Solar Inverter Catalog
Solar Inverter Catalog
The technical specifications of this document are subject to change without any notice
120V/230V
Why Choose MUST? Complete Power Solution
Committed to providing one-stop power solution, including power generation, power conversion, storage, monitoring & management
MUST Renewable and accessories.
We are proud to have been manufacturing portable power stations, LiFePO4 batteries, inverters, UPS, and solar charge controllers
since 1998, with a team of 500 dedicated employees.
MUST integrates the latest and most advanced technology and automation solutions, owning the most complete product line in the HYBRID ON GRID
LITHIUM BATTERY POWER INVERTER
industry with reliable quality, high efficiency and stable performance. SOLAR INVERTER INVERTER
20+ 120+
Plants Employees
35,000m 2
500+
R&D Staffs Overseas Service Center
100+ 6
ALL-IN-ONE
SYSTEM
OFF GRID
SOLAR INVERTER
Intelligent Comprehensive
Lean production
Manufacturing Professional Test
Automatic integrated production line, automatic SMT production line and automatic and digital quality control andmanagement of
manufacturing key sections: online AOI inspection, FCT, ATE, Aging test. R&D tests includes lslanding detection etc.
2
Products / 230V
230V Series
Off Grid Solar Inverter/ On/Off Grid Hybrid Solar Inverter/ Grid-Tie Solar Inverter/ Off Grid Power Inverter
4
Products / 230V
SIMULATED SINE WAVE SOLAR INVERTER MODEL PV11-1200 Plus PV11-2400 Plus
NVERTER OUTPUT
■ Built-in 50A PWM Solar Charge Controller Typical Transfer Time Typical 15~20ms 40ms max
■ AC/solar priority for output via MFD Selectable Voltage Narrow 170~280VAC
Range Wide 90~280VAC
■ AC/solar priority for charging via MFD
MECHANICAL SPECIFICATIONS
6
Products / 230V
HIGH FREQUENCY OFF GRID SOLAR INVERTER MODEL PV15-1012 PV15-1512 PV15-2024
It is a cost effective, intelligent solar inverter which accepts Solar & Utility input Nominal Output Voltage RMS 230V
at the same time. The comprehensive LCD display offers user- configurable and Output Voltage Regulation +10/-18%
easy-accessible button adjustment such as battery charging current, AC/solar
charger priority and DC priority.When battery voltage is low,it will automatically Output Frequency 50Hz / 60Hz ± 1Hz
switch to AC grid to supply continuous power to the loads. Inverter Efficiency (Peak) >90%
Line Mode Efficiency >95%
■ Built-in 45A MPPT Solar Charge Controller
■ 15A@24V, 20A@12V standard charging current from utility AC Typical Transfer Time Typical < 10ms , 20ms max
■ AC/solar priority for charging via MFD AC INPUT
■ Different charging mode for different kinds of batteries Voltage 230VAC
■ Overload & short-circuit protection, Battery reverse polarity protection,
Deep discharge protection Voltage Range 170~280VAC (UPS) / 90~280VAC (APL) / 184~258VAC (VDE)
■ Auto restart while AC/solar is recovering Adjustable solar and utility Frequency Range 50Hz/ 60Hz (auto sensing)
charging current
BATTERY
■ Support two kinds of batteries include LiFePO4 Lithium Battery Pack
and Lead-acid Battery. Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack - 12V(4 Series) 24V(8 Series)
■ Support one key battery type fast setting Nominal Input Voltage 12VDC 12VDC 24VDC
■ Automatic activate protected lithium battery pack by Utility AC.
Low Battery Cutoff 10.5VDC(PB) 11.5VDC(LI) 10.5VDC(PB) 11.5VDC(LI) 21.0VDC(PB) 23.0VDC(LI)
■ Automatic activate protected lithium battery pack by Solar PV
Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)
■ Low shutdown loss for energy storage system application
Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)
High Battery Voltage Recover 14.5VDC(PB) 14.5VDC(LI) 14.5VDC(PB) 14.5VDC(LI) 29.0VDC(PB) 29.0VDC(LI)
Back panel description
High Battery Voltage Cutoff 15.0VDC(PB) 15.0VDC(LI) 15.0VDC(PB) 15.0VDC(LI) 30.0VDC(PB) 30.0VDC(LI)
5. Power switch
6. External battery connectors Maximum Efficiency > 95%
7. FAN AC Charging Current 10A/20A (Can be set) 10A/20A (Can be set) 7A/15A (Can be set)
8. Solar panel terminal
Maximum Charge Current AC+PV 10~65A (Can be set) 10~65A (Can be set) 10~60A (Can be set)
9. Input circuit breaker (plastic case)
BYPASS & PROTECTION
10. AC input
2 3 4 5 6 7 8 9 10 Overload Protection (SMPS Load) FUSE
Output Short Circuit Protection FUSE
Bypass Fuse Rating 7A 10A 10A
Max Bypass Current 7A 10A 10A
Material selection Solar system connection
MECHANICAL SPECIFICATIONS
Machine Dimension (W*H*D) 235*290*92mm 224*337*98mm 235*290*92mm
Metal case Plastic case Package Dimension (W*H*D) 595*375*315mm 300*410*178mm 595*375*315mm
N.W (kg) 2.8kg 3.6kg 3.0kg
PV input
G.W (kg) 3.5kg 4.3kg 3.7kg
Solar Panel Load Material Plastic case Metal case Plastic case
OTHER
Operation Temperature Range 0℃ to 40℃
AC Input BAT input
Audible Noise 50dB MAX
Utility Battery
Display LED+LCD
Inverter
CERTIFICATION & STANDARDS
PV15-1512 PV15-1012/ PV15-2024 CE
8
Products / 230V
HIGH FREQUENCY SOLAR INVERTER PV18-1612 PV18-2524 PV18-3024 PV18-3524 PV18-5548 PV18-6248
MODEL
PV1800 ECO Series ECO ECO ECO ECO ECO ECO
Default Battery System Voltage 12VDC 24VDC 24VDC 24VDC 48VDC 48VDC
INVERTER OUTPUT
1.6~6.2KW | Dual output
Rated Power 2000VA/1600W 2500VA/2500W 3000VA/3000W 3500VA/3500W 5500VA/5500W 6200VA/6200W
PV1800 ECO is a multi-function inverter/charger, combining functions of
inverter, MPPT solar charger and battery charger to offer uninterruptible power Output Channel Dual Dual Dual Dual Dual Dual
support in portable size. PV1800 ECO Series can run without battery.
The Maximum PV input voltage can reach 400V/450V/500V, which can help Surge Power 3200W 5000W 6000W 7000W 11000W 12400W
customers make full use of solar energy.(For 1.6~6.2KW)
Waveform Pure sine wave
Back panel description Overcharge Protection 15VDC 30VDC 30VDC 30VDC 60VDC 60VDC
PV Array MPPT Voltage Range(Typ.) 30~320VDC 30~320VDC 30~320VDC 60~360VDC 60~360VDC 120~450VDC
Maximum Solar Charge Current 80A 100A 100A 100A 100A 120A
1. Ground 6. PV input
Maximum AC Charge Current 80A 60A 60A 60A 100A 100A
2. AC Input 7. ON/OFF Switch
3. AC Output1 8. RS-485/CAN Communication port Maximum Charge Current 80A 100A 100A 100A 100A 120A
4. AC Output2 9. Dry Contact
MECHANICAL SPECIFICATIONS
5. Battery Input 10. WiFi port
367*290*111 367*290*111 367*290*111 367*318*122.5 454*318*122.5 428*318*140
Machine Dimension (W*H*D)
mm mm mm mm mm mm
446*394*187 446*394*187 446*394*187 446*410*200 544.5*410*210 550*400*220
Solar system connection Package Dimension (W*H*D)
mm mm mm mm mm mm
AC Input
Humidity 5% to 95% Relativ Humidity (Non-condensing)
BAT input
Second Load Storage Temperature -15°C -60°C
10
Products / 230V
INVERTER OUTPUT
2~3.2KW | 400V | WiFi
Rated Power 2000VA / 2000W 3200VA / 3200W
PV1800 PRO is a multi-function inverter/charger, combining functions of Surge Power 4000W 6400W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV1800 PRO Series can run without battery. The Waveform Pure sine wave
Maximum PV array open circuit voltage can reach 400V and MPPT voltage is
60~320Vdc, which Can help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
N.W (kg) /
G.W (kg) /
PV input
TV Fridge Lighting Fans
OTHER
Solar Panel
MECHANICAL SPECIFICATIONS
Inverter
Generator Battery CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
12
Products / 230V
INVERTER OUTPUT
3~5.2KW | 450V | WiFi | 9pcs parallel Rated Power 3000VA / 3000W 5200VA / 5200W
PV1800 PRO is a multi-function inverter/charger, combining functions of Surge Power 6000W 10400W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV1800 PRO Series can run without battery. Waveform Pure sine wave
The Maximum PV array open circuit voltage can reach 450V and MPPT voltage
is 150~430Vdc, which Can help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
Voltage 230VAC±5%
■ Built-in MPPT solar charge controller
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
■ MAX PV Array Open Circuit Voltage: 450V
■ Combining solar system, AC utility, and battery power source to supply Frequency Range 50Hz / 60Hz(Auto sensing)
continuous power
BATTERY
■ Overload, short circuit and Deep discharge protection
■ Support USB, RS485 monitoring function Floating Charge Voltage 27.4VDC 54.8VDC
■ Parallel operation with up to 9 units
Overcharge Protection 30VDC 60VDC
■ WIFI remote monitoring (optional)
SOLAR CHARGER & AC CHARGER
1 2 3 7 8 9 10 11 12 1. AC Input Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
2. AC Output
Maximum PV Array Power 4000W 5000W 6000W
3. PV Input
4. Power On/Off Switch PV Array MPPT Voltage Range 150~430 VDC
6 5 4 5. Battery Input
6. Circuit breaker Maximum Solar Charge Current 80A 100A 80A 100A
7. Dry Contact
5KW Maximum AC Charge Current 60A 80A 60A 80A
1 2 9 8 7 3 4 12 8. USB port
9. RS-485/CAN Communication port Maximum Charge Current 80A 100A 80A 100A
10. Parallel switch (only for parallel model)
MECHANICAL SPECIFICATIONS
11. Parallel communication port
(only for parallel model)
Machine Dimension (W*H*D) 322*486*134mm 309*505*147mm
12. USB WiFi port
6 10 11 5
Package Dimension (W*H*D) 575*229*425mm 603*260*400mm
OTHER
PV input
TV Fridge Lighting Fans
Humidity 5% to 95% Relative humidity (Non-condensing)
Solar Panel
Utility
CERTIFICATION & STANDARDS
BAT input
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2020+A11:2020
EN IEC62368-1:2018
Inverter
Generator Battery Rohs-(2011/65/EUand2015/863/EU)
14
Products / 230V
INVERTER OUTPUT
8~10KW | 450V | WiFi
Rated Power 8000W 10000W
This is a multi-function inverter/charger, combining functions of inverter, Surge Power 16000W 20000W
solar charger and battery charger to offer uninterruptible power support with
portable size. Its comprehensive LCD display offers user-configurable and easy- Waveform Pure Sine Wave
accessible button operation such as battery charging current, AC/solar charger
priority, and acceptable input voltage based on different applications. AC Voltage Regulation (Batt.Mode) 230VAC±5%
■ Pure sine wave output Transfer Time 10ms (UPS) 20ms (APL)
■ Combining solar system, AC utility, and battery power source to supply
continuous power AC INPUT
■ Configurable battery charging current based on applications via LCD setting Nominal Input Voltage 230VAC
■ Configurable AC/Solar Charger priority via LCD setting
Max AC Input Voltage 300VAC
■ Compatible to mains voltage or generator power
Selectable Voltage Range 170~280VAC (UPS) / 90~280VAC (APL) / 184~253VAC(VDE4105)
■ Auto restart while AC is recovering
■ Overload/ Over temperature/ short circuit protection Frequency Range 50Hz / 60Hz(Auto detection)
5. PV input
Solar Charging Current 80A/80A 100A/100A
6. COM2
7. BMS communication Default Charging Current 80A/80A
8. Battery input
14 Maximum Charge Current 160A 200A
9. Power on/off switch
10. PV input Charging Algorithm 3-step (Flooded Battery / AGM / GEL/ LEAD Battery), 4-step(LI)
11. COM1
12. USB MECHANICAL SPECIFICATIONS
13. Dry contact
Machine Dimension (W*H*D) 600*503*141.2mm
14. WiFi port
Package Dimension (W*H*D) /
G.W (kg) /
PV2 input
Operating Temperature -10°C~50°C
Solar Panel
16
Products / 230V
INVERTER OUTPUT
1~5KW | PWM 50A/60A | WiFi
Rated Power 1000W 2000W 3000W 4000W 5000W
PV1800 VPK is a multi-function inverter/charger, combining functions of
inverter, PWM solar charger and battery charger to offer uninterruptible Surge Power 2000W 4000W 6000W 8000W 10000W
power support with portable size. Its comprehensive LCD display offers user-
configurable easy-accessible button operation such as battery charging current, Waveform Pure sine wave
AC/solar charger priority, and acceptable input voltage based on different
applications. AC Voltage Regulation (Batt.Mode) (220VAC~240VAC)±5%
■ Compatible to generator
Floating Charge Voltage 13.7VDC 27.4VDC 54.8VDC
1KW
SOLAR CHARGER & AC CHARGER
G.W (kg) / / /
OTHER
PV input
TV Fridge Lighting Fans
Humidity 5% to 95% Relative humidity (Non-condensing)
Solar Panel
18
Products / 230V
INVERTER OUTPUT
2~5.5KW | MPPT 80A | PV 145V
Rated Power 2000W 3000W 3000W 4000W 5000W 5500W
PV1800 VHM is a multi-functional inverter/charger, combining functions of Surge Power 4000W 6000W 6000W 8000W 10000W 11000W
inverter, solar charger and battery charger to offer uninterruptible power
support in portable size. Its comprehensive LCD display offers user-configurable Waveform Pure Sine Wave
and easy-accessible button operation such as battery charging current,
AC/solar charger priority, and acceptable input voltage based on different AC Voltage Regulation (Batt.Mode) (220VAC~240VAC)±5%
applications.
Inverter Efficiency(Peak) 93%
AC INPUT
■ Rated power : 2KW -5.5KW
■ Pure sine wave solar inverter Voltage 230VAC
■ Output power factor 1
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE4105)
■ Built-in 80A MPPT solar charger
■ Built-in anti-dust kit for harsh environment Frequency Range 50Hz / 60Hz(Auto sensing)
■ Support parallel operation up to 3 units (available for 3KW-5.5KW 48V)
BATTERY
■ WIFI remote monitoring (optional)
■ Compatible to generator Normal Voltage 24VDC 48VDC
N.W (kg) / /
PV input
G.W (kg) / /
TV Fridge Lighting Fans
OTHER
Solar Panel
20
Products / 230V
HIGH FREQUENCY SOLAR INVERTER MODEL PV18-3048 VHM PV18-4048 VHM PV18-5048 VHM PV18-5548 VHM
INVERTER OUTPUT
3~5.5KW | MPPT 80A | PV 250V
Rated Power 3000W 4000W 5000W 5500W
PV1800 VHM is a multi-functional inverter/charger, combining functions of Surge Power 6000W 8000W 10000W 11000W
inverter, solar charger and battery charger to offer uninterruptible power
support in portable size. Its comprehensive LCD display offers user-configurable Waveform Pure Sine Wave
and easy-accessible button operation such as battery charging current,
AC/solar charger priority, and acceptable input voltage based on different AC Voltage Regulation (Batt.Mode) (220VAC~240VAC)±5%
applications.
Inverter Efficiency(Peak) 93%
AC INPUT
■ Rated power : 3KW -5.5KW
■ Pure sine wave solar inverter Voltage 230VAC
■ Max PV Array Open Circuit Voltage: 250V
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE4105)
■ Output power factor 1
■ Built-in 80A MPPT solar charger Frequency Range 50Hz / 60Hz(Auto sensing)
■ Support parallel operation up to 3 units
BATTERY
■ Communication CAN/485 port for BMS (optional)
■ PV lithium battery activation function Normal Voltage 48VDC
■ WIFI remote monitoring (optional)
Floating Charge Voltage 54.8VDC
■ Compatible to generator
Overcharge Protection 60VDC
1 2 3 4 6 5
PV Array MPPT Voltage Range 60~200VDC
1. AC input
2. AC output Standby Power Consumption 2W
3. Circuit breaker
4. Battery input PV Input Power (STC) 4500W
5. PV input
Maximum Solar Charge Current 80A
6. Power on/off switch
7. RS-485 Communication port Maximum Effciency 98%
7 8 9 11 12 10 8. USB
9. Dry contact Maximum AC Charge Current 60A
10. USB wifi port
Maximum Charge Current 140A
11. Parallel switch (only for parallel model)
12. Parallel communication port (only for parallel model) MECHANICAL SPECIFICATIONS
N.W (kg) /
G.W (kg) /
PV input
TV Fridge Lighting Fans
OTHER
Solar Panel
22
Products / 230V
INVERTER OUTPUT
1.6-5.5KW | Dual output | WiFi
Rated Power (Main+Second Load) 2000VA/1600W 2500VA/2500W 3000VA/3000W 3500VA/3500W 5500VA/5500W
PV1800 PREM is a multi-function inverter/charger, combining functions of Surge Power 3200W 5000W 6000W 7000W 11000W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV1800 PREM Series can run without battery. Waveform Pure sine wave
The Maximum PV array open circuit voltage can reach 400V/450V. which Can
help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
1 2 4 8 9 10 11
Maximum PV Input Current 16A 18A 18A 18A 28A
1. AC Input Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
2. Main Load
3. Second Load Maximum PV Array Power 2000W 4000W 4000W 4000W 6000W
4. PV Input
PV Array MPPT Voltage Range(Typ.) 30~320VDC 60~360VDC
7 3 6 5
5. ON/OFF Switch
6. DC Input Maximum Solar Charge Current 80A 100A
5.5KW
7. Ground
1 2 3 4 8 9 10 11
8. WiFi antenna Maximum AC Charge Current 80A 60A 60A 60A 100A
9. USB Port
Maximum Charge Current 80A 100A
10. RS-485/CAN Communication port
11. Dry contact MECHANICAL SPECIFICATIONS
Solar system connection Package Dimension (W*H*D) 446*394*187mm 446*394*187mm 446*394*187mm 459*410*200mm 544.5*410*200mm
AC Input
Humidity 5% to 95% Relative humidity (Non-condensing)
24
Products / 230V
HIGH FREQUENCY SOLAR INVERTER PV18-1012 PV18-1512 PV18-1224 PV18-2224 PV18-3224 PV18-3524 PV18-4024
MODEL
PV1800 VPM ll Series
VPM ll VPM II VPM ll VPM ll VPM ll VPM ll VPM ll
Default Battery System Voltage 12VDC 12VDC 24VDC 24VDC 24VDC 24VDC 24VDC
INVERTER OUTPUT
1~4KW | 24V | 40~60A
Rated Power 1000VA/1000W 1500VA/1500W 1200VA/1200W 2200VA/2200W 3200VA/3200W 3500VA/3500W 4000VA/4000W
This is a multi-function inverter/charger, combining functions of inverter,
MPPT 40A/60A solar charger and battery charger to offer uninterruptible Surge Power 2000VA 3000VA 2400VA 4400VA 6400VA 7000VA 8000VA
power support with portable size. Its comprehensive LCD display offers user-
configurable and easy-accessible button operation such as battery charging Waveform Pure sine wave
current, AC/solar charger priority, and acceptable input voltage based on AC Voltage Regulation (Batt.
different applications. 230VAC
Mode)
AC INPUT
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
Voltage 230VAC
■ Bult in MPPT 40A/60A solar charge controller
■ Combining solar system, AC utility, and battery power source to Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
supply continuous power
Frequency Range 50Hz / 60Hz (Auto sensing)
■ Overload, short circuit and Deep discharge protection
2. AC input
Maximum PV Array Power 600W 720W 1000W 1600W 1600W 1600W 1600W
3. Circuit breaker
4. PV input Maximum Solar Charge Current 45A 60A 40A 60A 60A 60A 60A
5. Battery input
Maximum Efficiency 98%
6. Power on/off switch
3.5KW/4KW
7. Dry contact
Maximum AC Charge Current 20A 20A 30A 40A 60A 60A 60A
3 2 1 11 5 4 6 7 8 9 10 8. USB Communication port
9. RS-485,CAN Communication port Maximum Charge Current 65A 70A 70A 100A 120A 120A 120A
10. USB WiFi port (optional)
MECHANICAL SPECIFICATIONS
11. Ground
Machine Dimension (W*H*D)
224*337*98 255*318*110 224*337*98 367.4*254.5*103 367.4*254.5*103 367.4*318*121 367.4*318*121
(mm)
Package Dimension (W*H*D)
300*410*178 355*402*206 299*292*184 436*331*189 436*331*189 549*410*200 549*410*200
Solar system connection (mm)
PV input
G.W (kg) 4.3 6.0 5.5 6.5 6.5 7.2 7.2
TV Fridge Lighting Fans
OTHER
Solar Panel
Inverter
Generator Battery CE-EMC+LVD(EN6100-6-3, EN6100-6-1+EN IEC62109-1, EN IEC62109-2)
26
Products / 230V
INVERTER OUTPUT
2.5~3KW | 24V | 40~60A
Rated Power 2500VA / 2000W 3000VA / 2500W
This is a multi-function inverter/charger, combining functions of inverter, MPPT
60A solar charger and battery charger to offer uninterruptible power support Surge Power 5000VA 6000VA
with portable size. Its comprehensive LCD display offers user-configurable and
easy-accessible button operation such as battery charging current, AC/solar Waveform Pure sine wave
charger priority, and acceptable input voltage based on different applications.
AC Voltage Regulation (Batt.Mode) 220VAC~240VAC(Setting)
AC INPUT
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
■ Overload, short circuit and Deep discharge protection Frequency Range 50Hz / 60Hz (Auto sensing)
■ Cold start function
BATTERY
■ Support USB, RS485, CAN monitoring function
■ Compatible to generator
Floating Charge Voltage 27.4VDC
MECHANICAL SPECIFICATIONS
Utility
Humidity 5% to 95% Relativ Humidity (Non-condensing)
BAT input
Generator
Inverter
Battery Storage Temperature -15°C -60°C
28
Products / 230V
INVERTER OUTPUT
4~6KW | 500V | 100~120A | Dual output | WiFi | 9pcs parallel
Rated Power 4000VA / 4000W 6000VA / 6000W
PV1900 EXP is a multi-function inverter/charger, combining functions of
inverter, MPPT solar charger and battery charger to offer uninterruptible power Surge Power 8000W 12000W
support in portable size. PV1900 EXP Series can run without battery.
Waveform Pure sine wave
The Maximum PV array open circuit voltage can reach 500V and MPPT voltage
is 150~450Vdc, which Can help customers make full use of solar energy.
AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
OTHER
PV input
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Fridge Lighting Fans
Solar Panel
Operating Temperature 0°C~50°C
Main Load
AC Input Storage Temperature -15°C -60°C
Utility
CERTIFICATION & STANDARDS
Second Load
BAT input
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
TV Air conditioner Washing machine EN IEC62368-1:2020+A11:2020
Inverter CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
Generator Battery
EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011
30
Products / 230V
INVERTER OUTPUT
6.2~12KW | PV500V | 120A~150A | Dual input | Dual output
Rated Power 6200VA/6200W 8000VA/8000W 10000VA/10000W 12000VA/12000W
PV1900M EXP is a multi-function inverter/charger, combining functions of
Surge Power 12400W 16000W 20000W 24000W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PV1900M EXP Series can run without battery. Waveform Pure sine wave
The Maximum PV input voltage can reach 500V and MPPT voltage range
is 90~450Vdc, built-in two MPPTs solar charge controller, which can help AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
customers make full use of solar energy.
Inverter Efficiency(Peak) 92%
AC INPUT
Back panel description Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
OTHER
PV1 input
Solar Panel
Fridge Lighting Fans
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Main Load
PV2 input Operating Temperature 0°C~50°C
Solar Panel Second Load
Storage Temperature -15°C -60°C
TV Air conditioner Washing machine
BAT input
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
AC Input 2
EN IEC62368-1:2020+A11:2020
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
Generator Inverter (8~12K) Battery
EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011
32
Products / 230V
LOW FREQUENCY OFF GRID SOLAR INVERTER MODEL PV20-1012 PK PV20-1512 PK PV20-2024 PK
PV2000 PK built-in high efficiency solar controller. AC input voltage range Output Waveform Pure sine wave
for 140VAC-280VAC with regulated output (AVR) features, PV, AC function, A Output Voltage Inverter mode: 230VAC(±5% RMS), AVR mode: 200VAC-240VAC 220VAC(±5% RMS)
tracking feature such as power frequency. The output frequency can be set Output Power Factor 0.7 0.6
using the keys, AC /PV charging voltage, charge current, AC or PV priority
Output Frequency 50Hz/60Hz ±0.2 Hz
mode, Battery under voltage shut-down point, and so many other functions.
Inverting Efficiency (peak) >85%
Mains Mode Efficiency > 95%
Transfer Time Typical 2~6ms 10ms(max)
AC INPUT
7
10. USB SOLAR CHARGER
11. PV Input Maximum PV Charge Current 50A±5A
11 12 13 14
12. Battery Input Battery Voltage 12VDC 24VDC
13. AC Input Maximum PV Array Power 150W*5 solar panels 150W*10 solar panels
14. AC Output Maximum PV Array Open Circuit Voltage 55Vdc
Maximum Efficiency > 95%
Solar system connection Standby Consumption <2W
MECHANICAL SPECIFICATIONS
Assembly Wall mount
Machine Dimension (W*H*D) 319*300.5*132.2mm
PV input
TV Fridge Lighting Fans
Package Dimension (W*H*D) 391*325*187mm
Solar Panel N.W (kg) /
G.W (kg) /
AC Input
OTHER
Working Environment 0°C~40°C 0~90% Relative humidity (non-condensing)
Utility
BAT input Noise Less than 60db
Display LED + LCD
Inverter CERTIFICATION & STANDARDS
Generator Battery
CE-EMC+LVD(EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011)
34
Products / 230V
LOW FREQUENCY SOLAR INVERTER PV29- PV29- PV29- PV29- PV29- PV29- PV29-
PV2900 HP Series
MODEL
1KW-HP 1.5KW-HP 2KW-HP 3KW-HP 4KW-HP 5KW-HP 6KW-HP
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
1~6KW | AC 230V | MPPT80A | WIFI | BMS | Dual output Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
PV2900 HP series is very economical pure sine wave solar inverter, Inbuilt with Capable Of Starting Electric Motor 1P 1P 1.5P 2P 3P
80A MPPT charger; Solar/AC priority is configurable, when setting solar priority, Waveform Pure sine wave / same as input (bypass mode)
solar will charge batteries as first priority, and AC can also charge batteries Nominal Output Voltage RMS 220V / 230V / 240VAC (±10% RMS)
when solar charger current is too lower, in this way system charge is optimazed
Output Frequency 50Hz / 60Hz ±0.3Hz
best. it enables inverter to operate with all kinds of home appliances.
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)
■ 3 Steps charging 100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ Overload and short-circuit protection Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Set charging voltage/charging current Load > 125% (alarm 10s then stop output and fault code 07)
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V AC INPUT
■ Power-save mode
Voltage 230VAC
■ Set utility priority /battery priority
■ Set utility input wide/narrow voltage range Selectable Voltage Range 155~265VAC(For personal computers)
■ Inverter voltage can be set to 220V/230V/240V Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Inverter frequency can be set to 50Hz/60Hz
BATTERY
■ Set utility charging on/off switch
■ Inbuilt 80A MPPT Solar Charge Controller Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Acid or Lithium Select Low Battery Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ WIFI remote monitoring (optional)
Low Battery Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ With BMS lithium battery communication function (CAN port)
■ Dual output for smart load management High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Back panel description Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
1. Power on/off switch Output Voltage Depends on battery type
2. BAT - Overcharge Protection S.D. 15.5VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
1~3KW 4~6KW 3. BAT + Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
4. AC Input PAYPASS & PROTECTION
5. Main load Input Voltage Waveform Sine wave (grid or generator)
1 2 3 4 5 6 7 1 2 3 4 5 6 7 6. Second load Nominal Input Frequency 50Hz or 60Hz
7. PV input
Overload Protection (SMPS Load) Circuit breaker
8. Fan
Output Short Circuit Protection Circuit breaker
9. Remote port
BACK SIDE AC Input Breaker 1-3K/30A 4-6K/50A
10. BMS Can Port
SOLAR CHARGER
11. AGS port
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
12. USB port
Maximum PV Charge Current 80A±4A
13. WIFI port (optional)
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
8 9 10 11 13 12 14 15 8 9 13 12 11 10 16 14. AC input protect
MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
15. AC output 10A(max)
Maximum PV Array Open Circuit Voltage 245VDC
16. AC Input breaker
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall Mount
Dimensions (W*H*D) 274*484*174mm 274*568.5*174mm
PV input Package Dimensions (W*H*D) 583.5*376*255mm 668.5*376*255mm
BAT input
Second Load Audible Noise 60dB MAX
Display LED+LCD
TV Air conditioner Washing machine
Standard Warranty 1 year
Generator Battery Inverter
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
36
Products / 230V
LOW FREQUENCY SOLAR INVERTER PV30- PV30- PV30- PV30- PV30- PV30- PV30-
100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ 3 Steps charging Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Overload and short-circuit protection Load > 125% (alarm 10s then stop output and fault code 07)
■ Set charging voltage/charging current
AC INPUT
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
Voltage 230VAC
■ Power-save mode
■ Set utility priority /battery priority Selectable Voltage Range 155~265VAC(For personal computers)
■ Set utility input wide/narrow voltage range Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Inverter voltage can be set to 220V/230V/240V BATTERY
■ Inverter frequency can be set to 50Hz/60Hz Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Set utility charging on/off switch Low Battery Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Inbuilt 80A MPPT Solar Charge Controller Low Battery Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Acid or Lithium Select
High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ WIFI remote monitoring (optional)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ With BMS lithium battery communication function (CAN port)
Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
Back panel description CHARGER
Output Voltage Depends on battery type
1. BAT - Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
1~3KW 4~6KW 2. BAT + Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
3. GND PAYPASS & PROTECTION
1 3 4 5 6 3 7 8 1 3 4 5 6 3 8 4. AC Input Input Voltage Waveform Sine wave (grid or generator)
5. AC Output Nominal Input Frequency 50Hz or 60Hz
6. PV Input Overload Protection (SMPS Load) Circuit breaker
7. AC Input protect Output Short Circuit Protection Circuit breaker
8. Wifi (optional) AC Input Breaker 1-3K/30A 4-6K/50A
9. AC Output 10A(MAX) SOLAR CHARGER
10. USB
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
11. AGS
Maximum PV Charge Current 80A±4A
12. BAT CAN
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
13. Remote port
15 14 13 2 12 11 10 9 15 14 13 2 12 11 10 7 MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
14. FAN
Maximum PV Array Open Circuit Voltage 245VDC
15. Power on/off switch
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall Mount
Dimensions (W*H*D) 493*303*200mm 531*305*202mm
38
Products / 230V
PV input
Mounting Wall Mount
TV Fridge Lighting Fans Dimensions (W*H*D) 493*303*200mm
Solar Panel Package Dimensions (W*H*D) 615*400*319mm
N.W (kg) /
AC Input
G.W (kg) /
OTHER
Utility BAT input
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Audible Noise 60dB MAX
Display LED+LCD
Generator Inverter
Battery
Standard Warranty 1 year
40
Products / 230V
LOW FREQUENCY SOLAR INVERTER MODEL PV36 PRO-8K PV36 PRO-10K PV36 PRO-12K
2. BAT+ 10. Wifi communication port Output short circuit protection Circuit breaker
3. AC input breaker 11. AC input Bypass breaker rating 80A 100A 100A
4. AC output breaker 12. AC outputr Max bypass current 36A 45A 54.5A
5. Remote control port 13. PV2 input SOLAR CHARGER
6. Fan 14. PV1 input Maximum PV charge current 100A(200A optional)
7. USB port 15. Ground DC voltage 48V
8. AGS port Maximim PV array power 5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC) 64~235VDC
5 6 7 8 9 10 11 12 13 14 15 Maximum PV array open circuit voltage 245VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall mount
Dimensions (W*H*D) 674*402*222mm
Package Dimensions (W*H*D) /
PV input
TV Fridge Lighting Fans N.W (kg) /
G.W (kg) /
Solar Panel
OTHER
Operation temperature range 0°C to 50°C
AC Input
Storage temperature -15°C to 60°C
BAT input
Audible noise 60dB MAX
Utility
Display LED+LCD
Loading (20GP/40GP/40HQ) 140pcs / 280pcs / 320pcs
Inverter
CERTIFICATION & STANDARDS
Generator
Battery
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)
42
Products / 230V
INVERTER OUTPUT
3~5KW | 145V | 80A MPPT
Rated Output Power 3KW 4KW 5KW
This is a multi-function inverter/charger, combining functions of inverter,
solar charger and battery charger to offer uninterruptible power support with Surge Power 6KW 8KW 10KW
portable size. Its comprehensive LCD display offers user-configurable and easy-
accessible button operation such as battery charging current, AC/solar charger Waveform Pure Sine Wave
priority, and acceptable input voltage based on different applications.
Power factor 1
OTHER
Safety Certification CE
TV Fridge Lighting Fans
PV input
Generator EN IEC62368-1
44
Products / 230V
INVERTER OUTPUT
5.2KW | 450V | 100A MPPT Rated Power 5200VA / 5200W
AC INPUT
■ Pure sine wave inverter
■ Configurable input voltage range for home appliances and personal Voltage 230VAC±5%
computers via LCD setting
■ Configurable battery charging current based on applications via LCD setting Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
■ Configurable AC/Solar Charger priority via LCD setting Frequency Range 50Hz / 60Hz(Auto sensing)
■ Compatible to mains voltage or generator power
BATTERY
■ Auto restart while AC is recovering
■ Overload/ Over temperature/ short circuit protection Normal voltage 48VDC
■ Smart battery charger design for optimized battery performance
Floating Charge Voltage 54.8VDC
■ Cold start function
■ Parallel operation with up to 3 units Overcharge Protection 60VDC
■ WIFI remote monitoring (optional)
SOLAR CHARGER & AC CHARGER
1. PV Input 7. Ground 13. RS485 communication port Maximum Charge Current 100A
2. AC input 8. Input breaker 14. WiFi port
3. AC output 9. Fault indicator 15. USB port MECHANICAL SPECIFICATIONS
4. LCD display 10. Charging indicator 16. Dry contact
Machine Dimension (W*H*D) 400*468*86.3mm
5. Parallel switch 11. Status indicator 17. Battery input
6. Parallel communication port (only for parallel mode) 12. Function buttons 18. Power on/off switch Package Dimension (W*H*D) /
G.W (kg /
OTHER
TV Fridge Lighting Fans
Solar Panel
Humidity 5% to 95% Relative humidity (Non-condensing)
Utility
Storage Temperature -25℃ ~60℃
Inverter
CERTIFICATION & STANDARDS
Battery
Generator CE/IEC
46
Products / 230V
INVERTER OUTPUT
■ Advanced technology optimizes battery life Low Battery Alarm 10.5VDC±0.2V 21.0VDC±0.4V
CHARGER
6
Charging Current 20A 20A±2A
5 7 Overcharge Protection S.D. 15.5VDC±0.4A 31VDC±0.8A
8
BYPASS & PROTECTION
9 10 11 12
Nominal Input Frequency 50Hz or 60Hz
4. LCD Display 8. ON / OFF 14. DC Input Connector (Battery Terminal) Max Bypass Current 10A
MECHANICAL SPECIFICATIONS
Solar system connection Machine Dimension (W*H*D) 246*253*87mm
48
Products / 230V
EP1500 Series Nominal Battery System Voltage 12VDC 12VDC 12VDC 24VDC
INVERTER OUTPUT
Rated Power 600VA / 600W 1000VA / 600W 1500VA / 1000W 2000VA / 1500W
0.6~2KVA | 12V/24V | 230V
Waveform Pure Sine Wave
EP1500 series is a pure sine wave inverter applied to TV, stereos, laptops, and Nominal Output Voltage RMS 230V
desktop computers and other home appliances. It will automatically switch to Output Voltage Regulation +10/-18%
inverter and provide power when AC is interrupted unexpectedly.It's perfect
for the user who need a simple and economical inverter,with user-friendly Output Frequency 50Hz / 60Hz ±1Hz
installation and setting. Inverter Efficiency (Peak) >90%
AC INPUT
■ Low shutdown loss for energy storage system application Voltage Range 184~278VAC ±3% 176~278VAC ± 3%
■ Support two kinds of batteries: Lithium Battery Pack and Lead-acid Battery Frequency Range 45~65Hz ± 2Hz
■ Support fast max charging current setting
BATTERY
■ Different charging mode for different kinds of batteries
■ Auto restart while AC recovery Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack - 12V(4 Series) 24V(8 Series)
■ Overload & short-circuit protection, Battery reverse polarity protection, Nominal Input Voltage 12VDC 12VDC 12VDC 24VDC
Deep discharge protection
■ Advanced technology optimizes battery life Low Battery Cutoff 10.5VDC(PB) 11.5VDC(LI) 10.5VDC(PB) 11.5VDC(LI) 10.5VDC(PB) 11.5VDC(LI) 21.0VDC(PB) 23.0VDC(LI)
■ Automatic line-to-battery switch over Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 11.0VDC(PB) 12.0VDC(LI) 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)
■ Automatic activate lithium battery pack which is be over discharged Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 12.5VDC(PB) 12.8VDC(LI) 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)
no output when AC input is OK
High Voltage Alarm 14.5VDC(PB) 14.5VDC(LI) 14.5VDC(PB) 14.5VDC(LI) 14.5VDC(PB) 14.5VDC(LI) 29.0VDC(PB) 29.0VDC(LI)
High Battery Voltage Recover 15.0VDC(PB) 14.8VDC(LI) 15.0VDC(PB) 14.8VDC(LI) 15.0VDC(PB) 15.0VDC(LI) 30.0VDC(PB) 29.6VDC(LI)
Back panel description
CHARGER
1 2 Boost Voltage 14.4VDC(PB) 14.4VDC(LI) 14.4VDC(PB) 14.4VDC(LI) 14.4VDC(PB) 14.4VDC(LI) 28.8VDC(PB) 28.8VDC(LI)
Float Voltage 13.8VDC(PB) 14.4VDC(LI) 13.8VDC(PB) 14.4VDC(LI) 13.8VDC(PB) 14.4VDC(LI) 27.6VDC(PB) 28.8VDC(LI)
1. ON / OFF
2. LCD Screen Charging Current 7A±2A @ 12V 10A±2A @ 12V 10A±2A @ 12V 7A±2A @ 24V
3. DC Input Connector (Battery Terminal) Charging Current 15A±2A @ 12V 20A±2A @ 12V 20A±2A @ 12V 15A±2A @ 24V
4. Charging max current setting switch
Overcharge Protection S.D. 15.5VDC 15.5VDC 15.5VDC 31VDC
5. Battery kind setting switch
BYPASS & PROTECTION
3 4 5 6 7 6. Output Receptacle(s)
7. AC Input with fuse box Nominal Input Frequency 50Hz / 60Hz (Auto sensing)
MECHANICAL SPECIFICATIONS
Material selection Solar system connection Dimensions (W*H*D) (mm) 320*231*96mm 255*80*224mm
OTHER
50
Products / 230V
INVERTER OUTPUT
1~5KW | 12V/24V/48V | 230V
Rated Power 1000W 2000W 3000W 4000W 5000W
This is a multi-function inverter/charger, combining functions of inverter, Surge Power 2000W 4000W 6000W 8000W 10000W
battery charger to offer uninterruptible power support with portable size.
Its comprehensive LCD display offers user-configurable and easy-accessible Waveform Pure sine wave
button operation such as battery charging current,
AC charger priority, and acceptable input voltage based on different Output Voltage Regulation 230Vac±5%
applications.
Output Frequency 60Hz or 50Hz
■ Overload/ Over temperature/ short circuit protection Nominal voltage 12VDC 24VDC 48VDC
■ Smart battery charger design for optimized battery performance
Floating Charge Voltage 13.7VDC 27.4VDC 54.8VDC
■ Cold start function
■ With BMS lithium battery communication function (CAN port) Overcharge Protection 15VDC 30VDC 60VDC
CHARGER
Back panel description Charging Current @ Nominal Input Voltage 10/20A 20/30A 20/30A 1~60A
PROTECTION
N.W (kg) /
Solar system connection
G.W (kg) /
OTHER
PV input
Operation Temperature Range -10℃ to 50℃
TV Laptop Air-conditioning Washing machine
Solar Panel
Storage temperature -15°C~ 60°C
MPPT solar charge
controller
Audible Noise 60dB MAX
Display LED+LCD
AC Input
BAT input
CERTIFICATION & STANDARDS
Generator
CE-EMC+LVD (EN6100-6-4, EN6100-6-2+EN IEC62109-1
52
Products / 230V
This is a multi-function inverter/charger, combining functions of inverter, Nominal Input Voltage 230Vac±5%
battery charger to offer uninterruptible power support with portable size.
Its comprehensive LCD display offers user-configurable and easy-accessible Selectable Voltage range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
button operation such as battery charging current,
Frequency Range 50Hz/60Hz (Auto sensing)
AC charger priority, and acceptable input voltage based on different
applications. Inverter Efficiency(Peak) 90%
INVERTER OUTPUT
1. Circuit breaker 5. USB port 9. Parallel communication port (only for parallel model) GENERAL
2. AC input 6. Dry contact 10. Parallel switch
Mounting Wall mount
3. AC output 7. Power on/off switch 11. WiFi port (optional)
4. RS485 communication port 8. Battery input Display LED+LCD
AC Input
N.W /
54
Products / 230V
56
Products / 230V
58
Products / 230V
■ Max 140A automatic 3-stage battery charger Frequency Range 50Hz / 60Hz
BATTERY
■ Charger current is Adjustable (0-100%)
Minimum start voltage 40.0V±0.6 / 42.0V±0.6
■ Automatically send signal to start generator Low battery alarm 42-50VDC
Low battery Cutoff 40.0V±0.6 / 42.0V±0.6
■ Supporting USB communication and BTS & AGS port
High voltage alarm 60VDC
■ Battery/AC priority High battery voltage recover 57VDC
Idle consumption-search mode <60W when power saver on
CHARGER
Back panel description
Output voltage Depends on battery type
Charger AC input breaker rating 80A
1 2 6 3 4 5
Max charge power rate 1/3 Rating power
Overcharge protection S.D. 62.8VDC
Maximum Charge Current 100A 120A 140A
1. Power saver on/off switch 10. AC input/output breaker
BTS
2. Inverter indicator 11. Ground
3. Grid indicator 12. AC output Temperature rate @25°C 4mv charging voltage descent, per 1℃ rise
7 8 9 10
4. Fault indicator 13. AC input BYPASS & PROTECTION
5. Function 14. WIFI Communication port Input voltage waveform Sine wave (grid or generator)
6. LCD display 15. USB Communication port Nominal voltage 220V / 230V / 240VAC
7. Remote panel 16. AGS Communication port Max input AC voltage 300VAC for 230VAC HV mode
8. BAT- 17. BTS Communication port Nominal input frequency 50Hz or 60Hz
9. BAT+ 18. FAN Overload protection (SMPS load) Circuit breaker
Output short circuit protection Circuit breaker
18 17 16 15 14 13 12 11 Bypass breaker rating 63A
Max bypass current 63Amp
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall mount
Machine Dimension (W*H*D) 670*410*215mm
Package Dimension (W*H*D) / / /
PV input
N.W /
TV Laptop Air-conditioning Washing machine
G.W / / /
Solar Panel MPPT solar charge OTHER
controller
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
AC Input Audible Noise 60bB MAX
Inverter Utility Display LED+LCD
BAT input Loading(20GP/40GP/40HQ) 200pcs / 400pcs / 500pcs
CERTIFICATION & STANDARDS
Generator
//////////
60
Products / 230V
LOW FREQUENCY POWER INVERTER EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30-
EP3000 PLUS series is a very economical pure sine wave inverter, with AC Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
charger from 20A to 60A; Solar/AC priority is configurable, when setting Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP 3HP
solar priority, solar will charge batteries as first priority, and AC can also Waveform Pure sine wave / same as input (bypass mode)
charge batteries when solar charger current is too lower . With pure copper
transformer, it enables inverter to operate with all kinds of home appliances. Nominal Output Voltage RMS 220V / 230V / 240VAC ±10% (RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
8 8 Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
9 9
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
10 10
11 11 BYPASS & PROTECTION
12 12
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
1. BAT - 6. AC input protect 11. USB port
2. BAT + 7. AC Output 10A(MAX) 12. WiFi port Output Short Circuit Protection Circuit breaker
3. GND 8. Remote port 13. Power on/off switch AC Input Breaker 1-3K/30A 4-6K/50A
4. AC input 9. BAT CAN 14. FAN MECHANICAL SPECIFICATIONS
5. AC output 10. AGS Mounting Wall Mount
Machine Dimension (W*H*D) 493*303*200mm 531*305*202mm
62
Products / 230V
AC INPUT
3~5KW | 230V | WIFI | BAT-CAN
Nominal Input Voltage 230Vac±5%
This is a multi-function inve inverter/charger ,combining Functions of inverter,
battery charger to offfer uninte uninterruptible power with portable size. Its Selectable Voltage range AC 185V~270V
comprehensive LCD display offers user-configurable and easy-accessible
Frequency Range 50Hz/60Hz (Auto sensing)
button operation such as battery charging current, AC charger, and acceptable
input voltage based on different applications.
Inverter Efficiency(Peak) 97%
INVERTER OUTPUT
BATTERY
Back panel description
Battery voltage 48VDC ( ±0.5)
Generator N.W /
Inverter
G.W /
BAT input
CE
64
Products / 230V
AC INPUT
5.2KW | 230V | WIFI | BAT-CAN
Nominal Input Voltage 230Vac±5%
This is a multi-function inve inverter/charger ,combining Functions of inverter,
battery charger to offfer uninte uninterruptible power with portable size. Its Selectable Voltage range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
comprehensive LCD display offers user-configurable and easy-accessible
Frequency Range 50Hz/60Hz (Auto sensing)
button operation such as battery charging current, AC charger, and acceptable
input voltage based on different applications.
Inverter Efficiency(Peak) 90%
INVERTER OUTPUT
■ Configurable AC Charger via LCD setting Transfer Time 10ms (UPS / VDE4105) / 20ms (APL) <50ms(For parallel operation)
CE
66
Products / 230V
3.6~6KW | Single Phase | 230VAC Maximum recommended DC power 4000W 5000W 5500W 6000W 7000W
Nominal DC operating voltage 360V
Maximum DC voltage 500V
This is a flexible and intelligent energy storage solar inverter with a wide range
MPPT voltage range 120V~500V
of MPPT Voltage.
Combining functions of off grid and on grid. This hybrid solar inverter can Maximum input current 15A / 15A
power all kinds of appliances in home or office, and can also be used in power No.of MPP tracker 2
stations. Strings per MPP tracker 1
INVERTER OUTPUT(AC)
Nominal AC output power 3600W 4000W 4600W 5000W 6000W
Nominal output voltage; range 220/230/240V;180-280V
AC grid frequency; range 50/60Hz; 45~55/55-65Hz
Nominal output current 15.6A 17.5A 20A 21.7A 26A
■ Multiple operation modes: Grid-tie,off grid with storage backup Maximum output current 16A 18.1A 20.8A 22.7A 27.2A
Inrush current (spike/duration) 57.5A/5.2us
■ IP65 water-proof and dust-proof
Total harmonic distortion i(THDi) <3%
■ MPPT voltage range 120-500V Power factor at rated power 1
■ Support LCD display&Smart LCD setting Displacement power factor 0.8leading ~ 0.8lagging
Grid type Single phase
■ Available Export control CT sensor function
BATTERY MODE OUTPUT(AC)
■ Multiple communications:USB,RS485,GPRS and wifi etc Output Rated Power 3600W 4000W 4600W 5000W 6000W
■ Full protection function:Over-voltage,over-frequency, over-current, Nominal output voltage; accuracy range 230±1%
over-temperature,and AC short-circuit automatic protection Output ferequency; accuracy range 50/60Hz (optional)±0.2%
■ Intelligent BMS battery management function Output rated current 15.6A 17.5A 20A 21.7A 26A
Output waveform Pure sine wave
■ Fanless low-noise design
Peak power 5400W,10s 6000W,10s 6900W,10s 7500W,10s 9000W,10s
■ Wifi monitoring Total harmonic distortion v (linear load) <3%
BATTERY & CHARGER
Back panel description Battery type Lead-acid battery / Lithium battery
Battery voltage 48V
Battery voltage range 40~60V
1 2 3 4 5 6 7 Charging curve 3-stage adaptive with maintenance
1. PV input terminals Protection Over-current protection / Over-temperature protection
2. Battery input terminals and cover Maximum charging power 3600W 4000W 4600W 5000W 6000W
3. Breather valve Maximum charging currernt 75A 85A 95A 100A 125A
4. PV input switch EFFICIENCY
5. BTS terminals, BMS terminals, load monitor terminals, dry contact terminals, Maximum efficiency 97.1%
CAN communication terminals, USB terminal and cover Euro-efficiency 96.5%
6. Wi-Fi commodule MPPT efficiency 99.8%
7. AC output terminals and cover PROTECTION DEVICES
DC switch rating for each MPPT; Grid monitoring; Output over current protection; Output overvoltage protection-varistor; Ground fault monitoring;
Integrated all-pole sensitive leakage current
GENERAL
Machine Dimension (W*H*D) 480*420*215mm
Solar system connection Package Dimension (W*H*D) /
G.W 27kg
N.W /
DC connection H4 / MC4
AC connection Terminal Block
Display LED+LCD
Application Communication interfaces Wi-Fi / USB / GPRS / RS485
Ingress protection rating IP65
Solar Humidity 0~95% RH(No codensing)
Operating temperature range -20℃ +60℃ With derating above 45℃
Cooling concept Natural
Altitude <3000m
CERTIFICATION & STANDARDS
Grid CE-EMC+LVD (EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011); CE-LVD(EN62477-1:2022)
IEC60529; EN50549-1:2019
Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021)
C10/C11
UNE217001-2020; UNE217002-2020, NTS-631:2021 (Type A)
Battery (optional) Generator G98+G99
68
Products / 230V
70
Products / 230V
The PH1600 PRO Series is designed for retrofitting PV systems, including power Nominal output current 17.5A 21.7A 26A
classes ranging from 4kw to 6kw. It can be installed with existing PV inverters, Maximum output current 18.1A 22.7A 27.2A
forming an AC coupling system. Inrush current (spike/duration) 57.5A/5.2us
Capable of being grid-interactive, it allows users to store surplus power and
sell it back to the grid when demand peaks and the price of electricity is at its Total harmonic distortion i(THDi) @Nominal Output <3%
highest. It runs reliably under even the most extreme conditions with metal Power factor at rated power ≈1
aluminium housing with IP66 protection. Displacement power factor Adjustable from 0. 8 leading to 0. 8 lagging
Grid type Single phase
BATTERY MODE OUTPUT(AC)
Output Rated Power 4000W 5000W 6000W
Nominal output voltage; accuracy range 230±1%
■ LCD+LED – user friendly interface
Output ferequency; accuracy range 50/60Hz (optional)±0.2%
■ IP66 design for outdoor
Output rated current 17.5A 23A 26A
■ Compatible with other brands of inverter
Output waveform Pure sine wave
■ Various work mode for different application scenarios Peak power 6000W/10S 7500W/10S 9000W/10S
■ Natural cooling without external fan Total harmonic distortion v (linear load) <3%
■ BMS Function BATTERY & CHARGER
■ Wifi monitoring Battery type Lead-acid battery / Lithium battery
72
Products / 230V
PH5900 Series
3000M 3600M 4200M 4600M 5000M 6000M
RATED POWER 3000W 3600W 4200W 4600W 5000W 6000W
PV INPUT(DC)
Maximum recommended DC power 3900W 4700W 5460W 5980W 6500W 7800W
3~6KW | Single Phase | 230VAC Nominal DC operating voltage 360V
Maximum DC voltage 550V
PH5900 series PV inverters take full account of the needs of end customers,
Start voltage 50V
with excellent performance at the same time, use LED as inverter status display,
effectively improve product life. Using DSP digital control,could afford wide MPPT voltage range 40~550V
grid voltage range, have a full range of protection features; to maximize the Maximum input current 16A/16A
benefits at the same time, greatly enhance the reliability of the product. No.of MPP tracker/ strings per MPP tracker 2/1
DC connection H4/MC4
GRID OUTPUT(AC)
Nominal AC output power 3000W 3600W 4200W 4600W 5000W 6000W
Max. AC output power 3000VA 3600VA 4200VA 4600VA 5000VA 6000VA
AC grid frequency 50/60Hz ±5Hz
■ High Frequency On Grid Solar Inverter Maximum output current 13.6A 16A 19A 20.9A 22.7A 27.2A
■ Rate power: 3-6KW AC nominal voltage 220V/230V/240V
AC voltage range 180-280V
■ MPPT efficiency up to 99.50%
Total harmonic distortion (THDi) <3%
■ Multiple communications: WIFI etc
Rate power factor 1
■ Monitoring inverters freely via mobile phonese APP Power factor adjustable range 0.8 leading ~ 0.8 lagging
■ Fanless low-noise design AC grid connection type L+N+PE
74
Products / 230V
ON GRID SOLAR INVERTER PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59-
PH5900 TM Series
MODEL 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 15000
TM TM TM TM TM TM TM TM TM TM TM
Rated AC output power 4000W 5000W 6000W 7000W 8000W 9000W 10000W 11000W 12000W 13000W 15000W
OUTPUT (AC)
4~15KW | Three-phase | 380VAC
Max.AC apparent power 4400VA 5500VA 6600VA 7700VA 8800VA 9900VA 11000VA 12100VA 13200VA 14300VA 16500VA
PH5900TM series PV inverters take full account of the needs of end customers, Max.output current 6.4A 8A 9.6A 11.1A 12.7A 14.3A 15.9A 17.5A 19A 20.6A 23.8A
It is used to convert the DC generated by photovoltaic panels into AC and send
Nominal AC Voltage 230V / 400V
it to the grid in a three-phase manner.with excellent performance at the same
time, use LED as inverter status display, effectively improve product life. Using AC Voltage range 320-478V
DSP digital control,could afford wide grid voltage range, have a full range of
AC grid frequency range 50/60Hz ±5Hz
protection features; to maximize the benefits at the same time, greatly enhance
the reliability of the product. Power factor at Rated power 1
INPUT DATA
■ Wide MPPT voltage range from 200V-1000V
Max.recommended PV power 4800W 6000W 7200W 8400W 9600W 10800W 12000W 13200W 14400W 15600W 18000W
■ IP66 protection degree
Max.DC voltage 1000V
■ Integrated DC switch
Start voltage 160V
■ DSP controller
Nominal voltage 600V
■ The maximum efficiency is 98.4%
MPPT voltage range 200V-1000V
■ Multi MPPT controller
12.5A/ 12.5A/ 12.5A/ 12.5A/ 12.5A/ 12.5A/ 12.5A/ 12.5A/ 21A/ 21A/ 21A/
■ WIFI monitoring standard Max.input current
12.5A 12.5A 12.5A 12.5A 12.5A 12.5A 12.5A 12.5A 11A 11A 11A
■ Easy installation Number of independent MPP trackers
2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/2+1 2/2+1 2/2+1
/ strings per MPP tracker
DC connection H4 / MC4
EFFICIENCY
Back panel description Max.efficiency 98.4%
Euro weighted efficiency 97.6% 97.6% 97.6% 98% 98% 98% 98% 98% 98% 98% 98%
1 2 3 4 5 6 7 8 9
1. PV1 input Island protection, DC reverse polarity protection , Output over current protection,
Protection devices Output overvoltage protection-varistor, Integrated DC switch, Ground fault monitoring,
2. PV2 input
Integrated all-pole sensitive leakage current monitoring unit
3. DC switch
GENERAL DATA FEATURES
4. Ground
5. WIFI connector Dimension(W/H/D)(mm) 539.7*426.2*216.9mm
6. USB port Weight (kg) 21 23.2 24.8
7. RS-485 connector
Operation temperature range -25℃ - +60℃ with derating above 45℃
8. Meter port
9. AC output Noise emission(typical) ≤35dB(A)
Altitude 3000m
FEATURES
Display LED
76
Products / 230V
ON GRID SOLAR INVERTER PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59- PH59-
PH5900 TM Series
MODEL 17000 18000 19000 20000 21000 22000 23000 24000 25000
TM TM TM TM TM TM TM TM TM
Rated AC output power 17000W 18000W 19000W 20000W 21000W 22000W 23000W 24000W 25000W
Max.AC apparent power 18700VA 19800VA 20900VA 22000VA 23100VA 24200VA 25300VA 26400VA 27500VA
PH5900TM series PV inverters take full account of the needs of end customers, Max.output current 27.1A 28.6 30.2 31.8A 33.5A 35A 36.6A 38A 39A
It is used to convert the DC generated by photovoltaic panels into AC and send
it to the grid in a three-phase manner.with excellent performance at the same Nominal AC Voltage 230V/400V
time, use LED as inverter status display, effectively improve product life. Using AC Voltage range 320-478V
DSP digital control,could afford wide grid voltage range, have a full range of
protection features; to maximize the benefits at the same time, greatly enhance AC grid frequency range 50/60±5Hz
the reliability of the product. Power factor at Rated power 1
INPUT DATA
■ Wide MPPT voltage range from 200V-1000V
Max.recommended PV power 25500W 27000W 28500W 30000W 31500W 33000W 34500W 36000W 37500W
■ IP66 protection degree
■ WIFI monitoring standard Max.input current 26A/26A 26A/26A 26A/26A 26A/26A 26A/39A 26A/39A 26A/39A 26A/39A 26A/39A
DC connection H4 / MC4
EFFICIENCY
Euro weighted efficiency 98.3% 98.3% 98.3% 98.3% 98.3% 98.3% 98.3% 98.3% 98.3%
Altitude 3000m
FEATURES
AC connection Connector
Solar On-Grid Home Load
Display LED
78
Products / 230V
INVERTER OUTPUT
8~10KW | Three-phase | 380VAC
Rated Power 8000W 10000W
This is a multi-function inverter/charger, combining functions of inverter,
Surge Power 16000W 20000W
solar charger and battery charger to offer uninterruptible power support with
portable size. Its comprehensive LCD display offers user-configurable and easy-
Waveform Pure Sine Wave
accessible button operation such as battery charging current, AC/solar charger
priority, and acceptable input voltage based on different applications.
AC Voltage Regulation (Batt.Mode) 230VAC±5%
12. USB
Charging Algorithm 3-step (Flooded Battery / AGM / GEL/ LEAD Battery), 4-step(LI)
13. Dry contact
14. WiFi port GENERAL DATA FEATURES
N.W (kg) /
AC Input
80
Products / 230V
ON/OFF GRID HYBRID SOLAR INVERTER MODEL PH18-3024 PRO PH18-5248 PRO
INVERTER OUTPUT
PH1800 PRO is a multi-function inverter/charger, combining functions of Surge Power 6000W 10400W
inverter, MPPT solar charger and battery charger to offer uninterruptible power
support in portable size. PH1800 PRO Series can run without battery. The Waveform Pure sine wave
Maximum PV array open circuit voltage can reach 450V and MPPT voltage
is 150~430V, which can help customers make full use of solar energy. AC Voltage Regulation (Batt.Mode) 230VAC±5%(Setting)
■ Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
Voltage 230VAC±5%
■ Built-in MPPT solar charge controller
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105)
■ MAX PV Array Open Circuit Voltage: 450V
■ Combining solar system, AC utility, and battery power source to supply Frequency Range 50Hz / 60Hz(Auto sensing)
continuous power
BATTERY
■ Overload, short circuit and Deep discharge protection
■ Support USB, RS485 monitoring function Floating Charge Voltage 27.4VDC 54.8VDC
■ Parallel operation with up to 3 units
Overcharge Protection 30VDC 60VDC
■ WIFI remote monitoring (optional)
SOLAR CHARGER & AC CHARGER
1 2 3 7 8 9 10 11 12 1. AC Input Charging Algorithm 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li)
2. AC Output
Maximum PV Array Power 4000W 5000W 6000W
3. PV Input
4. Power On/Off Switch PV Array MPPT Voltage Range 150~430 VDC
6 5 4 5. Battery Input
6. Circuit breaker Maximum Solar Charge Current 80A 100A 80A 100A
7. Dry Contact
5KW Maximum AC Charge Current 60A 80A 60A 80A
1 2 9 8 7 3 4 12 8. USB port
9. RS-485/CAN Communication port Maximum Charge Current 80A 100A 80A 100A
10. Parallel switch (only for parallel model)
MECHANICAL SPECIFICATIONS
11. Parallel communication port
(only for parallel model)
Machine Dimension (W*H*D) 322*486*134mm 309*505*147mm
12. USB WiFi port
6 10 11 5
Package Dimension (W*H*D) 575*229*425mm 603*260*400mm
OTHER
PV input
TV Fridge Lighting Fans
Humidity 5% to 95% Relative humidity (Non-condensing)
Solar Panel
Utility
CERTIFICATION & STANDARDS
BAT input
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
EN IEC62368-1:2020+A11:2020
EN IEC62368-1:2018
Inverter
Generator Battery Rohs-(2011/65/EUand2015/863/EU)
82
Products / 230V
INVERTER OUTPUT
■ Smart LCD setting(Working modes, Charge Current, Charge Voltage, etc.) AC input maximum current 26.0A per phase 34.8A per phase
■ Built-in MPPT 180A solar charge controller Nominal frequency 50Hz / 60Hz
■ MPPT Efficiency max 98%
Defaults 186Vac ~253Vac per phase;Narrow 174Vac ~272Vac per phase;
■ Combining solar system, AC utility, and battery power source to supply Acceptable input voltage range
Wide 95Vac ~272Vac per phase
continuous power
■ Multiple operations: basic Grid-tie, Off-Grid, Grid-Interactive BATTERY
■ Support CAN, RS485 monitoring function Type of Battery Lithium battery or lead-acid battery
OTHER
Solar Panel
Environmental Protection Rating IP20
84
Products / 230V
PURE SINE WAVE INVERTER PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15-
MODEL
PI1500 Series
0312 0324 0612 0624 1012 1024 1512 1524 2012 2024
BATTERY DC INPUT
Input Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC
300~2000W | 12V,24V | 230V Low Voltage Protect Delay 2 seconds
PI1500 series is a pure sine wave inverter, high frequency machine solution, the (PB) 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC
Low Voltage Warning
product is small size, the solution is reliable and stable, the main function is to (LI) 10.5VDC 21.0VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC
invert the DC 12VDC battery or 24VDC battery to AC 230VAC output, mainly
used for emergency use Electricity, car inverter, outdoor electricity and other (PB) 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC
Low Voltage Protect
occasions. (LI) 11.5VDC 23.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC
(PB) 12.5VDC 25.0VDC 12.5VDC 25.0VDC 12.5VDC 25.0VDC 12.5VDC 23.0VDC 12.5VDC 23.0VDC
Low Voltage Restoring
(LI) 12.5VDC 25.0VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC
(PB) 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC
Over Voltage Protect
■ Input Voltage 12V / 24V DC optional (LI) 14.7VDC 29.4VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC
■ Output Voltage 230V AC optional (PB) 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC
Over Voltage Restoring
■ Portable power for AC products, AC outlets for connecting multiple loads (LI) 15.0VDC 30.0VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC
■ High efficiency converts virtually all of the battery's power to AC Parameters: (PB) Lead-acid Battery / (Ll) 4 series (12V), 8 series (24V) LiFePO4 Lithium Battery Pack
■ Mounting brackets for convenient installation
INVERTER AC OUTPUT
■ Overload and over temperature shut down
Default Power 300W 600W 1000W 1500W 2000W
■ Low voltage and over voltage alarm/cut off
Peak Power 600W 1200W 2000W 3000W 4000W
■ Short circuit protection
Output AC Voltage 230V 230V 230V 230V 230V
Battery Input Protection Low Voltage Protection, Over Voltage Protection, Reverse Protection
MPPT Solar Chage LED Digital Display / Display Battery Voltage, Output Power, Output Voltage, Error Numbers
Controller
Inverter DC OUTPUT
12V/24V EFFICIENCY
Car cigarette lighter
(Load must lower 120W; Available for 300W only) Peak Conversion efficiency 91% 91% 90% 88% 90% 88% 90%
ENVIRONMENT
Laptop Lighting TV Fans
Protection Degree IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20
Altitude ≤3000m
DIMENSIONS
G.W (kg) 9.3kg (8pcs) 15kg (8pcs) 23kg (8pcs) 19kg (4pcs)
86
120V Series
Off Grid Solar Inverter/ On/Off Grid Hybrid Solar Inverter/ Grid-Tie Solar Inverter/ Off Grid Power Inverter
88
Products / 120V
■ Support fast max charging current setting Low Battery Alarm 11.0VDC(PB) 12.0VDC(LI) 22.0VDC(PB) 24.0VDC(LI)
■ Support two kinds of batteries: LiFePO4 Lithium Battery Packand Lead-acid Battery Low Battery Voltage Recover 12.5VDC(PB) 12.8VDC(LI) 25.0VDC(PB) 25.6VDC(LI)
■ Automatic activate lithium battery pack which is be over discharged no High Battery Voltage Recover 14.5VDC(PB) 14.3VDC(LI) 29.0VDC(PB) 28.6VDC(LI)
output when AC input is OK
High Battery Voltage Cutoff 15.0VDC(PB) 14.8VDC(LI) 30.0VDC(PB) 29.6VDC(LI)
SOLAR CHARGER & AC CHARGER
Back panel description Charger Voltage boost 14.4VDC(PB) 14.4VDC(LI) 28.8VDC(PB) 28.8VDC(LI)
Charger Voltage float 13.8VDC(PB) 14.4VDC(LI) 27.6VDC(PB) 28.8VDC(LI)
Maximum PV Charge Current 40A (max)
Maximum PV Array Power 600W 1200W
1. DC Input MPPT Operating Voltage Range 14 ~ 75VDC 28 ~ 75VDC
1 2 3 4 5 6 7 8 2. Solar panel terminal
Maximum PV Array Open Voltage 100VDC
3. ON/OFF
4. USB-A WIFI communication Maximum Efficiency > 95%
Inverter
CERTIFICATION & STANDARDS
///////////////////
90
Products / 120V
HIGH FREQUENCY OFF GRID SOLAR INVERTER PV18-1012 PV18-1512 PV18-1524 PV18-2024 PV18-3024 PV18-3048
MODEL
PV1800 LV Series
LV LV LV LV LV LV
Nominal Battery System Voltage 12VDC 12VDC 24VDC 24VDC 24VDC 48VDC
INVERTER OUTPUT
1~3KW | 120V | Wifi
Rated Power 1000W 1500W 1500W 2000W 3000W 3000W
PV1800 LV Series is a multi-function inverter/charger, combining functions
of inverter, MPPT solar charger and battery charger to offer uninterruptible Surge Power 1000W 1500W 1500W 4000W 6000W 6000W
power support with portable size. Its comprehensive LCD display offers user-
configurable and easy-accessible button operation such as battery charging Waveform Pure sine wave
current, AC/solar charger priority, and acceptable input voltage based on
different applications. AC Voltage Regulation (Batt.Mode) 120VAC ±5%
■ 2 units can be wired in parallel to create a split-phase system Selectable Voltage Range 107~132VAC(UL)
with 120V and 240V capabilities (only for 3kw)
Frequency Range 50Hz / 60Hz(Auto sensing)
■ Support parallel operation up to 3 units (only for 3kw)
9. Dry contact
Maximum AC Charge Current 10A 10A 30A 40A 80A 60A
10. USB wifi
11. Parallel switch (only for parallel model) Maximum Charge Current 70A 70A 90A 100A 100A 140A
12. Parallel communication port (only for parallel model)
MECHANICAL SPECIFICATIONS
92
Products / 120V
INVERTER OUTPUT
6KW | 120V,240V | Wifi
Rated Power 6000W
This split phase solar inverter PV1800 TLV series, capacity 6KW, DC 48V, it’s
applicable to 110VAC/120VAC markets demands, which has AC output of single Surge Power 12000VA
phase 110VAC/120V, split phase 220V/240V; In LCD display, you can set output
voltage, frequency, charging voltage, charging current to design best use based Waveform Pure sine wave
on different loads applications; meanwhile, it has built-in two 80A MPPT solar
charge controllers, you can take use of sunshine freely and save electricity bills. AC Voltage Regulation (Batt.Mode) 120VAC/240VAC ±5% (L-L)
■ 2 units can be wired in parallel to create a split-phase system Selectable Voltage Range 214~264VAC(UL)
with 120V and 240V capabilities
MECHANICAL SPECIFICATIONS
PV1 input
N.W 20kg
Solar Panel
G.W 22kg
TV Fridge Lighting Fans
94
Products / 120V
LOW FREQUENCY SOLAR INVERTER PV29- PV29- PV29- PV29- PV29- PV29- PV29-
1~6KW | AC 120V | MPPT80A | WIFI | BMS | Dual output Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
PV2900 LHP series is very economical pure sine wave solar inverter, AC voltage Capable Of Starting Electric Motor 1P 1P 1.5P 2P 3P
110V/120V, AC charger inbuilt, from 20A to 60A; MPPT solar charger 80A Waveform Pure sine wave / same as input (bypass mode)
inbuilt; Solar/AC priority is configurable, when setting solar priority, solar will Nominal Output Voltage RMS 110V / 115V / 120VAC(±10% RMS)
charge batteries as first priority, and AC can also charge batteries when solar
Output Frequency 50Hz / 60Hz ±0.3Hz
charger current is not enough, it enables inverter to operate with all kinds of
home appliances, widely selling to Latin America. Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)
■ Pure sine wave output 100% < Load < 110% (alarm 5min then stop output and fault code 07)
■ 3 Steps charging Overload 110% < Load < 125% (alarm 60s then stop output and fault code 07)
■ Overload and short-circuit protection Load > 125% (alarm 10s then stop output and fault code 07)
■ Set charging voltage/charging current. AC INPUT
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
Voltage 110/120VAC
■ Power-save mode
■ Set utility priority/ Battery priority Selectable Voltage Range 75~135VAC (For personal computers)
■ Set utility input wide/narrow range Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
■ Inverter voltage can be set to 120V:110V/115V/120V
BATTERY
■ Inverter frequency can be set to 50/60Hz
■ Set utility charging on/off switch Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ 80A MPPT charger Low Battery Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Acid or Lithium Select
Low Battery Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ WiFi port (optional)
■ With BMS lithium battery communication function (CAN port) High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
■ Dual output for smart load management High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Back panel description Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
1. Power on/off switch Output Voltage Depends on battery type
2. BAT - Overcharge Protection S.D. 15.5VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
1~3KW 4~6KW 3. BAT + Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
4. AC Input PAYPASS & PROTECTION
5. Main load Input Voltage Waveform Sine wave (grid or generator)
1 2 3 4 5 6 7 1 2 3 4 5 6 7 6. Second load Nominal Input Frequency 50Hz or 60Hz
7. PV input
Overload Protection (SMPS Load) Circuit breaker
8. Fan
Output Short Circuit Protection Circuit breaker
9. Remote port
BACK SIDE AC Input Breaker 1-3K/40A 4-6K/63A
10. BMS Can Port
SOLAR CHARGER
11. AGS port
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
12. USB port
Maximum PV Charge Current 80A±4A
13. WIFI port (optional)
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
8 9 10 11 13 12 14 15 8 9 13 12 11 10 16 14. AC input protect
MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
15. AC output 10A(max)
Maximum PV Array Open Circuit Voltage 245VDC
16. AC Input breaker
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Solar system connection
Mounting Wall Mount
Dimensions (W*H*D) 274*484*174mm 274*568.5*174mm
PV input Package Dimensions (W*H*D) 583.5*376*255mm 668.5*376*255mm
BAT input
Second Load Audible Noise 60dB MAX
Display LED+LCD
TV Air conditioner Washing machine
Standard Warranty 1 year
Generator Battery Inverter
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)
96
Products / 120V
LOW FREQUENCY SOLAR INVERTER PV30- PV30- PV30- PV30- PV30- PV30- PV30-
PV input
Package Dimension (W*H*D) 615*400*319mm 688*400*319mm
TV Fridge Lighting Fans N.W / /
Solar Panel G.W / /
OTHER
AC Input
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Utility
Audible Noise 60dB MAX
BAT input Display LED+LCD
Standard Warranty 1 year
CERTIFICATION & STANDARDS
Inverter
Generator Battery /
98
Products / 120V
LOW FREQUENCY SPLIT PHASE SOLAR INVERTER PV33-3024 PV33-3048 PV33-4024 PV33-4048 PV33-5048 PV33-6048
INVERTER OUTPUT
Rated power 3KW 4KW 5KW 6KW
3~6KW | AC110V/220V | MPPT 80A | WiFi | BAT-CAN Power factor 1
Wave form Pure sine wave
This split phase solar inverter PV3300 TLV series, capacity range from 3KW-
Output voltage RMS 100V / 110V / 120VAC (200V / 220V / 240VAC) ±10%
6KW, DC24V/48V, it’s applicable to 110VAC/120VAC markets demands, which
has AC output of single phase 110VAC/120V, split phase 220V/240V; In LCD Output frequency 50Hz or 60Hz (±0.3Hz)
display, you can set output voltage, frequency, charging voltage, charging Inverter efficiency (peak) >85%
current to design best use based on different loads applications; meanwhile,
Line mode efficiency >95%
it has built-in MPPT solar charge controller 80A, you can take use of sunshine
freely and save electricity bills. 100%<Load<110% (alarm 5min then stop outputand fault code 07)
Overload 110%<Load<125% (alarm 60s then stop output and fault code 07)
Load > 125% (alarm 10s then stop output and fault code 07)
Surge rating 9000VA 12000VA 15000VA 18000VA
Capable of starting electric motor 1.5P 2P 3P
■ Friendly user interface; MFD (multi-function display) BATTERY
■ 3 Steps charging Battery voltage 24VDC/48VDC 48VDC
■ Overload and short-circuit protection
Minimum start voltage 10V/ 10.5V/ 11V/ 11.5V/ 12V±0.5V; 12VDC×2 for 24V; ×4 for 48VAC
■ Set charging voltage/charging current.
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V low voltage fault code 04
(10V/ 10.5V/ 11V/ 11.5V/ 12V) for 12V model
■ Set utility priority/ Battery priority Low battery cut off
(21V/21V /22V/ 23V/ 24V) for 24V model
■ Set utility input wide/narrow range (40V/ 42V/ 44V/ 46V/ 48V) for 48V model
■ Inverter voltage can be set to 100/110/120; frequency can be set to 50/60Hz
Add 0.5/battery: (low battery alarm one second one time)
■ Set utility charging on/off switch (10V/ 10.5V/ 11V/ 11.5V/ 12V) +0.5VDC for 12V model
Low battery alarm
■ Built-in 80A MPPT charger (21V/ 21V/ 22V/ 23V/ 24V) +1VDC for 24V model
■ Acid or Lithium Select (40V/ 42V/ 44V/ 46V/ 48V) +2VDC for 48V model
■ WiFi port (optional) Add +1V/battery: (high voltage one second one time / after 30s fault 03)
(12-14.5V) +1VDC for 12V model
■ With BMS lithium battery communication function (CAN port) High voltage alarm
(24-29V) +2VDC for 24V model
(48-58V) +4VDC for 48V model
Back panel description
Save mode Load ≤40W(110V) / 80W(220V)
AC INPUT MODE
Input waveform Pure sine wave
1 2 3 4 5 6 7 Nominal input voltage 200Vac / 220Vac / 240Vac
1. Battery -/+
2. PV -/+ Max input voltage 270Vac MAX
3. Switch on/off Input frequency 50Hz / 60Hz (auto sensing)
4. AC Output: HOT1-HOT2 200VAC/220VAC/240VAC
5. AC Output: HOT1-N 100VAC/110VAC/120VAC Efficiency (AC mode) >95% (load, full battery)
9
6. AC Output: HOT2-N 100VAC/110VAC/120VAC Transfer time AC to DC 15ms(typical)
8
7. AC Input: HOT1-HOT2 200VAC/220VAC/240VAC
13 8. Remote Port SOLAR CHARGER
10 9. BAT CAN Maximum PV Array Power 2500W 5000W 2500W 5000W 5000W 5000W
11 10. AGS
12 11. USB Maximum PV Charge Current 80A±4A
12. WiFi (optional) DC Voltage 24V / 48V 24V / 48V
13. AC Input breaker
MPPT Range @ Operating Voltage 30~230VDC @ 24V /60~230VDC @48V 60~230VDC @48V
Maximum Solar Input Voltage 245±2Vdc 245±2Vdc
Maximum Efficiency >98%
Standby Power Consumption <2W
Solar system connection
CHARGE MODE
12V / / / /
Generator
Lighting Lighting Lighting Lighting
Warranty 1year
100
Products / 120V
LOW FREQUENCY SOLAR INVERTER MODEL PV36-8048 TLV PV36-10048 TLV PV36-12048 TLV
■ Built-in MPPT solar charge controller 100A/200A Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
■ MPPT efficiency max 98%
BATTERY
■ Powerful charge rate up to 140Amp
Low battery voltage cutoff 40-48VDC for 48VDC mode
■ Inside BMS function
Low battery voltage recover 42-50VDC for 48VDC mode
■ DC start &Automatic Self-Diagnostic Function High battery voltage cutoff 60VDC for 48VDC mode
■ WIFI / USB monitoring function (wi-fi optional) High battery voltage recover 57VDC for 48VDC mode
■ Supporting AGS, BTS port Idle consumption-search mode <80W when power saver on
1 2 3 4 Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
1. BAT- 9. BTS port Input voltage waveform Sine wave (grid or generator)
2. BAT+ 10. Wifi communication port Nominal input frequency 50Hz or 60Hz
3. AC input breaker 11. AC input Overload protection (SMPS Load) Circuit breaker
4. AC output breaker 12. AC outputr
Output short circuit protection Circuit breaker
5. Remote control port 13. PV2 input
Bypass breaker rating 63A 63A 63A
6. Fan 14. PV1 input
Max bypass current 80A
7. USB port 15. Ground
SOLAR CHARGER
8. AGS port
Maximum PV charge current 100A/200A
5 6 7 8 9 10 11 12 13 14 15 DC voltage 48V
Maximim PV array power 5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC) 64~235VDC
Solar system connection Maximum PV array open circuit voltage 250VDC
Maximum effciency >98%
Standby power consumption <2W
PV1 input MECHANICAL SPECIFICATIONS
Mounting Wall mount
PV2 input TV Fridge Lighting Fans
Solar Panel
Dimensions (W*H*D) 674*402*222mm
Package Dimensions (W*H*D) 818*577.5*415mm
AC Input
OTHER
Operation temperature range 0°C to 50°C
Utility
Storage temperature -15°C to 60°C
BAT input Audible noise 60dB MAX
102
Products / 120V
■ Powerful charge rate up to 200A Low battery voltage cutoff 40-48VDC for 48VDC mode
Low battery voltage recover 42-50VDC for 48VDC mode
■ Inside BMS function
High battery voltage cutoff 60VDC for 48VDC mode
■ DC start &Automatic Self-Diagnostic Function High battery voltage recover 57VDC for 48VDC mode
■ WIFI monitoring function (optional) Idle consumption-search mode <50W
AC CHARGER
■ Compatible to generator
Output voltage Depends on battery type (Supports lead-acid, gel, and lithium batteries)
■ Parallel operation with up to 3 units
Charger AC input breaker rating 100A
Overcharge protection S.D. 62.8VDC for 48VDC mode
Maximum charge current 10-140A (setting) battery terminal
Back panel description
BTS
Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
1 2 3 4 5 6 7 Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Software + Circuit breaker
1. Battery -/+ 8. AC output switch
Output short circuit protection Software + Circuit breaker
2. Communication port 9. AC input switch
Bypass breaker rating 63A
3. PV input 1 10. Lighting protection
Max bypass current 80A
4. PV input 2 11. PV2 Switch
SOLAR CHARGER
5. GEN port 12. PV1 Switch
Maximum PV charge current 200A
6. Grid port 13. WiFi port
DC voltage 48V
7. AC ouput
Maximim PV array power 10000W
13 12 11 10 9 8 MPPT range @ operating voltage(VDC) 64~235VDC
Maximum PV array open circuit voltage 250VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Parallel operation Solar system connection
Mounting Wall mount
Packing Wooden box
Dimensions (W*H*D) 439*570*233mm
Package Dimensions (W*H*D) 690*214*520mm
N.W 42kg
G.W 47kg
Warranty 1years
PV2 PV1 Home Load
OTHER
Operation temperature range 0°C to 50°C
Battery
Storage temperature 15°C to 60°C
Grid
Audible noise 60dB MAX
Loads N
L Communication WiFi
Display LED+LCD
CERTIFICATION & STANDARDS
Utility Grid N
L
Battery Generator
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011); UL1741
104
Products / 120V
This is a multi-function inverter/charger, combining functions of inverter, Nominal Input Voltage 120Vac±5%
battery charger to offer uninterruptible power support with portable size.
Its comprehensive LCD display offers user-configurable and easy-accessible Selectable Voltage range 90~145VAC(UPS) / 74~145VAC(APL) / 108~132VAC(VDE)
button operation such as battery charging current,
Frequency Range 50Hz/60Hz (Auto sensing)
AC charger priority, and acceptable input voltage based on different
applications. Inverter Efficiency(Peak) 95%
INVERTER OUTPUT
1. Circuit breaker 5. USB port 9. Parallel communication port (only for parallel model) GENERAL
2. AC input 6. Dry contact 10. Parallel switch
Mounting Wall mount
3. AC output 7. Power on/off switch 11. WiFi port (optional)
4. RS485 communication port 8. Battery input Display LED+LCD
AC Input
N.W /
106
Products / 120V
EH2900 LV Series
LV LV LV LV LV LV LV LV LV
108
Products / 120V
LOW FREQUENCY POWER INVERTER/CHARGER EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30- EP30-
1. BAT - 6. AC input protect 11. USB Nominal Input Frequency 50Hz or 60Hz
2. BAT + 7. AC Output 10A(MAX) 12. WiFi Overload Protection (SMPS Load) Circuit breaker
3. GND 8. Remote port 13. Power on/off switch Output Short Circuit Protection Circuit breaker
4. AC input 9. BAT CAN 14. FAN AC Input Breaker 30A 40A 50A / 63A
5. AC output 10. AGS
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Solar system connection Machine Dimension (W*H*D) 493*303*200mm 531*305*202mm
Package Dimension (W*H*D) 615*400*319mm 686*400*319mm
G.W /
PV input
N.W /
TV Laptop Lighting Fans
OTHER
Solar Panel MPPT solar charge
controller Operation Temperature Range 0°C to 40°C
Storage Temperature -15°C to 60°C
Audible Noise 60dB MAX
AC Input
Display LED+LCD
Utility
Standard Warranty 1 year
BAT input Inverter
CERTIFICATION & STANDARDS
Generator /
110
Products / 120V
LOW FREQUENCY SPLIT PHASE POWER INVERTER EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33- EP33-
■ With BMS lithium battery communication function (CAN port) Low battery voltage cut off 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Back panel description
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
AC INPUT MODE
1 2 13 9 10 11 12 1. Battery -/+ Input waveform Pure sine wave
2. Switch on/off
3. Remote port Nominal input voltage 200Vac / 220Vac / 240Vac
4. BAT CAN
Max input voltage 270Vac MAX
5. AGS
3 6. USB Input frequency 50Hz / 60Hz (auto sensing)
7. WiFi port
8
8. AC Input protect: Input protect breaker Efficiency (AC mode) >95% (load, full battery)
9. AC Output: HOT1 - HOT2 200VAC/220 VAC/240VAC
10. AC Output: HOT1 - N 100VAC/110 VAC/120VAC Transfer time AC to DC 15ms(max)
7
11. AC Output: HOT2 - N 100VAC/110 VAC/120VAC
Transfer time DC to AC 15ms(max)
12. AC Input:HOT1 - HOT2 200VAC/220 VAC/240VAC
4 5 6 13. Fan CHARGE MODE
Boost voltage 14.1V(Default) Range of adjustment 12-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)
Float voltage 13.5V(Default) Range of adjustment 12-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)
Solar Panel MPPT solar charge 120VAC LOAD Machine Dimension (W*H*D) 443*359.2*188mm 361.8*543.5*188.5mm
controller HOT1&N or Hot2&N
Package Dimension (W*H*D) 598*457*308mm 698*407*308mm
240VAC LOAD
HOT1&Hot2 G.W /
AC Input
N.W /
Utility
Inverter
Lighting Lighting Lighting Lighting Warranty One year (standard), 2 years optional (IP20)
112
Products / 120V
PH1100 LV Series
LV LV
RATED POWER 3600W 4000W
Nominal Battery System Voltage 48V
PV INPUT(DC)
3.6~4KW | Single Phase | 120VAC | IP65 Maximum recommended DC power 4600W 5200W
Nominal DC operating voltage 360V
Maximum DC voltage 500V
This is a flexible and intelligent energy storage solar inverter with a wide range
MPPT voltage range 120V~500V
of MPPT Voltage.
Combining functions of off grid and on grid. This hybrid solar inverter can Maximum input current 15A / 15A
power all kinds of appliances in home or office, and can also be used in power No.of MPP tracker 2
stations. Strings per MPP tracker 1
INVERTER OUTPUT(AC)
Nominal AC output power 3600W 4000W
Nominal output voltage; range 110/120/130V; 90~140V
AC grid frequency; range 50/60Hz; 45~55/55-65Hz
Nominal output current 30A 34A
■ Multiple operation modes: Grid-tie,off grid with storage backup Maximum output current 33A 36A
Inrush current (spike/duration) 72A/5.2us
■ IP65 water-proof and dust-proof
Total harmonic distortion i(THDi) <3%
■ MPPT voltage range 120-500V Power factor at rated power 1
■ Support LCD display&Smart LCD setting Displacement power factor 0.8leading ~ 0.8lagging
Grid type Single phase
■ Available Export control CT sensor function
BATTERY MODE OUTPUT(AC)
■ Multiple communications:USB,RS485,GPRS and wifi etc Output Rated Power 3600W 4000W
■ Full protection function:Over-voltage,over-frequency, over-current, Nominal output voltage; accuracy range 120±1%
over-temperature,and AC short-circuit automatic protection Output ferequency; accuracy range 50/60Hz (optional)±0.2%
■ Intelligent BMS battery management function Output rated current 30A 34A
Output waveform Pure sine wave
■ Fanless low-noise design
Peak power 5400W,10s 6000W,10s
■ Wifi monitoring Total harmonic distortion v (linear load) <3%
BATTERY & CHARGER
Back panel description Battery type Lead-acid battery / Lithium battery
Battery voltage 48V
Battery voltage range 40~60V
1 2 3 4 5 6 7 Charging curve 3-stage adaptive with maintenance
1. PV input terminals Protection Over-current protection / Over-temperature protection
2. Battery input terminals and cover Maximum charging power 3600W 4000W
3. Breather valve Maximum charging currernt 75A 85A
4. PV input switch EFFICIENCY
5. BTS terminals, BMS terminals, load monitor terminals, dry contact terminals, Maximum efficiency 97.1%
CAN communication terminals, USB terminal and cover Euro-efficiency 96.5%
6. Wi-Fi commodule MPPT efficiency 99.8%
7. AC output terminals and cover PROTECTION DEVICES
DC switch rating for each MPPT; Grid monitoring; Output over current protection; Output overvoltage protection-varistor; Ground fault monitoring;
Integrated all-pole sensitive leakage current
GENERAL
Machine Dimension (W*H*D) 480*420*215mm
Solar system connection Package Dimension (W*H*D) /
G.W 27kg
N.W /
DC connection H4 / MC4
AC connection Terminal Block
Display LED+LCD
Application Communication interfaces Wi-Fi / USB / GPRS / RS485
Ingress protection rating IP65
Solar Humidity 0~95% RH(No codensing)
Operating temperature range -20℃ +60℃ With derating above 45℃
Cooling concept Natural
Altitude <3000m
CERTIFICATION & STANDARDS
Grid CE-EMC+LVD (EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011); CE-LVD(EN62477-1:2022)
IEC60529; EN50549-1:2019
Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021)
C10/C11
UNE217001-2020; UNE217002-2020, NTS-631:2021 (Type A)
Battery (optional) Generator G98+G99
114
Products / 120V
PH1600 LV Series
Nominal Battery System Voltage 48V 48V 48V
INVERTER OUTPUT(AC)
Nominal AC output power 3000W 3500W 4000W
Nominal output voltage range 110/120,90~140 ±5VAC
3~4KW | Single Phase | 120VAC
AC grid frequency range 60Hz; 55-65Hz
The PH1600 LV Series is designed for retrofitting PV systems, including power Nominal output current 25A 29.1A 33.3A
classes ranging from 3kw to 4kw. It can be installed with existing PV inverters, Maximum output current 36.36A
forming an AC coupling system. Inrush current (spike/duration) 57.5A/5.2us
Capable of being grid-interactive, it allows users to store surplus power and
sell it back to the grid when demand peaks and the price of electricity is at its Total harmonic distortion i(THDi) @Nominal Output <3%
highest. It runs reliably under even the most extreme conditions with metal Power factor at rated power ≈1
aluminium housing with IP66 protection. Displacement power factor Adjustable from 0. 8 leading to 0. 8 lagging
Grid type Single phase
BATTERY MODE OUTPUT(AC)
Output Rated Power 3000W 3500W 4000W
Nominal output voltage; accuracy range 120±1%
■ LCD+LED – user friendly interface
Output ferequency; accuracy range 60Hz±0.2%
■ IP66 design for outdoor
Output rated current 25A 29.1A 33.3A
■ Compatible with other brands of inverter
Output waveform Pure sine wave
■ Various work mode for different application scenarios Peak power 3000VA, 10S 3500VA, 10S 4000VA, 10S
■ Natural cooling without external fan Total harmonic distortion v (linear load) <3%
■ BMS Function BATTERY & CHARGER
■ Wifi monitoring Battery type Lead-acid battery / Lithium battery
116
Products / 120V
PH1800 LV Series
LV LV LV
INVERTER OUTPUT
3~6KW | 120V | Wifi
Rated Power 3000W 3000W 6000W
PH1800 LV Series is a multi-function inverter/charger, combining functions
of inverter, MPPT solar charger and battery charger to offer uninterruptible Surge Power 6000W 6000W 12000W
power support with portable size. Its comprehensive LCD display offers user-
configurable and easy-accessible button operation such as battery charging Waveform Pure sine wave
current, AC/solar charger priority, and acceptable input voltage based on
different applications. AC Voltage Regulation (Batt.Mode) 120VAC ±5% 120VAC ±5% 240VAC ±5% (L-L)
///////////////////
Inverter
Generator Battery
118
Products / 120V
PURE SINE WAVE INVERTER PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15- PI15-
MODEL
PI1500 LV Series
0312 LV 0324 LV 0612 LV 0624 LV 1012 LV 1024 LV 1512 LV 1524 LV 2012 LV 2024 LV
BATTERY DC INPUT
Input Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC
300~2000W | 12V,24V | 120V Low Voltage Protect Delay 2 seconds
PI1500 series is a pure sine wave inverter, high frequency machine solution, the (PB) 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC 10.5VDC 21.0VDC
Low Voltage Warning
product is small size, the solution is reliable and stable, the main function is to (LI) 10.5VDC 21.0VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC 11.6VDC 23.2VDC
invert the DC 12VDC battery or 24VDC battery to AC 120VAC output, mainly
used for emergency use Electricity, car inverter, outdoor electricity and other (PB) 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC 11.5VDC 23.0VDC
Low Voltage Protect
occasions. (LI) 11.5VDC 23.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC 12.0VDC 24.0VDC
(PB) 12.5VDC 25.0VDC 12.5VDC 25.0VDC 12.5VDC 25.0VDC 12.5VDC 23.0VDC 12.5VDC 23.0VDC
Low Voltage Restoring
(LI) 12.5VDC 25.0VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC 12.8VDC 25.6VDC
(PB) 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC 14.7VDC 29.4VDC
Over Voltage Protect
■ Input Voltage 12V / 24V DC optional (LI) 14.7VDC 29.4VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC 14.5VDC 29.0VDC
■ Output Voltage 120V AC optional (PB) 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC 15.0VDC 30.0VDC
Over Voltage Restoring
■ Portable power for AC products, AC outlets for connecting multiple loads (LI) 15.0VDC 30.0VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC 14.8VDC 29.6VDC
■ High efficiency converts virtually all of the battery's power to AC Parameters: (PB) Lead-acid Battery / (Ll) 4 series (12V), 8 series (24V) LiFePO4 Lithium Battery Pack
■ Mounting brackets for convenient installation
INVERTER AC OUTPUT
■ Overload and over temperature shut down
Default Power 300W 600W 1000W 1500W 2000W
■ Low voltage and over voltage alarm/cut off
Peak Power 600W 1200W 2000W 3000W 4000W
■ Short circuit protection
Output AC Voltage 120V 120V 120V 120V 120V
Battery Input Protection Low Voltage Protection, Over Voltage Protection, Reverse Protection
MPPT Solar Chage LED Digital Display / Display Battery Voltage, Output Power, Output Voltage, Error Numbers
Controller
Inverter DC OUTPUT
12V/24V EFFICIENCY
Car cigarette lighter
(Load must lower 120W; Available for 300W only) Peak Conversion efficiency 91% 91% 90% 88% 90% 88% 90%
ENVIRONMENT
Laptop Lighting TV Fans
Protection Degree IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20
Altitude ≤3000m
DIMENSIONS
G.W (kg) 9.3kg (8pcs) 15kg (8pcs) 23kg (8pcs) 19kg (4pcs)
120
Products / Controller
CONTROLLER INPUT
12V / 24V / 48VDC (Auto detection); 36V (Setting)
MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an Maximum Solar Input 24V (VBAT) 145V
efficient, safe, multi-stage recharging process that prolongs battery life and Voltage 36V (VBAT) 145V
assures peak performance from a solar array. Each Charge Controller allows
customized battery recharging. 48V (VBAT) 145V
MECHANICAL SPECIFICATIONS
1 2 3 4 5 6
Package Dimension (W*H*D) / /
OTHER
122
Products / Controller
CONTROLLER INPUT
12V / 24V / 48VDC (Auto detection); 36V (Setting)
MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an Maximum Solar Input 24V (VBAT) 245V
efficient, safe, multi-stage recharging process that prolongs battery life and Voltage 36V (VBAT) 245V
assures peak performance from a solar array. Each Charge Controller allows
customized battery recharging. 48V (VBAT) 245V
MECHANICAL SPECIFICATIONS
1 2 3 4 5 6
Package Dimension (W*H*D) / /
OTHER
124
Products / Controller
PC1800A Series Nominal Battery System Voltage 12V / 24V (Auto detection)
CONTROLLER INPUT
30A, 40A | 12V,24V
Battery Voltage 12V/ 24V
This solar charge controller is an advanced solar charger with maximum power
point tracking. Applying intelligent MPPT algorithm, it allows solar charge Open circuit voltage 145V
controller to extract maximum power from solar arrays by finding the maximum
power point of the array. PV Array MPPT Voltage Range 60-130VDC
The MPPT battery charging process has been optimized for long battery life
12V 432W 576W
and improved system performance. Self-diagnostics and electronic error
Maximum Input Power
protections prevent damage when installation errors or system faults occur.
24V 864W 1152W
BATTERY
■ Advanced MPPT technology,with efficient no less than 99% Over-charging Voltage 15.5V / 30.0V
■ Maximum DC- DC conversion efficiency of 98%
Over-charging Comeback Voltage 14.5V / 29.5V
■ Battery temperature sensor(BTS) automatically provides temperature
compensation Automatic battery voltage detection Battery Defect Voltage 10.0V / 17.0V
■ Integrated intelligent slot compatible with 485 communication
Temperature Compensation Coefficient -5mv / ℃ /cell (25℃ vef)
GENERAL SPECIFICATION
1. LCD Display
2. Charging Indicator Radiating Mode Automatic cooling
3. Fault and waming indicator
4. Wiring fault indicator Solar high voltage disconnect/ Solar high voltage reconnect/ Battery high voltage disconnect
Protections
Battery high voltage reconnect/ High temperature disconnect/ High temperature reconnect
5. Operation button
6. PV connectors MECHANICAL SPECIFICATIONS
1
3 7. Battery connectors
4 Mounting Wall mount
2 8. Load connectors
5
9. Battery temperature sensor terminal Machine Dimension (W*H*D) 187*255*72mm
10. RS485 communication port
9 6 7 8 10
Package Dimension (W*H*D) /
G.W /
OTHER
Solar Panel
Enclosure IP30
Generator
UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)
CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010)
126
Products / Controller
PC1600A Series Nominal Battery System Voltage 12VDC / 24VDC (Auto Detection)
CONTROLLER INPUT
MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an PV Array MPPT 12V 16VDC~100VDC
efficient, safe, multi-stage recharging process that prolongs battery life and Voltage Range 24V 32VDC~130VDC
assures peak performance from a solar array. Each Charge Controller allows
Max 12V 300W 450W 600W
customized battery recharging.
PV Input Power 24V 600W 900W 1200W
BATTERY
2
9. The battery negative terminal LED Display Charge Voltage, Charge Current, Voltage of storage battery, Capacity of storage battery, Output current
10. The battery positive terminal
PV array short circuit, PV reverse polarity
6 3 11. PV array negative terminal
Battery reverse polarity, Over charging protrction
5 4 12. PV array positive terminal Alarm Protections
13. Communication network terminal Output short circuit protection
14. Remote external temerature terminal Low voltage protection for storage battery
MECHANICAL SPECIFICATIONS
128
Products / Controller
PC1800A Series Nominal Battery System Voltage 12V / 24V / 48VDC (Auto detection); 36V (Setting)
ELECTRICAL SPECIFICATIONS
Solar high voltage disconnect; Solar high voltage reconnect; Battery high voltage disconnect;
Protections
Battery high voltage reconnect; High temperature disconnect;High temperature reconnect
G.W /
PV input N.W /
TV Laptop Lighting Fans
Generator
UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)
CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010)
130