BUILDING CODE ACCESSIBILITY FIRE CODE LOW COST SUBDIVISION &
CODE HOUSING CODE CONDO
PD 1096 BP 344 RA 9514 BP 220 PD 957 DOORS General: 2.00m Minimum height 2.00m 2.00m 2.00m Bathroom/mezzanine: 1.80m Main door: 0.80m Minimum width 900mm 800mm 710mm Bedroom: 0.70m Bathroom: 0.60m Maximum width 1200mm 1220mm 820-1060mm Height of door knob (900mm preferred) LOCATION ON PROPERTY Front setback R1: 4.50m 1.50m Side setback R1: 2.00m 1.50m Follow NBC Rear setback R1: 2.00m 2.00m Distance of eaves from property line 0.75m 0.75m MINIMUM ROOM SIZES 6.00sqm Rooms for human habitation Minimum dimension of 2.00m 3.00sqm Kitchen Follow NBC Minimum dimension of 1.50m 1.20sqm Bathroom Minimum dimension of 0.90m MINIMUM AIR SPACE REQUIREMENTS 3.00 cubic meters (Allot 1.00 Schools sqm per person) Offices and factories 12.00 cubic meters Habitable rooms 14.00 cubic meters MINIMUM CEILING HEIGHTS Naturally ventilated: 2.70m Ground floor Artificially ventilated: 2.70m Naturally ventilated: 2.70m Second floor 2.00m Artificially ventilated: 2.40m 2.00m for walkways 2.00m for means of egress Naturally ventilated: 2.70m Succeeding floors Artificially ventilated: 2.10m Mezzanine 1.80m 1.80m LIGHT AND VENTILATION 10% of floor area, but 1.00sqm Windows for rooms 10% of floor area minimum 5% of floor area, but 240 sq. Windows for bathrooms 5% of floor area mm. minimum Minimum dimension of court 2.00m 2.00m Min. width of court passageway 1.20m 1.20m STAIRS Existing stairs: 205mm max. Riser 200mm maximum 250mm maximum New stairs: 100-180mm Existing stairs: 230mm min. Tread 250mm minimum Slanted nosing 200mm minimum New stairs: 280mm min. preferred over Less than 10 OL:0.75m Existing stairs: 915mm protruding nosing, 10-50 OL.: 0.90m New stairs, 0-49 OL: 915mm Minimum width provide 300mm-wide 600mm New stairs, 50-1999 OL: 1120mm More than 50 OL:1.10m tactile strip at top and New stairs, 2000 or more OL: 1420mm bottom of stairs. Minimum headroom 2.00m 2.00m 2.00m Maximum vertical distance between landings 3.60m 3.66m 3.60m Handrail height 800-900mm 760-865mm 800-1200mm RAMPS Maximum slope 1 in 12 1 in 12 Maximum cross slope 1 in 48 Minimum width No general requirements 1.20m 1120mm Minimum landing length provided, only for ramps 1.50m located in reviewing stands, 6.00m (horizontal Distance between landings grandstands and bleachers. distance bet. 760mm (vertical distance bet. landings) landings) Handrail height 700mm and 900mm 760-865mm CORRIDORS 1.10m 1.20m OCCUPANT LOADS (Area per person) Place of assembly 0.65 sqm Standing room 0.28 sqm Concentrated use 0.65 sqm Less concentrated use 1.40 sqm Educational Classrooms 1.80 sqm 1.90 sqm Shop, laboratories, vocational rooms 4.60 sqm 4.60 sqm Dry nurseries 3.30 sqm Conference rooms, exhibit rooms, gyms 1.40 sqm Healthcare Sleeping departments 11.00 sqm 11.10 sqm In-patient treatment 22.00 sqm 22.30sqm Hospitals, sanitaria 8.40 sqm Nursing homes 7.40 sqm Children's nurseries 3.25 sqm Residential 18.60 sqm Dwellings 28.00 sqm Hotels, apartments, dormitories 18.60 sqm Mercantile Street floor or basement used for sale 2.80 sqm 2.80 sqm Upper floors used for sale 5.60 sqm 5.60 sqm Floors not used for sale (office, storage, etc.) 9.30 sqm 9.30 sqm Drinking establishments 1.40 sqm Commercial kitchens 18.60 sqm FIREWALL EXTENSIONS Above roof 400mm 300mm For rowhouse: 300mm From outermost edges (walls) 600mm 300mm For rowhouse: 300mm Under eaves 300mm 300mm For rowhouse: 300mm EXITS 0-10 OL: 1 exit 0-500 OL: 2 exits 0-9 OL: 1 exit 10-499 OL: 2 exits Number of exits required (based on occupant load) 500-999 OL: 3 exits 501-999 OL: 3 exits 10 or more OL: 2 exits 1000 or more OL: 4 exits 1000 or more OL: 4 exits Minimum width of exits 1.10m (corridors) 915mm Additional note regarding exits: Maximum travel distance to exit, no sprinkler 45.00m BP 220 specifically refers to Section 3.1007 of PD 1185 (the Maximum travel distance to exit, with sprinkler 60.00m old Fire Code) for the exit Minimum width of exit door 900mm 800mm (for all doors) requirements. This is included in BP 220 as Annex 1 on page 53.
Minimum height of exit door 2.00m 2.00m (For all doors)
Change in floor level at doors 50mm 13mm Maximum length of dead ends Place of assembly 6.10m Educational 6.00m Healthcare 6.00m Provide turnabout Detention/correctional 6.00m 6.00m space within 3.50m of Residential (hotels/dormitories) 6.00m any dead end Residential (apartment buildings) Not allowed Business 6.00m Business, with NFPA 13 sprinkler system 15.00m Industrial 15.50m ELEVATORS In apartments or condomimiums 5 storeys or Inside dimensions of Required for healthcare occupancies two higher, at least 1 passenger car: 1.10m wide x storeys or higher. Required for multi-family elevator shall be kept on 24- 1.40m deep dwellings and hour constant service. Various elevator requirements condominiums 6 storeys of Follow NBC higher. Follow standards Minimum 600mm-deep pit Maximum travel in NBC and BP 344. distance from building Provide at least one exit per elevator lobby. entrance: 30.00m Maximum 4 cars per hoistway
(Archaeology in Society) Sophia Labadi - UNESCO, Cultural Heritage, and Outstanding Universal Value - Value-Based Analyses of The World Heritage and Intangible