c,N VRd,cp = V0Rd,cp . fb . s . c,N
N0Rd,c Design cone resistance V0Rd,cp Design pryout resistance
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
hef 128 160 192 256 320 384 480 hef 128 160 192 256 320 384 480
Non-cracked concrete 40,5 56,7 74,5 114,7 160,3 210,7 294,5 Non-cracked concrete 57,2 89,4 128,7 214,5 312,8 418,2 588,9
Cracked concrete 29,0 40,5 53,2 81,9 114,5 150,5 210,3 Cracked concrete 34,0 53,1 72,4 121,5 189,9 273,4 351,9
Mc = 1,8 Mcp = 1,5

¬ Steel resistance V ¬ Steel resistance

NRd,s Steel design tensile resistance VRd,s Steel design shear resistance
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
Std. stud grade 5.8* 12,0 19,3 28,0 52,0 81,3 118,0 186,7 Std. stud grade 5.8* 7,4 11,6 16,9 31,2 48,8 70,4 112,0
Std. stud grade 8.8* 19,3 30,7 44,7 84,0 130,7 188,0 299,3 Std. stud grade 8.8* 11,7 18,6 27,0 50,4 78,4 112,8 179,2
Std. stud grade 10.9* 26,4 41,4 60,0 112,1 175,0 252,1 400,7 Std. stud grade 10.9* 12,2 19,3 28,1 52,0 81,3 117,3 186,7
Std. stud grade 5.8 and 8.8 : Ms = 1,5 Std. stud grade 5.8 and 8.8 : Ms = 1,25
Std. stud grade 10.9 : Ms = 1,4 Std. stud grade 10.9 : Ms = 1,5
* Special grade available on request. * Special grade available on request.

(1) The concrete in the area of the anchorage is water statured. The anchor may be installed
in flooded holes, but the figures above cannot be used, you must use the values given in the
ETA for the category 2.

NRd = min(NRd,p ; NRd,c ; NRd,s) VRd = min(VRd,c ; VRd,cp ; VRd,s)


N = NSd / NRd  1 V = VSd / VRd  1

N + V  1,2
fb INFLUENCE OF CONCRETE f,V INFLUENCE OF SHEAR LOADING DIRECTION
90˚
60°≤ β
Concrete class fb Angle [°] f,V ≤1
80° ≤9
0° V
C25/30 1,02 0 to 55 1
β


90°

≤β

C30/40 1,08 60 1,1


β
≤60°

C40/60 1,10 70 1,2 180˚ 0˚

C50/60 1,12 80 1,5


90 to 180 2 c
90
EPCON C8
10/12 Zinc coated & stainless steel studs - EMBEDMENT 16Ø

SPIT CC Method (values issued from ETA)


s INFLUENCE OF SPACING FOR CONCRETE CONE RESISTANCE IN TENSILE LOAD

N SPACING S Reduction factor s SPACING S Reduction factor s


Cracked & non-cracked concrete Cracked & non-cracked concrete
Anchor size M8 M10 M12 M16 Anchor size M20 M24 M30
40 0,55 100 0,55
50 0,57 0,55 120 0,56 0,55
60 0,58 0,56 0,55 0,54 150 0,58 0,57 0,55
s 80 0,60 0,58 0,57 0,55 250 0,63 0,61 0,59
120 0,66 0,63 0,60 0,58 350 0,68 0,65 0,62
s
s = 0,5 + 200 0,76 0,71 0,67 0,63 550 0,79 0,74 0,69
6.hef 250 0,83 0,76 0,72 0,66 650 0,84 0,78 0,73
smin < s < scr,N 385 1,00 0,90 0,83 0,75 750 0,89 0,83 0,76
480 1,00 0,92 0,81 850 0,94 0,87 0,80
scr,N = 3.hef
580 1,00 0,88 960 1,00 0,92 0,83
S must be used for each spacing
influenced the anchors group. 770 1,00 1150 1,00 0,90
1440 1,00

c,N INFLUENCE OF EDGE FOR CONCRETE CONE RESISTANCE IN TENSILE LOAD

N EDGE C Reduction factor c,N EDGE C Reduction factor c,N


Cracked & non-cracked concrete Cracked & non-cracked concrete
Anchor size M8 M10 M12 M16 Anchor size M20 M24 M30
40 0,41 100 0,41
50 0,45 0,41 120 0,44 0,41
c 60 0,48 0,44 0,41 150 0,48 0,45 0,41
80 0,56 0,50 0,46 0,41 250 0,64 0,58 0,51
c 190 0,99 0,84 0,74 0,62 300 0,72 0,64 0,56
c,N = 0,25 + 0,5 . 240 1,00 0,88 0,72 480 1,00 0,88 0,75
hef 290 1,00 0,82 580 1,00 0,85
cmin < c < ccr,N
ccr,N = 1,5.hef 385 1,00 720 1,00
c,N must be used for each distance
influenced the anchors group.

s-c,V INFLUENCE OF SPACING AND EDGE DISTANCE FOR CONCRETE EDGE RESISTANCE IN SHEAR LOAD

¬ For single anchor fastening


Reduction factor s-c,V
Cracked & non-cracked concrete
C
1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2
V Cmin

h>1,5.c
s-c,V 1,00 1,31 1,66 2,02 2,41 2,83 3,26 3,72 4,19 4,69 5,20 5,72


c c ¬ For 2 anchors fastening
s-c,V = .
cmin cmin Reduction factor s-c,V
Cracked & non-cracked concrete
s C
S Cmin 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2
Cmin
1,0 0,67 0,84 1,03 1,22 1,43 1,65 1,88 2,12 2,36 2,62 2,89 3,16
1,5 0,75 0,93 1,12 1,33 1,54 1,77 2,00 2,25 2,50 2,76 3,03 3,31
V 2,0 0,83 1,02 1,22 1,43 1,65 1,89 2,12 2,38 2,63 2,90 3,18 3,46
2,5 0,92 1,11 1,32 1,54 1,77 2,00 2,25 2,50 2,77 3,04 3,32 3,61
h>1,5.c
3,0 1,00 1,20 1,42 1,64 1,88 2,12 2,37 2,63 2,90 3,18 3,46 3,76
3,5 1,30 1,52 1,75 1,99 2,24 2,50 2,76 3,04 3,32 3,61 3,91


3.c + s c 4,0 1,62 1,86 2,10 2,36 2,62 2,89 3,17 3,46 3,75 4,05
s-c,V = .
6.cmin cmin 4,5 1,96 2,21 2,47 2,74 3,02 3,31 3,60 3,90 4,20
5,0 2,33 2,59 2,87 3,15 3,44 3,74 4,04 4,35
s1
s2 5,5 2,71 2,99 3,28 3,71 4,02 4,33 4,65
s3
6,0 2,83 3,11 3,41 3,71 4,02 4,33 4,65
sn-1

¬ For 3 anchors fastening and more


3.c + s1 + s2 + s3 +....+ sn-1 c
V
s-c,V = .
3.n.cmin cmin
h>1,5.c
91
EPCON C8
EMBEDMENT 20Ø - Zinc coated & stainless steel studs 11/12

SPIT CC Method (values issued from ETA)


TENSILE in kN SHEAR in kN
N ¬ Pull-out resistance ¬ Concrete edge resistance
for dry and wet concrete (1) V

NRd,p = N0Rd,p . fb VRd,c = V0Rd,c . fb . fV . S-C,V

V0Rd,c Design concrete edge resistance


N0Rd,p Design pull-out resistance at minimum edge distance (Cmin)
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
hef 160 200 240 320 400 480 600 hef 160 200 240 320 400 480 600
Non-cracked concrete 35,7 55,9 80,4 134,0 195,5 261,4 408,4 Cmin 40 50 60 80 100 120 150
Cracked concrete 21,2 33,2 45,2 76,0 118,7 170,9 219,9 Smin 40 50 60 80 100 120 150
Mc = 1,8 Non-cracked concrete 2,9 3,9 5,7 8,3 14,3 21,1 36,3
Cracked concrete 2,0 2,7 4 5,9 10,2 15 25,9
Mc = 1,5
N
¬ Concrete cone resistance V
for dry and wet concrete (1) ¬ Pryout failure
NRd,c = N0Rd,c . fb . s . c,N VRd,cp = V0Rd,cp . fb . s . c,N
N0Rd,c Design cone resistance V0Rd,cp Design pryout resistance
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
hef 160 200 240 320 400 480 600 hef 160 200 240 320 400 480 600
Non-cracked concrete 56,7 79,2 104,1 160,3 224,0 294,5 411,5 Non-cracked concrete 71,5 111,7 160,8 268,1 391,0 522,8 816,8
Cracked concrete 40,5 56,6 74,4 114,5 160,0 210,3 293,9 Cracked concrete 42,4 66,3 90,5 151,9 237,4 341,8 439,8
Mc = 1,8 Mcp = 1,5

¬ Steel resistance V ¬ Steel resistance

NRd,s Steel design tensile resistance VRd,s Steel design shear resistance
Anchor size M8 M10 M12 M16 M20 M24 M30 Anchor size M8 M10 M12 M16 M20 M24 M30
Std. stud grade 5.8* 12,0 19,3 28,0 52,0 81,3 118,0 186,7 Std. stud grade 5.8* 7,4 11,6 16,9 31,2 48,8 70,4 112,0
Std. stud grade 8.8* 19,3 30,7 44,7 84,0 130,7 188,0 299,3 Std. stud grade 8.8* 11,7 18,6 27,0 50,4 78,4 112,8 179,2
Std. stud grade 10.9* 26,4 41,4 60,0 112,1 175,0 252,1 400,7 Std. stud grade 10.9* 12,2 19,3 28,1 52,0 81,3 117,3 186,7
Std. stud grade 5.8 and 8.8 : Ms = 1,5 Std. stud grade 5.8 and 8.8 : Ms = 1,25
Std. stud grade 10.9 : Ms = 1,4 Std. stud grade 10.9 : Ms = 1,5
* Special grade available on request. * Special grade available on request.

(1) The concrete in the area of the anchorage is water statured. The anchor may be installed
in flooded holes, but the figures above cannot be used, you must use the values given in the
ETA for the category 2.

NRd = min(NRd,p ; NRd,c ; NRd,s) VRd = min(VRd,c ; VRd,cp ; VRd,s)


N = NSd / NRd  1 V = VSd / VRd  1

N + V  1,2
fb INFLUENCE OF CONCRETE f,V INFLUENCE OF SHEAR LOADING DIRECTION
90˚
60°≤ β
Concrete class fb Angle [°] f,V ≤1
80° ≤9
0° V
C25/30 1,02 0 to 55 1
β


90°

≤β

C30/40 1,08 60 1,1


β
≤60°

C40/60 1,10 70 1,2 180˚ 0˚

C50/60 1,12 80 1,5


90 to 180 2 c
92
EPCON C8
12/12 Zinc coated & stainless steel studs - EMBEDMENT 20Ø

SPIT CC Method (values issued from ETA)


s INFLUENCE OF SPACING FOR CONCRETE CONE RESISTANCE IN TENSILE LOAD

N SPACING S Reduction factor s SPACING S Reduction factor s


Cracked & non-cracked concrete Cracked & non-cracked concrete
Anchor size M8 M10 M12 M16 Anchor size M20 M24 M30
40 0,54 100 0,54
50 0,55 0,54 120 0,55 0,54
60 0,56 0,55 0,54 0,53 150 0,56 0,55 0,54
s 80 0,58 0,57 0,56 0,54 250 0,60 0,59 0,57
150 0,66 0,63 0,60 0,58 350 0,65 0,62 0,60
s
s = 0,5 + 250 0,76 0,71 0,67 0,63 450 0,69 0,66 0,63
6.hef 350 0,86 0,79 0,74 0,68 600 0,75 0,71 0,67
smin < s < scr,N 480 1,00 0,90 0,83 0,75 800 0,83 0,78 0,72
600 1,00 0,92 0,81 1000 0,92 0,85 0,78
scr,N = 3.hef
720 1,00 0,88 1200 1,00 0,92 0,83
S must be used for each spacing
influenced the anchors group. 960 1,00 1450 1,00 0,90
1800 1,00

c,N INFLUENCE OF EDGE FOR CONCRETE CONE RESISTANCE IN TENSILE LOAD

N EDGE C Reduction factor c,N EDGE C Reduction factor c,N


Cracked & non-cracked concrete Cracked & non-cracked concrete
Anchor size M8 M10 M12 M16 Anchor size M20 M24 M30
40 0,38 100 0,38
50 0,41 0,38 120 0,40 0,38
c 60 0,44 0,40 0,38 150 0,44 0,41 0,38
80 0,50 0,45 0,42 0,38 250 0,56 0,51 0,46
c 240 1,00 0,85 0,75 0,63 400 0,75 0,67 0,58
c,N = 0,25 + 0,5 . 300 1,00 0,88 0,72 600 1,00 0,88 0,75
hef 360 1,00 0,81 720 1,00 0,85
cmin < c < ccr,N
ccr,N = 1,5.hef 480 1,00 900 1,00
c,N must be used for each distance
influenced the anchors group.

s-c,V INFLUENCE OF SPACING AND EDGE DISTANCE FOR CONCRETE EDGE RESISTANCE IN SHEAR LOAD

¬ For single anchor fastening


Reduction factor s-c,V
Cracked & non-cracked concrete
C
1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2
V Cmin

h>1,5.c
s-c,V 1,00 1,31 1,66 2,02 2,41 2,83 3,26 3,72 4,19 4,69 5,20 5,72


c c ¬ For 2 anchors fastening
s-c,V = .
cmin cmin Reduction factor s-c,V
Cracked & non-cracked concrete
s C
S Cmin 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2
Cmin
1,0 0,67 0,84 1,03 1,22 1,43 1,65 1,88 2,12 2,36 2,62 2,89 3,16
1,5 0,75 0,93 1,12 1,33 1,54 1,77 2,00 2,25 2,50 2,76 3,03 3,31
V 2,0 0,83 1,02 1,22 1,43 1,65 1,89 2,12 2,38 2,63 2,90 3,18 3,46
2,5 0,92 1,11 1,32 1,54 1,77 2,00 2,25 2,50 2,77 3,04 3,32 3,61
h>1,5.c
3,0 1,00 1,20 1,42 1,64 1,88 2,12 2,37 2,63 2,90 3,18 3,46 3,76
3,5 1,30 1,52 1,75 1,99 2,24 2,50 2,76 3,04 3,32 3,61 3,91


3.c + s c 4,0 1,62 1,86 2,10 2,36 2,62 2,89 3,17 3,46 3,75 4,05
s-c,V = .
6.cmin cmin 4,5 1,96 2,21 2,47 2,74 3,02 3,31 3,60 3,90 4,20
5,0 2,33 2,59 2,87 3,15 3,44 3,74 4,04 4,35
s1
s2 5,5 2,71 2,99 3,28 3,71 4,02 4,33 4,65
s3
6,0 2,83 3,11 3,41 3,71 4,02 4,33 4,65
sn-1

¬ For 3 anchors fastening and more


3.c + s1 + s2 + s3 +....+ sn-1 c
V
s-c,V = .
3.n.cmin cmin
h>1,5.c
93