ON and OFF times required to the outer edge of the fore, when in use as a general purpose timer, the

, the Drill the wall to suit the three backplate mounting


1. Set the Timer
dial. See Fig. 1.— to set ON at 7:30 a.m. and OFF manual switch functions as follows: holes b, c, & d. Do not mount the timer on an un-
Do not rotate the dial anti-clockwise as this will earthed metal or metallised surface.
at 10:30 a.m. move all tappets to In position 1, terminal 4 output is ON
damage the mechanism.
outer position between 07:30 and 10:30 on the Secure to wall surface using suitable wall plugs &
Rotate the minute hand clockwise until the arrow- In position 2, the output will switch between termi-
dial. Set any other ON/OFF times in a similar man- screws.
head on the clock face aligns with the correct time nals 4&5, as determined by tappet positions.
ner. Immersion Heater Control
on the outer dial—see Fig. 1. In position 3, terminal 5 output is ON.
Connect wiring according to the wiring diagram.
The dial shows the 24 hour clock. Note that 9 = 2. Manual Override See Fig. 4. When installing for immersion heater
9:00 a.m., 21 = 9:00 p.m. When setting-up the 7
Immersion Heater Timer 1 = ON control ensure the brass link is correctly positioned
day version, align correct time on outer dial, within
and retained as pre-fitted to terminals 2 & 3.
current day sector of dial. Please note: on the 2 = AUTO
There is a three-position manual selector built-in to
IHTGPW seven-day timer, the weekdays are print- General Purpose Control
the clock dial face. See Fig. 2.
ed around the edge of the dial in abbreviations of 3 = OFF
Removal of the brass link converts the timer switch
three languages. Leave the selector in the middle-position for auto- to a volt-free configuration.
To set ON / OFF times, move all tappets between matic control, when the output is ON or OFF ac- Figure 2. Secure cable and flex using clamps provided (see
cording to the tappet settings. To switch ON manu-
Fig. 5.) Do not connect unprepared stranded wires.
ally, move the selector to position 1 (marked I on
the dial). To switch OFF manually, move the selec-
3. Installation guide Use ferrules supplied to crimp stranded wire termi-
Installation must be carried out in accordance with nations.
tor to position 3 (marked 0 on the dial).
the current edition of the I.E.E. Wiring Regulations. Means of disconnection with minimum 3mm contact
The manual lever is a fixed selection. The output It is recommended that installation is undertaken separation in all poles must be incorporated in the
will stay as selected until the manual lever is moved only by a qualified electrician. fixed wiring mains supply.
once more.
Undo the recessed cross-head screws ‘a’ (see Fig. Push timeswitch module onto backplate, ensuring
General Purpose Timer 3). Lift off the outer housing. Grip the square base good engagement of tab terminals. Refit housing
of the timer and pull the timer away from the back- to backplate.
Figure 1. The timer incorporates a changeover switch. There- plate.
Wiring for general purpose use 4. Specification
(as a volt-free control)
Motor: 220-240V AC 50Hz
Time Switch
To convert the timer for volt-free applications, For immersion heater control
remove the brass link. Connect mains to terminals
Temperature rating T45
1 & 2 (not polarity conscious). Switching will occur Switch type: changeover and general purpose use
across terminals 3, 4 & 5. Rating:
Common - terminal 3 16A resistive / 8A inductive
User instructions
Normally open (ON) - terminal 4 Not suitable for direct switching of lighting
Normally closed (OFF) - terminal 5 types: HID, SON, LED—use a contactor OP-IHTGPT 24 Hour Synchronous
Figure 3.
Earth - Earth park terminal Min switching 15 minutes
Connection: Class II control / Protection class IP20
Supply: OP-IHTGPW 7 Day Synchronous
Complies with European Norm
Live - terminal 3 Min switching 2 hours
EN 60730-1: 2011
Neutral - terminal 1
Automatic Electrical Controls for
Load: (product version is shown on the rating label)
Household and similar use,
Live - terminal 4
and European Directives:
Neutral - terminal 1 1. Set the timer
LVD; EMC; RoHS
Link:
2. Manual override
Terminals 2 - 3
www.tfc-group.co.uk 3. Installation guide
Figure 4. Earth - Earth park Figure 5.
TFC Group LLP Tonbridge TN9 1TB 4. Specification
Wiring for immersion heater or mains-
switching applications