F-A: BOQ (WITH ENGINEER's ESTIMATE)

FIRE DETCTION & ALARM SYSTEM AIR COMPRESSOR HALL, 0916 DESTO
Conventional Fire Detection & Alarm System

Quantity Unit Total


S.N Description Unit Remarks
InstallSpare Total Price Price
1 FIRE DETECTION AND ALARM PANEL (CONVENTIONAL)
Supply, installation & commissioning of Fire Detection & Control Panel (Conventional),
(220VAC Main) with 3 zones. Equipped with battery 24VDC for 24Hours
standby backup supply. The Panel should be suitable for connecting Smoke, Heat,
Triple IR (Infrared Flame Detectors), Sounders and Flashers. The Panel should be
suitable for electrical actuation of Electric Solenoid Actuator, Fire Alarm Sounders No. 1 0 1 290,135 290,135 Annex: B
and Flasher output. S.N: 3
Each Control Panel should have option for Abort Switch & Manual Release Switch.
Each Control Panel should have option for Auto & Manual Operation.
Control Panel should have minimum 02 Line LCD Display.
All terminal should be gelvenically isolated i.e. short circuit, over load protection and
auxiliary Relay for auxiliary output. with spare EOL, Diodes, Resistance & Glass Fuses.
Panel should have preferably TCP/IP based communication facility or at least
(RS 232 or 485) communication ports.
Communicating Protocol with Data rate of Control Panel also require.

UK / USA / UL Listed
Make: Simplex, Fike, Hochiki, Tyco, Honeywell
2 HEAT DETECTOR
Supply, installation, testing & commissioning of Heat Detector, type "Rate of Rise"
temperature. Detector should be equipped with LED light for status condition, mounting No. 4 1 5 10,612 53,059 Annex: B
base and auxiliary contact. Detector should have provision to connect remote (external) S.N: 6
LED light for operating status. Operating voltage 15-30VDC and Operating temperature
range -40 to 80°C. The detector should be compatible with control Panel (item#1).
UK / USA / UL Listed
Make: Simplex, Fike, Hochiki, Tyco, Honeywell
3 PHOTO-ELECTRIC SMOKE DETECTOR
Supply, installation, testing & commissioning of Photo-electric Smoke Detectors.
The Detector should have LED light for status condition, mounting base and auxiliary No. 4 1 5 17,963 89,815 Annex: B
contact. Detector should have provision to connect remote (external) LED light for operating S.N: 5
status. Operating voltage 15-30VDC and Operating temperature range -40 to 80°C.
The detector should be compatible with control Panel (item#1).
UK / USA / UL Listed
Make: Simplex, Fike, Hochiki, Tyco, Honeywell
4 Manual Call Station
Supply, installation & commissioning of loop powered manual call stationwith integrated
short circuit isolator. No. 1 1 2 45,352 90,704 Annex:B
An alarm should be released when the manual call station is pressed. S.N: 8
Operating voltage 1VDC~30VDC.
Manual Call Station should be compatible with fire control panel.
UK / USA / UL Listed
Make: Simplex, Fike, Hochiki, Tyco, Honeywell
5 FIRE ALARM SOUNDER/FLASHER
Supply, installation, testing and commissioning of Two wire Fire Alarm Sounder/Flasher
as per standard EN54 (Part3). Sound output Level up to 90db with High/
Low and operating Current up to 6mA (Beacon). No. 3 1 4 30,717 122,870 Annex: B
Operating voltage 18VDC~35VDC.Operating Temperature up to 50°C. S.N: 12
The Sounder/Flasher should be compatible with control Panel (S.No# 1).
UK / USA / UL Listed
Make: Simplex, Fike, Hochiki, Tyco, Honeywell
6 FIRE RESISTANT CABLE (2-Core) 1.5mm 2
Supply, laying and testing of Control Cable between each device in Loop to "Control Panel". Mtr 150 20 170 650 110,500 Annex:A
Cable should be 1.5mm 2, 2-Core, Flexible, Fire Resistant PVC, Unarmored. Shielded, S.N: 7
Cu. Conductor.
UK / USA / UL Listed
Make: Firetuff, Leoni, Firecell, AS Cable or Approved as directed by Engineer Incharge.
Total Of Non Schedule Items 757,082.07

Page 1 of 3
Conventional Fire Detection & Alarm System

Quantity Unit Total


S.N Description Unit Remarks
InstallSpare Total Price Price
Part-B: Schedule Items
1 MS Seamless Pipe

Supply and installation of MS Seamless Pipe (Sch-20) for open laying of Two Core Cable Mtr 120 20 140 MES24-
548 76,720
445
throughout the Complex, with all fittings i.e. Sockets, Bends, Tees, Elbows, Barrel Nipples Junction
Boxes where required & to walls, floors & ceiling etc.
MS Seamless Pipe Size. 01 inch

Make: HUFFAZ or Approved Equivalent as diected by Engineer Incharge

2 Junction Box
Box junction circular, cast or malleable iron, stove enameled or galvanized complete with cover any
number of outlets 25mm dia,.S/F. No's 8 3 11 MES24-
142 1,562
562

Total Of Schedule Items 78,282.00


Grand Total Of Schedule Items & Non Schedule Items 835,364.07