PRESSURE FILTER, change over Sheet No.

2514 T

Series HDD 170-450


4568 PSI

Dimensions:
type connection A B weight volume tank
HDD 170 14.96 13.78 84 lbs. 2x .18 Gal.
HDD 240 SAE 1 ½“ 16.93 15.75 88 lbs. 2x .23 Gal.
HDD 360 20.08 19.90 99 lbs. 2x .32 Gal.
HDD 450 24.21 23.06 110 lbs. 2x .42 Gal.

1) Connection for the potential equalization,


only for application in the explosive area.

Measure connections III and IV to be used for


pressure relief and air bleeding respective
filter side.

Position I: left filter side in operation


Position II: right filter side in operation

Dimensions: inches

Designs and performance values are subject to change.

EDV 07/19
Pressure Filter, changeover 1. Type index:
Series HDD 170-450 1.1. Complete filter: (ordering example)
4568 PSI HDD. 170.10VG. HR. E. P. -. FS. 7. -. -. AE
1 2 3 4 5 6 7 8 9 10 11 12

1 series:
HDD = pressure filter, change over
2 nominal size: 170, 240, 360, 450

3 filter-material and filter-fineness:


Description: 25VG, 16VG, 10VG, 6VG, 3VG microglass

Duplex pressure filter series HDD 170-450 with 4 filter element collapse rating:
change-over valve have a working pressure up to 30 = p 435 PSI
4568 PSI. Pressure peaks can be absorbed with a HR = p 2320 PSI (rupture strength p 3625 PSI)
sufficient safety margin.
5 filter element design:
Duplex filters can be serviced without interruption of E = single-end open
operation. The upper part has a three-way-change-
over valve which allows to change-over the flow from 6 sealing material:
the dirty filter-side to the clean filter-side without P = Nitrile (NBR)
interrupting the operation. The change-over procedure V = Viton (FPM)
does not lead to a cross sectional contraction. Prior to
the change-over procedure a built-in pressure balance 7 filter element specification:
valve equalizes the housing pressure. After change- - = standard
over the pressure balance valve is to be closed again. VA = stainless steel
The closed filter-side has to be air-bled by vent III
8 process connection:
respectively by vent IV. Then change filter element.
After screw in the filter bowl the pressure balance has FS = SAE-flange 6000 PSI
to be opened shortly and the just serviced filter-side 9 process connection size:
has to be air-bled. Filter elements are available down
7 = 1 ½“
to a filter fineness of 5 µm(C ).
10 filter housing specification:
Eaton filter elements are known for high intrinsic
stability and an excellent filtration capability, a high - = standard
dirt-retaining capacity and a long service life. 11 internal valve:
Eaton filter elements are available up to a pressure - = without
resistance of p 2320 PSI and a rupture strength of p S1 = with by-pass valve p 51 PSI
3625 PSI. S2 = with by-pass valve p 102 PSI
R = reversing valve, Q ≤ 55.75 GPM
Eaton filter can be used for petroleum-based fluids,
HW emulsions, water glycols, most synthetic fluids and 12 clogging indicator or clogging sensor:
lubrication fluids. Consult factory for specific fluid - = without
applications. AOR = visual, see sheet-no. 1606
AOC = visual, see sheet-no. 1606
The internal valve is integrated into the filter head. AE = visual-electric, see sheet-no. 1615
After reaching the bypass pressure setting, the bypass VS5 = electronic, see sheet-no. 1619
valve will send unfiltered partial flow around the filter.
To add an indicator/sensor to your filter, use the corresponding
The reversing valve provides another level of indicator data sheet to find the indicator details and add them to the
protection for the filter element. The reverse flow will filter assembly model code.
not be filtered.

1.2. Filter element: (ordering example)


01E. 170. 10VG. HR. E. P. -
1 2 3 4 5 6 7

1 series:
01E. = filter element according to company standard
2 nominal size: 170, 240, 360, 450

3 - 7 see type index-complete filter

Accessories:
- gauge port- and bleeder connection, see sheet-no. 1650

.
Technical data:
operating temperature: 14 °F to +212 °F
operating medium mineral oil, other media on request
max. operating pressure: 4538 PSI
test pressure: 6525 PSI
process connection: SAE-flange 6000 PSI
housing material: EN-GJS-400-18-LT, C-steel
sealing material: Nitrile (NBR) or Viton (FPM), other materials on request
installation position: vertical
measuring connections: BSPP ¼
bleeder connections: BSPP ½

Classified under the Pressure Equipment Directive 2014/68/EU for mineral oil (fluid group 2), Article 4, Para. 3.
Classified under ATEX Directive 2014/34/EU according to specific application (see questionnaire sheet-no. 34279-4).

Pressure drop flow curves:

Filter calculation/sizing
The pressure drop of the assembly at a given flow rate Q is the sum of the housing ∆p and the element ∆p and is calculated as follows:

p assembly = p housing + p element


p housing = (see p = f (Q) - characteristics)

p element (PSI) =  . ³

For ease of calculation our Filter Selection tool is available online at www.eatonpowersource.com/calculators/filtration/

Material gradient coefficients (MSK) for filter elements


The material gradient coefficients in psi/gpm apply to mineral oil (HLP) with a density of 0.876 kg/dm³ and a kinematic viscosity of
139 SUS (30 mm²/s). The pressure drop changes proportionally to the change in kinematic viscosity and density.

HDD VG
3VG 6VG 10VG 16VG 25VG
170 2.714 1.884 1.206 1.036 0.708
240 2.092 1.452 0.930 0.799 0.546
360 1.530 1.062 0.680 0.584 0.399
450 1.126 0.782 0.500 0.430 0.294

∆p = f(Q) – characteristics according to ISO 3968


The pressure drop characteristics apply to mineral oil (HLP) with a density of 0.876 kg/dm³. The pressure drop changes proportionally
to the density.
Symbols:
without indicator with electric with visual-electric with visual-electric with visual with electronic
indicator indicator indicator indicator sensor
AE 30 and AE 40 AE 50 and AE 62 AE 70 and AE 80 AOR/AOC VS5

filter without
internal valve

filter with
by-pass valve

filter with
reversing valve

Spare parts:
item qty. designation dimension article-no.
HDD 170 HDD 240 HDD 360 HDD 450
1 2 filter element 01E.170… 01E.240… 01E.360… 01E.450…
2 2 O-ring 34 x 3,5 304338 (NBR) 304730 (FPM)
3 2 O-ring 75 x 3 302215 (NBR) 304729 (FPM)
4 2 support ring 81 x 2,6 x 1 304581
5 2 O-ring 18 x 3 304359 (NBR) 304399 (FPM)
6 2 support ring 25 x 2,5 x 0,5 311311
7 2 O-ring 56 x 3 305072 (NBR) 305322 (FPM)
8 2 screw plug ½ BSPP 304678
9 2 screw plug ¼ BSPP 305003
10 1 clogging indicator visual AOR or AOC see sheet-no. 1606
11 1 clogging indicator visual-electric AE see sheet-no. 1615
12 1 clogging sensor electronic VS5 see sheet-no. 1619
13 1 screw plug 20913-4 309817
14 1 pressure balance valve 3/8“ 305000
item 13 execution only without clogging indicator or clogging sensor

Test methods: Filter elements are tested according to the following ISO standards:

ISO 2941 Verification of collapse/burst resistance


ISO 2942 Verification of fabrication integrity
ISO 2943 Verification of material compatibility with fluids
ISO 3723 Method for end load test
ISO 3724 Verification of flow fatigue characteristics
ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-pass method for evaluating filtration performance

North America China For more information, please


44 Apple Street No. 3, Lane 280,
Tinton Falls, NJ 07724 Linhong Road email us at [email protected]
Toll Free: 800 656-3344 Changning District, 200335 or visit www.eaton.com/filtration
(North America only) Shanghai, P.R. China
Tel: +1 732 212-4700 Tel: +86 21 5200-0099
© 2019 Eaton. All rights reserved. All trademarks and
registered trademarks are the property of their respective
owners. All information and recommendations appearing in
Europe/Africa/Middle East Singapore this brochure concerning the use of products described herein
Auf der Heide 2 100G Pasir Panjang Road #07-08 are based on tests believed to be reliable. However, it is the
53947 Nettersheim, Germany Singapore 118523 user’s responsibility to determine the suitability for his own
Tel: +49 2486 809-0 Tel: +65 6825-1668 use of such products. Since the actual use by others is
beyond our control, no guarantee, expressed or implied, is
Friedensstraße 41 made by Eaton as to the effects of such use or the results to
68804 Altlußheim, Germany be obtained. Eaton assumes no liability arising out of the use
Tel: +49 6205 2094-0 Brazil by others of such products. Nor is the information herein to be
Av. Ermano Marchetti, 1435 - construed as absolutely complete, since additional information
An den Nahewiesen 24 Água Branca, São Paulo - SP, may be necessary or desirable when particular or exceptional
55450 Langenlonsheim, Germany 05038-001, Brazil conditions or circumstances exist or because of applicable
Tel: +49 6704 204-0 laws or government regulations.
Tel: +55 11 3616-8461

You might also like