0% found this document useful (0 votes)
166 views

Solar Inverter Catalog

Uploaded by

Hassen Jbira
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views

Solar Inverter Catalog

Uploaded by

Hassen Jbira
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 66

Wherever there is clean energy,

there are MUST products and services

—— MUST ENERGY (GUANGDONG) TECHNOLOGY CO., LTD ——


Sales Office Address: 18F, Taibang Technology Building,No.4 Road High-Tech South,
Nanshan District,Shenzhen City,China

Web: www.mustenergy.com | www.mustpower.com

Tel: +86 755 83658583 (Asia) | +86 755 83657661 (Africa)


+86 755 83657660 (Europe) | +86 757 82629306 (Americas) PRODUCT CATALOGUE
Inverter/ Solar Charge Controller
Factory Address: Block 8, Huanan Power Innovation and Technology Park, No.115 Zhangcha Road 1,
Chancheng District, Foshan City, Guangdong Province, China.

The technical specifications of this document are subject to change without any notice

120V/230V
Why Choose MUST? Complete Power Solution
Committed to providing one-stop power solution, including power generation, power conversion, storage, monitoring & management
MUST Renewable and accessories.

We are proud to have been manufacturing portable power stations, LiFePO4 batteries, inverters, UPS, and solar charge controllers
since 1998, with a team of 500 dedicated employees.
MUST integrates the latest and most advanced technology and automation solutions, owning the most complete product line in the HYBRID ON GRID
LITHIUM BATTERY POWER INVERTER
industry with reliable quality, high efficiency and stable performance. SOLAR INVERTER INVERTER

Years Industry Experience Patents, copyright

20+ 120+
Plants Employees

35,000m 2
500+
R&D Staffs Overseas Service Center

100+ 6

ALL-IN-ONE
SYSTEM

OFF GRID
SOLAR INVERTER

BALCONY SOLAR CHARGER


Efficient Production, Operation, Quality Control ENERGY STORAGE CONTROL

Intelligent Comprehensive
Lean production
Manufacturing Professional Test

Automatic integrated production line, automatic SMT production line and automatic and digital quality control andmanagement of
manufacturing key sections: online AOI inspection, FCT, ATE, Aging test. R&D tests includes lslanding detection etc.

2
Products / 230V

230V Series
Off Grid Solar Inverter/ On/Off Grid Hybrid Solar Inverter/ Grid-Tie Solar Inverter/ Off Grid Power Inverter

4
Products / 230V

SIMULATED SINE WAVE SOLAR INVERTER MODEL PV11-1200 Plus PV11-2400 Plus

PV1100 PLUS Series Nominal Battery System Voltage 12VDC 24VDC

NVERTER OUTPUT

Rated Power 1200VA/720W 2400VA/1440W


1.2~2.4KVA | PWM 50A | AC 10A/20A
Waveform Simulated Sine-wave
PV1100Plus is a cost effective , intelligent hybrid off grid solar inverter. The LCD Nominal Output Voltage RMS 230V
display offers friendly user-configurable button adjustment such as battery
charging current, AC/solar charger priority and DC priority. When battery Output Voltage Regulation +10/-18%
voltage is low, it will automatically switch to AC grid to supply continuous Output Frequency 50Hz/60Hz +/-1 Hz
power to the loads. It suitable for personal home use.
Inverter Efficiency(Peak) >80%

Line Mode Efficiency >98%


■ Simulated sine wave inverter

■ Built-in 50A PWM Solar Charge Controller Typical Transfer Time Typical 15~20ms 40ms max

■ MFD (multi-function display) AC INPUT

■ 10A or 20A standard charging current from utility Voltage 230VAC

■ AC/solar priority for output via MFD Selectable Voltage Narrow 170~280VAC
Range Wide 90~280VAC
■ AC/solar priority for charging via MFD

■ 3 steps charging algorithm Frequency Range 40Hz-70Hz (Auto sensing)


■ Overload & short-circuit protection BATTERY
■ Battery reverse polarity protection Nominal Input Voltage 12VDC 24VDC
■ Deep discharge protection Minimum Start Voltage 10.5VDC 21.0VDC
■ Auto restart while AC/solar is recovering Low Battery Alarm 10.5VDC (min) 21VDC (min)
■ Adjustable solar and utility charging current Low Battery Cutoff 10~12VDC (Can be set) 20~24VDC (Can be set)

High Voltage Cutoff 15.0VDC (max) 30.0VDC (max)


Back panel description SOLAR CHARGER & AC CHARGER

Maximum PV Charge Current 50A (max)

Maximum PV Array Power 750W 1500W

PWM Range @ Operating Voltage 16~55VDC


1. Output Receptacle (s)
Maximum PV Array Open Circuit Voltage 55VDC
2. LCD display
Maximum Efficiency >95%
3. Status indicators
1
4. Setting button Standby Power Consumption <2W
5. Power switch AC Charger Voltage 14.4V(max) 28.8V(max)
6. External battery connectors
AC Charging Current 10A / 20A (Can be set)
7. FAN
8. Solar panel terminal Maximum Charge Current 10-50A (Can be set)
9. Input circuit breaker (plastic case) BYPASS & PROTECTION
10. AC input
Nominal Input Frequency 40Hz - 70Hz

Overload Protection (SMPS Load) FUSE


2 3 4 5 6 7 8 9 10

Output Short Circuit Protection FUSE


Solar system connection
Bypass Fuse Rating 10A

Max Bypass Current 10Amp

MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 295*230*85mm


TV Fridge Lighting Fans
PV input
Package Dimension (W*H*D) 365*295*140mm

Solar Panel N.W (kg) 2.7kg

G.W (kg) 13.5kg/4pcs


AC Input
OTHER
BAT input
Utility Operation Temperature Range 0°C to 50°C

Audible Noise 50dB MAX


Inverter Battery
Display LED+LCD

6
Products / 230V

HIGH FREQUENCY OFF GRID SOLAR INVERTER MODEL PV15-1012 PV15-1512 PV15-2024

PV1500 Series Nominal Battery System Voltage 12VDC 12VDC 24VDC


NVERTER OUTPUT
Rated Power 1000VA / 600W 1500VA/ 1000W 2000VA / 1500W
1~2KVA | MPPT 45A | AC 15A/20A
Waveform Pure Sine Wave

It is a cost effective, intelligent solar inverter which accepts Solar & Utility input Nominal Output Voltage RMS 230V
at the same time. The comprehensive LCD display offers user- configurable and Output Voltage Regulation +10/-18%
easy-accessible button adjustment such as battery charging current, AC/solar
charger priority and DC priority.When battery voltage is low,it will automatically Output Frequency 50Hz / 60Hz ± 1Hz
switch to AC grid to supply continuous power to the loads. Inverter Efficiency (Peak) >90%
Line Mode Efficiency >95%
■ Built-in 45A MPPT Solar Charge Controller
■ 15A@24V, 20A@12V standard charging current from utility AC Typical Transfer Time Typical < 10ms , 20ms max
■ AC/solar priority for charging via MFD AC INPUT
■ Different charging mode for different kinds of batteries Voltage 230VAC
■ Overload & short-circuit protection, Battery reverse polarity protection,
Deep discharge protection Voltage Range 170~280VAC (UPS) / 90~280VAC (APL) / 184~258VAC (VDE)

■ Auto restart while AC/solar is recovering Adjustable solar and utility Frequency Range 50Hz/ 60Hz (auto sensing)
charging current
BATTERY
■ Support two kinds of batteries include LiFePO4 Lithium Battery Pack
and Lead-acid Battery. Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack - 12V(4 Series) 24V(8 Series)
■ Support one key battery type fast setting Nominal Input Voltage 12VDC 12VDC 24VDC
■ Automatic activate protected lithium battery pack by Utility AC.
Low Battery Cutoff 10.5VDC(PB) 11.5VDC(LI) 10.5VDC(PB) 11.5VDC(LI) 21.0VDC(PB) 23.0VDC(LI)
■ Automatic activate protected lithium battery pack by Solar PV
Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)
■ Low shutdown loss for energy storage system application
Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)
High Battery Voltage Recover 14.5VDC(PB) 14.5VDC(LI) 14.5VDC(PB) 14.5VDC(LI) 29.0VDC(PB) 29.0VDC(LI)
Back panel description
High Battery Voltage Cutoff 15.0VDC(PB) 15.0VDC(LI) 15.0VDC(PB) 15.0VDC(LI) 30.0VDC(PB) 30.0VDC(LI)

1KW/ 2KW SOLAR CHARGER & AC CHARGER


Charger Voltage boost 14.4VDC(PB) 14.4VDC(LI) 14.4VDC(PB) 14.4VDC(LI) 28.8VDC(PB) 28.8VDC(LI)
Charger Voltage float 13.8VDC(PB) 14.4VDC(LI) 13.8VDC(PB) 14.4VDC(LI) 27.6VDC(PB) 28.8VDC(LI)

1. Output Receptacle (s) Maximum PV Charge Current 45A (max)


2. LCD display Maximum PV Array Power 600W 600W 1200W
3. Status indicators
1
MPPT Operating Voltage Range 14 ~ 75VDC 14 ~ 75VDC 28 ~ 75VDC
4. Setting button
Maximum PV Array Open Voltage 105V
AC Output Socket types

5. Power switch
6. External battery connectors Maximum Efficiency > 95%
7. FAN AC Charging Current 10A/20A (Can be set) 10A/20A (Can be set) 7A/15A (Can be set)
8. Solar panel terminal
Maximum Charge Current AC+PV 10~65A (Can be set) 10~65A (Can be set) 10~60A (Can be set)
9. Input circuit breaker (plastic case)
BYPASS & PROTECTION
10. AC input
2 3 4 5 6 7 8 9 10 Overload Protection (SMPS Load) FUSE
Output Short Circuit Protection FUSE
Bypass Fuse Rating 7A 10A 10A
Max Bypass Current 7A 10A 10A
Material selection Solar system connection
MECHANICAL SPECIFICATIONS
Machine Dimension (W*H*D) 235*290*92mm 224*337*98mm 235*290*92mm
Metal case Plastic case Package Dimension (W*H*D) 595*375*315mm 300*410*178mm 595*375*315mm
N.W (kg) 2.8kg 3.6kg 3.0kg
PV input
G.W (kg) 3.5kg 4.3kg 3.7kg

Solar Panel Load Material Plastic case Metal case Plastic case
OTHER
Operation Temperature Range 0℃ to 40℃
AC Input BAT input
Audible Noise 50dB MAX

Utility Battery
Display LED+LCD
Inverter
CERTIFICATION & STANDARDS
PV15-1512 PV15-1012/ PV15-2024 CE

8
Products / 230V

HIGH FREQUENCY SOLAR INVERTER PV18-1612 PV18-2524 PV18-3024 PV18-3524 PV18-5548 PV18-6248
MODEL
PV1800 ECO Series ECO ECO ECO ECO ECO ECO

Default Battery System Voltage 12VDC 24VDC 24VDC 24VDC 48VDC 48VDC

INVERTER OUTPUT
1.6~6.2KW | Dual output
Rated Power 2000VA/1600W 2500VA/2500W 3000VA/3000W 3500VA/3500W 5500VA/5500W 6200VA/6200W
PV1800 ECO is a multi-function inverter/charger, combining functions of
inverter, MPPT solar charger and battery charger to offer uninterruptible power Output Channel Dual Dual Dual Dual Dual Dual
support in portable size. PV1800 ECO Series can run without battery.
The Maximum PV input voltage can reach 400V/450V/500V, which can help Surge Power 3200W 5000W 6000W 7000W 11000W 12400W
customers make full use of solar energy.(For 1.6~6.2KW)
Waveform Pure sine wave

AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)


■ Pure sine wave output
Inverter Efficiency(Peak) >90%
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
■ Built-in MPPT solar charge controller Transfer Time Typical < 10ms , 20ms max
■ Wide PV input voltage range
■ Can provide the power to the load without battery AC INPUT
■ Combining solar system, AC utility, and battery power source to
Voltage 230VAC
supply continuous power
■ Overload, short circuit and Deep discharge protection Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
■ Cold start function
■ Support RS485,CAN monitoring function Frequency Range 50Hz / 60Hz (Auto sensing)
■ Dual outputs for smart load management
BATTERY
■ Can communicate with lithium batteries (CAN port)
Normal voltage 12V 24VDC 24VDC 24VDC 48VDC 48VDC

Floating Charge Voltage 13.7VDC 27.4VDC 27.4VDC 27.4VDC 54.8VDC 54.8VDC

Back panel description Overcharge Protection 15VDC 30VDC 30VDC 30VDC 60VDC 60VDC

SOLAR CHARGER & AC CHARGER


3.5KW

Maximum PV Input Voltage 400VDC 400VDC 400VDC 450VDC 450VDC 500VDC


1 2 3 4 5 6 7 8 9 10
Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)

Maximum PV Array Power 2000W 4000W 4000W 4000W 6000W 6200W

PV Array MPPT Voltage Range(Typ.) 30~320VDC 30~320VDC 30~320VDC 60~360VDC 60~360VDC 120~450VDC

PV maximum input current 16A 18A 18A 18A 28A 28A

Maximum Solar Charge Current 80A 100A 100A 100A 100A 120A
1. Ground 6. PV input
Maximum AC Charge Current 80A 60A 60A 60A 100A 100A
2. AC Input 7. ON/OFF Switch
3. AC Output1 8. RS-485/CAN Communication port Maximum Charge Current 80A 100A 100A 100A 100A 120A
4. AC Output2 9. Dry Contact
MECHANICAL SPECIFICATIONS
5. Battery Input 10. WiFi port
367*290*111 367*290*111 367*290*111 367*318*122.5 454*318*122.5 428*318*140
Machine Dimension (W*H*D)
mm mm mm mm mm mm
446*394*187 446*394*187 446*394*187 446*410*200 544.5*410*210 550*400*220
Solar system connection Package Dimension (W*H*D)
mm mm mm mm mm mm

N.W 6.4kg 6.7kg 6.7kg 7.3kg 9.0kg 10.0kg


PV input
Fridge Lighting Fans G.W 7.4kg 7.7kg 7.7kg 8.3kg 10.5kg 11.6kg
Solar Panel
Main Load OTHER

AC Input
Humidity 5% to 95% Relativ Humidity (Non-condensing)

Utility Operating Temperature 0°C~50°C

BAT input
Second Load Storage Temperature -15°C -60°C

TV Air conditioner Washing machine CERTIFICATION & STANDARDS


Generator Battery Inverter
CE

10
Products / 230V

HIGH FREQUENCY SOLAR INVERTER MODEL PV18-2024 PRO PV18-3224 PRO

PV1800 PRO Series Nominal Battery System Voltage 24VDC

INVERTER OUTPUT
2~3.2KW | 400V | WiFi
Rated Power 2000VA / 2000W 3200VA / 3200W

PV1800 PRO is a multi-function inverter/charger, combining functions of Surge Power 4000W 6400W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV1800 PRO Series can run without battery. The Waveform Pure sine wave
Maximum PV array open circuit voltage can reach 400V and MPPT voltage is
60~320Vdc, which Can help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)

Inverter Efficiency(Peak) 90%

Transfer Time 10ms (UPS / VDE4105) / 20ms (APL)


■ Pure sine wave output
AC INPUT
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
■ Built-in MPPT solar charge controller Voltage 230VAC±5%
■ MAX PV Array Open Circuit Voltage: 400V
■ Combining solar system, AC utility, and battery power source to supply Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
continuous power
Frequency Range 50Hz / 60Hz(Auto sensing)
■ Overload, short circuit and Deep discharge protection
■ Cold start function BATTERY
■ Support USB, RS485 monitoring function
■ WIFI remote monitoring (Built in wifi module and antenna) Normal voltage 24VDC
■ PV/ AC activation function
Floating Charge Voltage 27.4VDC
■ BMS communication function
Overcharge Protection 30VDC

Back panel description SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage 400VDC


1 2 3 8
Maximum PV input voltage 18A
1. AC input
2. Ground
Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
3. AC output
4. Circuit breaker Maximum PV Array Power 3000W 4000W
5. External WIFI antenna (optional)
PV Array MPPT Voltage Range 60~320 VDC
4 5 6 7 6. Battery input
7. PV input
9 10 11 12
Maximum Solar Charge Current 80A 100A
8. Power on/off switch
9. Dry contact Maximum AC Charge Current 40A 60A
10. USB
Maximum Charge Current 80A 100A
11. RS-485, CAN communication port
12. WIFI (optional)
MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 367*290*111mm

Solar system connection Package Dimension (W*H*D) /

N.W (kg) /

G.W (kg) /
PV input
TV Fridge Lighting Fans
OTHER
Solar Panel

Humidity 5% to 95% Relative humidity (Non-condensing)


AC Input

Operating Temperature 0°C~50°C


Utility
Storage Temperature -15℃ ~60℃
BAT input

MECHANICAL SPECIFICATIONS

Inverter
Generator Battery CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

12
Products / 230V

HIGH FREQUENCY SOLAR INVERTER MODEL PV18-3024 PRO PV18-5248 PRO

PV1800 PRO Series Nominal Battery System Voltage 24VDC 48VDC

INVERTER OUTPUT

3~5.2KW | 450V | WiFi | 9pcs parallel Rated Power 3000VA / 3000W 5200VA / 5200W

PV1800 PRO is a multi-function inverter/charger, combining functions of Surge Power 6000W 10400W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV1800 PRO Series can run without battery. Waveform Pure sine wave
The Maximum PV array open circuit voltage can reach 450V and MPPT voltage
is 150~430Vdc, which Can help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)

Inverter Efficiency(Peak) 90%

Transfer Time 10ms (UPS / VDE4105) / 20ms (APL)

■ Pure sine wave output AC INPUT

■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
Voltage 230VAC±5%
■ Built-in MPPT solar charge controller
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
■ MAX PV Array Open Circuit Voltage: 450V

■ Combining solar system, AC utility, and battery power source to supply Frequency Range 50Hz / 60Hz(Auto sensing)
continuous power
BATTERY
■ Overload, short circuit and Deep discharge protection

■ Cold start function Normal voltage 24VDC 48VDC

■ Support USB, RS485 monitoring function Floating Charge Voltage 27.4VDC 54.8VDC
■ Parallel operation with up to 9 units
Overcharge Protection 30VDC 60VDC
■ WIFI remote monitoring (optional)
SOLAR CHARGER & AC CHARGER

Back panel description Maximum PV Array Open Circuit Voltage 450VDC

3KW Maximum PV input voltage 18A 18A 27A

1 2 3 7 8 9 10 11 12 1. AC Input Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
2. AC Output
Maximum PV Array Power 4000W 5000W 6000W
3. PV Input
4. Power On/Off Switch PV Array MPPT Voltage Range 150~430 VDC
6 5 4 5. Battery Input
6. Circuit breaker Maximum Solar Charge Current 80A 100A 80A 100A

7. Dry Contact
5KW Maximum AC Charge Current 60A 80A 60A 80A
1 2 9 8 7 3 4 12 8. USB port
9. RS-485/CAN Communication port Maximum Charge Current 80A 100A 80A 100A
10. Parallel switch (only for parallel model)
MECHANICAL SPECIFICATIONS
11. Parallel communication port
(only for parallel model)
Machine Dimension (W*H*D) 322*486*134mm 309*505*147mm
12. USB WiFi port
6 10 11 5
Package Dimension (W*H*D) 575*229*425mm 603*260*400mm

Solar system connection )N.W (kg) 10.6kg 12.9kg

G.W (kg 12kg 13.8kg

OTHER
PV input
TV Fridge Lighting Fans
Humidity 5% to 95% Relative humidity (Non-condensing)
Solar Panel

Operating Temperature 0°C~50°C


AC Input
Storage Temperature -15℃ ~60℃

Utility
CERTIFICATION & STANDARDS
BAT input
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2020+A11:2020
EN IEC62368-1:2018
Inverter
Generator Battery Rohs-(2011/65/EUand2015/863/EU)

14
Products / 230V

HIGH FREQUENCY SOLAR INVERTER MODEL PV18-8048 PRO PV18-10048 PRO

PV1800 PRO Series Nominal Battery System Voltage 48VDC

INVERTER OUTPUT
8~10KW | 450V | WiFi
Rated Power 8000W 10000W

This is a multi-function inverter/charger, combining functions of inverter, Surge Power 16000W 20000W
solar charger and battery charger to offer uninterruptible power support with
portable size. Its comprehensive LCD display offers user-configurable and easy- Waveform Pure Sine Wave
accessible button operation such as battery charging current, AC/solar charger
priority, and acceptable input voltage based on different applications. AC Voltage Regulation (Batt.Mode) 230VAC±5%

Output Frequency 60Hz or 50Hz

Inverter Efficiency(Peak) 90%

■ Pure sine wave output Transfer Time 10ms (UPS) 20ms (APL)
■ Combining solar system, AC utility, and battery power source to supply
continuous power AC INPUT

■ Configurable battery charging current based on applications via LCD setting Nominal Input Voltage 230VAC
■ Configurable AC/Solar Charger priority via LCD setting
Max AC Input Voltage 300VAC
■ Compatible to mains voltage or generator power
Selectable Voltage Range 170~280VAC (UPS) / 90~280VAC (APL) / 184~253VAC(VDE4105)
■ Auto restart while AC is recovering

■ Overload/ Over temperature/ short circuit protection Frequency Range 50Hz / 60Hz(Auto detection)

■ CAN/RS485 communication for BMS BATTERY


■ Cold start function
Normal Voltage 48VDC
■ WiFi remote monitoring (optional)
SOLAR CHARGER & AC CHARGER
Back panel description AC Charging Current 2-120A 2-160A

Maximum PV Array Open Circuit Voltage 450VDC


1. Ground
1 2 1 3 4 5 6 7 8 9 10 11 12 13
2. AC Input PV Array Open Circuit Voltage 150-430VDC
3. AC Output
4. AC input breaker Cold Start Voltage 46VDC

5. PV input
Solar Charging Current 80A/80A 100A/100A
6. COM2
7. BMS communication Default Charging Current 80A/80A
8. Battery input
14 Maximum Charge Current 160A 200A
9. Power on/off switch
10. PV input Charging Algorithm 3-step (Flooded Battery / AGM / GEL/ LEAD Battery), 4-step(LI)
11. COM1
12. USB MECHANICAL SPECIFICATIONS
13. Dry contact
Machine Dimension (W*H*D) 600*503*141.2mm
14. WiFi port
Package Dimension (W*H*D) /

Solar system connection N.W (kg) 21kg

G.W (kg) /

PV1 input OTHER


Solar Panel
Safety Certification CE
TV Fridge Lighting Fans

PV2 input
Operating Temperature -10°C~50°C
Solar Panel

Storage Temperature -15°C ~60°C


AC Input BAT input

CERTIFICATION & STANDARDS


Utility
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2020+A11:2020
Inverter EN IEC62368-1:2018
Generator Battery Rohs-(2011/65/EUand2015/863/EU)

16
Products / 230V

HIGH FREQUENCY SOLAR INVERTER PV18-1012 PV18-2024 PV18-3024 PV18-4048 PV18-5048


MODEL

PV1800 VPK Series


VPK VPK VPK VPK VPK
Nominal Battery System Voltage 12VDC 24VDC 48VDC

INVERTER OUTPUT
1~5KW | PWM 50A/60A | WiFi
Rated Power 1000W 2000W 3000W 4000W 5000W
PV1800 VPK is a multi-function inverter/charger, combining functions of
inverter, PWM solar charger and battery charger to offer uninterruptible Surge Power 2000W 4000W 6000W 8000W 10000W
power support with portable size. Its comprehensive LCD display offers user-
configurable easy-accessible button operation such as battery charging current, Waveform Pure sine wave
AC/solar charger priority, and acceptable input voltage based on different
applications. AC Voltage Regulation (Batt.Mode) (220VAC~240VAC)±5%

Inverter Efficiency(Peak) 93%

Transfer Time 10ms (UPS / VDE4105) 20ms (APL)


■ Smart LCD setting(Working modes, Charge Current, Charge Voltage, etc.)
AC INPUT
■ Built-in PWM 50A/60A solar charge controller
■ New SUB working mode(Solar-Utility-Battery working mode) Voltage 230VAC
■ Combining solar system, AC utility, and battery power source to
supply continuous power Selectable Voltage Range 170~280VAC(For personal computer) / 90~280VAC(For home appliances) / 184~253VAC(VED4105)
■ Overload, short circuit and deep discharge protection
Frequency Range 50Hz / 60Hz(Auto sensing)
■ Parallel operation with up to 3 units (Available for 4KW/5KW only)
■ Cold start function BATTERY
■ Support USB, RS485 monitoring function
■ WIFI remote monitoring (optional) Normal voltage 12VDC 24VDC 48VDC

■ Compatible to generator
Floating Charge Voltage 13.7VDC 27.4VDC 54.8VDC

Back panel description Overcharge Protection 15.5VDC 30VDC 60VDC

1KW
SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage 55VDC 75VDC 80VDC 105VDC


1. AC Input
2. AC Output Standby Power Consumption 2W 2W 2W
3. Circuit breaker
(PWM)Maximum Solar Charge Current 50A 50A 60A 60A
1 2 3 4 5 7 8 9 4. Battery Input
5. PV Input
Maximum AC Charge Current 10A or 20A 10A or 20A 20A or 30A 60A
2~3KW 6. Power On/Off Switch
61 2 6 8 7 10 9 7. USB Maximum ChargeCurrent 70A 70A 80A 120A
8. RS-485 Communication port
9. USB WiFi port MECHANICAL SPECIFICATIONS
10. Dry Contact
Machine Dimension (W*H*D) 224*337*98mm 290*342*125mm 297.5*468*125mm

3 4 5 Package Dimension (W*H*D) / / /

Solar system connection N.W (kg) / / /

G.W (kg) / / /

OTHER
PV input
TV Fridge Lighting Fans
Humidity 5% to 95% Relative humidity (Non-condensing)
Solar Panel

Operating Temperature 0°C~50°C


AC Input

Storage Temperature -15℃ ~60℃


Utility

BAT input CERTIFICATION & STANDARDS

CE-EMC+LVD (EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011)


CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
Inverter
Generator Battery UKCA

18
Products / 230V

HIGH FREQUENCY SOLAR INVERTER MODEL


PV18-2024 PV18-3024 PV18-3048 PV18-4048 PV18-5048 PV18-5548

PV1800 VHM Series


VHM VHM VHM VHM VHM VHM
Nominal Battery System Voltage 24VDC 48VDC

INVERTER OUTPUT
2~5.5KW | MPPT 80A | PV 145V
Rated Power 2000W 3000W 3000W 4000W 5000W 5500W

PV1800 VHM is a multi-functional inverter/charger, combining functions of Surge Power 4000W 6000W 6000W 8000W 10000W 11000W
inverter, solar charger and battery charger to offer uninterruptible power
support in portable size. Its comprehensive LCD display offers user-configurable Waveform Pure Sine Wave
and easy-accessible button operation such as battery charging current,
AC/solar charger priority, and acceptable input voltage based on different AC Voltage Regulation (Batt.Mode) (220VAC~240VAC)±5%
applications.
Inverter Efficiency(Peak) 93%

Transfer Time 10ms (UPS / VDE4105) 20ms (APL)

AC INPUT
■ Rated power : 2KW -5.5KW
■ Pure sine wave solar inverter Voltage 230VAC
■ Output power factor 1
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE4105)
■ Built-in 80A MPPT solar charger
■ Built-in anti-dust kit for harsh environment Frequency Range 50Hz / 60Hz(Auto sensing)
■ Support parallel operation up to 3 units (available for 3KW-5.5KW 48V)
BATTERY
■ WIFI remote monitoring (optional)
■ Compatible to generator Normal Voltage 24VDC 48VDC

Floating Charge Voltage 27.4VDC 54.8VDC

Overcharge Protection 30VDC 60VDC

Back panel description SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage 145VDC


3KW

PV Array MPPT Voltage Range 30~130VDC 60~130VDC


6 7 8 9 11 10 12 13 14 15 1. AC input
2. AC output
Standby Power Consumption 2W
3. Circuit breaker
4. Battery input PV Input Power 2000W 4000W
5. PV input
Maximum Solar Charge Current 80A
6. Power on/off switch
7. RS-485 Communication port
Maximum Effciency 98%
5KW 8. USB
1 2 3 4 6 5 7 8 9 11 12 10 9. Dry contact Maximum AC Charge Current 20A/30A 60A
10. USB wifi port
Maximum Charge Current 80A 140A
11. Parallel switch (only for parallel model)
12. Parallel communication port (only for parallel model)
MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 300*414*116mm 329*485*134mm

Solar system connection Package Dimension (W*H*D) / /

N.W (kg) / /

PV input
G.W (kg) / /
TV Fridge Lighting Fans
OTHER
Solar Panel

Humidity 5% to 95% Relatiy Humidity (Non-condensing)


AC Input

Operating Temperature 0°C~50°C


Utility
Storage Temperature -15°C ~60°C
BAT input

CERTIFICATION & STANDARDS


Inverter
Generator Battery CE-LVD (IEC62109-1:2010, EN IEC62109-2); UKCA

20
Products / 230V

HIGH FREQUENCY SOLAR INVERTER MODEL PV18-3048 VHM PV18-4048 VHM PV18-5048 VHM PV18-5548 VHM

PV1800 VHM Series Nominal Battery System Voltage 48VDC

INVERTER OUTPUT
3~5.5KW | MPPT 80A | PV 250V
Rated Power 3000W 4000W 5000W 5500W

PV1800 VHM is a multi-functional inverter/charger, combining functions of Surge Power 6000W 8000W 10000W 11000W
inverter, solar charger and battery charger to offer uninterruptible power
support in portable size. Its comprehensive LCD display offers user-configurable Waveform Pure Sine Wave
and easy-accessible button operation such as battery charging current,
AC/solar charger priority, and acceptable input voltage based on different AC Voltage Regulation (Batt.Mode) (220VAC~240VAC)±5%
applications.
Inverter Efficiency(Peak) 93%

Transfer Time 10ms (UPS / VDE4105) 20ms (APL)

AC INPUT
■ Rated power : 3KW -5.5KW
■ Pure sine wave solar inverter Voltage 230VAC
■ Max PV Array Open Circuit Voltage: 250V
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE4105)
■ Output power factor 1
■ Built-in 80A MPPT solar charger Frequency Range 50Hz / 60Hz(Auto sensing)
■ Support parallel operation up to 3 units
BATTERY
■ Communication CAN/485 port for BMS (optional)
■ PV lithium battery activation function Normal Voltage 48VDC
■ WIFI remote monitoring (optional)
Floating Charge Voltage 54.8VDC
■ Compatible to generator
Overcharge Protection 60VDC

Back panel description SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage 250VDC

1 2 3 4 6 5
PV Array MPPT Voltage Range 60~200VDC
1. AC input
2. AC output Standby Power Consumption 2W
3. Circuit breaker
4. Battery input PV Input Power (STC) 4500W
5. PV input
Maximum Solar Charge Current 80A
6. Power on/off switch
7. RS-485 Communication port Maximum Effciency 98%
7 8 9 11 12 10 8. USB
9. Dry contact Maximum AC Charge Current 60A
10. USB wifi port
Maximum Charge Current 140A
11. Parallel switch (only for parallel model)
12. Parallel communication port (only for parallel model) MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 329*485*134mm

Solar system connection Package Dimension (W*H*D) /

N.W (kg) /

G.W (kg) /
PV input
TV Fridge Lighting Fans
OTHER
Solar Panel

Humidity 5% to 95% Relatiy Humidity (Non-condensing)


AC Input

Operating Temperature 0°C~50°C


Utility
Storage Temperature -15°C ~60°C
BAT input

CERTIFICATION & STANDARDS

Inverter CE-LVD (IEC62109-1:2010, EN IEC62109-2); UKCA


Generator Battery

22
Products / 230V

HIGH FREQUENCY SOLAR INVERTER MODEL


PV18-1612 PV18-2524 PV18-3024 PV18-3524 PV18-5548

PV1800 PREM Series


PREM PREM PREM PREM PREM
Nominal Battery System Voltage 12VDC 24VDC 24VDC 24VDC 48VDC

INVERTER OUTPUT
1.6-5.5KW | Dual output | WiFi
Rated Power (Main+Second Load) 2000VA/1600W 2500VA/2500W 3000VA/3000W 3500VA/3500W 5500VA/5500W

PV1800 PREM is a multi-function inverter/charger, combining functions of Surge Power 3200W 5000W 6000W 7000W 11000W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV1800 PREM Series can run without battery. Waveform Pure sine wave
The Maximum PV array open circuit voltage can reach 400V/450V. which Can
help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)

Inverter Efficiency(Peak) 90~93%

Transfer Time 10ms (UPS / VDE4105) / 20ms (APL)


■ Pure sine wave output
AC INPUT
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
■ Built-in MPPT solar charge controller Voltage 230VAC±5%
■ Combining solar system, AC utility, and battery power source to supply
continuous power Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)

■ Overload, short circuit and Deep discharge protection


Frequency Range 50Hz / 60Hz(Auto sensing)
■ Cold start function
■ Support USB, RS485, CAN monitoring function BATTERY

■ WIFI remote monitoring (Built in wifi module and antenna)


Normal voltage 12VDC 24VDC 24VDC 24VDC 48VDC
■ PV/ AC activation function
■ BMS communication function (CAN Port) Floating Charge Voltage 13.7VDC 27.4VDC 27.4VDC 27.4VDC 54.8VDC

■ Dual output for smart load management


Overcharge Protection 15VDC 30VDC 30VDC 30VDC 60VDC

SOLAR CHARGER &AC CHARGER


Back panel description
Maximum PV Array Open Circuit Voltage 400VDC 400VDC 400VDC 450VDC 450VDC
3.5KW

1 2 4 8 9 10 11
Maximum PV Input Current 16A 18A 18A 18A 28A

1. AC Input Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
2. Main Load
3. Second Load Maximum PV Array Power 2000W 4000W 4000W 4000W 6000W
4. PV Input
PV Array MPPT Voltage Range(Typ.) 30~320VDC 60~360VDC
7 3 6 5
5. ON/OFF Switch
6. DC Input Maximum Solar Charge Current 80A 100A
5.5KW
7. Ground
1 2 3 4 8 9 10 11
8. WiFi antenna Maximum AC Charge Current 80A 60A 60A 60A 100A
9. USB Port
Maximum Charge Current 80A 100A
10. RS-485/CAN Communication port
11. Dry contact MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 367*290*111mm 367*290*111mm 367*290*111mm 367*318*122.5mm 454*318*122.5mm


7 6 5

Solar system connection Package Dimension (W*H*D) 446*394*187mm 446*394*187mm 446*394*187mm 459*410*200mm 544.5*410*200mm

N.W (kg) 6.4kg 6.6kg 6.6kg 7.2kg 9.0kg


PV input
Fridge Lighting Fans G.W (kg) 7.4kg 7.6kg 7.6kg 8.2kg 10.5kg
Solar Panel
Main Load OTHER

AC Input
Humidity 5% to 95% Relative humidity (Non-condensing)

Utility Operating Temperature 0°C~50°C


BAT input
Second Load
Storage Temperature -15℃ ~60℃

TV Air conditioner Washing machine


CERTIFICATION & STANDARDS
Inverter
Generator Battery

Built-in WiFi CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2)

24
Products / 230V

HIGH FREQUENCY SOLAR INVERTER PV18-1012 PV18-1512 PV18-1224 PV18-2224 PV18-3224 PV18-3524 PV18-4024
MODEL
PV1800 VPM ll Series
VPM ll VPM II VPM ll VPM ll VPM ll VPM ll VPM ll

Default Battery System Voltage 12VDC 12VDC 24VDC 24VDC 24VDC 24VDC 24VDC

INVERTER OUTPUT
1~4KW | 24V | 40~60A
Rated Power 1000VA/1000W 1500VA/1500W 1200VA/1200W 2200VA/2200W 3200VA/3200W 3500VA/3500W 4000VA/4000W
This is a multi-function inverter/charger, combining functions of inverter,
MPPT 40A/60A solar charger and battery charger to offer uninterruptible Surge Power 2000VA 3000VA 2400VA 4400VA 6400VA 7000VA 8000VA
power support with portable size. Its comprehensive LCD display offers user-
configurable and easy-accessible button operation such as battery charging Waveform Pure sine wave
current, AC/solar charger priority, and acceptable input voltage based on AC Voltage Regulation (Batt.
different applications. 230VAC
Mode)

Inverter Efficiency(Peak) 90%~93%

Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)

AC INPUT
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
Voltage 230VAC
■ Bult in MPPT 40A/60A solar charge controller

■ Combining solar system, AC utility, and battery power source to Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
supply continuous power
Frequency Range 50Hz / 60Hz (Auto sensing)
■ Overload, short circuit and Deep discharge protection

■ Cold start function BATTERY


■ Support USB, RS485, CAN monitoring function
Normal voltage 12VDC 24VDC
■ WIFI remote monitoring (optional)
Floating Charge Voltage 13.8VDC 27.4VDC
■ Compatible to generator

■ PV/ AC activation function Overcharge Protection 15VDC 30VDC


■ Smart battery pack BMS communication function (CAN Port)
SOLAR CHARGER & AC CHARGER

Maximum PV Array Open


Back panel description Circuit Voltage
105VDC 145VDC 120VDC 160VDC 160VDC 160VDC 160VDC

PV Array MPPT Voltage


15~75VDC 15~130VDC 30~96VDC 30~128VDC 30~128VDC 30~128VDC 30~128VDC
1.2KW Range(Typ.)
1 11 3 2 4 5 6 7 8 9 10
1. AC output Standby Power Consumption 2W

2. AC input
Maximum PV Array Power 600W 720W 1000W 1600W 1600W 1600W 1600W
3. Circuit breaker
4. PV input Maximum Solar Charge Current 45A 60A 40A 60A 60A 60A 60A
5. Battery input
Maximum Efficiency 98%
6. Power on/off switch
3.5KW/4KW
7. Dry contact
Maximum AC Charge Current 20A 20A 30A 40A 60A 60A 60A
3 2 1 11 5 4 6 7 8 9 10 8. USB Communication port
9. RS-485,CAN Communication port Maximum Charge Current 65A 70A 70A 100A 120A 120A 120A
10. USB WiFi port (optional)
MECHANICAL SPECIFICATIONS
11. Ground
Machine Dimension (W*H*D)
224*337*98 255*318*110 224*337*98 367.4*254.5*103 367.4*254.5*103 367.4*318*121 367.4*318*121
(mm)
Package Dimension (W*H*D)
300*410*178 355*402*206 299*292*184 436*331*189 436*331*189 549*410*200 549*410*200
Solar system connection (mm)

N.W (kg) 3.6 5.5 4.7 5.5 5.5 5.9 5.9

PV input
G.W (kg) 4.3 6.0 5.5 6.5 6.5 7.2 7.2
TV Fridge Lighting Fans
OTHER
Solar Panel

Humidity 5% to 95% Relativ Humidity (Non-condensing)


AC Input

Operating Temperature 0°C~50°C


Utility
Storage Temperature -15°C -60°C
BAT input

CERTIFICATION & STANDARDS

Inverter
Generator Battery CE-EMC+LVD(EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2)

26
Products / 230V

HIGH FREQUENCY SOLAR INVERTER


MODEL PV18-2524 VM PV18-3024 VM
PV1800 VM Series Default Battery System Voltage 24VDC

INVERTER OUTPUT
2.5~3KW | 24V | 40~60A
Rated Power 2500VA / 2000W 3000VA / 2500W
This is a multi-function inverter/charger, combining functions of inverter, MPPT
60A solar charger and battery charger to offer uninterruptible power support Surge Power 5000VA 6000VA
with portable size. Its comprehensive LCD display offers user-configurable and
easy-accessible button operation such as battery charging current, AC/solar Waveform Pure sine wave
charger priority, and acceptable input voltage based on different applications.
AC Voltage Regulation (Batt.Mode) 220VAC~240VAC(Setting)

Inverter Efficiency(Peak) 90%~93%

Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)

AC INPUT
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).

■ Bult in MPPT 40A/60A solar charge controller Voltage 230VAC

■ Combining solar system, AC utility, and battery power source to


Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
supply continuous power

■ Overload, short circuit and Deep discharge protection Frequency Range 50Hz / 60Hz (Auto sensing)
■ Cold start function
BATTERY
■ Support USB, RS485, CAN monitoring function

■ WIFI remote monitoring (optional) Normal voltage 24VDC

■ Compatible to generator
Floating Charge Voltage 27.4VDC

Overcharge Protection 30VDC

Back panel description SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage 145VDC

PV Array MPPT Voltage Range 30~120VDC


1. Circuit breaker
2. AC output Standby Power Consumption 2W
1 2 3 4 5 6 7 8 9 10 3. AC input
4. Battery input Maximum PV Array Power 1500W
5. Power on/off switch
6. PV input Maximum Solar Charge Current 60A
7. RS-485,CAN Communication port
Maximum Efficiency 98%
8. USB Communication port
9. Dry contact Maximum AC Charge Current 10A or 20A
10. USB WiFi port (optional)
Maximum Charge Current 70A

MECHANICAL SPECIFICATIONS

Solar system connection Machine Dimension (W*H*D) 225*355*92mm 290*342*125mm

Package Dimension (W*H*D) / /


PV input
TV Fridge Lighting Fans N.W (kg) / /
Solar Panel
G.W (kg) / /
AC Input
OTHER

Utility
Humidity 5% to 95% Relativ Humidity (Non-condensing)
BAT input

Operating Temperature 0°C~50°C

Generator
Inverter
Battery Storage Temperature -15°C -60°C

28
Products / 230V

HIGH FREQUENCY SOLAR INVERTER

PV1900 EXP Series


MODEL PV19-4024 EXP PV19-6048 EXP

Default Battery System Voltage 24VDC 48VDC

INVERTER OUTPUT
4~6KW | 500V | 100~120A | Dual output | WiFi | 9pcs parallel
Rated Power 4000VA / 4000W 6000VA / 6000W
PV1900 EXP is a multi-function inverter/charger, combining functions of
inverter, MPPT solar charger and battery charger to offer uninterruptible power Surge Power 8000W 12000W
support in portable size. PV1900 EXP Series can run without battery.
Waveform Pure sine wave
The Maximum PV array open circuit voltage can reach 500V and MPPT voltage
is 150~450Vdc, which Can help customers make full use of solar energy.
AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)

Inverter Efficiency(Peak) 92%

Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)

■ Pure sine wave output AC INPUT


■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
■ Built-in MPPT solar charge controller Voltage 230VAC
■ MAX PV Array Open Circuit Voltage: 500V (450V for parallel)
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
■ Can provide the power to the load without battery
■ Combining solar system, AC utility, and battery power source to Frequency Range 50Hz / 60Hz (Auto sensing)
supply continuous power
■ Overload, short circuit and Deep discharge protection BATTERY
■ Cold start function
Normal voltage 24VDC 48VDC
■ Support USB, RS485 monitoring function
■ Parallel operation with up to 9 units (for 48V mode) Floating Charge Voltage 27.4VDC 54.8VDC
■ WIFI remote monitoring (optional)
■ Dual outputs for smart load management(optional) Overcharge Protection 30VDC 60VDC
■ Can communicate with lithium batteries
SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage 500VDC (450V for parallel)


Back panel description
Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
4KW
1. AC Input Maximum PV Array Power 5000W 6000W
1 2 3 4 10 9 8 11 12 13
2. AC Output
3. FAN PV Array MPPT Voltage Range 150~450VDC (150~430VDC for parallel)
4. PV Input
Maximum Solar Charge Current 100A 120A
5. Power On/Off Switch
7 6 5 6. Battery Input Maximum AC Charge Current 80A 100A
6KW 7. Circuit breaker
8. Dry Contact Maximum Charge Current 100A 120A
1 2 10 9 8 4 5 13
9. USB
MECHANICAL SPECIFICATIONS
10. RS-485/CAN Communication port
11. Parallel switch (only for parallel model) Machine Dimension (W*H*D) 322*486*134mm 309*505*147mm
12. Parallel communication port (only for parallel model)
Package Dimension (W*H*D) / /
13. Wifi port
7 11 12 6
N.W (kg) / /

Solar system connection G.W (kg) / /

OTHER

PV input
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Fridge Lighting Fans
Solar Panel
Operating Temperature 0°C~50°C
Main Load
AC Input Storage Temperature -15°C -60°C

Utility
CERTIFICATION & STANDARDS
Second Load
BAT input
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
TV Air conditioner Washing machine EN IEC62368-1:2020+A11:2020
Inverter CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
Generator Battery
EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011

30
Products / 230V

HIGH FREQUENCY SOLAR INVERTER


MODEL PV19-6248 EXP PV19-8048 EXP PV19-10048 EXP PV19-12048 EXP

PV1900M EXP Series Default Battery System Voltage 48VDC

INVERTER OUTPUT
6.2~12KW | PV500V | 120A~150A | Dual input | Dual output
Rated Power 6200VA/6200W 8000VA/8000W 10000VA/10000W 12000VA/12000W
PV1900M EXP is a multi-function inverter/charger, combining functions of
Surge Power 12400W 16000W 20000W 24000W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV1900M EXP Series can run without battery. Waveform Pure sine wave
The Maximum PV input voltage can reach 500V and MPPT voltage range
is 90~450Vdc, built-in two MPPTs solar charge controller, which can help AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
customers make full use of solar energy.
Inverter Efficiency(Peak) 92%

Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)

AC INPUT

■ Dual output for smart load management


Voltage 230VAC
■ Dual input for smart AC power management (for 8~12K)
■ Smart color LCD setting (Working modes, Charge Current, Charge Voltage, etc). Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
■ Built-in Two MPPTs solar charge controller
■ Wide MPPT voltage range is 90~450V, the maximum PV input voltage Frequency Range 50Hz / 60Hz (Auto sensing)
can reach 500V (450V for parallel)
■ Can provide the power to the load without battery BATTERY
■ Combining solar system, AC utility, and battery power source to supply
Normal voltage 48VDC
continuous power
■ Overload, short circuit and Deep discharge protection Floating Charge Voltage 54.8VDC
■ With BMS lithium battery communication function
■ With AC/PV lithium battery activation function Overcharge Protection 60VDC
■ Support USB, RS485 monitoring function
■ Parallel operation with up to 3 units (for 48V mode) SOLAR CHARGER & AC CHARGER
■ WIFI remote monitoring (optional)
Maximum PV Array Open Circuit Voltage 500VDC (450V for parallel)

Back panel description Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)

Maximum PV Array Power 4000W*2 4000W*2 6000W*2 6000W*2


8~12KW 6.2KW

Maximum PV Input Current 18A*2 18A*2 27A*2(40A max) 27A*2(40A max)


1 2 3 4 5 6 7 8 9 10 11 13 1 2 3 4 6 7 8 9 10 11 13

PV Array MPPT Voltage Range 90~450VDC (90~430VDC for parallel)

Maximum Solar Charge Current 120A 120A 150A 150A

Maximum AC Charge Current 100A 120A 120A 150A


Left side of inverter Left side of inverter
12 12
Maximum Charge Current 120A 120A 150A 150A
1. Ground 6. AC output 11. Power On/Off Switch
MECHANICAL SPECIFICATIONS
2. PV1 7. RS-485/CAN Communication port 12. Parallel communication port (only for parallel model)
3. PV2 8. USB port 13. Wifi port Machine Dimension (W*H*D) 425*473*145mm 425*527*145mm
4. AC input1 9. Dry Contact
Package Dimension (W*H*D) / / / /
5. AC input2 10. Battery Input
N.W (kg) / / / /
Solar system connection
G.W (kg) / / / /

OTHER
PV1 input
Solar Panel
Fridge Lighting Fans
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Main Load
PV2 input Operating Temperature 0°C~50°C
Solar Panel Second Load
Storage Temperature -15°C -60°C
TV Air conditioner Washing machine

AC Input 1 CERTIFICATION & STANDARDS


Utility

BAT input
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
AC Input 2
EN IEC62368-1:2020+A11:2020
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
Generator Inverter (8~12K) Battery
EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011

32
Products / 230V

LOW FREQUENCY OFF GRID SOLAR INVERTER MODEL PV20-1012 PK PV20-1512 PK PV20-2024 PK

PV2000 PK Series Battery Input Voltage Rating


INVERTER OUTPUT
12VDC 24VDC

1000VA 1500VA 2000VA


Rated Power
1~2KVA | 12V, 24V | 50A PWM
700W 900W 1200W
Instantaneous Power Drawn 2100VA 2700VA 3600VA

PV2000 PK built-in high efficiency solar controller. AC input voltage range Output Waveform Pure sine wave
for 140VAC-280VAC with regulated output (AVR) features, PV, AC function, A Output Voltage Inverter mode: 230VAC(±5% RMS), AVR mode: 200VAC-240VAC 220VAC(±5% RMS)
tracking feature such as power frequency. The output frequency can be set Output Power Factor 0.7 0.6
using the keys, AC /PV charging voltage, charge current, AC or PV priority
Output Frequency 50Hz/60Hz ±0.2 Hz
mode, Battery under voltage shut-down point, and so many other functions.
Inverting Efficiency (peak) >85%
Mains Mode Efficiency > 95%
Transfer Time Typical 2~6ms 10ms(max)
AC INPUT

■ Pure sine wave output Input Voltage 220/230VAC


Input Voltage Range 140~280VAC±5%
■ Built-in 50A PWM solar charge controller
Low Pressure Shutdown 140VAC±5%
■ Smart LCD setting ( frequency , charge voltage, charge current, etc). High Pressure Shutdown 280VAC±5%
Low Frequency Shutdown 45±0.2Hz(50Hz)
■ Overload and short-circuit protection
High Frequency Shutdown 65±0.2Hz(60Hz)
■ Deep discharge protection Frequency Range 50Hz/60Hz ±0.2HZ

■ Cold start function BATTERY


Minimum Start Voltage Battery under voltage shut-down point +0.5V Battery under voltage shut-down point +1.0V
■ Support USB/RS232 monitoring function
Low Battery Alarm Battery under voltage shut-down point +0.5V Battery under voltage shut-down point +1.0V
Low Battery Shutdown (0.1V / 10-12.0VDC mode) User set (0.2V / 20.0-24.0VDC mode) User set
Battery High Voltage Alarm Average Charge Voltage+1V Average Charge Voltage +2V
AC CHARGER
Float Voltage 13.5~14.5VDC to set 27~29VDC to set
Back panel description
Average Charge Voltage (0.1V each click ,13.8~14.5V mode) User set (0.2V each click , 27.6~29V mode) User set
Maximum Charge Current 20A±2A 25A±2A 15A±2A
1. LCD display BYPASS & PROTECTION
2. Fault LED Input Frequency 50Hz / 60Hz
3. Charge LED
Low Frequency Switching 45±1Hz
4. AC/Inverter LED
10 High Frequency Switching 65±1Hz
1 2 3 4 5 5. ESC
Overload Protection 110%~125%R load fault after 60s 125% ~150%R load fault after 3s >150%R load fault after 500ms
6. SEL
Output Short Circuit Protection Yes
7. ENTER
8
8. POWER ON Bypass Circuit Breaker Insurance 10A
6
9. POWER OFF Maximum Current Bypass 10A 10A
9

7
10. USB SOLAR CHARGER
11. PV Input Maximum PV Charge Current 50A±5A
11 12 13 14
12. Battery Input Battery Voltage 12VDC 24VDC
13. AC Input Maximum PV Array Power 150W*5 solar panels 150W*10 solar panels
14. AC Output Maximum PV Array Open Circuit Voltage 55Vdc
Maximum Efficiency > 95%
Solar system connection Standby Consumption <2W
MECHANICAL SPECIFICATIONS
Assembly Wall mount
Machine Dimension (W*H*D) 319*300.5*132.2mm
PV input
TV Fridge Lighting Fans
Package Dimension (W*H*D) 391*325*187mm
Solar Panel N.W (kg) /
G.W (kg) /
AC Input
OTHER
Working Environment 0°C~40°C 0~90% Relative humidity (non-condensing)
Utility
BAT input Noise Less than 60db
Display LED + LCD
Inverter CERTIFICATION & STANDARDS
Generator Battery
CE-EMC+LVD(EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011)

34
Products / 230V

LOW FREQUENCY SOLAR INVERTER PV29- PV29- PV29- PV29- PV29- PV29- PV29-

PV2900 HP Series
MODEL
1KW-HP 1.5KW-HP 2KW-HP 3KW-HP 4KW-HP 5KW-HP 6KW-HP
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT

1~6KW | AC 230V | MPPT80A | WIFI | BMS | Dual output Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
PV2900 HP series is very economical pure sine wave solar inverter, Inbuilt with Capable Of Starting Electric Motor 1P 1P 1.5P 2P 3P
80A MPPT charger; Solar/AC priority is configurable, when setting solar priority, Waveform Pure sine wave / same as input (bypass mode)
solar will charge batteries as first priority, and AC can also charge batteries Nominal Output Voltage RMS 220V / 230V / 240VAC (±10% RMS)
when solar charger current is too lower, in this way system charge is optimazed
Output Frequency 50Hz / 60Hz ±0.3Hz
best. it enables inverter to operate with all kinds of home appliances.
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)

■ 3 Steps charging 100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ Overload and short-circuit protection Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Set charging voltage/charging current Load > 125% (alarm 10s then stop output and fault code 07)
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V AC INPUT
■ Power-save mode
Voltage 230VAC
■ Set utility priority /battery priority
■ Set utility input wide/narrow voltage range Selectable Voltage Range 155~265VAC(For personal computers)
■ Inverter voltage can be set to 220V/230V/240V Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Inverter frequency can be set to 50Hz/60Hz
BATTERY
■ Set utility charging on/off switch
■ Inbuilt 80A MPPT Solar Charge Controller Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Acid or Lithium Select Low Battery Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ WIFI remote monitoring (optional)
Low Battery Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ With BMS lithium battery communication function (CAN port)
■ Dual output for smart load management High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Back panel description Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
1. Power on/off switch Output Voltage Depends on battery type
2. BAT - Overcharge Protection S.D. 15.5VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
1~3KW 4~6KW 3. BAT + Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
4. AC Input PAYPASS & PROTECTION
5. Main load Input Voltage Waveform Sine wave (grid or generator)
1 2 3 4 5 6 7 1 2 3 4 5 6 7 6. Second load Nominal Input Frequency 50Hz or 60Hz
7. PV input
Overload Protection (SMPS Load) Circuit breaker
8. Fan
Output Short Circuit Protection Circuit breaker
9. Remote port
BACK SIDE AC Input Breaker 1-3K/30A 4-6K/50A
10. BMS Can Port
SOLAR CHARGER
11. AGS port
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
12. USB port
Maximum PV Charge Current 80A±4A
13. WIFI port (optional)
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
8 9 10 11 13 12 14 15 8 9 13 12 11 10 16 14. AC input protect
MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
15. AC output 10A(max)
Maximum PV Array Open Circuit Voltage 245VDC
16. AC Input breaker
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall Mount
Dimensions (W*H*D) 274*484*174mm 274*568.5*174mm
PV input Package Dimensions (W*H*D) 583.5*376*255mm 668.5*376*255mm

Fridge Lighting Fans


N.W (kg) / /
Solar Panel
G.W (kg) / /
AC Input
Main Load OTHER
Operation Temperature Range 0℃ to 40℃
Utility Storage Temperature -15℃ to 60℃

BAT input
Second Load Audible Noise 60dB MAX
Display LED+LCD
TV Air conditioner Washing machine
Standard Warranty 1 year
Generator Battery Inverter
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

36
Products / 230V

LOW FREQUENCY SOLAR INVERTER PV30- PV30- PV30- PV30- PV30- PV30- PV30-

PV3000 VHM Series


MODEL 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW
VHM VHM VHM VHM VHM VHM VHM
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT

1~6KW | AC 230V | MPPT80A | WIFI | BAT-CAN Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW


Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
PV3000 VHM series is very economical pure sine wave solar inverter, Inbuilt Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP 3HP
with 80A MPPT charger; Solar/AC priority is configurable, when setting solar Waveform Pure sine wave / same as input (bypass mode)
priority, solar will charge batteries as first priority, and AC can also charge Nominal Output Voltage RMS 220V / 230V / 240VAC (±10% RMS)
batteries when solar charger current is too lower, in this way system charge
Output Frequency 50Hz / 60Hz ±0.3Hz
is optimazed best. it enables inverter to operate with all kinds of home
appliances. Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)

100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ 3 Steps charging Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Overload and short-circuit protection Load > 125% (alarm 10s then stop output and fault code 07)
■ Set charging voltage/charging current
AC INPUT
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
Voltage 230VAC
■ Power-save mode
■ Set utility priority /battery priority Selectable Voltage Range 155~265VAC(For personal computers)
■ Set utility input wide/narrow voltage range Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Inverter voltage can be set to 220V/230V/240V BATTERY
■ Inverter frequency can be set to 50Hz/60Hz Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Set utility charging on/off switch Low Battery Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Inbuilt 80A MPPT Solar Charge Controller Low Battery Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Acid or Lithium Select
High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ WIFI remote monitoring (optional)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ With BMS lithium battery communication function (CAN port)
Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
Back panel description CHARGER
Output Voltage Depends on battery type
1. BAT - Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
1~3KW 4~6KW 2. BAT + Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
3. GND PAYPASS & PROTECTION
1 3 4 5 6 3 7 8 1 3 4 5 6 3 8 4. AC Input Input Voltage Waveform Sine wave (grid or generator)
5. AC Output Nominal Input Frequency 50Hz or 60Hz
6. PV Input Overload Protection (SMPS Load) Circuit breaker
7. AC Input protect Output Short Circuit Protection Circuit breaker
8. Wifi (optional) AC Input Breaker 1-3K/30A 4-6K/50A
9. AC Output 10A(MAX) SOLAR CHARGER
10. USB
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
11. AGS
Maximum PV Charge Current 80A±4A
12. BAT CAN
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
13. Remote port
15 14 13 2 12 11 10 9 15 14 13 2 12 11 10 7 MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
14. FAN
Maximum PV Array Open Circuit Voltage 245VDC
15. Power on/off switch
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall Mount
Dimensions (W*H*D) 493*303*200mm 531*305*202mm

PV input Package Dimensions (W*H*D) 615*400*319mm 686*400*319mm


TV Fridge Lighting Fans N.W (kg) / /
Solar Panel G.W (kg) / /
OTHER
AC Input
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Utility BAT input
Audible Noise 60dB MAX
Display LED+LCD
Standard Warranty 1 year
CERTIFICATION & STANDARDS
Generator Inverter
Battery CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

38
Products / 230V

LOW FREQUENCY SOLAR INVERTER/CHARGER PV30-1K PV30-1.5K PV30-2K PV30-3K


MODEL
PV3000 VPM Series
VPM VPM VPM VPM
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC
INVERTER OUTPUT
Rated Power 1000VA 1500VA 2000VA 3000VA
1~3KVA | 120/230V | 60A MPPT | WiFi | BAT-CAN
Surge Rating 3000VA 4500VA 6000VA 9000VA
Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP
PV3000 VPM series is very economical pure sine wave solar inverter, inbuilt
with 60A MPPT Charger and AC Charger from 20A to 60A; Solar/AC priority Waveform Pure sine wave / same as input (bypass mode)
is configurable, when setting solar priority, solar will charge batteries as first Nominal Output Voltage RMS 110V /115V / 120V / 220V / 230V / 240VAC (±10% RMS)
priority, and AC can also charge batteries when solar charger current is too Output Frequency 50Hz / 60Hz ±0.3Hz
lower, in this way system charge is optimazed best. It enables inverter to
Inverter Efficiency (Peak) >88%
operate with all kinds of home appliances.
Line Mode Efficiency >95%
Power Factor 0.7
■ 3 Steps charging
Typical Transfer Time 10ms(max)
■ Overload and short-circuit protection
■ Set charging voltage/charging current 100% < Load < 110% (alarm 5min then stop output and fault code 07)
Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
Load > 125% (alarm 10s then stop output and fault code 07)
■ Power-save mode
■ Set utility priority/battery priority AC INPUT
■ Set utility input wide/narrow range Voltage 230VAC
■ Inverter voltage can be set to 110V/115V/120V or 220V/230V/240V Selectable Voltage Range 75~135VAC; 155~265VAC (For personal computers)
■ Inverter frequency can be set to 50Hz/60Hz Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Set utility charging on/off switch BATTERY
■ Inbuilt with 60A MPPT Solar Charge Controller
Minimum Start Voltage (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Acid or Lithium Select
Low Battery Alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ WIFI remote monitoring (optional)
■ With BMS lithium battery communication function (CAN port) Low Battery Cut Off 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm (12~14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12~14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
Back panel description
Output Voltage Depends on battery type
120V 1~2K/30A 3K/40A
Charge AC Input Breaker Rating
230V 1~3K/30A
1 3 4 5 6 3 7 8
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode)
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A

1. BAT - 9. AC Output 10A(MAX) BYPASS & PROTECTION


2. BAT + 10. USB Input Voltage Waveform Sine wave (grid or generator)
3. GND 11. AGS Nominal Input Frequency 50Hz or 60Hz
4. AC Input 12. BAT CAN Overload Protection (SMPS Load) Circuit breaker
5. AC Output 13. Remote port Output Short Circuit Protection Circuit breaker
6. PV Input 14. FAN AC Input Breaker 1-3K/30A
7. AC Input protect 15. Power on/off switch SOLAR CHARGER
8. Wifi (optional) Maximum PV Array Power 1000W 2000W 1000W 2000W 1000W 2000W 2000W
Maximum PV Charge Current 60A
15 14 13 2 12 11 10 9
DC Voltage 12V / 24V auto work
MPPT Range @ Operating Voltage 12V: 16~75VDC; 24V: 32-100VDC
Maximum PV Array Open Circuit Voltage 12V:75VDC; 24V:100VDC
Solar system connection
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS

PV input
Mounting Wall Mount
TV Fridge Lighting Fans Dimensions (W*H*D) 493*303*200mm
Solar Panel Package Dimensions (W*H*D) 615*400*319mm
N.W (kg) /
AC Input
G.W (kg) /
OTHER
Utility BAT input
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Audible Noise 60dB MAX
Display LED+LCD
Generator Inverter
Battery
Standard Warranty 1 year

40
Products / 230V

LOW FREQUENCY SOLAR INVERTER MODEL PV36 PRO-8K PV36 PRO-10K PV36 PRO-12K

PV3600 PRO Series Nominal Battery System Voltage


INVERTER OUTPUT
48VDC 48VDC 48VDC

Rated power 8.0KW 10.0KW 12.0KW


8~12KW | 245V | 100A, 200A Surge rating 24000VA 30000VA 36000VA
Capable of starting electric motor 4HP 5HP 6HP
PV3600 PRO series is a multi-function inverter ,combining functions of inverter Waveform Pure sine wave / same as input (bypass mode)
and MPPT solar charger controller, solar charger and battery charger to offer Nominal output voltage RMS 220V / 230V / 240VAC (±10%RMS)
uninterruptible power support. The comprehensive LCD display offers user-
Output frequency 50Hz / 60Hz ± 0.3Hz
configurable and easy-accessible button operation such as battery charging
current, AC/solar charger priority, and selectable input voltage based on Inverter effciency(peak) >88%
different applications. Line mode efficiency >95%
Power factor 1.0
Typical transfer time 20ms(max)
AC INPUT
Voltage 230VAC
■ Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.) Selectable voltage range 90-280 VAC (APL)
■ Built-in MPPT solar charge controller 100A/200A Frequency range 50Hz / 60Hz
■ MPPT efficiency max 98% BATTERY
Low battery voltage cutoff 40-48VDC for 48VDC mode
■ Powerful charge rate up to 140Amp
Low battery voltage recover 42-50VDC for 48VDC mode
■ Inside BMS function
High battery voltage cutoff 60VDC for 48VDC mode
■ DC start &Automatic Self-Diagnostic Function High battery voltage recover 57VDC for 48VDC mode
■ WIFI / USB monitoring function (wi-fi optional) Idle consumption-search mode <80W when power saver on

■ Supporting AGS, BTS port AC CHARGER


Output voltage Depends on battery type
■ Compatible to generator
Charger AC input breaker rating 80A 100A 100A
Overcharge protection S.D. 62.8VDC for 48VDC mode
Maximum charge current 100A 120A 140A

Back panel description BTS


Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
1 2 3 4
Nominal input frequency 50Hz or 60Hz

1. BAT- 9. BTS port Overload protection (SMPS Load) Circuit breaker

2. BAT+ 10. Wifi communication port Output short circuit protection Circuit breaker

3. AC input breaker 11. AC input Bypass breaker rating 80A 100A 100A
4. AC output breaker 12. AC outputr Max bypass current 36A 45A 54.5A
5. Remote control port 13. PV2 input SOLAR CHARGER
6. Fan 14. PV1 input Maximum PV charge current 100A(200A optional)
7. USB port 15. Ground DC voltage 48V
8. AGS port Maximim PV array power 5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC) 64~235VDC
5 6 7 8 9 10 11 12 13 14 15 Maximum PV array open circuit voltage 245VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall mount
Dimensions (W*H*D) 674*402*222mm
Package Dimensions (W*H*D) /
PV input
TV Fridge Lighting Fans N.W (kg) /
G.W (kg) /
Solar Panel
OTHER
Operation temperature range 0°C to 50°C
AC Input
Storage temperature -15°C to 60°C
BAT input
Audible noise 60dB MAX
Utility
Display LED+LCD
Loading (20GP/40GP/40HQ) 140pcs / 280pcs / 320pcs
Inverter
CERTIFICATION & STANDARDS
Generator
Battery
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)

42
Products / 230V

PURE SINE WAVE SOLAR INVERTER MODEL PV50-3K PV50-4K PV50-5K

PV5000 Series Nominal Battery System Voltage 48V

INVERTER OUTPUT
3~5KW | 145V | 80A MPPT
Rated Output Power 3KW 4KW 5KW
This is a multi-function inverter/charger, combining functions of inverter,
solar charger and battery charger to offer uninterruptible power support with Surge Power 6KW 8KW 10KW
portable size. Its comprehensive LCD display offers user-configurable and easy-
accessible button operation such as battery charging current, AC/solar charger Waveform Pure Sine Wave
priority, and acceptable input voltage based on different applications.
Power factor 1

Output Voltage Regulation 230Vac±5%

Inverter Efficiency(Peak) 90%


■ Pure sine wave inverter
Transfer Time 10ms typical (UPS / VDE4105) 20ms typical (APL)
■ Configurable input voltage range for home appliances and personal
computers via LCD setting
AC INPUT
■ Configurable battery charging current based on applications via LCD setting
■ Configurable AC/Solar Charger priority via LCD setting Nominal Input Voltage 230VAC

■ Compatible to mains voltage or generator power


Selectable voltage range 170~280VAC(UPS), 90~280VAC(APL)), 184~253VAC(VDE4105)
■ Auto restart while AC is recovering
■ Overload/ Over temperature/ short circuit protection Input Voltage Waveform Sinusoidal (utility or generator)

■ Smart battery charger design for optimized battery performance


Frequency Range 50Hz / 60Hz
■ Cold start function
■ Built-in MPPT solar charge controller 80A SOLAR CHARGER & AC CHARGER
■ WIFI remote monitoring (optional)
Maximum PV Array Open Circuit Voltage 145VDC

Back panel description MPPT Range @ Operating Voltage 60~130VDC

Standby Power Consumption 2W


11 10 9 8 6 16 1 5
Maximum PV Array Power 4000W

Maximum PV Charge Current: 80A

Maximum Efficiency 98%

Maximum AC Charge Current 60A


15 14 13 12 7 4 3 2

Maximum Charge Current(PC+AC) 80A


1. LCD display 6. Power on/off switch 11. AC input
2. Status indicator 7. Battery input 12. Dry contact MECHANICAL SPECIFICATIONS
3. Charging indicator 8. Parallel communication port (only for parallel mode) 13. USB
Machine Dimension (W*H*D) 400*468*86.3mm
4. Fault indicator 9. Parallel switch 14. RS485 communication port
5. Function buttons 10. AC output 15. Circuit breaker Package Dimension (W*H*D) /
16. PV Input
N.W (kg) 10kg
Solar system connection
G.W (kg /

OTHER

Safety Certification CE
TV Fridge Lighting Fans

PV input

Solar Panel Parallel operation 3 units

Operating Temperature Range -10°C to 40°C


AC Input
BAT input

Storage temperature -15°C~ 60°C


Utility
Inverter
CERTIFICATION & STANDARDS
Battery

Generator EN IEC62368-1

44
Products / 230V

PURE SINE WAVE SOLAR INVERTER MODEL PV50-5248 PRO

PV5000 PRO Series Nominal Battery System Voltage 48VDC

INVERTER OUTPUT
5.2KW | 450V | 100A MPPT Rated Power 5200VA / 5200W

PV5000 PRO is a multi-function inverter/charger, combining functions of Surge Power 10400W


inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV5000 PRO Series can run without battery. Waveform Pure sine wave
The Maximum PV array open circuit voltage can reach 450V and MPPT voltage
is 150~430Vdc, which Can help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)

Inverter Efficiency(Peak) 90%

Transfer Time 10ms (UPS / VDE4105) / 20ms (APL)

AC INPUT
■ Pure sine wave inverter
■ Configurable input voltage range for home appliances and personal Voltage 230VAC±5%
computers via LCD setting
■ Configurable battery charging current based on applications via LCD setting Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)

■ Configurable AC/Solar Charger priority via LCD setting Frequency Range 50Hz / 60Hz(Auto sensing)
■ Compatible to mains voltage or generator power
BATTERY
■ Auto restart while AC is recovering
■ Overload/ Over temperature/ short circuit protection Normal voltage 48VDC
■ Smart battery charger design for optimized battery performance
Floating Charge Voltage 54.8VDC
■ Cold start function
■ Parallel operation with up to 3 units Overcharge Protection 60VDC
■ WIFI remote monitoring (optional)
SOLAR CHARGER & AC CHARGER

Back panel description Maximum PV Array Open Circuit Voltage 450VDC

Maximum PV input voltage 27A


1 2 3 4 5 6
Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)

Maximum PV Array Power 6000W

PV Array MPPT Voltage Range 150~430 VDC

Maximum Solar Charge Current 100A


7 8 9 10 11 12 13 14 15 16 17 18

Maximum AC Charge Current 80A

1. PV Input 7. Ground 13. RS485 communication port Maximum Charge Current 100A
2. AC input 8. Input breaker 14. WiFi port
3. AC output 9. Fault indicator 15. USB port MECHANICAL SPECIFICATIONS
4. LCD display 10. Charging indicator 16. Dry contact
Machine Dimension (W*H*D) 400*468*86.3mm
5. Parallel switch 11. Status indicator 17. Battery input
6. Parallel communication port (only for parallel mode) 12. Function buttons 18. Power on/off switch Package Dimension (W*H*D) /

Solar system connection N.W (kg) 14.4kg

G.W (kg /

OTHER
TV Fridge Lighting Fans

PV input Parallel operation 3 units

Solar Panel
Humidity 5% to 95% Relative humidity (Non-condensing)

AC Input Operating Temperature 0°C~50°C


BAT input

Utility
Storage Temperature -25℃ ~60℃
Inverter
CERTIFICATION & STANDARDS
Battery

Generator CE/IEC

46
Products / 230V

HIGH FREQUENCY POWER INVERTER/CHARGER MODEL EP11-1200 PRO EP11-2400 PRO

EP1100 Pro Series Nominal Battery System Voltage 12VDC 24VDC

INVERTER OUTPUT

Rated Power 1200VA / 720W 2400VA / 1440W


1.2~2.4KVA | 12V/24V
Waveform Modified Sine Wave
EP1100 Pro 1200VA/2400VA is a modified sine wave inverter applied to TV, Nominal Output Voltage RMS 230V
stereos, laptops, and desktop computers and other home appliances. It will
Output Voltage Regulation +10/-18%
automatically switch to inverter and provide power when AC is interrupted
unexpectedly.It's perfect for the user who need a simple and economical Output Frequency 50Hz / 60Hz±0.5Hz
inverter,with user-friendly installnation and setting.
Inverter Efficiency (Peak) >80%

Line Mode Efficiency >95%

Power Factor 0.6

Typical Transfer Time Typical 15~20ms 40ms max


■ Rated power 1.2KVA to 2.4KVA
AC INPUT
■ Modified sine wave inverter
Voltage 220 / 230 / 240VAC
■ Double layers PCB board.
Narrow 170~280VAC
■ Configurable input voltage ranges(90-280VAC/170-280VAC) via LCD setting Selectable Voltage Range
Wide 90~280VAC
■ Display accumulated working time
Frequency Range 50Hz / 60Hz(Auto sensing)
■ 3 steps charging algorithm
BATTERY
■ Auto restart while AC recovery
Nominal Input Voltage 12VDC 24VDC
■ Overload & short-circuit protection, Battery reverse polarity protection,
Deep discharge protection Minimum Start Voltage 10.5VDC 21.0VDC

■ Advanced technology optimizes battery life Low Battery Alarm 10.5VDC±0.2V 21.0VDC±0.4V

■ Automatic line-to-battery switchover Low Battery Cutoff 10.0VDC±0.2V 20.0VDC±0.4V

High Voltage Alarm 16.0VDC±0.2V 32.0VDC±0.4V


Back panel description High Battery Voltage Recover 15.0VDC±0.2V 30.0VDC±0.4V

CHARGER

Boost Voltage (Vbat<12.5V) 14.4VDC±0.2V 28.8VDC±0.4V


2
Float Voltage (Vbat>12.5V) 13.7VDC±0.2V 27.4VDC±0.4V
1 3

Charging Current 10A 10A±2A


4

6
Charging Current 20A 20A±2A
5 7 Overcharge Protection S.D. 15.5VDC±0.4A 31VDC±0.8A
8
BYPASS & PROTECTION
9 10 11 12
Nominal Input Frequency 50Hz or 60Hz

Overload Protection (SMPS Load) FUSE


1. Fault LED 5. Set Key 11. AC Input
Output Short Circuit Protection 10A
2. Inverter Mode LED 6. Flip Key 12. Output Receptacle(s)
3. Line Mode LED 7. Enter Key 13. Fan Bypass Fuse Rating 10A

4. LCD Display 8. ON / OFF 14. DC Input Connector (Battery Terminal) Max Bypass Current 10A

MECHANICAL SPECIFICATIONS
Solar system connection Machine Dimension (W*H*D) 246*253*87mm

Package Dimension (W*H*D) 394*347*715mm (6pcs)

N.W (kg) ≈2.675kg ≈2.775g


TV Laptop Lighting Fans
PV input G.W (kg) ≈3.175kg ≈3.275kg

Solar Panel MPPT solar charge OTHER


controller
Operation Temperature Range 0℃ to 40℃

Audible Noise 60dB MAX


AC Input
Display LED+LCD
Utility

Standard Warranty 1 year


BAT input Inverter
CERTIFICATION & STANDARDS
Generator
IEC60950-1+A1+A2

48
Products / 230V

HIGH FREQUENCY POWER INVERTER/CHARGER MODEL EP15-0612 EP15-1012 EP15-1512 EP15-2024

EP1500 Series Nominal Battery System Voltage 12VDC 12VDC 12VDC 24VDC

INVERTER OUTPUT
Rated Power 600VA / 600W 1000VA / 600W 1500VA / 1000W 2000VA / 1500W
0.6~2KVA | 12V/24V | 230V
Waveform Pure Sine Wave

EP1500 series is a pure sine wave inverter applied to TV, stereos, laptops, and Nominal Output Voltage RMS 230V
desktop computers and other home appliances. It will automatically switch to Output Voltage Regulation +10/-18%
inverter and provide power when AC is interrupted unexpectedly.It's perfect
for the user who need a simple and economical inverter,with user-friendly Output Frequency 50Hz / 60Hz ±1Hz
installation and setting. Inverter Efficiency (Peak) >90%

Line Mode Efficiency >95%

Typical Transfer Time <10ms typical, 20ms max

AC INPUT

■ Pure sine wave inverter Voltage 230VAC

■ Low shutdown loss for energy storage system application Voltage Range 184~278VAC ±3% 176~278VAC ± 3%
■ Support two kinds of batteries: Lithium Battery Pack and Lead-acid Battery Frequency Range 45~65Hz ± 2Hz
■ Support fast max charging current setting
BATTERY
■ Different charging mode for different kinds of batteries
■ Auto restart while AC recovery Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack - 12V(4 Series) 24V(8 Series)
■ Overload & short-circuit protection, Battery reverse polarity protection, Nominal Input Voltage 12VDC 12VDC 12VDC 24VDC
Deep discharge protection
■ Advanced technology optimizes battery life Low Battery Cutoff 10.5VDC(PB) 11.5VDC(LI) 10.5VDC(PB) 11.5VDC(LI) 10.5VDC(PB) 11.5VDC(LI) 21.0VDC(PB) 23.0VDC(LI)

■ Automatic line-to-battery switch over Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 11.0VDC(PB) 12.0VDC(LI) 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)
■ Automatic activate lithium battery pack which is be over discharged Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 12.5VDC(PB) 12.8VDC(LI) 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)
no output when AC input is OK
High Voltage Alarm 14.5VDC(PB) 14.5VDC(LI) 14.5VDC(PB) 14.5VDC(LI) 14.5VDC(PB) 14.5VDC(LI) 29.0VDC(PB) 29.0VDC(LI)

High Battery Voltage Recover 15.0VDC(PB) 14.8VDC(LI) 15.0VDC(PB) 14.8VDC(LI) 15.0VDC(PB) 15.0VDC(LI) 30.0VDC(PB) 29.6VDC(LI)
Back panel description
CHARGER

1 2 Boost Voltage 14.4VDC(PB) 14.4VDC(LI) 14.4VDC(PB) 14.4VDC(LI) 14.4VDC(PB) 14.4VDC(LI) 28.8VDC(PB) 28.8VDC(LI)

Float Voltage 13.8VDC(PB) 14.4VDC(LI) 13.8VDC(PB) 14.4VDC(LI) 13.8VDC(PB) 14.4VDC(LI) 27.6VDC(PB) 28.8VDC(LI)
1. ON / OFF
2. LCD Screen Charging Current 7A±2A @ 12V 10A±2A @ 12V 10A±2A @ 12V 7A±2A @ 24V
3. DC Input Connector (Battery Terminal) Charging Current 15A±2A @ 12V 20A±2A @ 12V 20A±2A @ 12V 15A±2A @ 24V
4. Charging max current setting switch
Overcharge Protection S.D. 15.5VDC 15.5VDC 15.5VDC 31VDC
5. Battery kind setting switch
BYPASS & PROTECTION
3 4 5 6 7 6. Output Receptacle(s)
7. AC Input with fuse box Nominal Input Frequency 50Hz / 60Hz (Auto sensing)

Overload Protection (SMPS Load) FUSE

Output Short Circuit Protection 7A 6.3A 10A 10A

Bypass Fuse Rating 7A 6.3A 10A 10A

AC Output Socket types Max Bypass Current 7A 6.3A 10A 10A

MECHANICAL SPECIFICATIONS

Material selection Solar system connection Dimensions (W*H*D) (mm) 320*231*96mm 255*80*224mm

Package Dimensions (W*H*D) (mm) 415*280*166mm 332*127*288mm(1pcs); 400*596*347mm(6pcs)

Metal case Plastic case N.W (kg) 3.4kg 2.3kg


PV input TV Lighting Fans
G.W (kg) 3.7kg 16kg(6pcs)
Solar Panel MPPT solar charge
controller Material Metal case Plastic case Plastic case Plastic case

OTHER

Operation Temperature Range 0℃ to 40℃

Audible Noise 60dB MAX


Inverter

BAT input AC Input


Display LED+LCD
Utility Standard Warranty 1 year

CERTIFICATION & STANDARDS


Generator
EN IEC62368-1+A11

50
Products / 230V

HIGH FREQUENCY POWER INVERTER/CHARGER


MODEL EP18-1012 EP18-2024 EP18-3024 EP18-4048 EP18-5048
EP1800 Series Nominal Battery System Voltage 12VDC 24VDC 48VDC

INVERTER OUTPUT
1~5KW | 12V/24V/48V | 230V
Rated Power 1000W 2000W 3000W 4000W 5000W

This is a multi-function inverter/charger, combining functions of inverter, Surge Power 2000W 4000W 6000W 8000W 10000W
battery charger to offer uninterruptible power support with portable size.
Its comprehensive LCD display offers user-configurable and easy-accessible Waveform Pure sine wave
button operation such as battery charging current,
AC charger priority, and acceptable input voltage based on different Output Voltage Regulation 230Vac±5%
applications.
Output Frequency 60Hz or 50Hz

Inverter Efficiency (Peak) 90%

Transfer Time 10ms typical (UPS,VDE); 20ms typical (APL)


■ Pure sine wave inverter
AC INPUT
■ Configurable input voltage range for home appliances and personal
computers via LCD setting Nominal Input Voltage 230VAC
■ Configurable battery charging current based on applications
via LCD setting Selectable Voltage Range 170~280VAC(UPS), 90~280VAC(APL), 184~253VAX(VDE)
■ Configurable AC Charger via LCD setting
Frequency Range 50Hz/60Hz (Auto sensing)
■ Compatible to mains voltage or generator power
■ Auto restart while AC is recovering BATTERY

■ Overload/ Over temperature/ short circuit protection Nominal voltage 12VDC 24VDC 48VDC
■ Smart battery charger design for optimized battery performance
Floating Charge Voltage 13.7VDC 27.4VDC 54.8VDC
■ Cold start function
■ With BMS lithium battery communication function (CAN port) Overcharge Protection 15VDC 30VDC 60VDC

CHARGER

Back panel description Charging Current @ Nominal Input Voltage 10/20A 20/30A 20/30A 1~60A

Charging Algorithm 3-Step(Flooded Battery, AGM/Gel/LEAD Battery),4-Step(LI)


1 2 3 4 5 6 7
Max Charging Current 20A 30A 30A 60A

Default Charging Current 10A 20A 20A 30A

PROTECTION

Nominal Input Frequency 50Hz / 60Hz (Auto detection)


10 9 8
Output Short Circuit Protection Line mode: Circuit Breaker; Battery mode: Electronic Circuits
1. Circuit breaker 5. USB port 9. Parallel communication port (only for parallel model)
MECHANICAL SPECIFICATIONS
2. AC input 6. Dry contact 10. Parallel switch
3. AC output 7. Power on/off switch Machine Dimension (W*H*D) 240*316*95mm 272*355*100mm 297.5*468*125mm
4. RS485 communication port 8. Battery input
Package Dimension (W*H*D) /

N.W (kg) /
Solar system connection
G.W (kg) /

OTHER
PV input
Operation Temperature Range -10℃ to 50℃
TV Laptop Air-conditioning Washing machine

Solar Panel
Storage temperature -15°C~ 60°C
MPPT solar charge
controller
Audible Noise 60dB MAX

Display LED+LCD
AC Input

Inverter Utility Standard Warranty 1 year

BAT input
CERTIFICATION & STANDARDS
Generator
CE-EMC+LVD (EN6100-6-4, EN6100-6-2+EN IEC62109-1

52
Products / 230V

HIGH FREQUENCY POWER INVERTER/CHARGER


MODEL EP18-5248 PRO
EP1800 PRO Series Rated output power 5200VA/5200W

Surge Power 10400W


5.2KW | 48V | 230V
AC INPUT

This is a multi-function inverter/charger, combining functions of inverter, Nominal Input Voltage 230Vac±5%
battery charger to offer uninterruptible power support with portable size.
Its comprehensive LCD display offers user-configurable and easy-accessible Selectable Voltage range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
button operation such as battery charging current,
Frequency Range 50Hz/60Hz (Auto sensing)
AC charger priority, and acceptable input voltage based on different
applications. Inverter Efficiency(Peak) 90%

INVERTER OUTPUT

Output voltage waveform Pure sine wave

■ Pure sine wave inverter Output Voltage Regulation 230Vac ± 5%


■ Configurable input voltage range for home appliances and personal
Output Frequency 50Hz / 60Hz(Auto sensing)
computers via LCD setting
■ Configurable battery charging current based on applications Power Factor ≈1
via LCD setting
■ Configurable AC Charger via LCD setting Transfer Time 10ms (UPS / VDE4105) / 20ms (APL) <50ms(For parallel operation)
■ Compatible to mains voltage or generator power
Nominal DC Input Voltage 48VDC
■ Auto restart while AC is recovering
■ Overload/ Over temperature/ short circuit protection Cold Start Voltage 46VDC
■ Smart battery charger design for optimized battery performance Output Short Line mode Circuit Breaker
■ Acid or Lithium select Circuit
■ Parallel operation with up to 3 units Protection Battery mode Electronic Circuits
■ WIFI remote monitoring (optional) BATTERY
■ With BMS lithium battery communication function (CAN port)
Battery voltage 48VDC

Back panel description Floating voltage 54.8V

Overcharge Protection 60V


1 2 3 4 5 6 7 11
CHARGER

Charging Current(UPS) @Nominal Input Voltage Default:30A; MAX:80A

Bulk Charging Voltage 56.4Vdc

Floating Charging Voltage 54Vdc

10 9 8 Charging Algorithm 3-Step

1. Circuit breaker 5. USB port 9. Parallel communication port (only for parallel model) GENERAL
2. AC input 6. Dry contact 10. Parallel switch
Mounting Wall mount
3. AC output 7. Power on/off switch 11. WiFi port (optional)
4. RS485 communication port 8. Battery input Display LED+LCD

Parallel operation 3 units

Solar system connection Operation Temperature Range -10℃ to 50℃

Storage Temperature -15℃ to 60℃

Standard Warranty 1 year


PV input
TV Laptop Air-conditioning Washing machine
MECHANICAL SPECIFICATIONS
Solar Panel

Machine Dimension (W*H*D) 297.5*468*125mm


MPPT solar charge
controller
Package Dimension (W*H*D) /

AC Input
N.W /

Inverter Utility G.W /


BAT input
CERTIFICATION & STANDARDS
Generator
CE

54
Products / 230V

POWER INVERTER/CHARGER MODEL


EP20-0312 EP20-0412 EP20-0512 EP20-0612 EP20-0812 EP20-1012 EP20-0624 EP20-0824 EP20-1024

EP2000 PRO Series


PRO PRO PRO PRO PRO PRO PRO PRO PRO

Default Battery System Voltage 12VDC 24VDC


INVERTER OUTPUT
Rated Power 300W 400W 500W 600W 800W 1000W 600W 800W 1000W
300W~1000W | 12V/24V | 10~30A Surge Rating 900VA 1200VA 1500VA 1800VA 2400VA 3000VA 1800VA 2400VA 3000VA
Waveform Pure sine wave
EP2000 PRO series inverter is a cost effective, intelligent with UPS function. Voltage Regulation Battery mode: 220 or 230VAC Line mode: 220~240VAC
The comprehensive LCD offers user-configurable and easy-accessible button Output Frequency 50Hz / 60Hz
adjustment such as battery charge current, battery charge voltage, frequency, Invertert Frequency (Peak) >75% >81%
buzzer etc. It's perfect for the user who need a simple and economical Bypass Efficiency >95%
inverter,with user-friendly installnation and setting.Tower and rack design Output Transfer Time Typical:8ms 12ms(max)
available for different choices. AC INPUT
Voltage 220 / 230 / 240VAC
Selectable Voltage Range 140~280VAC ±5%
Low Battery Alarm 140VAC ±5%
Low Voltage Recover 150VAC ±5%
High Battery Alarm 280VAC ±5%
■ Rated power 300W to 1000W High Voltage Recover 270VAC ±5%
■ Pure sine wave output Low Frequency Alarm 45 ±5Hz
■ Smart LCD setting ( frequency , charge voltage,charge current, etc). Low Frequency Recover 46 ±5Hz
■ 3 steps charging algorithm High Frequency Alarm 65 ±5Hz
■ Built in AVR function High Frequncy Recover 64 ±5Hz
■ Overload and short-circuit protection Nominal Input Range 50Hz / 60Hz ±5Hz
■ Battery reverse polarity protection (Optional) AC Auto Restart YES
■ Deep discharge protection BATTERY
■ Cold start function Minimum Start Voltage Low Battery Voltage Cutoff+0.5V Low Battery Voltage Cutoff+0.5V
Low Battery Alarm Low Battery Voltage Cutoff+0.5V Low Battery Voltage Cutoff+1.0V
Min battery voltage for power on Shutdown voltage +0.5V Shutdown voltage +1V
Low Battery Cutoff 10-12.0VDC 20.0-24.0VDC
High Battery Alarm (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC)
AC CHARGE
Floating Voltage 13.5-14.5VDC 27-29VDC
Back panel description
Boost Voltage 13.8~14.5VDC 27.6~29VDC
300W 400W 500W 600W 800W 1000W 600W 800W 1000W
1. LCD display Maximum Charge Current
10A 10A 15A 20A 25A 30A 10A 15A 15A
2. Fault LED BYPASS & PROTECTION
3. Charge LED Input Waveform Pure sine wave
1 2 3 4 5 10
4. AC/Inverter LED Input Frequency 50Hz or 60Hz
5. ESC Overload Protection >110%~125% Load foult affter 60s; >125%~150% Load foult affter 3s; >150% Load fault after 500ms
8 6. SEL Over Temperature Protection ≥90℃
6
7. Enter Bypass Output Protection 10A 250VAC
9
8. Power on Output Circuit Protection YES
7
9. Power off Battery Reverse Protection Optional
Battery Low Voltage Protection YES
11 12 13 10. USB
Battery High Voltage Protection YES
11. Battery input
Bypass Breaker Rating 10A
12. AC input
Maximum Bypass Current 10A
13. AC output
MECHANICAL SPECIFICATION
Machine Dimension (W*H*D) 319*300.5*132.2mm
Solar system connection Package Dimension (W*H*D) 391*325*187mm
G.W (kg) /
N.W (kg) /
Operating Temperature 0℃ ~40℃ 0~90% relative humidity (non-condensing)
PV input
Storage Temperature -15℃ to 55℃
TV Laptop Lighting Fans
Altitude ≤1000M
Solar Panel MPPT solar charge Audible Noise ≤60dB
controller
Display LED+LCD
Cooling Mode Fan cooling
Fan Starting >45℃ starting, <30℃ Closing
AC Input
Communication USB
Inverter Utility
CERTIFICATION & STANDARDS
BAT input CE-LVD (EN IEC62109-1:2010,EN IEC62109-2:2011)
CE-EMC+LVD (EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011)
Generator IEC60950-1:2005A+1:2009+A2:2013
EN IEC62040-1:2019

56
Products / 230V

POWER INVERTER/CHARGER MODEL


EP20-0312 EP20-0612 EP20-0812 EP20-1012 EP20-0324 EP20-0624 EP20-0824 EP20-1024

EP2000 PRO Series


PRO PRO PRO PRO PRO PRO PRO PRO
Default Battery System Voltage 12VDC 24VDC
INVERTER OUTPUT
Rated Power 300W 600W 800W 1000W 300W 600W 800W 1000W
Surge Rating 900VA 1800VA 2400VA 3000VA 900VA 1800VA 2400VA 3000VA
300W~1000W | 12V/24V | 10~30A Waveform Pure sine wave
Voltage Regulation Battery mode: 220 or 230VAC Line mode: 220~240VAC
EP2000 PRO series inverter is a cost effective, intelligent with UPS function. Output Frequency 50Hz / 60Hz
The comprehensive LCD offers user-configurable and easy-accessible button Invertert Frequency (Peak) >75% >81%
adjustment such as battery charge current, battery charge voltage, frequency, Bypass Efficiency >95%
buzzer etc. It's perfect for the user who need a simple and economical Output Transfer Time Typical:8ms 12ms(max)
inverter,with user-friendly installnation and setting.Tower and rack design AC INPUT
available for different choices.
Voltage 220 / 230 / 240VAC
Selectable Voltage Range 140~280VAC ±5%
Low Battery Alarm 140VAC ±5%
Low Voltage Recover 150VAC ±5%
High Battery Alarm 280VAC ±5%
High Voltage Recover 270VAC ±5%
■ Rated power 300W to 1000W Low Frequency Alarm 45 ±5Hz
■ Pure sine wave output Low Frequency Recover 46 ±5Hz
■ Smart LCD setting ( frequency , charge voltage,charge current, etc). High Frequency Alarm 65 ±5Hz
■ 3 steps charging algorithm High Frequncy Recover 64 ±5Hz
■ Built in AVR function Nominal Input Range 50Hz / 60Hz ±5Hz
■ Overload and short-circuit protection AC Auto Restart YES
BATTERY
■ Battery reverse polarity protection (Optional)
Minimum Start Voltage Low Battery Voltage Cutoff+0.5V Low Battery Voltage Cutoff+1.0V
■ Deep discharge protection
Low Battery Alarm Low Battery Voltage Cutoff+0.5V Low Battery Voltage Cutoff+1.0V
■ Cold start function
Low Battery Cutoff 10-12.0VDC 20.0-24.0VDC
High Battery Alarm (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC)
AC CHARGE
Back panel description Floating Voltage 13.5-14.5VDC 27-29VDC
Boost Voltage 13.8~14.5VDC 27.6~29VDC
300W 600W 800W 1000W 300W 600W 800W 1000W
Maximum Charge Current
10A 20A 25A 30A 5A 10A 15A 15A
1 3
11 BYPASS & PROTECTION
1 2 6 9 17 4 15
2 12 Input Waveform Pure sine wave
5 16
6
Input Frequency 50Hz or 60Hz
7 8
Overload Protection 110%~125% Load foult affter 60s; 125%~150% Load foult affter 3s; >150% Load fault after 500ms
9 18
13 17 Over Temperature Protection ≥90℃
10
Bypass Output Protection 10A 250VAC
14 Output Circuit Protection YES
18 5 8 10 7 13 14 15 16 Battery Reverse Protection Optional
Battery Low Voltage Protection YES
EP2000 PRO (Rack) EP2000 PRO (Tower) Battery High Voltage Protection YES
Bypass Breaker Rating 10A
1. LCD display 6. ESC 11. Fax / Tel 16. Fan Maximum Bypass Current 10A
2. AC Input LED 7. SEL 12. USB 17. AC output MECHANICAL SPECIFICATION
3. Bypass LED 8. ENTER 13. AC Input 18. Battery LED Machine Dimension (W*H*D) 315*145*210mm
4. AC output LED 9. Power On 14. Battery input 300W 600W 800W 1000W 300W 600W 800W 1000W
N.W
7.5kg 10.7kg 12.5kg 13.5kg 7.5kg 10.7kg 12.5kg 13.5kg
5. Fault LED 10. Power Off 15. RS232
Package Dimension (W*H*D) 420*280*225mm
300W 600W 800W 1000W 300W 600W 800W 1000W
G.W
Solar system connection 8kg 11.5kg 13kg 14.0kg 8kg 11.5kg 13kg 14.0kg
OTHER
Operating Temperature 0℃ ~40℃ 0~90% relative humidity (non-condensing)
Storage Temperature -15°C to 55°C
Altitude ≤1000M
Audible Noise ≤60dB
Solar Panel MPPT Solar Charge Grid Generator Display LED+LCD
Controller
Cooling Mode Fan cooling
Fan Starting >45℃ starting, <30℃ Closing
Communication USB
CERTIFICATION & STANDARDS
CE-LVD (EN IEC62109-1:2010,EN IEC62109-2:2011)
CE-EMC+LVD (EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011)
IEC60950-1:2005A+1:2009+A2:2013
Battery Inverter Appliance EN IEC62040-1:2019

58
Products / 230V

LOW FREQUENCY PURE SINE WAVE INVERTER EP30-8048 EP30-10048 EP30-12048


MODEL
EP3000 PRO Series
PRO PRO PRO
Nominal Battery System Voltage 48VDC 48VDC 48VDC
INVERTER OUTPUT
Continuous output power 8.0KW 10.0KW 12.0KW
8~12KW | 48V | 100~140A
Surge rating 24000VA 30000VA 36000VA
Capable Of Starting Electric Motor 4HP 5HP 6HP
Low frequency pure sine wave combined inverter&A/C charger EP3000 PRO
Series 8~12kw; Quiet,high efficiency operation front panel LED+LCD indicators Output waveform Pure sine wave / same as input (bypass mode)
and adjustable switch selectors selectable settings for flooded lead acid,Gel,or Inverter Efficiency(Peak) >88%
absorbed glass mat(AGM) batteries. Mainly for home and office applicances
Line mode efficiency >95%
such as TV, refrigerator, fans lights and computers etc.
Power factor 1.0
Nominal output voltage RMS 220V / 230V / 240VAC ±10% (RMS)
Output frequency 50Hz
Short circuit protection Yes (1sec after fault)
Typical transfer time 10ms(max)
AC INPUT
■ Rated power 8KW to 12KW
Voltage 90-280VAC
■ Pure sine wave output Selectable Voltage Range 170-280VAC(For Personal Computers)

■ Max 140A automatic 3-stage battery charger Frequency Range 50Hz / 60Hz
BATTERY
■ Charger current is Adjustable (0-100%)
Minimum start voltage 40.0V±0.6 / 42.0V±0.6
■ Automatically send signal to start generator Low battery alarm 42-50VDC
Low battery Cutoff 40.0V±0.6 / 42.0V±0.6
■ Supporting USB communication and BTS & AGS port
High voltage alarm 60VDC
■ Battery/AC priority High battery voltage recover 57VDC
Idle consumption-search mode <60W when power saver on
CHARGER
Back panel description
Output voltage Depends on battery type
Charger AC input breaker rating 80A
1 2 6 3 4 5
Max charge power rate 1/3 Rating power
Overcharge protection S.D. 62.8VDC
Maximum Charge Current 100A 120A 140A
1. Power saver on/off switch 10. AC input/output breaker
BTS
2. Inverter indicator 11. Ground
3. Grid indicator 12. AC output Temperature rate @25°C 4mv charging voltage descent, per 1℃ rise
7 8 9 10
4. Fault indicator 13. AC input BYPASS & PROTECTION
5. Function 14. WIFI Communication port Input voltage waveform Sine wave (grid or generator)
6. LCD display 15. USB Communication port Nominal voltage 220V / 230V / 240VAC
7. Remote panel 16. AGS Communication port Max input AC voltage 300VAC for 230VAC HV mode
8. BAT- 17. BTS Communication port Nominal input frequency 50Hz or 60Hz
9. BAT+ 18. FAN Overload protection (SMPS load) Circuit breaker
Output short circuit protection Circuit breaker
18 17 16 15 14 13 12 11 Bypass breaker rating 63A
Max bypass current 63Amp
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall mount
Machine Dimension (W*H*D) 670*410*215mm
Package Dimension (W*H*D) / / /
PV input
N.W /
TV Laptop Air-conditioning Washing machine
G.W / / /
Solar Panel MPPT solar charge OTHER
controller
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
AC Input Audible Noise 60bB MAX
Inverter Utility Display LED+LCD
BAT input Loading(20GP/40GP/40HQ) 200pcs / 400pcs / 500pcs
CERTIFICATION & STANDARDS
Generator
//////////

60
Products / 230V

LOW FREQUENCY POWER INVERTER EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30-

EP3000 PLUS Series


MODEL 1012 1024 1512 1524 2012 2024 3024 3048 4024 4048 5048 6048
PLUS PLUS PLUS PLUS PLUS PLUS PLUS PLUS PLUS PLUS PLUS PLUS
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
1~6kW | 230V | WIFI | BAT-CAN
Rated Power 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW

EP3000 PLUS series is a very economical pure sine wave inverter, with AC Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
charger from 20A to 60A; Solar/AC priority is configurable, when setting Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP 3HP
solar priority, solar will charge batteries as first priority, and AC can also Waveform Pure sine wave / same as input (bypass mode)
charge batteries when solar charger current is too lower . With pure copper
transformer, it enables inverter to operate with all kinds of home appliances. Nominal Output Voltage RMS 220V / 230V / 240VAC ±10% (RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%

■ 3 Steps charging Power Factor 1.0


■ Overload and short-circuit protection Typical Transfer Time 10ms(max)
■ Set charging voltage/charging current. 100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5V/ 12V Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Power-save mode Load > 125% (alarm 10s then stop output and fault code 07)
■ Set utility priority/ Battery priority AC INPUT
■ Set utility input wide/narrow range Voltage 230VAC
■ Inverter voltage can be set to 220V:220V/230V/240V
Selectable Voltage Range 155~265VAC(For personal computers)
■ Inverter frequency can be set to 50/60Hz
Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Set utility charging on/off switch
BATTERY
■ Acid or Lituium select
■ WIFI remote monitoring (optional) Minimum Start Voltage (10V/ 10.5V/ 11V/ 11.5/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ With BMS lithium battery communication function (CAN port) Low Battery Alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Back panel description High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
1~3K 4~6K
Idie Consumption-Search Mode Load ≤100±20W(220V)
13 1 14 3 4 5 2 3 6 13 1 14 3 4 5 2 3 6
CHARGER
Output Voltage Depends on battery type
7 Charge AC Input Breaker Rating (230V) 1-3K/30A 4-6K/50A

8 8 Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
9 9
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
10 10
11 11 BYPASS & PROTECTION
12 12
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
1. BAT - 6. AC input protect 11. USB port
2. BAT + 7. AC Output 10A(MAX) 12. WiFi port Output Short Circuit Protection Circuit breaker
3. GND 8. Remote port 13. Power on/off switch AC Input Breaker 1-3K/30A 4-6K/50A
4. AC input 9. BAT CAN 14. FAN MECHANICAL SPECIFICATIONS
5. AC output 10. AGS Mounting Wall Mount
Machine Dimension (W*H*D) 493*303*200mm 531*305*202mm

Solar system connection Package Dimension (W*H*D) 615*400*319mm 686*400*319mm


N.W 14.8kg 15kg 18.8kg 17.1kg 19.5kg 18.6kg 20.3kg 20.1kg 31kg 29.5kg 30.9kg 34.5kg
G.W 16.3kg 16.5kg 20.3kg 18.6kg 21kg 20.1kg 21.8kg 21.6kg 32.5kg 31kg 32.4kg 36kg
PV input OTHER
TV Laptop Lighting Fans
Operation Temperature Range 0℃ to 40℃
Solar Panel MPPT solar charge
controller Storage Temperature -15℃ to 60℃
Audible Noise 60dB MAX
Display LED+LCD
AC Input
Standard Warranty 1 year, 2 or 3 years optional (IP20)
Utility
Inverter CERTIFICATION & STANDARDS
BAT input

CE-EMC+LVD(EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2)


Generator IEC60950-1 A1+A2; CE-EMC+LVD,EN62040-2,EN62040-1

62
Products / 230V

HIGH FREQUENCY POWER INVERTER


MODEL EP50-3KW EP50-4KW EP50-5KW

EP5000 Series Rated output power 3000W 4000W 5000W

AC INPUT
3~5KW | 230V | WIFI | BAT-CAN
Nominal Input Voltage 230Vac±5%
This is a multi-function inve inverter/charger ,combining Functions of inverter,
battery charger to offfer uninte uninterruptible power with portable size. Its Selectable Voltage range AC 185V~270V
comprehensive LCD display offers user-configurable and easy-accessible
Frequency Range 50Hz/60Hz (Auto sensing)
button operation such as battery charging current, AC charger, and acceptable
input voltage based on different applications.
Inverter Efficiency(Peak) 97%

INVERTER OUTPUT

Output voltage waveform Pure sine wave

Output Voltage Regulation 220Vac ± 5%


■ Pure sine wave inverter
Output Frequency 50Hz
■ Configurable input voltage range For home appliances and personal
computers via LCD setting Configurable battery charging current
based on applications via LCD setting Power Factor 1

■ Configurable AC Charger via LCD setting


Transfer Time 10ms typical
■ Compatible to mains voltage or generator power
■ Auto restart while AC is recovering Peak Efficiency 92%
■ Overload/Over temperature/short circuit protection
Nominal DC Input Voltage 48VDC
■ Smart battery charger design For optimized battery performance
■ Cold start Function Cold Start Voltage 46VDC

Output Short Line mode Circuit Breaker


Circuit
Protection Battery mode Electronic Circuits

BATTERY
Back panel description
Battery voltage 48VDC ( ±0.5)

Floating voltage 54V


1. LCD display 10. Parallel switch
CHARGER
11 10 9 8 7 6 1 5
2. Status indicator 11. AC output
3. Charging indicator 12. AC input Charging Current(UPS) @Nominal Input Voltage Default:30A; MAX:60A
4. Fault indicator 13. Dry contact
5. Function buttons 14. USB Bulk Charging Voltage 56.4Vdc
6. Power on/off switch 15. RS485 communication port
Floating Charging Voltage 54Vdc
7. Battery input 16. Circuit Breaker
15 14 13 12 4 3 2 8. Parallel communication port Charging Algorithm 3-Step
(only for parallel model)
GENERAL

Mounting Rack mount

Solar system connection Display LED+LCD

Parallel operation 3 units

Operation Temperature Range 0℃ to 40℃


TV Laptop Air-conditioning Washing machine
Storage Temperature -15℃ to 60℃
AC Input
Machine Dimension (W*H*D) 400*468*86.3mm
Utility

Package Dimension (W*H*D) /

Generator N.W /
Inverter
G.W /
BAT input

CERTIFICATION & STANDARDS

CE

64
Products / 230V

HIGH FREQUENCY POWER INVERTER


MODEL EP50-5248 PRO

EP5000 PRO Series Rated output power 5200VA/5200W

AC INPUT
5.2KW | 230V | WIFI | BAT-CAN
Nominal Input Voltage 230Vac±5%
This is a multi-function inve inverter/charger ,combining Functions of inverter,
battery charger to offfer uninte uninterruptible power with portable size. Its Selectable Voltage range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
comprehensive LCD display offers user-configurable and easy-accessible
Frequency Range 50Hz/60Hz (Auto sensing)
button operation such as battery charging current, AC charger, and acceptable
input voltage based on different applications.
Inverter Efficiency(Peak) 90%

INVERTER OUTPUT

Output voltage waveform Pure sine wave

Output Voltage Regulation 230Vac ± 5%


■ Pure sine wave inverter
Output Frequency 50Hz / 60Hz(Auto sensing)
■ Configurable input voltage range For home appliances and personal
computers via LCD setting Configurable battery charging current Power Factor ≈1
based on applications via LCD setting

■ Configurable AC Charger via LCD setting Transfer Time 10ms (UPS / VDE4105) / 20ms (APL) <50ms(For parallel operation)

■ Compatible to mains voltage or generator power Nominal DC Input Voltage 48VDC


■ Auto restart while AC is recovering
Cold Start Voltage 46VDC
■ Overload/Over temperature/short circuit protection
Output Short Line mode Circuit Breaker
■ Smart battery charger design For optimized battery performance
Circuit
■ Cold start Function Protection Battery mode Electronic Circuits
■ WIFI remote monitoring (optional)
BATTERY

Battery voltage 48VDC


Back panel description
Floating voltage 54.8V

Overcharge Protection 60V


1. LCD display 9. Parallel switch
CHARGER
11 10 14 9 8 7 6 1 5
2. Status indicator 10. AC output
3. Charging indicator 11. AC input Charging Current(UPS) @Nominal Input Voltage Default:30A; MAX:80A
4. Fault indicator 12. Dry contact
5. Function buttons 13. USB Bulk Charging Voltage 56.4Vdc
6. Power on/off switch 14. RS485 communication port
Floating Charging Voltage 54Vdc
7. Battery input 15. Circuit Breaker
15 16 17 13 12 4 3 2 8. Parallel communication port 16. ground Charging Algorithm 3-Step
(only for parallel model) 17. WiFi port (optional)
GENERAL

Mounting Rack mount

Solar system connection Display LED+LCD

Parallel operation 3 units

Operation Temperature Range -10℃ to 50℃

TV Laptop Air-conditioning Washing machine


Storage Temperature -15℃ to 60℃
AC Input
Machine Dimension (W*H*D) 400*468*86.3mm
Utility

Package Dimension (W*H*D) /

Generator N.W 11kg


Inverter
G.W /
BAT input

CERTIFICATION & STANDARDS

CE

66
Products / 230V

ON/OFF GRID HYBRID SOLAR INVERTER MODEL


PH11-3648 PH11-4048 PH11-4648 PH11-5048 PH11-6048

PH1100 PRO Series


PRO PRO PRO PRO PRO
RATED POWER 3600W 4000W 4600W 5000W 6000W
Nominal Battery System Voltage 48V
PV INPUT(DC)

3.6~6KW | Single Phase | 230VAC Maximum recommended DC power 4000W 5000W 5500W 6000W 7000W
Nominal DC operating voltage 360V
Maximum DC voltage 500V
This is a flexible and intelligent energy storage solar inverter with a wide range
MPPT voltage range 120V~500V
of MPPT Voltage.
Combining functions of off grid and on grid. This hybrid solar inverter can Maximum input current 15A / 15A
power all kinds of appliances in home or office, and can also be used in power No.of MPP tracker 2
stations. Strings per MPP tracker 1
INVERTER OUTPUT(AC)
Nominal AC output power 3600W 4000W 4600W 5000W 6000W
Nominal output voltage; range 220/230/240V;180-280V
AC grid frequency; range 50/60Hz; 45~55/55-65Hz
Nominal output current 15.6A 17.5A 20A 21.7A 26A
■ Multiple operation modes: Grid-tie,off grid with storage backup Maximum output current 16A 18.1A 20.8A 22.7A 27.2A
Inrush current (spike/duration) 57.5A/5.2us
■ IP65 water-proof and dust-proof
Total harmonic distortion i(THDi) <3%
■ MPPT voltage range 120-500V Power factor at rated power 1
■ Support LCD display&Smart LCD setting Displacement power factor 0.8leading ~ 0.8lagging
Grid type Single phase
■ Available Export control CT sensor function
BATTERY MODE OUTPUT(AC)
■ Multiple communications:USB,RS485,GPRS and wifi etc Output Rated Power 3600W 4000W 4600W 5000W 6000W
■ Full protection function:Over-voltage,over-frequency, over-current, Nominal output voltage; accuracy range 230±1%
over-temperature,and AC short-circuit automatic protection Output ferequency; accuracy range 50/60Hz (optional)±0.2%
■ Intelligent BMS battery management function Output rated current 15.6A 17.5A 20A 21.7A 26A
Output waveform Pure sine wave
■ Fanless low-noise design
Peak power 5400W,10s 6000W,10s 6900W,10s 7500W,10s 9000W,10s
■ Wifi monitoring Total harmonic distortion v (linear load) <3%
BATTERY & CHARGER
Back panel description Battery type Lead-acid battery / Lithium battery
Battery voltage 48V
Battery voltage range 40~60V
1 2 3 4 5 6 7 Charging curve 3-stage adaptive with maintenance
1. PV input terminals Protection Over-current protection / Over-temperature protection
2. Battery input terminals and cover Maximum charging power 3600W 4000W 4600W 5000W 6000W
3. Breather valve Maximum charging currernt 75A 85A 95A 100A 125A
4. PV input switch EFFICIENCY
5. BTS terminals, BMS terminals, load monitor terminals, dry contact terminals, Maximum efficiency 97.1%
CAN communication terminals, USB terminal and cover Euro-efficiency 96.5%
6. Wi-Fi commodule MPPT efficiency 99.8%
7. AC output terminals and cover PROTECTION DEVICES
DC switch rating for each MPPT; Grid monitoring; Output over current protection; Output overvoltage protection-varistor; Ground fault monitoring;
Integrated all-pole sensitive leakage current
GENERAL
Machine Dimension (W*H*D) 480*420*215mm
Solar system connection Package Dimension (W*H*D) /
G.W 27kg
N.W /
DC connection H4 / MC4
AC connection Terminal Block
Display LED+LCD
Application Communication interfaces Wi-Fi / USB / GPRS / RS485
Ingress protection rating IP65
Solar Humidity 0~95% RH(No codensing)
Operating temperature range -20℃ +60℃ With derating above 45℃
Cooling concept Natural
Altitude <3000m
CERTIFICATION & STANDARDS
Grid CE-EMC+LVD (EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011); CE-LVD(EN62477-1:2022)
IEC60529; EN50549-1:2019
Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021)
C10/C11
UNE217001-2020; UNE217002-2020, NTS-631:2021 (Type A)
Battery (optional) Generator G98+G99

68
Products / 230V

ON/OFF GRID HYBRID SOLAR INVERTER MODEL


PH1100- PH1100- PH1100- PH1100- PH1100-
5KL3-EU 6.5KL3-EU 8KL3-EU 10KL3-EU 12KL3-EU

PH1100 EU Series Rated power


BATTERY INPUT DATA
5000W 6500W 8000W 10000W 12000W

Battery type Lead-acid battery / Lithium battery

5~12KW | Three Phase | 380VAC Battery voltage 48V


Battery voltage range 40~60V
PH1100 EU is brand new three phase hybrid inverter with low battery voltage Charging curve 3-stage adaptive with maintenance/Equalization
48V, ensuring system safe and reliable. With compact design and high-power Charging Strategy for Li-lon Battery Self-adaption to BMS
density, this series supports 1.3 DC/AC ratio, saving device investment. It Over-current protection/ Over-temperature protection Yes / Yes
supports three phase unbalanced output, extending the application scenarios. Maximum charging/discharging power 5000W 6500W 8000W 10000W 12000W
Equipped with CAN port (x2) BMS and parallel, x1 RS485 port for BMS, x1
Maximum charging/discharging current 120A 150A 190A 210A 240A
RS232 port for remotely control, x1 DRM port, which makes the system smart
and flexible. PV STRING INPUT DATA
Max. DC Input Power 6500W 8450W 10400W 13000W 15600W
Rated PV Input Voltage 550V
Maximum DC voltage 800V
Start-up Voltage 160V
Minimum voltage for grid connection 310V
■ 100% unbalanced output, each phase max. output up to 50% rated power Full Load DC Voltage Range 350-650V
Enter high voltage error recovery point 800V
■ Max. 6 pcs parallel for on-grid and off-grid operation
MPPT voltage range 200~650V
■ AC couple to retrofifit existing solar system
Maximum input current 15A/15A 26A/13A
■ Support multiple batteries parallel No.of MPP Trackers 2
■ Max. charging/discharging current of 240A No.of Strings per MPP Tracker 1+1 2+1
■ Support storing energy from diesel generator AC OUTPUT DATA
Rated AC Output Power 5000W 6500W 8000W 10000W 12000W
■ 48V low voltage battery, transformer isolation design
Max AC Output Power 5500W 7150W 8800W 11000W 13200W
■ IP65 water-proof and dust-proof
AC Output Rated Current 7.6/7.2A 9.8/9.42A 12.1/11.6A 15.2/14.5A 18.2/17.4A
■ "Time of use" function: a maximum of 6 time segments can be set Max AC Output Current 8.4/8A 10.8/10.4A 13.4/12.8A 16.7/15.9A 20/19.1A
■ Wifi monitoring Max. Three-phase Unbalanced Output Current 11.4/10.9A 14.7/14.1A 18.2/17.4A 22.7/21.7A 27.3/26.1A
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage 220/380,230/400Vac

Back panel description Rated Input/Output Grid Frequency/Range 50/60;45~55/55-65


Grid Type Three Phase
Total Harmonics Current Distortion (THDi) <3% (of nominal power)
1 2 3 4 5 6 7 8 9 1. DC switch DC Current Injection <0.5% In
2. Battery input connectors EFFICIENCY
3. BTS terminals, BMS terminals, load monitor terminals, dry contact terminals, Max. Efficiency ≥97.5%
CAN communication terminals, USB terminal and cover
Euro Efficiency 97.0%
4. Circuit breaker of Grid
PROTECTION
5. Load
6. Generator input PV Arc Fault Detection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Integrated Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
7. WiFi Interface Output Shorted Protection
8. Ground
Surge Protection DC Type III/AC Type III
9. PV input with two MPPT
Overvoltage Category DC Type II/AC Type III
GENERAL DATA
Solar system connection Operating Temperature Range (°C) -20°C to +60°C, >45°C Derating
Cooling Smart cooling
Basic With Generator Noise (dB) ≤55dB
Communication with BMS Wi-Fi/USB/GPRS/RS485/CAN
Weight (kg) 35kg
Cabinet Size (WxHxD mm) 444*654.2*259.2mm
Protection Degree IP65
Solar Backup Load On-Grid Home Load Solar Backup Load On-Grid Home Load
Installation Style Wall-mounted
5 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

CERTIFICATION & STANDARDS


Grid Grid
CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC 62109-1, EN IEC 62109-2); CE-LVD(EN 62477-1) ;
IEC 60529; EN50549-1;
Battery Battery Generator Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021)
C10/C11; UNE217001-2020; UNE217002-2020, NTS-631 (Type A); G98+G99

70
Products / 230V

MODEL PH16-4048 PRO PH16-5048 PRO PH16-6048 PRO


AC-COUPLED ENERGY STORAGE INVERTER RATED POWER 4000W 5000W 6000W

PH1600 PRO Series


Nominal Battery System Voltage 48V
INVERTER OUTPUT(AC)
Nominal AC output power 4000W 5000W 6000W

4~6KW | Single Phase | 230VAC


Nominal output voltage range 220/230/240V;180-280V ±5VAC
AC grid frequency range 50/60Hz; 45~55/55-65Hz

The PH1600 PRO Series is designed for retrofitting PV systems, including power Nominal output current 17.5A 21.7A 26A
classes ranging from 4kw to 6kw. It can be installed with existing PV inverters, Maximum output current 18.1A 22.7A 27.2A
forming an AC coupling system. Inrush current (spike/duration) 57.5A/5.2us
Capable of being grid-interactive, it allows users to store surplus power and
sell it back to the grid when demand peaks and the price of electricity is at its Total harmonic distortion i(THDi) @Nominal Output <3%
highest. It runs reliably under even the most extreme conditions with metal Power factor at rated power ≈1
aluminium housing with IP66 protection. Displacement power factor Adjustable from 0. 8 leading to 0. 8 lagging
Grid type Single phase
BATTERY MODE OUTPUT(AC)
Output Rated Power 4000W 5000W 6000W
Nominal output voltage; accuracy range 230±1%
■ LCD+LED – user friendly interface
Output ferequency; accuracy range 50/60Hz (optional)±0.2%
■ IP66 design for outdoor
Output rated current 17.5A 23A 26A
■ Compatible with other brands of inverter
Output waveform Pure sine wave
■ Various work mode for different application scenarios Peak power 6000W/10S 7500W/10S 9000W/10S
■ Natural cooling without external fan Total harmonic distortion v (linear load) <3%
■ BMS Function BATTERY & CHARGER
■ Wifi monitoring Battery type Lead-acid battery / Lithium battery

■ UPS level switching time <10 ms Battery voltage 48V ±0.3


Battery voltage range 40~60V ±0.3
■ Retrofit any on-grid systems to be able to run battery
Charging curve 3-stage adaptive with maintenance
Protection Over-current protection / Over-temperature protection

Back panel description Maximum charging power 4000W 5000W 6000W


Maximum charging currernt 85A 105A 125A
EFFICIENCY
1 2 3 4 5
Battery discharge (full load) 94.5%
Maximum battery charging current efficiency 94.5%
1. Battery input terminals and cover PROTECTION DEVICES
2. Breather valve
Grid monitoring Yes
3. BTS terminals, BMS terminals, load monitor terminals, dry contact terminals,
CAN communication terminals, USB terminal and cover Output over current protection Yes

4. Wi-Fi commodule Output overvoltage protection-varistor Yes


5. AC output terminals and cover Ground fault monitoring Yes
Integrated all-pole sensitive leakage current Yes
GENERAL
Machine Dimension (W*H*D) 410*420*215mm
Solar system connection Package Dimension (W*H*D) /
N.W 25kg
G.W /
AC connection Terminal Block
Display LED+LCD
Communication interfaces Wi-Fi/USB/GPRS/RS485/CAN
Ingress protection rating IP66
Humidity 0~95% RH(No codensing)
Operating temperature range -20℃ +60℃ With derating above 45℃
Cooling concept Natural
Noise figure [dB] ≤25
Altitude <3000m
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN IEC61000-6-3: 2007, ENIEC61000-6-1:2017; EN IEC62477-1:2022)

72
Products / 230V

ON GRID SOLAR INVERTER PH59- PH59- PH59- PH59- PH59- PH59-


MODEL

PH5900 Series
3000M 3600M 4200M 4600M 5000M 6000M
RATED POWER 3000W 3600W 4200W 4600W 5000W 6000W
PV INPUT(DC)
Maximum recommended DC power 3900W 4700W 5460W 5980W 6500W 7800W
3~6KW | Single Phase | 230VAC Nominal DC operating voltage 360V
Maximum DC voltage 550V
PH5900 series PV inverters take full account of the needs of end customers,
Start voltage 50V
with excellent performance at the same time, use LED as inverter status display,
effectively improve product life. Using DSP digital control,could afford wide MPPT voltage range 40~550V
grid voltage range, have a full range of protection features; to maximize the Maximum input current 16A/16A
benefits at the same time, greatly enhance the reliability of the product. No.of MPP tracker/ strings per MPP tracker 2/1
DC connection H4/MC4
GRID OUTPUT(AC)
Nominal AC output power 3000W 3600W 4200W 4600W 5000W 6000W
Max. AC output power 3000VA 3600VA 4200VA 4600VA 5000VA 6000VA
AC grid frequency 50/60Hz ±5Hz
■ High Frequency On Grid Solar Inverter Maximum output current 13.6A 16A 19A 20.9A 22.7A 27.2A
■ Rate power: 3-6KW AC nominal voltage 220V/230V/240V
AC voltage range 180-280V
■ MPPT efficiency up to 99.50%
Total harmonic distortion (THDi) <3%
■ Multiple communications: WIFI etc
Rate power factor 1
■ Monitoring inverters freely via mobile phonese APP Power factor adjustable range 0.8 leading ~ 0.8 lagging
■ Fanless low-noise design AC grid connection type L+N+PE

■ IP66 water-proof and dust-proof EFFICIENCY


Maximum efficiency 98.0% 98.0% 98.1% 98.1% 98.2% 98.2%
Euro-efficiency 96.8% 96.8% 97.0% 97.0% 97.2% 97.2%
MPPT efficiency 99.5%
Self-Consumption night <1W
PROTECTION DEVICES
Output over current protection Yes
Back panel description
Output AC overvoltage protection Yes
DC reverse polarity protection Yes
DC switch Yes
Ground fault monitoring Yes
1 2 3 4 5 6 7 8 1. DC switch Integrated all-pole sensitive leakage current monitoring unit Yes
2. PV1 input PHYSICAL
3. PV2 input Machine Dimension (W*H*D) 402*378*195mm
4. WIFI connector G.W 11kg
5. CT/Meter port INTERFACE
6. RS-485 connector DC connection H4/MC4
7. AC output AC connection Connector
8. Ground
Display LED
Communication interfaces WIFI/RS485/GPRS(opt)
ENVIRONMENT
Ingress protection rating IP66
Solar system connection Humidity 0-100%
Operating temperature range -25℃ ~+60℃ With derating above 45℃

Basic Cooling concept Natural


Noise emission(typical)[dB] ≤35dB(A)
Self-consumption night <1W
Topology Transformerless
Altitude 4000m
Solar On-Grid Home Load OTHERS
Topology transformerless
Warranty Standard 5years/10 years(opt.)
CERTIFICATION & STANDARDS
CT
(optional) CE-EMC+LVD(EN6100-6-3, 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
IEC60529; EN50549-1:2019; RD1699, UNE206006:2011, UNE206007:2013
Poland Type A (NC RfG:2016, PSE:2018, PTPiREE:2021)
Grid G98, G99

74
Products / 230V

ON GRID SOLAR INVERTER PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59-

PH5900 TM Series
MODEL 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 15000
TM TM TM TM TM TM TM TM TM TM TM
Rated AC output power 4000W 5000W 6000W 7000W 8000W 9000W 10000W 11000W 12000W 13000W 15000W

OUTPUT (AC)
4~15KW | Three-phase | 380VAC
Max.AC apparent power 4400VA 5500VA 6600VA 7700VA 8800VA 9900VA 11000VA 12100VA 13200VA 14300VA 16500VA
PH5900TM series PV inverters take full account of the needs of end customers, Max.output current 6.4A 8A 9.6A 11.1A 12.7A 14.3A 15.9A 17.5A 19A 20.6A 23.8A
It is used to convert the DC generated by photovoltaic panels into AC and send
Nominal AC Voltage 230V / 400V
it to the grid in a three-phase manner.with excellent performance at the same
time, use LED as inverter status display, effectively improve product life. Using AC Voltage range 320-478V
DSP digital control,could afford wide grid voltage range, have a full range of
AC grid frequency range 50/60Hz ±5Hz
protection features; to maximize the benefits at the same time, greatly enhance
the reliability of the product. Power factor at Rated power 1

Adjustable displacement power factor 0.8leading...0.8lagging

Total harmonic distortion (THDi) < 3%

AC grid connection type 3W+N+PE

INPUT DATA
■ Wide MPPT voltage range from 200V-1000V
Max.recommended PV power 4800W 6000W 7200W 8400W 9600W 10800W 12000W 13200W 14400W 15600W 18000W
■ IP66 protection degree
Max.DC voltage 1000V
■ Integrated DC switch
Start voltage 160V
■ DSP controller
Nominal voltage 600V
■ The maximum efficiency is 98.4%
MPPT voltage range 200V-1000V
■ Multi MPPT controller
12.5A/ 12.5A/ 12.5A/ 12.5A/ 12.5A/ 12.5A/ 12.5A/ 12.5A/ 21A/ 21A/ 21A/
■ WIFI monitoring standard Max.input current
12.5A 12.5A 12.5A 12.5A 12.5A 12.5A 12.5A 12.5A 11A 11A 11A
■ Easy installation Number of independent MPP trackers
2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/2+1 2/2+1 2/2+1
/ strings per MPP tracker

DC connection H4 / MC4

EFFICIENCY
Back panel description Max.efficiency 98.4%

Euro weighted efficiency 97.6% 97.6% 97.6% 98% 98% 98% 98% 98% 98% 98% 98%

MPPT efficiency 99.5%

1 2 3 4 5 6 7 8 9
1. PV1 input Island protection, DC reverse polarity protection , Output over current protection,
Protection devices Output overvoltage protection-varistor, Integrated DC switch, Ground fault monitoring,
2. PV2 input
Integrated all-pole sensitive leakage current monitoring unit
3. DC switch
GENERAL DATA FEATURES
4. Ground
5. WIFI connector Dimension(W/H/D)(mm) 539.7*426.2*216.9mm
6. USB port Weight (kg) 21 23.2 24.8
7. RS-485 connector
Operation temperature range -25℃ - +60℃ with derating above 45℃
8. Meter port
9. AC output Noise emission(typical) ≤35dB(A)

Altitude 3000m

Self-consumption (night) < 1W


Solar system connection Topology Transformerless

Cooling concept Natural


Basic
Environmental protection Rating IP66

Relative humidity 0~100%

FEATURES

Solar On-Grid Home Load AC connection Connector

Display LED

Communication interfaces USB/WIFI/RS485/GPRS(opt)


CT Warranty Standard 5 years / 10 years (opt.)
(optional)
CERTIFICATION & STANDARDS
Grid CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
IEC60529; EN50549-1:2019; UNE217001-2020; UNE217002-2020, NTS-631:2021 (Type A);
Meter (optional) G99

76
Products / 230V

ON GRID SOLAR INVERTER PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59-

PH5900 TM Series
MODEL 17000 18000 19000 20000 21000 22000 23000 24000 25000
TM TM TM TM TM TM TM TM TM
Rated AC output power 17000W 18000W 19000W 20000W 21000W 22000W 23000W 24000W 25000W

17~25KW | Three-phase | 380VAC


OUTPUT (AC)

Max.AC apparent power 18700VA 19800VA 20900VA 22000VA 23100VA 24200VA 25300VA 26400VA 27500VA
PH5900TM series PV inverters take full account of the needs of end customers, Max.output current 27.1A 28.6 30.2 31.8A 33.5A 35A 36.6A 38A 39A
It is used to convert the DC generated by photovoltaic panels into AC and send
it to the grid in a three-phase manner.with excellent performance at the same Nominal AC Voltage 230V/400V
time, use LED as inverter status display, effectively improve product life. Using AC Voltage range 320-478V
DSP digital control,could afford wide grid voltage range, have a full range of
protection features; to maximize the benefits at the same time, greatly enhance AC grid frequency range 50/60±5Hz
the reliability of the product. Power factor at Rated power 1

Adjustable displacement power factor 0.8leading...0.8lagging

Total harmonic distortion (THDi) < 3%

AC grid connection type 3W+N+PE

INPUT DATA
■ Wide MPPT voltage range from 200V-1000V
Max.recommended PV power 25500W 27000W 28500W 30000W 31500W 33000W 34500W 36000W 37500W
■ IP66 protection degree

■ Integrated DC switch Max.DC voltage 1100V

■ DSP controller Start voltage 250V

■ The maximum efficiency is 98.6% Nominal voltage 600V

■ Multi MPPT controller MPPT voltage range 200V-1000V

■ WIFI monitoring standard Max.input current 26A/26A 26A/26A 26A/26A 26A/26A 26A/39A 26A/39A 26A/39A 26A/39A 26A/39A

■ Easy installation Number of independent MPP trackers


2/2 2/2 2/2 2/2 2/2+3 2/2+3 2/2+3 2/2+3 2/2+3
/ strings per MPP tracker

DC connection H4 / MC4

EFFICIENCY

Back panel description Max.efficiency 98.6%

Euro weighted efficiency 98.3% 98.3% 98.3% 98.3% 98.3% 98.3% 98.3% 98.3% 98.3%

MPPT efficiency 99.5%

Island protection, DC reverse polarity protection , Output over current protection,


1. DC switch
1 2 3 4 5 6 7 8 Protection devices Output overvoltage protection-varistor, Integrated DC switch, Ground fault monitoring,
2. PV1 input Integrated all-pole sensitive leakage current monitoring unit, DC Surge protection, AC Surge protection
3. PV2 input
GENERAL DATA FEATURES
4. Ground
5. RS-485 connector Dimension(W/H/D) 539.7*426.2*232.2mm

6. CT/Meter port Weight 24kg


7. WIFI connector Operation temperature range -25℃ - +60℃ with derating above 45℃
8. AC output
Noise emission(typical) ≤40dB(A)

Altitude 3000m

Self-consumption (night) < 1W

Solar system connection Topology Transformerless

Cooling concept Fan cooling


Basic
Environmental protection Rating IP66

Relative humidity 0~100%

FEATURES

AC connection Connector
Solar On-Grid Home Load
Display LED

Communication interfaces WIFI/RS485/GPRS(opt)

Warranty Standard 5 years / 10 years (opt.)


CT
(optional) CERTIFICATION & STANDARDS

CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)


Grid IEC60529; EN50549-1:2019; UNE217001-2020; UNE217002-2020, NTS-631:2021 (Type A);
G99

78
Products / 230V

ON/OFF HYBRID SOLAR INVERTER


MODEL PH18-8048 PRO PH18-10048 PRO

PH1800 PRO Series Nominal Battery System Voltage 48VDC

INVERTER OUTPUT
8~10KW | Three-phase | 380VAC
Rated Power 8000W 10000W
This is a multi-function inverter/charger, combining functions of inverter,
Surge Power 16000W 20000W
solar charger and battery charger to offer uninterruptible power support with
portable size. Its comprehensive LCD display offers user-configurable and easy-
Waveform Pure Sine Wave
accessible button operation such as battery charging current, AC/solar charger
priority, and acceptable input voltage based on different applications.
AC Voltage Regulation (Batt.Mode) 230VAC±5%

Output Frequency 60Hz or 50Hz

Inverter Efficiency(Peak) 90%


■ Pure sine wave inverter
Transfer Time 10ms (UPS) 20ms (APL)
■ Configurable input voltage range for home appliances and personal
computers via LCD setting
AC INPUT
■ Configurable battery charging current based on applications via LCD setting
■ Configurable AC/Solar Charger priority via LCD setting Nominal Input Voltage 230VAC
■ Compatible to mains voltage or generator power
Max AC Input Voltage 300VAC
■ Auto restart while AC is recovering
■ Overload/ Over temperature/ short circuit protection Selectable Voltage Range 170~280VAC (UPS) / 90~280VAC (APL) / 184~253VAC(VDE4105)
■ CAN/RS485 communication for BMS
Frequency Range 50Hz / 60Hz(Auto detection)
■ Cold start function
■ WiFi remote monitoring (optional) BATTERY

Normal Voltage 48VDC

Back panel description SOLAR CHARGER & AC CHARGER

AC Charging Current 2-120A 2-160A


1. Ground
1 2 1 3 4 5 6 7 8 9 10 11 12 13
2. AC Input Maximum PV Array Open Circuit Voltage 450VDC
3. AC Output
4. AC input breaker PV Array Open Circuit Voltage 150-430VDC
5. PV input
Cold Start Voltage 46VDC
6. COM2
7. BMS communication
Solar Charging Current 80A/80A 100A/100A
14
8. Battery input
9. Power on/off switch Default Charging Current 80A/80A
10. PV input
11. COM1 Maximum Charge Current 160A 200A

12. USB
Charging Algorithm 3-step (Flooded Battery / AGM / GEL/ LEAD Battery), 4-step(LI)
13. Dry contact
14. WiFi port GENERAL DATA FEATURES

Operating Temperature -10°C~50°C


Solar system connection
Storage Temperature -15°C ~60°C

PV1 input Machine Dimension (W*H*D) 600*503*141.2mm


Solar Panel
Package Dimension (W*H*D) /
TV Fridge Lighting Fans
PV2 input
G.W (kg) 21kg
Solar Panel

N.W (kg) /
AC Input

CERTIFICATION & STANDARDS


Utility
BAT input EN IEC62368-1
CE-LVD (EN IEC62109-1, EN IEC62109-2)
Inverter Rohs-(2011/65/EUand2015/863/EU)
Generator CE-LVD (BS IEC62109-1:2010, BS EN IEC62109-2:2011)
Battery UKCA

80
Products / 230V

ON/OFF GRID HYBRID SOLAR INVERTER MODEL PH18-3024 PRO PH18-5248 PRO

PH1800 PRO Series Nominal Battery System Voltage 24VDC 48VDC

INVERTER OUTPUT

3~5.2KW | 450V | WiFi Rated Power 3000VA / 3000W 5200VA / 5200W

PH1800 PRO is a multi-function inverter/charger, combining functions of Surge Power 6000W 10400W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PH1800 PRO Series can run without battery. The Waveform Pure sine wave
Maximum PV array open circuit voltage can reach 450V and MPPT voltage
is 150~430V, which can help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)

Inverter Efficiency(Peak) 90%

Transfer Time 10ms (UPS / VDE4105) / 20ms (APL)

■ Pure sine wave output AC INPUT

■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
Voltage 230VAC±5%
■ Built-in MPPT solar charge controller
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
■ MAX PV Array Open Circuit Voltage: 450V

■ Combining solar system, AC utility, and battery power source to supply Frequency Range 50Hz / 60Hz(Auto sensing)
continuous power
BATTERY
■ Overload, short circuit and Deep discharge protection

■ Cold start function Normal voltage 24VDC 48VDC

■ Support USB, RS485 monitoring function Floating Charge Voltage 27.4VDC 54.8VDC
■ Parallel operation with up to 3 units
Overcharge Protection 30VDC 60VDC
■ WIFI remote monitoring (optional)
SOLAR CHARGER & AC CHARGER

Back panel description Maximum PV Array Open Circuit Voltage 450VDC

3KW Maximum PV input voltage 18A 18A 27A

1 2 3 7 8 9 10 11 12 1. AC Input Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
2. AC Output
Maximum PV Array Power 4000W 5000W 6000W
3. PV Input
4. Power On/Off Switch PV Array MPPT Voltage Range 150~430 VDC
6 5 4 5. Battery Input
6. Circuit breaker Maximum Solar Charge Current 80A 100A 80A 100A

7. Dry Contact
5KW Maximum AC Charge Current 60A 80A 60A 80A
1 2 9 8 7 3 4 12 8. USB port
9. RS-485/CAN Communication port Maximum Charge Current 80A 100A 80A 100A
10. Parallel switch (only for parallel model)
MECHANICAL SPECIFICATIONS
11. Parallel communication port
(only for parallel model)
Machine Dimension (W*H*D) 322*486*134mm 309*505*147mm
12. USB WiFi port
6 10 11 5
Package Dimension (W*H*D) 575*229*425mm 603*260*400mm

Solar system connection )N.W (kg) 10.6kg 12.9kg

G.W (kg 12kg 13.8kg

OTHER
PV input
TV Fridge Lighting Fans
Humidity 5% to 95% Relative humidity (Non-condensing)
Solar Panel

Operating Temperature 0°C~50°C


AC Input
Storage Temperature -15℃ ~60℃

Utility
CERTIFICATION & STANDARDS
BAT input
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2020+A11:2020
EN IEC62368-1:2018
Inverter
Generator Battery Rohs-(2011/65/EUand2015/863/EU)

82
Products / 230V

ON/OFF GRID HYBRID SOLAR INVERTER MODEL PH30-10048-T PH30-12048-T

PH3000 Series Nominal Battery System Voltage 48VDC

INVERTER OUTPUT

Rated output power 10000W 12000W


10~12KW | Three-phase | 380VAC | Low Frequency
Output wave Pure sine wave
This model PH3000 Three-phase is a flexible and intelligent energy storage Nominal output voltage 230 VAC (P-N) / 400 VAC (P-P)
inverter which utilizes solar power, utility power, and battery power source to
supply continuous power. This is a multi-functional hybrid inverter which can Nominal output current 14.3A per phase 17.4A per phase
power all kinds of appliances in home or office environment, including motor-
type appliances such as tube light, fan, refrigerator and air conditioner. Nominal output frequency 50 Hz / 60 Hz
The system generates electricity when it has sufficient sunshine, supplying Rate of wave distortion(THD)(Linearity loads) Off grid≤2%; Grid discharge ≤3%; Grid charge ≤3%
power to your home and feeding any surplus power back to the Grid.
Peak efficiency ≥93%

100%<load≤110%,30 minutes; 110%<load≤125%,1 minutes;


Overload capability
125%<load≤150%,30 seconds; load<150%,10 seconds; Short circuit,5 seconds

■ Rated power 10KW to 12KW AC INPUT

■ Smart LCD setting(Working modes, Charge Current, Charge Voltage, etc.) AC input maximum current 26.0A per phase 34.8A per phase
■ Built-in MPPT 180A solar charge controller Nominal frequency 50Hz / 60Hz
■ MPPT Efficiency max 98%
Defaults 186Vac ~253Vac per phase;Narrow 174Vac ~272Vac per phase;
■ Combining solar system, AC utility, and battery power source to supply Acceptable input voltage range
Wide 95Vac ~272Vac per phase
continuous power
■ Multiple operations: basic Grid-tie, Off-Grid, Grid-Interactive BATTERY

■ Support CAN, RS485 monitoring function Type of Battery Lithium battery or lead-acid battery

Nominal Voltage 48VDC

Low Voltage Protection Point Charger 34.0VDC; Inverter 40.0VDC


Back panel description
Absorption Voltage 50.0VDC

Refloat Voltage 54.8VDC


1 2 3 4 5 8
7 Float Voltage 57.2VDC
6
SOLAR CHARGER & AC CHARGER
1. LCD Display 9. Battery input
PV Open Circuit Voltage 145VDC
2. Status Indicator 10. AC output breaker
3. Charging Indicator 11. Grid breaker Max Solar Charging Current 60A per channel
4. Fault Indicator 12. Grounding
9 Max AC Charging Current 60A per phase 80A per phase
10
5. Function Buttons 13. Grid
11
6. USB commnuication port 14. Grounding Max Charging Current 120A per phase 140A per phase
7. CAN/RS485 communication 15. AC output MECHANICAL SPECIFICATIONS
8. BTS 16. PV input
Mounting Vertical
16 Machine Dimension (W*H*D) 392*828*629mm
15 12
14 13 Package Dimension (W*H*D) 513*1031*700mm

G.W 133kg 140kg

Solar system connection N.W 128kg 160kg

OTHER

Communication terminal RS485 / CAN bus

PV input Operation Temperature Range 0℃ ~ +50℃


TV Fridge Lighting Fans

Solar Panel
Environmental Protection Rating IP20

Ambient humidity 0 -- 90% relative humidity (non-condensing)


AC Input
Altitude ≤2000m

Utility CERTIFICATION & STANDARDS


BAT input
EN IEC62368-1
CE-LVD (EN IEC62109-1, EN IEC62109-2)
Rohs-(2011/65/EUand2015/863/EU)
Inverter CE-LVD (BS IEC62109-1:2010, BS EN IEC62109-2:2011)
Generator Battery
UKCA

84
Products / 230V

PURE SINE WAVE INVERTER PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15-
MODEL

PI1500 Series
0312 0324 0612 0624 1012 1024 1512 1524 2012 2024

BATTERY DC INPUT

Input Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC
300~2000W | 12V,24V | 230V Low Voltage Protect Delay 2 seconds

PI1500 series is a pure sine wave inverter, high frequency machine solution, the (PB) 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC
Low Voltage Warning
product is small size, the solution is reliable and stable, the main function is to (LI) 10.5VDC 21.0VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC
invert the DC 12VDC battery or 24VDC battery to AC 230VAC output, mainly
used for emergency use Electricity, car inverter, outdoor electricity and other (PB) 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC
Low Voltage Protect
occasions. (LI) 11.5VDC 23.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC

(PB) 12.5VDC 25.0VDC 12.5VDC 25.0VDC 12.5VDC 25.0VDC 12.5VDC 23.0VDC 12.5VDC 23.0VDC
Low Voltage Restoring
(LI) 12.5VDC 25.0VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC

(PB) 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC
Over Voltage Protect
■ Input Voltage 12V / 24V DC optional (LI) 14.7VDC 29.4VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC

■ Output Voltage 230V AC optional (PB) 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC
Over Voltage Restoring
■ Portable power for AC products, AC outlets for connecting multiple loads (LI) 15.0VDC 30.0VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC
■ High efficiency converts virtually all of the battery's power to AC Parameters: (PB) Lead-acid Battery / (Ll) 4 series (12V), 8 series (24V) LiFePO4 Lithium Battery Pack
■ Mounting brackets for convenient installation
INVERTER AC OUTPUT
■ Overload and over temperature shut down
Default Power 300W 600W 1000W 1500W 2000W
■ Low voltage and over voltage alarm/cut off
Peak Power 600W 1200W 2000W 3000W 4000W
■ Short circuit protection
Output AC Voltage 230V 230V 230V 230V 230V

Output AC Frequency 50Hz 50Hz 50Hz 50Hz 50Hz

Output Wave Pure Sine Wave

Output Wave THD < 3%


Solar system connection PROTECTION

Battery Input Protection Low Voltage Protection, Over Voltage Protection, Reverse Protection

Inverter Output Protection Output Overload, Short-Circuit, Over Temperature Protection


PV input BAT input
DISPLAY

PV Battery LED Display Red: Error ; Green: System OK

MPPT Solar Chage LED Digital Display / Display Battery Voltage, Output Power, Output Voltage, Error Numbers
Controller
Inverter DC OUTPUT

USB USB-A type (5V1A)

12V/24V EFFICIENCY
Car cigarette lighter
(Load must lower 120W; Available for 300W only) Peak Conversion efficiency 91% 91% 90% 88% 90% 88% 90%

ENVIRONMENT
Laptop Lighting TV Fans

Protection Degree IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20

Working Environment Indoor Fan cooling

Environmental temperature 0~45°C


Type
Ambient humidity 20%--90%, No condensation

Altitude ≤3000m

DIMENSIONS

Machine Dimension (W*H*D) 205*125*61mm 242*158*81mm 291*220*83mm 380.8*248*90 mm

Package Dimension (W*H*D) 228*176*102mm 268*205*140mm 330*267*147mm 420*300*150mm

N.W (kg) 1kg 1.7kg 2.6kg 4.5kg

G.W (kg) 9.3kg (8pcs) 15kg (8pcs) 23kg (8pcs) 19kg (4pcs)

CERTIFICATION & STANDARDS


CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2)
CE-LVD(EN 62477-1/A11)

86
120V Series
Off Grid Solar Inverter/ On/Off Grid Hybrid Solar Inverter/ Grid-Tie Solar Inverter/ Off Grid Power Inverter

88
Products / 120V

SOLAR INVERTER MODEL PV15-1512 LV PV15-1524 LV

PV1500 LV Series Nominal Battery System Voltage


NVERTER OUTPUT
12VDC 24VDC

Rated Power 1500VA/ 1000W


1KW | 120V | 100VDC Waveform Pure Sine Wave
Nominal Output Voltage RMS 120V
It is a cost efective, inteligent solar inverter which accepts Solar & Utility input
at the same fime. The comprehensive lCD display ofers user-conigurable and Output Voltage Regulation +10/-18%
easy-accessible buton adjustment such as batery charging curent, AC/solar Output Frequency 50Hz / 60Hz ± 1Hz
charger priority and DC priority,.When battery voltage islow,it will automatically
Inverter Efficiency (Peak) >90%
switch to AC grid to supply continuous power to the loads.
Line Mode Efficiency >95%
Typical Transfer Time Typical < 10ms , 15ms max

■ Built-in 40A MPPT Solar Charge Controller AC INPUT

■ 10A or 15A standard charging current from utility AC Voltage 120VAC

■ 2 Output ports for DC load Voltage Range 88 ~ 144VAC ± 3%


Frequency Range 45 ~ 65Hz ± 2Hz
■ AC/solar priority for charging via MFD
BATTERY
■ Different charging mode for different kinds of batteries
Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack - 12V(4 Series) 24V(8 Series)
■ Overload & short-circuit protection, Battery reverse polarity protection,
Deep discharge protection Nominal Input Voltage 12VDC 24VDC
■ Auto restart while AC/solar is recovering Adjustable solar and utilitycharging current Low Battery Cutoff 10.5VDC(PB) 11.5VDC(LI) 21.0VDC(PB) 23.0VDC(LI)

■ Support fast max charging current setting Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)

■ Support two kinds of batteries: LiFePO4 Lithium Battery Packand Lead-acid Battery Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)

■ Automatic activate lithium battery pack which is be over discharged no High Battery Voltage Recover 14.5VDC(PB) 14.3VDC(LI) 29.0VDC(PB) 28.6VDC(LI)
output when AC input is OK
High Battery Voltage Cutoff 15.0VDC(PB) 14.8VDC(LI) 30.0VDC(PB) 29.6VDC(LI)
SOLAR CHARGER & AC CHARGER
Back panel description Charger Voltage boost 14.4VDC(PB) 14.4VDC(LI) 28.8VDC(PB) 28.8VDC(LI)
Charger Voltage float 13.8VDC(PB) 14.4VDC(LI) 27.6VDC(PB) 28.8VDC(LI)
Maximum PV Charge Current 40A (max)
Maximum PV Array Power 600W 1200W
1. DC Input MPPT Operating Voltage Range 14 ~ 75VDC 28 ~ 75VDC
1 2 3 4 5 6 7 8 2. Solar panel terminal
Maximum PV Array Open Voltage 100VDC
3. ON/OFF
4. USB-A WIFI communication Maximum Efficiency > 95%

5. USB-B PC communication Standby Power Consumption < 2W


6. RJ11 BMS Li battery Pack communication (optional AC Charging Current 20A (Can be set)
7. AC Input
Maximum Charge Current AC+PV 60A (Can be set)
8. Output Socket (s)
BYPASS & PROTECTION
Overload Protection (SMPS Load) FUSE
Output Short Circuit Protection FUSE
Bypass Fuse Rating 15A
Max Bypass Current 15A
Battery Fuse Current 50A x 3 50A x 2
Solar system connection
OTHER
Operation Temperature Range 0℃ to 40℃
Audible Noise 50dB MAX
TV Laptop Lighting Fans
PV input
Display LED+LCD
DIMENSIONS
Solar Panel
Machine Dimension (W*H*D) 320*267*96mm
AC Input Package Dimension (W*H*D) /
BAT input
N.W 4.5kg
Utility Battery G.W /

Inverter
CERTIFICATION & STANDARDS
///////////////////

90
Products / 120V

HIGH FREQUENCY OFF GRID SOLAR INVERTER PV18-1012 PV18-1512 PV18-1524 PV18-2024 PV18-3024 PV18-3048
MODEL

PV1800 LV Series
LV LV LV LV LV LV

Nominal Battery System Voltage 12VDC 12VDC 24VDC 24VDC 24VDC 48VDC

INVERTER OUTPUT
1~3KW | 120V | Wifi
Rated Power 1000W 1500W 1500W 2000W 3000W 3000W
PV1800 LV Series is a multi-function inverter/charger, combining functions
of inverter, MPPT solar charger and battery charger to offer uninterruptible Surge Power 1000W 1500W 1500W 4000W 6000W 6000W
power support with portable size. Its comprehensive LCD display offers user-
configurable and easy-accessible button operation such as battery charging Waveform Pure sine wave
current, AC/solar charger priority, and acceptable input voltage based on
different applications. AC Voltage Regulation (Batt.Mode) 120VAC ±5%

Inverter Efficiency(Peak) 90%~93%

Transfer Time 10ms (UPS / UL) 20ms (APL)

■ Pure sine wave solar inverter AC INPUT


■ Output power factor 1
Voltage 120VAC
■ Built-in 80A MPPT solar charger

■ 2 units can be wired in parallel to create a split-phase system Selectable Voltage Range 107~132VAC(UL)
with 120V and 240V capabilities (only for 3kw)
Frequency Range 50Hz / 60Hz(Auto sensing)
■ Support parallel operation up to 3 units (only for 3kw)

■ WIFI remote monitoring (optional) BATTERY

■ CAN/RS485 communication for BMS


Normal voltage 12VDC 12VDC 24VDC 24VDC 24VDC 48VDC
■ Compatible to generator
Floating Charge Voltage 13.7VDC 13.7VDC 27.4VDC 27.4VDC 27.4VDC 54.8VDC

Overcharge Protection 15VDC 15VDC 30VDC 30VDC 30VDC 60VDC


Back panel description
SOLAR CHARGER & AC CHARGER

Max. PV Array Open


105V 145V 160V 160V 450VDC 250VDC
6 7 8 9 11 10
1. AC input Circuit Voltage
2. AC output
Max. Solar Charge Current 60A 60A 60A 60A 100A 80A
3. Circuit breaker
4. Battery input
PV Array MPPT Voltage Range 15~105VDC 15~130VDC 30~128VDC 30~128VDC 90-430VDC 60-200VDC
5. PV input
6. Power on/off switch PV Input Power 750W 750W 1500W 1500W 4000W 4000W
7. RS-485 Communication port
12 13 14 16 17 15
8. USB Maximum Efficiency 98%

9. Dry contact
Maximum AC Charge Current 10A 10A 30A 40A 80A 60A
10. USB wifi
11. Parallel switch (only for parallel model) Maximum Charge Current 70A 70A 90A 100A 100A 140A
12. Parallel communication port (only for parallel model)
MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 224*321*95mm 255*321*125mm 254.5*367.4*103mm 329*485*134mm

Package Dimension (W*H*D) 410*188*300mm 416*216*342mm 436*189*331mm 575*425*229


Solar system connection
N.W 5.0kg 5.5kg 5.4kg 5.5kg 8kg 10kg

G.W 6.0kg 6.5kg 6.4kg 6.5kg 9.5kg 11.5kg


PV input
TV Fridge Lighting Fans
OTHER
Solar Panel

Humidity 5% to 95% Relative humidity (Non-condensing)


AC Input

Operating Temperature -10°C~50°C


Utility
Storage Temperature -15℃ ~60℃
BAT input

CERTIFICATION & STANDARDS

CE-LVD (IEC62109-1, EN IEC62109-2); UKCA-(BS EN 62109-1, BS EN 62109-2)


Inverter
Generator Battery

92
Products / 120V

HIGH FREQUENCY OFF GRID SOLAR INVERTER


MODEL PV18-6048 TLV

PV1800 TLV Series Nominal Battery System Voltage 48VDC

INVERTER OUTPUT
6KW | 120V,240V | Wifi
Rated Power 6000W
This split phase solar inverter PV1800 TLV series, capacity 6KW, DC 48V, it’s
applicable to 110VAC/120VAC markets demands, which has AC output of single Surge Power 12000VA
phase 110VAC/120V, split phase 220V/240V; In LCD display, you can set output
voltage, frequency, charging voltage, charging current to design best use based Waveform Pure sine wave
on different loads applications; meanwhile, it has built-in two 80A MPPT solar
charge controllers, you can take use of sunshine freely and save electricity bills. AC Voltage Regulation (Batt.Mode) 120VAC/240VAC ±5% (L-L)

Inverter Efficiency(Peak) 90%~93%

Transfer Time 10ms (UPS / UL) 20ms (APL)

■ Pure sine wave solar inverter


AC INPUT
■ Output power factor 1
Voltage 240VAC
■ Built-in two 80A MPPT solar charge controllers

■ 2 units can be wired in parallel to create a split-phase system Selectable Voltage Range 214~264VAC(UL)
with 120V and 240V capabilities

■ WIFI remote monitoring (optional) Frequency Range 50Hz / 60Hz(Auto sensing)

■ Acid or Lithium Battery Select BATTERY


■ CAN/RS485 communication for BMS
Normal voltage 48VDC
■ Compatible to generator
Floating Charge Voltage 54.8VDC

Overcharge Protection 60VDC


Back panel description
SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage 250V


1 2 3 4 5 6 7 11 12 13 14

Maximum Solar Charge Current 80A/80A


1. Ground 8. Communication port
2. Input breaker1 9. USB port
PV Array MPPT Voltage Range 60~200VDC
3. Input breaker2 10. Dry contact
4. AC output 11. Battery input PV Input Power 4000W/4000W
5. AC input 12. WIFI port
6. RS-485 Communication port 13. PV1 input Maximum Efficiency 98%

7. CAN port 14. PV2 input


Maximum AC Charge Current 60A/60A
15. Power on/off switch
8 9 10 15 Maximum Charge Current 280A

MECHANICAL SPECIFICATIONS

Solar system connection Machine Dimension (W*H*D) 318*560*249mm

Package Dimension (W*H*D) /

PV1 input
N.W 20kg
Solar Panel
G.W 22kg
TV Fridge Lighting Fans

PV2 input OTHER


Solar Panel

Humidity 5% to 95% Relative humidity (Non-condensing)


AC Input
Operating Temperature -10°C~50°C
Utility
BAT input Storage Temperature -15℃ ~60℃

CERTIFICATION & STANDARDS


Inverter
Generator Battery
CE-LVD (IEC62109-1, EN IEC62109-2); UKCA-(BS EN 62109-1, BS EN 62109-2)

94
Products / 120V

LOW FREQUENCY SOLAR INVERTER PV29- PV29- PV29- PV29- PV29- PV29- PV29-

PV2900 LHP Series


MODEL
1KW-HP 1.5KW-HP 2KW-HP 3KW-HP 4KW-HP 5KW-HP 6KW-HP
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT

1~6KW | AC 120V | MPPT80A | WIFI | BMS | Dual output Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
PV2900 LHP series is very economical pure sine wave solar inverter, AC voltage Capable Of Starting Electric Motor 1P 1P 1.5P 2P 3P
110V/120V, AC charger inbuilt, from 20A to 60A; MPPT solar charger 80A Waveform Pure sine wave / same as input (bypass mode)
inbuilt; Solar/AC priority is configurable, when setting solar priority, solar will Nominal Output Voltage RMS 110V / 115V / 120VAC(±10% RMS)
charge batteries as first priority, and AC can also charge batteries when solar
Output Frequency 50Hz / 60Hz ±0.3Hz
charger current is not enough, it enables inverter to operate with all kinds of
home appliances, widely selling to Latin America. Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)

■ Pure sine wave output 100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ 3 Steps charging Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Overload and short-circuit protection Load > 125% (alarm 10s then stop output and fault code 07)
■ Set charging voltage/charging current. AC INPUT
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
Voltage 110/120VAC
■ Power-save mode
■ Set utility priority/ Battery priority Selectable Voltage Range 75~135VAC (For personal computers)
■ Set utility input wide/narrow range Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Inverter voltage can be set to 120V:110V/115V/120V
BATTERY
■ Inverter frequency can be set to 50/60Hz
■ Set utility charging on/off switch Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ 80A MPPT charger Low Battery Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Acid or Lithium Select
Low Battery Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ WiFi port (optional)
■ With BMS lithium battery communication function (CAN port) High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Dual output for smart load management High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Back panel description Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
1. Power on/off switch Output Voltage Depends on battery type
2. BAT - Overcharge Protection S.D. 15.5VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
1~3KW 4~6KW 3. BAT + Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
4. AC Input PAYPASS & PROTECTION
5. Main load Input Voltage Waveform Sine wave (grid or generator)
1 2 3 4 5 6 7 1 2 3 4 5 6 7 6. Second load Nominal Input Frequency 50Hz or 60Hz
7. PV input
Overload Protection (SMPS Load) Circuit breaker
8. Fan
Output Short Circuit Protection Circuit breaker
9. Remote port
BACK SIDE AC Input Breaker 1-3K/40A 4-6K/63A
10. BMS Can Port
SOLAR CHARGER
11. AGS port
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
12. USB port
Maximum PV Charge Current 80A±4A
13. WIFI port (optional)
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
8 9 10 11 13 12 14 15 8 9 13 12 11 10 16 14. AC input protect
MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
15. AC output 10A(max)
Maximum PV Array Open Circuit Voltage 245VDC
16. AC Input breaker
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall Mount
Dimensions (W*H*D) 274*484*174mm 274*568.5*174mm
PV input Package Dimensions (W*H*D) 583.5*376*255mm 668.5*376*255mm

Fridge Lighting Fans


N.W (kg) / /
Solar Panel
G.W (kg) / /
AC Input
Main Load OTHER
Operation Temperature Range 0℃ to 40℃
Utility Storage Temperature -15℃ to 60℃

BAT input
Second Load Audible Noise 60dB MAX
Display LED+LCD
TV Air conditioner Washing machine
Standard Warranty 1 year
Generator Battery Inverter
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

96
Products / 120V

LOW FREQUENCY SOLAR INVERTER PV30- PV30- PV30- PV30- PV30- PV30- PV30-

PV3000 LVHM Series


MODEL 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW
LVHM LVHM LVHM LVHM LVHM LVHM LVHM
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
1~6KW | AC120V | MPPT 80A | WIFI | BAT-CAN
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable Of Starting Electric Motor 1HP 1HP 1.5HP 1.5HP 2HP 3HP
PV3000 LVHM series is very economical pure sine wave solar inverter, AC
voltage 110V/120V, AC charger inbuilt, from 20A to 60A; MPPT solar charger Waveform Pure sine wave / same as input (bypass mode)
80A inbuilt; Solar/AC priority is configurable, when setting solar priority, solar Nominal Output Voltage RMS 110V / 115V / 120VAC(±10% RMS)
will charge batteries as first priority, and AC can also charge batteries when Output Frequency 50Hz / 60Hz ±0.3Hz
solar charger current is not enough, it enables inverter to operate with all kinds Inverter Efficiency (Peak) >88%
of home appliances, widely selling to Latin America.
Line Mode Efficiency >95%
Power Factor 1.0
■ Pure sine wave output Typical Transfer Time 10ms(max)
■ 3 Steps charging
100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ Overload and short-circuit protection Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Set charging voltage/charging current. Load > 125% (alarm 10s then stop output and fault code 07)
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
AC INPUT
■ Power-save mode
■ Set utility priority/ Battery priority Voltage 110/120VAC
■ Set utility input wide/narrow range Selectable Voltage Range 75~135VAC (For personal computers)
■ Inverter voltage can be set to 120V:110V/115V/120V Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Inverter frequency can be set to 50/60Hz BATTERY
■ Set utility charging on/off switch
Minimum Start Voltage (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ 80A MPPT charger
Low Battery Alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Acid or Lithium Select
■ WiFi port (optional) Low Battery Cut Off 10V/ 10.5V/ 11V/ 11.5V/12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ With BMS lithium battery communication function (CAN port) High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search Mode Load ≤50±20W(120V)
Back panel description CHARGER
Output Voltage Depends on battery type
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
1~3KW 4~6KW 1. BAT - Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
2. BAT + BYPASS & PROTECTION
1 3 4 5 6 3 7 8 1 3 4 5 6 3 8 3. GND Input Voltage Waveform Sine wave (grid or generator)
4. AC Input
5. AC Output Nominal Input Frequency 50Hz or 60Hz
6. PV Input Overload Protection (SMPS Load) Circuit breaker
7. AC Input protect
Output Short Circuit Protection Circuit breaker
8. Wifi (optional)
9. AC Output 10A(MAX) AC input breaker 1-2K/30A 3K/40A 4-6K/63A
10. USB SOLAR CHARGER
11. AGS
12. BAT CAN Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
13. Remote port Maximum PV Charge Current 80A±4A
14. FAN DC Voltage 12V / 24V auto work 24V / 48V auto work
15 14 13 2 12 11 10 9 15 14 13 2 12 11 10 7 15. Power on/off switch
15~95VDC @ 12V 30~230VDC @ 24V
MPPT Range @ Operating Voltage 60~230VDC @48V
30~230VDC @ 24V 60~230VDC @48V
Maximum PV Array Open Circuit Voltage 245VDC
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall Mount
Machine Dimension (W*H*D) 493*303*200mm 531*305*202mm

PV input
Package Dimension (W*H*D) 615*400*319mm 688*400*319mm
TV Fridge Lighting Fans N.W / /
Solar Panel G.W / /
OTHER
AC Input
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Utility
Audible Noise 60dB MAX
BAT input Display LED+LCD
Standard Warranty 1 year
CERTIFICATION & STANDARDS
Inverter
Generator Battery /

98
Products / 120V

LOW FREQUENCY SPLIT PHASE SOLAR INVERTER PV33-3024 PV33-3048 PV33-4024 PV33-4048 PV33-5048 PV33-6048

PV3300 TLV Series


MODEL
TLV TLV TLV TLV TLV TLV

INVERTER OUTPUT
Rated power 3KW 4KW 5KW 6KW
3~6KW | AC110V/220V | MPPT 80A | WiFi | BAT-CAN Power factor 1
Wave form Pure sine wave
This split phase solar inverter PV3300 TLV series, capacity range from 3KW-
Output voltage RMS 100V / 110V / 120VAC (200V / 220V / 240VAC) ±10%
6KW, DC24V/48V, it’s applicable to 110VAC/120VAC markets demands, which
has AC output of single phase 110VAC/120V, split phase 220V/240V; In LCD Output frequency 50Hz or 60Hz (±0.3Hz)
display, you can set output voltage, frequency, charging voltage, charging Inverter efficiency (peak) >85%
current to design best use based on different loads applications; meanwhile,
Line mode efficiency >95%
it has built-in MPPT solar charge controller 80A, you can take use of sunshine
freely and save electricity bills. 100%<Load<110% (alarm 5min then stop outputand fault code 07)
Overload 110%<Load<125% (alarm 60s then stop output and fault code 07)
Load > 125% (alarm 10s then stop output and fault code 07)
Surge rating 9000VA 12000VA 15000VA 18000VA
Capable of starting electric motor 1.5P 2P 3P
■ Friendly user interface; MFD (multi-function display) BATTERY
■ 3 Steps charging Battery voltage 24VDC/48VDC 48VDC
■ Overload and short-circuit protection
Minimum start voltage 10V/ 10.5V/ 11V/ 11.5V/ 12V±0.5V; 12VDC×2 for 24V; ×4 for 48VAC
■ Set charging voltage/charging current.
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V low voltage fault code 04
(10V/ 10.5V/ 11V/ 11.5V/ 12V) for 12V model
■ Set utility priority/ Battery priority Low battery cut off
(21V/21V /22V/ 23V/ 24V) for 24V model
■ Set utility input wide/narrow range (40V/ 42V/ 44V/ 46V/ 48V) for 48V model
■ Inverter voltage can be set to 100/110/120; frequency can be set to 50/60Hz
Add 0.5/battery: (low battery alarm one second one time)
■ Set utility charging on/off switch (10V/ 10.5V/ 11V/ 11.5V/ 12V) +0.5VDC for 12V model
Low battery alarm
■ Built-in 80A MPPT charger (21V/ 21V/ 22V/ 23V/ 24V) +1VDC for 24V model
■ Acid or Lithium Select (40V/ 42V/ 44V/ 46V/ 48V) +2VDC for 48V model
■ WiFi port (optional) Add +1V/battery: (high voltage one second one time / after 30s fault 03)
(12-14.5V) +1VDC for 12V model
■ With BMS lithium battery communication function (CAN port) High voltage alarm
(24-29V) +2VDC for 24V model
(48-58V) +4VDC for 48V model
Back panel description
Save mode Load ≤40W(110V) / 80W(220V)
AC INPUT MODE
Input waveform Pure sine wave
1 2 3 4 5 6 7 Nominal input voltage 200Vac / 220Vac / 240Vac
1. Battery -/+
2. PV -/+ Max input voltage 270Vac MAX
3. Switch on/off Input frequency 50Hz / 60Hz (auto sensing)
4. AC Output: HOT1-HOT2 200VAC/220VAC/240VAC
5. AC Output: HOT1-N 100VAC/110VAC/120VAC Efficiency (AC mode) >95% (load, full battery)
9
6. AC Output: HOT2-N 100VAC/110VAC/120VAC Transfer time AC to DC 15ms(typical)
8
7. AC Input: HOT1-HOT2 200VAC/220VAC/240VAC
13 8. Remote Port SOLAR CHARGER
10 9. BAT CAN Maximum PV Array Power 2500W 5000W 2500W 5000W 5000W 5000W
11 10. AGS
12 11. USB Maximum PV Charge Current 80A±4A
12. WiFi (optional) DC Voltage 24V / 48V 24V / 48V
13. AC Input breaker
MPPT Range @ Operating Voltage 30~230VDC @ 24V /60~230VDC @48V 60~230VDC @48V
Maximum Solar Input Voltage 245±2Vdc 245±2Vdc
Maximum Efficiency >98%
Standby Power Consumption <2W
Solar system connection
CHARGE MODE
12V / / / /

PV input Max charge current (±5A) 24V 40A 60A / /


Lighting Lighting Lighting Lighting 48V 20A 30A 35A 40A
Solar Panel Min charge current 10A. Change by every 5A
DIMENSIONS
120VAC LOAD
AC Input HOT1&N or Hot2&N Machine Dimension (W*H*D) 443*359.2*188mm 544*362*188mm
240VAC LOAD Package Dimension (W*H*D) 598*457*308mm 698*457*308mm
Utility HOT1&Hot2
N.W / /

BAT input G.W / /

Generator
Lighting Lighting Lighting Lighting
Warranty 1year

Inverter CERTIFICATION & STANDARDS


Battery
CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2)

100
Products / 120V

LOW FREQUENCY SOLAR INVERTER MODEL PV36-8048 TLV PV36-10048 TLV PV36-12048 TLV

PV3600 TLV Series Nominal Battery System Voltage


INVERTER OUTPUT
48VDC 48VDC 48VDC

Rated power 8.0KW 10.0KW 12.0KW


8~12KW | 245V | 100A, 200A Surge rating 24000VA 30000VA 36000VA
Capable of starting electric motor 4HP 5HP 6HP
PV3600 TLV series is a multi-function inverter ,combining functions of inverter
Waveform Pure sine wave / same as input (bypass mode)
and MPPT solar charger controller, solar charger and battery charger to offer
uninterruptible power support. The comprehensive LCD display offers user- Nominal output voltage RMS 100V/110V/120V/200V/220V/240V
configurable and easy-accessible button operation such as battery charging Output frequency 50Hz / 60Hz ± 0.3Hz
current, AC/solar charger priority, and selectable input voltage based on Inverter effciency(peak) >88%
different applications.
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 20ms(max)
AC INPUT
■ Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.) Voltage 220V/230V/240V

■ Built-in MPPT solar charge controller 100A/200A Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
■ MPPT efficiency max 98%
BATTERY
■ Powerful charge rate up to 140Amp
Low battery voltage cutoff 40-48VDC for 48VDC mode
■ Inside BMS function
Low battery voltage recover 42-50VDC for 48VDC mode
■ DC start &Automatic Self-Diagnostic Function High battery voltage cutoff 60VDC for 48VDC mode
■ WIFI / USB monitoring function (wi-fi optional) High battery voltage recover 57VDC for 48VDC mode
■ Supporting AGS, BTS port Idle consumption-search mode <80W when power saver on

■ Compatible to generator AC CHARGER


Output voltage Depends on battery type
Charger AC input breaker rating 80A 80A 80A
Overcharge protection S.D. 62.8VDC for 48VDC mode
Back panel description Maximum charge current 60A 70A 80A
BTS

1 2 3 4 Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
1. BAT- 9. BTS port Input voltage waveform Sine wave (grid or generator)
2. BAT+ 10. Wifi communication port Nominal input frequency 50Hz or 60Hz
3. AC input breaker 11. AC input Overload protection (SMPS Load) Circuit breaker
4. AC output breaker 12. AC outputr
Output short circuit protection Circuit breaker
5. Remote control port 13. PV2 input
Bypass breaker rating 63A 63A 63A
6. Fan 14. PV1 input
Max bypass current 80A
7. USB port 15. Ground
SOLAR CHARGER
8. AGS port
Maximum PV charge current 100A/200A
5 6 7 8 9 10 11 12 13 14 15 DC voltage 48V
Maximim PV array power 5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC) 64~235VDC
Solar system connection Maximum PV array open circuit voltage 250VDC
Maximum effciency >98%
Standby power consumption <2W
PV1 input MECHANICAL SPECIFICATIONS
Mounting Wall mount
PV2 input TV Fridge Lighting Fans
Solar Panel
Dimensions (W*H*D) 674*402*222mm
Package Dimensions (W*H*D) 818*577.5*415mm
AC Input
OTHER
Operation temperature range 0°C to 50°C
Utility
Storage temperature -15°C to 60°C
BAT input Audible noise 60dB MAX

Generator Display LED+LCD


Inverter CERTIFICATION & STANDARDS
Battery CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)

102
Products / 120V

LOW FREQUENCY SOLAR INVERTER MODEL PV3900-12048 TLV

PV3900 TLV Series Nominal Battery System Voltage


Stand-alone mode
48VDC
Yes
Parallel operation 3 units
12KW | 250V | 200A INVERTER OUTPUT
Rated power 12.0KW
PV3900 TLV series is a multi-function inverter ,combining functions of inverter Surge rating 36000VA
and MPPT solar charger controller, solar charger and battery charger to offer Capable of starting electric motor 6HP
uninterruptible power support. The comprehensive LCD display offers user- Waveform Pure sine wave / same as input (bypass mode)
configurable and easy-accessible button operation such as battery charging Nominal output voltage RMS 100V/110V/120V/200V/220V/240V
current, AC/solar charger priority, and selectable input voltage based on Inverter effciency(peak) >90%
different applications.
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 10ms(max)
AC INPUT
Voltage 220V/230V/240V
■ Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
Selectable voltage range 90-280 VAC (APL)
■ Built-in MPPT solar charge controller 200A Frequency range 50Hz / 60Hz
■ MPPT efficiency max 98% BATTERY

■ Powerful charge rate up to 200A Low battery voltage cutoff 40-48VDC for 48VDC mode
Low battery voltage recover 42-50VDC for 48VDC mode
■ Inside BMS function
High battery voltage cutoff 60VDC for 48VDC mode
■ DC start &Automatic Self-Diagnostic Function High battery voltage recover 57VDC for 48VDC mode
■ WIFI monitoring function (optional) Idle consumption-search mode <50W
AC CHARGER
■ Compatible to generator
Output voltage Depends on battery type (Supports lead-acid, gel, and lithium batteries)
■ Parallel operation with up to 3 units
Charger AC input breaker rating 100A
Overcharge protection S.D. 62.8VDC for 48VDC mode
Maximum charge current 10-140A (setting) battery terminal
Back panel description
BTS
Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
1 2 3 4 5 6 7 Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Software + Circuit breaker
1. Battery -/+ 8. AC output switch
Output short circuit protection Software + Circuit breaker
2. Communication port 9. AC input switch
Bypass breaker rating 63A
3. PV input 1 10. Lighting protection
Max bypass current 80A
4. PV input 2 11. PV2 Switch
SOLAR CHARGER
5. GEN port 12. PV1 Switch
Maximum PV charge current 200A
6. Grid port 13. WiFi port
DC voltage 48V
7. AC ouput
Maximim PV array power 10000W
13 12 11 10 9 8 MPPT range @ operating voltage(VDC) 64~235VDC
Maximum PV array open circuit voltage 250VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Parallel operation Solar system connection
Mounting Wall mount
Packing Wooden box
Dimensions (W*H*D) 439*570*233mm
Package Dimensions (W*H*D) 690*214*520mm
N.W 42kg
G.W 47kg
Warranty 1years
PV2 PV1 Home Load
OTHER
Operation temperature range 0°C to 50°C
Battery
Storage temperature 15°C to 60°C
Grid
Audible noise 60dB MAX
Loads N
L Communication WiFi
Display LED+LCD
CERTIFICATION & STANDARDS
Utility Grid N
L
Battery Generator
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011); UL1741

104
Products / 120V

HIGH FREQUENCY POWER INVERTER/CHARGER


MODEL EP18-3024LV
EP1800 LV Series Rated output power 3000VA/3000W

Surge Power 6000W


3KW | 48V | 120V
AC INPUT

This is a multi-function inverter/charger, combining functions of inverter, Nominal Input Voltage 120Vac±5%
battery charger to offer uninterruptible power support with portable size.
Its comprehensive LCD display offers user-configurable and easy-accessible Selectable Voltage range 90~145VAC(UPS) / 74~145VAC(APL) / 108~132VAC(VDE)
button operation such as battery charging current,
Frequency Range 50Hz/60Hz (Auto sensing)
AC charger priority, and acceptable input voltage based on different
applications. Inverter Efficiency(Peak) 95%

INVERTER OUTPUT

Output voltage waveform Pure sine wave

■ Pure sine wave inverter Output Voltage Regulation 120Vac ± 5%


■ Configurable input voltage range for home appliances and personal
Output Frequency 50Hz / 60Hz(Auto sensing)
computers via LCD setting
■ Configurable battery charging current based on applications Power Factor ≈1
via LCD setting
■ Configurable AC Charger via LCD setting Transfer Time 10ms (UPS / VDE4105) / 20ms (APL) <50ms(For parallel operation)
■ Compatible to mains voltage or generator power
Nominal DC Input Voltage 24VDC
■ Auto restart while AC is recovering
■ Overload/ Over temperature/ short circuit protection Cold Start Voltage 23VDC
■ Smart battery charger design for optimized battery performance Output Short Line mode Circuit Breaker
■ Acid or Lithium select Circuit
■ Parallel operation with up to 3 units Protection Battery mode Electronic Circuits
■ WIFI remote monitoring (optional) BATTERY
■ With BMS lithium battery communication function (CAN port)
Battery voltage 24VDC

Back panel description Floating voltage 27.4V

Overcharge Protection 30V


1 2 3 4 5 6 7 11
CHARGER

Charging Current(UPS) @Nominal Input Voltage Default:30A; MAX:80A

Bulk Charging Voltage 28.8Vdc

Floating Charging Voltage 27.4Vdc

10 9 8 Charging Algorithm 3-Step

1. Circuit breaker 5. USB port 9. Parallel communication port (only for parallel model) GENERAL
2. AC input 6. Dry contact 10. Parallel switch
Mounting Wall mount
3. AC output 7. Power on/off switch 11. WiFi port (optional)
4. RS485 communication port 8. Battery input Display LED+LCD

Parallel operation 3 units

Solar system connection Operation Temperature Range -10℃ to 50℃

Storage Temperature -15℃ to 60℃

Standard Warranty 1 year


PV input
TV Laptop Air-conditioning Washing machine
MECHANICAL SPECIFICATIONS
Solar Panel

Machine Dimension (W*H*D) 297.5*468*125mm


MPPT solar charge
controller
Package Dimension (W*H*D) /

AC Input
N.W /

Inverter Utility G.W /


BAT input
CERTIFICATION & STANDARDS
Generator
CE

106
Products / 120V

POWER INVERTER/CHARGER MODEL


EH29-0312 EH29-0412 EH29-0512 EH29-0612 EH29-0812 EH29-1012 EH29-0624 EH29-0824 EH29-1024

EH2900 LV Series
LV LV LV LV LV LV LV LV LV

Default Battery System Voltage 12VDC 24VDC


INVERTER OUTPUT
Rated Power 300W 400W 500W 600W 800W 1000W 600W 800W 1000W
300W~1000W | 12V/24V | 10~30A | AC 120V Surge Rating 900VA 1200VA 1500VA 1800VA 2400VA 3000VA 1800VA 2400VA 3000VA
Waveform Pure sine wave
EH2900 LV series inverter is a cost effective, intelligent with UPS function. Voltage Regulation Battery mode: 110 or 120VAC Line mode: 95~125VAC
The comprehensive LCD offers user-configurable and easy-accessible button Output Frequency 50Hz / 60Hz
adjustment such as battery charge current, battery charge voltage, frequency, Invertert Frequency (Peak) >75% >81%
buzzer etc. It's perfect for the user who need a simple and economical Bypass Efficiency >95%
inverter,with user-friendly installnation and setting. Output Transfer Time 8ms(typical) 12ms(max)
AC INPUT
Voltage 110/120VAC
Selectable Voltage Range 70~140VAC ±5%
Low Battery Alarm 70VAC ±5%
Low Voltage Recover 75VAC ±5%
■ Sine wave inverter
High Battery Alarm 140VAC ±5%
■ Adjustable charging current from utility High Voltage Recover 135VAC ±5%
■ Adjustable battery charging current Low Frequency Alarm 45 ±5Hz
■ 3 steps charging algorithm Low Frequency Recover 46 ±5Hz
■ Friendly user interface High Frequency Alarm 65 ±5Hz
■ Multi-function display High Frequncy Recover 64 ±5Hz
■ Overload and short-circuit protection Nominal Input Range 50Hz / 60Hz ±5Hz
■ Battery reverse polarity protection AC Auto Restart YES
■ Deep discharge protection BATTERY
■ Automatic voltage regulationCommunication with PC Minimum Start Voltage Low Battery Voltage Cutoff+0.5V Low Battery Voltage Cutoff+0.5V
Low Battery Alarm Low Battery Voltage Cutoff+0.5V Low Battery Voltage Cutoff+1.0V
Min battery voltage for power on Shutdown voltage +0.5V Shutdown voltage +1V
Low Battery Cutoff 10-12.0VDC 20.0-24.0VDC
High Battery Alarm (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC)
AC CHARGE
Floating Voltage 13.5-14.5VDC 27-29VDC
Back panel description
Boost Voltage 13.8~14.5VDC 27.6~29VDC
300W 400W 500W 600W 800W 1000W 600W 800W 1000W
1. LCD display Maximum Charge Current
10A 10A 15A 20A 25A 30A 10A 15A 15A
2. Fault LED BYPASS & PROTECTION
3. Charge LED Input Waveform Pure sine wave
1 2 3 4 5 10
4. AC/Inverter LED Input Frequency 50Hz or 60Hz
5. ESC Overload Protection >110%~125% Load foult affter 60s; >125%~150% Load foult affter 3s; >150% Load fault after 500ms
8 6. SEL Over Temperature Protection ≥90℃
6
7. Enter Bypass Output Protection 15A 250VAC
9
8. Power on Output Circuit Protection YES
7
9. Power off Battery Reverse Protection Optional
Battery Low Voltage Protection YES
11 12 13 10. USB
Battery High Voltage Protection YES
11. Battery input
Bypass Breaker Rating 15A
12. AC input
Maximum Bypass Current 15A
13. AC output
MECHANICAL SPECIFICATION
Machine Dimension (W*H*D) 319*300.5*132.2mm
Solar system connection Package Dimension (W*H*D) 391*325*187mm
G.W (kg) /
N.W (kg) /
Operating Temperature 0℃ ~40℃ 0~90% relative humidity (non-condensing)
PV input
Storage Temperature -15℃ to 55℃
TV Laptop Lighting Fans
Altitude ≤1000M
Solar Panel MPPT solar charge Audible Noise ≤60dB
controller
Display LED+LCD
Cooling Mode Fan cooling
Fan Starting >45℃ starting, <30℃ Closing
AC Input
Communication USB
Inverter Utility
CERTIFICATION & STANDARDS
BAT input CE-LVD (EN IEC62109-1:2010,EN IEC62109-2:2011)
CE-EMC+LVD (EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011)
Generator IEC60950-1:2005A+1:2009+A2:2013
EN IEC62040-1:2019

108
Products / 120V

LOW FREQUENCY POWER INVERTER/CHARGER EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30-

EP3000 LV2 Series


MODEL 1012 1024 1512 1524 2012 2024 3024 3048 4024 4048 5048 6048
LV2 LV2 LV2 LV2 LV2 LV2 LV2 LV2 LV2 LV2 LV2 LV2
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
1~6KW | AC120V | WIFI | BAT-CAN Reted Power 1.0KW 1.5KW 2KW 3KW 4KW 5KW 6KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
EP3000 LV2 series is very economical pure sine wave inverter, special in north
Capable Of Starting Electric Motor 1HP 2HP 3HP
& south america market, and AC charger from 35A to 70A .Solar/AC priority
configurable . When solar priority , in case its charge current lower than Waveform Pure sine wave/ same as input (bypass mode)
inverter’s charger from AC , AC will supplement to charge the batteries , Nominal Output Voltage RMS 110V/115V/120VAC ±10% (RMS)
to optimize charging. With low frequency transformer ,it enable the inverter to
Output Frequency 50Hz / 60Hz±0.3 Hz
operate with all kinds of home appliances.
Inverter Efficiency(Peak) >88%
■ 3 Steps charging Line Mode Efficiency >95%
■ MFD (multi-function display) Power Factor 1.0
■ Overload and short-circuit protection
Typical Transfer Time 10ms(max)
■ Set charging voltage/charging current.
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V 100% < Load < 110% (alarm 5min then stop output and fault code 07)
Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Power-save mode Load > 125% (alarm 10s then stop output and fault code 07)
■ Set utility priority/ Battery priority
AC INPUT
■ Set utility input wide/narrow range
■ Inverter voltage can be set to 110V/115V/120V Voltage 120VAC
■ Inverter frequency can be set to 50/60Hz Selectable Voltage Range 75~135VAC(For Personal Computers)
■ Set utility charging on/off switch Frequency Range 50Hz/60Hz (Auto sensing) 40~80Hz
■ Acid or Lithium Select
BATTERY
■ WIFI monitoring function (optional)
Minimum Start Voltage (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ With BMS lithium battery communication function (CAN port)
Low Battery Alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut off 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Back panel description High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
1~3KW 4~6KW
Idle Consumption-Search Mode Load ≤50±20W(120V)
13 1 14 3 4 5 2 3 6 13 1 14 3 4 5 2 3 6
CHARGER
Output Voltage Depends on battery type
7
Charger AC Input Breaker Rating 1K/30A 3K/40A 4-6KW/63A
8 8
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
9 9
10 10 Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
11 11
12 12 BYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)

1. BAT - 6. AC input protect 11. USB Nominal Input Frequency 50Hz or 60Hz
2. BAT + 7. AC Output 10A(MAX) 12. WiFi Overload Protection (SMPS Load) Circuit breaker
3. GND 8. Remote port 13. Power on/off switch Output Short Circuit Protection Circuit breaker
4. AC input 9. BAT CAN 14. FAN AC Input Breaker 30A 40A 50A / 63A
5. AC output 10. AGS
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Solar system connection Machine Dimension (W*H*D) 493*303*200mm 531*305*202mm
Package Dimension (W*H*D) 615*400*319mm 686*400*319mm
G.W /

PV input
N.W /
TV Laptop Lighting Fans
OTHER
Solar Panel MPPT solar charge
controller Operation Temperature Range 0°C to 40°C
Storage Temperature -15°C to 60°C
Audible Noise 60dB MAX
AC Input
Display LED+LCD
Utility
Standard Warranty 1 year
BAT input Inverter
CERTIFICATION & STANDARDS
Generator /

110
Products / 120V

LOW FREQUENCY SPLIT PHASE POWER INVERTER EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33-

EP3300 TLV Series


MODEL 1012 1024 1512 1524 2012 2024 3024 3048 4024 4048 5048 6048
TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV TLV
INVERTER OUTPUT

Rated power 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW


1~6KW | AC110V/220V | WIFI | BAT-CAN Surge rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable of starting electric
This split phase inverter EP3300 TLV series, capacity from 1KW-6KW, DC 1P 1P 1.5P 1.5P 2P 3P
motor
12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which
Power factor 1
matches AC 110VAC/120V single phase, or two phase 220V/240V; In LCD
display, you can set output voltage, frequency, charging voltage, charging Wave form Pure sine wave / Same as input wave form (bypass mode)
current to design best use based on different loads applications; meanwhile,
you can also connect extra solar charge controller to build a solar home system, Output voltage RMS 100V / 110V / 120VAC (200V / 220V / 240VAC) ±10%
take use of sunshine freely and save electricity bills. Output frequency 50Hz or 60Hz (±0.3Hz) (can be set)

Overload protection Breaker + software protection


■ Pure sine wave output Output short circuit Breaker + software protection
■ 3 steps charging
Inverter efficiency (peak) >85%
■ Overlord and short- circuit protection
■ Set charging voltage/charging current 100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ Power-save mode Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
Load > 125% (alarm 10s then stop output and fault code 07)
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Inverter voltage can be set to 100/110/120V
BATTERY
■ Inverter frequency can be set to 50/60Hz
Battery voltage 12VDC / 24VDC 24VDC / 48VDC 48VDC
■ Acid or Lithium select
■ WIFI monitoring function (optional) Minimum start voltage (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)

■ With BMS lithium battery communication function (CAN port) Low battery voltage cut off 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)

Low battery voltage alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)

High battery voltage alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Back panel description
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)

Save mode Load ≤50±20W(120V)/100±20W(220V)

AC INPUT MODE
1 2 13 9 10 11 12 1. Battery -/+ Input waveform Pure sine wave
2. Switch on/off
3. Remote port Nominal input voltage 200Vac / 220Vac / 240Vac
4. BAT CAN
Max input voltage 270Vac MAX
5. AGS
3 6. USB Input frequency 50Hz / 60Hz (auto sensing)
7. WiFi port
8
8. AC Input protect: Input protect breaker Efficiency (AC mode) >95% (load, full battery)
9. AC Output: HOT1 - HOT2 200VAC/220 VAC/240VAC
10. AC Output: HOT1 - N 100VAC/110 VAC/120VAC Transfer time AC to DC 15ms(max)
7
11. AC Output: HOT2 - N 100VAC/110 VAC/120VAC
Transfer time DC to AC 15ms(max)
12. AC Input:HOT1 - HOT2 200VAC/220 VAC/240VAC
4 5 6 13. Fan CHARGE MODE

Boost voltage 14.1V(Default) Range of adjustment 12-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)

Float voltage 13.5V(Default) Range of adjustment 12-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)

Solar system connection 12V 30A 45A 60A / / / /

24V 20A 25A 30A 40A 60A / /

48V / / / 20A 30A 35A 40A


Lighting Lighting Lighting Lighting Min charge current 10A. Change by every 5A
PV input BAT input DIMENSIONS

Solar Panel MPPT solar charge 120VAC LOAD Machine Dimension (W*H*D) 443*359.2*188mm 361.8*543.5*188.5mm
controller HOT1&N or Hot2&N
Package Dimension (W*H*D) 598*457*308mm 698*407*308mm
240VAC LOAD
HOT1&Hot2 G.W /
AC Input
N.W /
Utility
Inverter
Lighting Lighting Lighting Lighting Warranty One year (standard), 2 years optional (IP20)

CERTIFICATION & STANDARDS


Generator /

112
Products / 120V

ON/OFF GRID HYBRID SOLAR INVERTER MODEL


PH11-3648 PH11-4048

PH1100 LV Series
LV LV
RATED POWER 3600W 4000W
Nominal Battery System Voltage 48V
PV INPUT(DC)

3.6~4KW | Single Phase | 120VAC | IP65 Maximum recommended DC power 4600W 5200W
Nominal DC operating voltage 360V
Maximum DC voltage 500V
This is a flexible and intelligent energy storage solar inverter with a wide range
MPPT voltage range 120V~500V
of MPPT Voltage.
Combining functions of off grid and on grid. This hybrid solar inverter can Maximum input current 15A / 15A
power all kinds of appliances in home or office, and can also be used in power No.of MPP tracker 2
stations. Strings per MPP tracker 1
INVERTER OUTPUT(AC)
Nominal AC output power 3600W 4000W
Nominal output voltage; range 110/120/130V; 90~140V
AC grid frequency; range 50/60Hz; 45~55/55-65Hz
Nominal output current 30A 34A
■ Multiple operation modes: Grid-tie,off grid with storage backup Maximum output current 33A 36A
Inrush current (spike/duration) 72A/5.2us
■ IP65 water-proof and dust-proof
Total harmonic distortion i(THDi) <3%
■ MPPT voltage range 120-500V Power factor at rated power 1
■ Support LCD display&Smart LCD setting Displacement power factor 0.8leading ~ 0.8lagging
Grid type Single phase
■ Available Export control CT sensor function
BATTERY MODE OUTPUT(AC)
■ Multiple communications:USB,RS485,GPRS and wifi etc Output Rated Power 3600W 4000W
■ Full protection function:Over-voltage,over-frequency, over-current, Nominal output voltage; accuracy range 120±1%
over-temperature,and AC short-circuit automatic protection Output ferequency; accuracy range 50/60Hz (optional)±0.2%
■ Intelligent BMS battery management function Output rated current 30A 34A
Output waveform Pure sine wave
■ Fanless low-noise design
Peak power 5400W,10s 6000W,10s
■ Wifi monitoring Total harmonic distortion v (linear load) <3%
BATTERY & CHARGER
Back panel description Battery type Lead-acid battery / Lithium battery
Battery voltage 48V
Battery voltage range 40~60V
1 2 3 4 5 6 7 Charging curve 3-stage adaptive with maintenance
1. PV input terminals Protection Over-current protection / Over-temperature protection
2. Battery input terminals and cover Maximum charging power 3600W 4000W
3. Breather valve Maximum charging currernt 75A 85A
4. PV input switch EFFICIENCY
5. BTS terminals, BMS terminals, load monitor terminals, dry contact terminals, Maximum efficiency 97.1%
CAN communication terminals, USB terminal and cover Euro-efficiency 96.5%
6. Wi-Fi commodule MPPT efficiency 99.8%
7. AC output terminals and cover PROTECTION DEVICES
DC switch rating for each MPPT; Grid monitoring; Output over current protection; Output overvoltage protection-varistor; Ground fault monitoring;
Integrated all-pole sensitive leakage current
GENERAL
Machine Dimension (W*H*D) 480*420*215mm
Solar system connection Package Dimension (W*H*D) /
G.W 27kg
N.W /
DC connection H4 / MC4
AC connection Terminal Block
Display LED+LCD
Application Communication interfaces Wi-Fi / USB / GPRS / RS485
Ingress protection rating IP65
Solar Humidity 0~95% RH(No codensing)
Operating temperature range -20℃ +60℃ With derating above 45℃
Cooling concept Natural
Altitude <3000m
CERTIFICATION & STANDARDS
Grid CE-EMC+LVD (EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011); CE-LVD(EN62477-1:2022)
IEC60529; EN50549-1:2019
Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021)
C10/C11
UNE217001-2020; UNE217002-2020, NTS-631:2021 (Type A)
Battery (optional) Generator G98+G99

114
Products / 120V

MODEL PH16-3048 LV PH16-3548 LV PH16-4048 LV


AC-COUPLED ENERGY STORAGE INVERTER RATED POWER 3000W 3500W 4000W

PH1600 LV Series
Nominal Battery System Voltage 48V 48V 48V
INVERTER OUTPUT(AC)
Nominal AC output power 3000W 3500W 4000W
Nominal output voltage range 110/120,90~140 ±5VAC
3~4KW | Single Phase | 120VAC
AC grid frequency range 60Hz; 55-65Hz

The PH1600 LV Series is designed for retrofitting PV systems, including power Nominal output current 25A 29.1A 33.3A
classes ranging from 3kw to 4kw. It can be installed with existing PV inverters, Maximum output current 36.36A
forming an AC coupling system. Inrush current (spike/duration) 57.5A/5.2us
Capable of being grid-interactive, it allows users to store surplus power and
sell it back to the grid when demand peaks and the price of electricity is at its Total harmonic distortion i(THDi) @Nominal Output <3%
highest. It runs reliably under even the most extreme conditions with metal Power factor at rated power ≈1
aluminium housing with IP66 protection. Displacement power factor Adjustable from 0. 8 leading to 0. 8 lagging
Grid type Single phase
BATTERY MODE OUTPUT(AC)
Output Rated Power 3000W 3500W 4000W
Nominal output voltage; accuracy range 120±1%
■ LCD+LED – user friendly interface
Output ferequency; accuracy range 60Hz±0.2%
■ IP66 design for outdoor
Output rated current 25A 29.1A 33.3A
■ Compatible with other brands of inverter
Output waveform Pure sine wave
■ Various work mode for different application scenarios Peak power 3000VA, 10S 3500VA, 10S 4000VA, 10S
■ Natural cooling without external fan Total harmonic distortion v (linear load) <3%
■ BMS Function BATTERY & CHARGER
■ Wifi monitoring Battery type Lead-acid battery / Lithium battery

■ UPS level switching time <10 ms Battery voltage 48V ±0.3


Battery voltage range 40~60V ±0.3
■ Retrofit any on-grid systems to be able to run battery
Charging curve 3-stage adaptive with maintenance
Protection Over-current protection / Over-temperature protection

Back panel description Maximum charging power 3000W 3500W 4000W


Maximum charging currernt 80A
EFFICIENCY
1 2 3 4 5
Battery discharge (full load) ≥92%
Maximum battery charging current efficiency ≥92%
1. Battery input terminals and cover PROTECTION DEVICES
2. Breather valve
Grid monitoring Yes
3. BTS terminals, BMS terminals, load monitor terminals, dry contact terminals,
CAN communication terminals, USB terminal and cover Output over current protection Yes

4. Wi-Fi commodule Output overvoltage protection-varistor Yes


5. AC output terminals and cover Ground fault monitoring Yes
Integrated all-pole sensitive leakage current Yes
GENERAL
Machine Dimension (W*H*D) 420*420*215mm
Solar system connection Package Dimension (W*H*D) /
N.W 25kg
G.W /
AC connection Terminal Block
Display LED+LCD
Communication interfaces Wi-Fi/USB/GPRS/RS485/CAN
Ingress protection rating IP66
Humidity 0~95% RH(No codensing)
Operating temperature range -20℃ +60℃ With derating above 45℃
Cooling concept Natural
Noise figure [dB] ≤25
Altitude <3000m
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN IEC61000-6-3, ENIEC61000-6-1; EN IEC62477-1)

116
Products / 120V

HIGH FREQUENCY ON/OFF GRID SOLAR INVERTER PH18-3024 PH18-3048 PH18-6048


MODEL

PH1800 LV Series
LV LV LV

Nominal Battery System Voltage 24VDC 48VDC

INVERTER OUTPUT
3~6KW | 120V | Wifi
Rated Power 3000W 3000W 6000W
PH1800 LV Series is a multi-function inverter/charger, combining functions
of inverter, MPPT solar charger and battery charger to offer uninterruptible Surge Power 6000W 6000W 12000W
power support with portable size. Its comprehensive LCD display offers user-
configurable and easy-accessible button operation such as battery charging Waveform Pure sine wave
current, AC/solar charger priority, and acceptable input voltage based on
different applications. AC Voltage Regulation (Batt.Mode) 120VAC ±5% 120VAC ±5% 240VAC ±5% (L-L)

Inverter Efficiency(Peak) 90%


■ Pure sine wave solar inverter
Transfer Time 10ms (UPS / UL) 20ms (APL)
■ Output power factor 1

■ Built-in 80A MPPT solar charger AC INPUT

■ 2 units can be wired in parallel to create a split-phase system


with 120V and 240V capabilities Voltage 120VAC 120VAC 240VAC

■ Support parallel operation up to 3 units Selectable Voltage Range 107~132VAC(UL) 214~264VAC(UL)


■ WIFI remote monitoring (optional)
Frequency Range 50Hz / 60Hz(Auto sensing)
■ CAN/RS485 communication for BMS

■ Compatible to generator BATTERY

Normal voltage 24VDC 48VDC 48VDC

Floating Charge Voltage 27.4VDC 54.8VDC 54.8VDC

Overcharge Protection 30VDC 60VDC 60VDC


Back panel description
SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage 450VDC 250VDC 250VDC


6 7 8 9 11 10
1. AC input
2. AC output
Maximum Solar Charge Current 100A 80A 80A/ 80A
3. Circuit breaker
4. Battery input PV Array MPPT Voltage Range 90-430VDC 60-200VDC 60-200VDC
5. PV input
6. Power on/off switch PV Input Power 4000W 4000W 4000W/ 4000W
7. RS-485 Communication port
Maximum Efficiency 98%
12 13 14 16 17 15
8. USB
9. Dry contact Maximum AC Charge Current 80A 60A 60A
10. USB wifi
11. Parallel switch (only for parallel model) Maximum Charge Current 100A 140A 160A
12. Parallel communication port (only for parallel model)
MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 329*485*134mm 329*485*134mm 315*500*235

Package Dimension (W*H*D) 425*575*229mm 425*575*229mm /


Solar system connection
G.W 12kg 12kg 20kg

N.W 13.5kg 13.5kg 22kg


PV input
TV Fridge Lighting Fans
OTHER
Solar Panel

Humidity 5% to 95% Relative humidity (Non-condensing)


AC Input

Operating Temperature -10°C~50°C


Utility
Storage Temperature -15℃ ~60℃
BAT input

CERTIFICATION & STANDARDS

///////////////////
Inverter
Generator Battery

118
Products / 120V

PURE SINE WAVE INVERTER PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15-
MODEL

PI1500 LV Series
0312 LV 0324 LV 0612 LV 0624 LV 1012 LV 1024 LV 1512 LV 1524 LV 2012 LV 2024 LV

BATTERY DC INPUT

Input Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC
300~2000W | 12V,24V | 120V Low Voltage Protect Delay 2 seconds

PI1500 series is a pure sine wave inverter, high frequency machine solution, the (PB) 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC
Low Voltage Warning
product is small size, the solution is reliable and stable, the main function is to (LI) 10.5VDC 21.0VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC
invert the DC 12VDC battery or 24VDC battery to AC 120VAC output, mainly
used for emergency use Electricity, car inverter, outdoor electricity and other (PB) 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC
Low Voltage Protect
occasions. (LI) 11.5VDC 23.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC

(PB) 12.5VDC 25.0VDC 12.5VDC 25.0VDC 12.5VDC 25.0VDC 12.5VDC 23.0VDC 12.5VDC 23.0VDC
Low Voltage Restoring
(LI) 12.5VDC 25.0VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC

(PB) 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC
Over Voltage Protect
■ Input Voltage 12V / 24V DC optional (LI) 14.7VDC 29.4VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC

■ Output Voltage 120V AC optional (PB) 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC
Over Voltage Restoring
■ Portable power for AC products, AC outlets for connecting multiple loads (LI) 15.0VDC 30.0VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC
■ High efficiency converts virtually all of the battery's power to AC Parameters: (PB) Lead-acid Battery / (Ll) 4 series (12V), 8 series (24V) LiFePO4 Lithium Battery Pack
■ Mounting brackets for convenient installation
INVERTER AC OUTPUT
■ Overload and over temperature shut down
Default Power 300W 600W 1000W 1500W 2000W
■ Low voltage and over voltage alarm/cut off
Peak Power 600W 1200W 2000W 3000W 4000W
■ Short circuit protection
Output AC Voltage 120V 120V 120V 120V 120V

Output AC Frequency 60Hz 60Hz 60Hz 60Hz 60Hz

Output Wave Pure Sine Wave

Output Wave THD < 3%


Solar system connection PROTECTION

Battery Input Protection Low Voltage Protection, Over Voltage Protection, Reverse Protection

Inverter Output Protection Output Overload, Short-Circuit, Over Temperature Protection


PV input BAT input
DISPLAY

PV Battery LED Display Red: Error ; Green: System OK

MPPT Solar Chage LED Digital Display / Display Battery Voltage, Output Power, Output Voltage, Error Numbers
Controller
Inverter DC OUTPUT

USB USB-A type (5V1A)

12V/24V EFFICIENCY
Car cigarette lighter
(Load must lower 120W; Available for 300W only) Peak Conversion efficiency 91% 91% 90% 88% 90% 88% 90%

ENVIRONMENT
Laptop Lighting TV Fans

Protection Degree IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20

Working Environment Indoor Fan cooling

Environmental temperature 0~45°C


Type
Ambient humidity 20%--90%, No condensation

Altitude ≤3000m

DIMENSIONS

Machine Dimension (W*H*D) 205*125*61mm 242*158*81mm 291*220*83mm 380.8*248*90 mm

Package Dimension (W*H*D) 228*176*102mm 268*205*140mm 330*267*147mm 420*300*150mm

N.W (kg) 1kg 1.7kg 2.6kg 4.5kg

G.W (kg) 9.3kg (8pcs) 15kg (8pcs) 23kg (8pcs) 19kg (4pcs)

CERTIFICATION & STANDARDS


CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2)
CE-LVD(EN 62477-1/A11)

120
Products / Controller

MPPT SOLAR CHARGE CONTROLLER MODEL PC18-6015F PC18-8015F PC18-10015F

PC1800F Series Nominal Battery System Voltage

CONTROLLER INPUT
12V / 24V / 48VDC (Auto detection); 36V (Setting)

Battery Voltage 12V / 24V / 36V / 48V


60~100A | 12V,24V | 145V 12V (VBAT) 100V

MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an Maximum Solar Input 24V (VBAT) 145V
efficient, safe, multi-stage recharging process that prolongs battery life and Voltage 36V (VBAT) 145V
assures peak performance from a solar array. Each Charge Controller allows
customized battery recharging. 48V (VBAT) 145V

12V (VBAT) 15-95V

PV Array MPPT Voltage 24V (VBAT) 30~130V


Range 36V (VBAT) 45~130V
■ LCD display , easy to operate on LCD screen 48V (VBAT) 60~130V
■ Multi stage charging 12V (VBAT) 940W 1250W 1560W
(3-stage charging , parallel charging and equalized charging function)
24V (VBAT) 1880W 2500W 3120W
■ Maximum Solar Input Voltage: 145V Maximum Input Power
36V (VBAT) 2820W 3750W 4680W
■ BTS – Battery remote temperature sensor terminal
48V (VBAT) 3760W 5000W 6250W
■ Enable to charge Li-thium, Gel , lead-acid battery
BATTERY
■ With RS485 & USB communication port
Flooded Absorption Stage 14.2V / 28.4V / 42.6V / 56.8V
■ Protection: PV array short circuit, PV reverse polarity, Battery reverse polarity,
Over charging, Output short circuit Battery Float Stage 13.7V / 27.4V / 41.1V / 54.8V
Charging
Set Points Absorption Stage 14.4V / 28.8V / 43.2V / 57.6V
AGM
(Default) Float Stage 13.7V / 27.4V / 41.1V / 54.8V
Back panel description
Over-charging Voltage 15.5V / 30.0V / 45.0V / 60.0V

80A Over-charging Comeback Voltage 14.5V / 29.5V / 44.5V / 59.0V

Battery Defect Voltage 10.0V / 17.0V / 25.5V / 34.0V

Temperature Compensation Conefficient -5mv / ℃ /cell (25℃ vef)

Peak Conversion Efficiency 98% (MPPT Efficiency 99%)

Maximum Battery Current 60A 80A 100A


1. The load positive terminal
2. Battery connectors Maximum DC load current / / 100A
4 2 5 7 6
3. The load negative terminal 60amps continuous 80amps continuous 100amps continuous
Max Charging Current
4. PV connectors @ 40℃ ambient @ 40℃ ambient @ 40℃ ambient
100A 5. Communication port
DISPLAY & PROTECTION
6. Battery temperature sensor terminal
Solar high voltage disconnect/ Solar high voltage reconnect/ Battery high voltage disconnect
7. USB port Protections
Battery high voltage reconnect/ High temperature disconnect/ High temperature reconnect

MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 306.6*163.6*94.9mm 284*165*97mm

1 2 3 4 5 6
Package Dimension (W*H*D) / /

G.W 3kg 4kg

Solar system connection N.W / /

OTHER

Mounting Wall mount


PV input Environmental Rating Indoor
TV Laptop Lighting Fans

Solar Panel Enclosure IP20

Radiating Mode Fan cooling

Operation Temperature Range -10~55℃


MPPT solar charge
controller
Ambient Humidity 0~90% relative humidity (non-condensing)
AC Input

Inverter Utility Altiude ≤3000m

BAT input CERTIFICATION & STANDARDS

Generator UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)


CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010)

122
Products / Controller

MPPT SOLAR CHARGE CONTROLLER MODEL PC18-6025F PC18-8025F PC18-10025F

PC1800F Series Nominal Battery System Voltage

CONTROLLER INPUT
12V / 24V / 48VDC (Auto detection); 36V (Setting)

Battery Voltage 12V / 24V / 36V / 48V


60~100A | 12V,24V | 245V 12V (VBAT) 100V

MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an Maximum Solar Input 24V (VBAT) 245V
efficient, safe, multi-stage recharging process that prolongs battery life and Voltage 36V (VBAT) 245V
assures peak performance from a solar array. Each Charge Controller allows
customized battery recharging. 48V (VBAT) 245V

12V (VBAT) 15-95V

PV Array MPPT Voltage 24V (VBAT) 30~230V


Range 36V (VBAT) 45~230V
■ LCD display , easy to operate on LCD screen 48V (VBAT) 60~230V
■ Multi stage charging 12V (VBAT) 940W 1250W 1560W
(3-stage charging , parallel charging and equalized charging function)
24V (VBAT) 1880W 2500W 3120W
■ Maximum Solar Input Voltage: 245V Maximum Input Power
36V (VBAT) 2820W 3750W 4680W
■ BTS – Battery remote temperature sensor terminal
48V (VBAT) 3760W 5000W 6250W
■ Enable to charge Li-thium, Gel , lead-acid battery
BATTERY
■ With RS485 & USB communication port
Flooded Absorption Stage 14.2V / 28.4V / 42.6V / 56.8V
■ Protection: PV array short circuit, PV reverse polarity, Battery reverse polarity,
Over charging, Output short circuit Battery Float Stage 13.7V / 27.4V / 41.1V / 54.8V
Charging
Set Points Absorption Stage 14.4V / 28.8V / 43.2V / 57.6V
AGM
(Default) Float Stage 13.7V / 27.4V / 41.1V / 54.8V
Back panel description
Over-charging Voltage 15.5V / 30.0V / 45.0V / 60.0V

80A Over-charging Comeback Voltage 14.5V / 29.5V / 44.5V / 59.0V

Battery Defect Voltage 10.0V / 17.0V / 25.5V / 34.0V

Temperature Compensation Conefficient -5mv / ℃ /cell (25℃ vef)

Peak Conversion Efficiency 98% (MPPT Efficiency 99%)

Maximum Battery Current 60A 80A 100A


1. The load positive terminal
2. Battery connectors Maximum DC load current / / 100A
4 2 5 7 6
3. The load negative terminal 60amps continuous 80amps continuous 100amps continuous
Max Charging Current
4. PV connectors @ 40℃ ambient @ 40℃ ambient @ 40℃ ambient
100A 5. Communication port
DISPLAY & PROTECTION
6. Battery temperature sensor terminal
Solar high voltage disconnect/ Solar high voltage reconnect/ Battery high voltage disconnect
7. USB port Protections
Battery high voltage reconnect/ High temperature disconnect/ High temperature reconnect

MECHANICAL SPECIFICATIONS

Machine Dimension (W*H*D) 306.6*163.6*94.9mm 284*165*97mm

1 2 3 4 5 6
Package Dimension (W*H*D) / /

G.W 3kg 4kg

Solar system connection N.W / /

OTHER

Mounting Wall mount


PV input Environmental Rating Indoor
TV Laptop Lighting Fans

Solar Panel Enclosure IP20

Radiating Mode Fan cooling

Operation Temperature Range -10~55℃


MPPT solar charge
controller
Ambient Humidity 0~90% relative humidity (non-condensing)
AC Input

Inverter Utility Altiude ≤3000m

BAT input CERTIFICATION & STANDARDS

Generator UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)


CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010)

124
Products / Controller

MPPT SOLAR CHARGE CONTROLLER


MODEL PC18-3015A PC18-4015A

PC1800A Series Nominal Battery System Voltage 12V / 24V (Auto detection)

CONTROLLER INPUT
30A, 40A | 12V,24V
Battery Voltage 12V/ 24V
This solar charge controller is an advanced solar charger with maximum power
point tracking. Applying intelligent MPPT algorithm, it allows solar charge Open circuit voltage 145V
controller to extract maximum power from solar arrays by finding the maximum
power point of the array. PV Array MPPT Voltage Range 60-130VDC
The MPPT battery charging process has been optimized for long battery life
12V 432W 576W
and improved system performance. Self-diagnostics and electronic error
Maximum Input Power
protections prevent damage when installation errors or system faults occur.
24V 864W 1152W

BATTERY

Absorption Stage 14.2V/28.4V


Flooded Battery
■ Intelligent Maximum Power Point Tracking technology increases efficiency 25%~30%
Float Stage 13.7V/27.4V
Charging
■ Compatible for PV systems in 12V,or24V
Set Points
Absorption Stage 14.4V/28.8V
■ Three-stage charging optizes battery performance AGM/GEL/LEAD
(Default)
■ Maximum charging current up to 30A/40A Float Stage 13.7V/27.4V

■ Advanced MPPT technology,with efficient no less than 99% Over-charging Voltage 15.5V / 30.0V
■ Maximum DC- DC conversion efficiency of 98%
Over-charging Comeback Voltage 14.5V / 29.5V
■ Battery temperature sensor(BTS) automatically provides temperature
compensation Automatic battery voltage detection Battery Defect Voltage 10.0V / 17.0V
■ Integrated intelligent slot compatible with 485 communication
Temperature Compensation Coefficient -5mv / ℃ /cell (25℃ vef)

Peak Conversion Efficiency 98% (MPPT Efficiency 99%)

Back panel description Maximum Battery Current 30A 40A

30amps continuous @ 40℃ 40amps continuous @ 40℃


Max Charging Current
ambient ambient

GENERAL SPECIFICATION
1. LCD Display
2. Charging Indicator Radiating Mode Automatic cooling
3. Fault and waming indicator
4. Wiring fault indicator Solar high voltage disconnect/ Solar high voltage reconnect/ Battery high voltage disconnect
Protections
Battery high voltage reconnect/ High temperature disconnect/ High temperature reconnect
5. Operation button
6. PV connectors MECHANICAL SPECIFICATIONS
1
3 7. Battery connectors
4 Mounting Wall mount
2 8. Load connectors
5
9. Battery temperature sensor terminal Machine Dimension (W*H*D) 187*255*72mm
10. RS485 communication port
9 6 7 8 10
Package Dimension (W*H*D) /

G.W /

Solar system connection N.W /

OTHER

Environmental Rating Indoor


PV input
TV Laptop Lighting Fans

Solar Panel
Enclosure IP30

Operation Temperature Range -10~50℃

MPPT solar charge Ambient Humidity 0~90% relative humidity (non-condensing)


controller
AC Input
Altiude ≤3000m
Inverter Utility

CERTIFICATION & STANDARDS


BAT input

Generator
UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)
CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010)

126
Products / Controller

MPPT SOLAR CHARGE CONTROLLER MODEL PC16-2015A PC16-3015A PC16-4015A

PC1600A Series Nominal Battery System Voltage 12VDC / 24VDC (Auto Detection)
CONTROLLER INPUT

PV Open Circuit 12V 100VDC


20A, 30A, 40A | 12V,24V Voltage 24V 145VDC

MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an PV Array MPPT 12V 16VDC~100VDC
efficient, safe, multi-stage recharging process that prolongs battery life and Voltage Range 24V 32VDC~130VDC
assures peak performance from a solar array. Each Charge Controller allows
Max 12V 300W 450W 600W
customized battery recharging.
PV Input Power 24V 600W 900W 1200W
BATTERY

Absorption 12V 12.5VDC


Voltage 24V 25.0VDC
■ LCD display , easy to operate on LCD screen 12V 13.7VDC
Refloat Voltage
■ Multi stage charging 24V 27.4VDC
(3-stage charging , parallel charging and equalized charging function)
12V 14.3VDC
■ BTS – Battery remote temperature sensor terminal Float Voltage
24V 28.6VDC
■ Enable to charge Li-thium, Gel , lead-acid battery
Low Voltage 12V 10.0VDC
■ With RS485 & USB communication port Protection Point 24V 20.0VDC
■ Protection: PV array short circuit, PV reverse polarity,
DC OUTPUT
Battery reverse polarity, Over charging, Output short circuit
12V 10.0~14.5VDC
Output Voltage
24V 20.0~29.0VDC
Peak Conversion Efficiency 98%(MPPT Efficiency 99%)
Max Charging Current 20 amps continuous 30 amps continuous 40 amps continuous
Max Output Current 20 amps continuous 20 amps continuous 20 amps continuous
Back panel description 12V 10.25VDC
Low Voltage
alarm 24V 20.5VDC
1. LCD Display Low Voltage 12V 10.0VDC
2. LED Indicator cut off 24V 20.0 VDC
3. Confirm the selection in setting mode
Low Voltage 12V 11.0VDC
4. Decrease the setting data
Recovery 24V 22.0VDC
14 13 7 8 9 10 11 12 5. Increase the setting data
6. Enter or exit setting mode DISPLAY & PROTECTION
7. The load negative terminal Systematic operation, LV indication, LV protection, Over charge protection
1 LED Indication
8. The load positive terminal Loads protection, Short circuit protection

2
9. The battery negative terminal LED Display Charge Voltage, Charge Current, Voltage of storage battery, Capacity of storage battery, Output current
10. The battery positive terminal
PV array short circuit, PV reverse polarity
6 3 11. PV array negative terminal
Battery reverse polarity, Over charging protrction
5 4 12. PV array positive terminal Alarm Protections
13. Communication network terminal Output short circuit protection

14. Remote external temerature terminal Low voltage protection for storage battery
MECHANICAL SPECIFICATIONS

Solar system connection Mounting Wall mount


Machine Dimension (W*H*D) 154*236*88mm
Package Dimension (W*H*D) / / /
G.W /
PV input
TV Laptop Lighting Fans N.W / / /
Solar Panel
OTHER
Environmental Rating Indoor

MPPT solar charge Radiating Mode Automatic cooling


controller
AC Input Operation Temperature Range 0℃ ~ 55℃
Inverter Utility Loading (20GP/40GP/40HQ) 2500pcs / 5000pcs / 5800pcs

BAT input CERTIFICATION & STANDARDS

Generator UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)


CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010)

128
Products / Controller

MPPT SOLAR CHARGE CONTROLLER MODEL PC18-6015A PC18-8015A

PC1800A Series Nominal Battery System Voltage 12V / 24V / 48VDC (Auto detection); 36V (Setting)

ELECTRICAL SPECIFICATIONS

Maximum Battery Current 60Amps 80Amps


60A,80A | 12V,24V,48V
Battery Voltage 12V/ 24V/ 36V/ 48V
MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an
efficient, safe, multi-stage recharging process that prolongs battery life and 12V (VBAT) 100V
assures peak performance from a solar array. Each Charge Controller allows
customized battery recharging. 24V (VBAT) 145V
Maximum Solar Input Voltage
36V (VBAT) 145V

48V (VBAT) 145V

12V (VBAT) 15~95V


■ LCD display , easy to operate on LCD screen
24V (VBAT) 30~130V
■ Multi stage charging PV Array MPPT Voltage Range
(3-stage charging , parallel charging and equalized charging function) 36V (VBAT) 45~130V
■ BTS – Battery remote temperature sensor terminal
48V (VBAT) 60~130V
■ Enable to charge Li-thium, Gel , lead-acid battery
12V (VBAT) 940W 1250W
■ With RS485 & USB communication port
24V (VBAT) 1880W 2500W
■ Protection: PV array short circuit, PV reverse polarity,
Maximum Input Power
Battery reverse polarity, Over charging, Output short circuit
36V (VBAT) 2820W 3750W

48V (VBAT) 3760W 5000W

Solar high voltage disconnect; Solar high voltage reconnect; Battery high voltage disconnect;
Protections
Battery high voltage reconnect; High temperature disconnect;High temperature reconnect

Back panel description BATTERY CHARGING

Charging Algorithm 3-Step or 4-Step (Li)

Temperature Compensation Coefficient -5mV / ℃ / cell (25℃ ref.)

Temperature Compensation Set Points Absorption, Float


1
2 Absorption Stage 14.2V/ 28.4V/ 42.6V/ 56.8V
3 Flooded Battery
4 Float Stage 13.7V/ 27.4V/ 41.1V/ 54.8V
Charging
Set Points
5 Absorption Stage 14.4V/ 28.8V/ 43.2V/ 57.6V
AGM/ GEL/ LEAD
10 11 8
9 6 7 Battery (Default)
Float Stage 13.7V/ 27.4V/ 41.1V/ 54.8V
1. LCD display 6. PV connextors
Over-charging Voltage 15.5V / 30.0V / 45.0V / 60.0V
2. Power ON/Charging indicator 7. Battery connectors
3. Fault and warning indicator 8. Battery temperature sensor terminal Over-charging Comeback Voltage 14.5V / 29.5V / 44.5V / 59.0V
4. Wiring fault indicator 9. Wiring box cover
Battery Defect Voltage 10.0V / 17.0V / 25.5V / 34.0V
5. Operation button 10. RS485 communication port
11. USB MECHANICAL & ENVIRONMENT

Machine Dimension (W*H*D) 315*160*135mm


Solar system connection
Package Dimension (W*H*D) /

G.W /

PV input N.W /
TV Laptop Lighting Fans

Solar Panel Ambient Temperature Range -10℃ to 55℃

Storage Temperature -40℃ to 75℃

MPPT solar charge Humidity 0%~90% RH (No condensing)


controller
AC Input
Enclosure IP20
Inverter Utility

CERTIFICATION & STANDARDS


BAT input

Generator
UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)
CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010)