0% found this document useful (0 votes)
53 views18 pages

ET1111

ET Format

Uploaded by

sagar patil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views18 pages

ET1111

ET Format

Uploaded by

sagar patil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

ET1111 Series Installation & Operation Manual

Installation and Operation Manual

ET1111 Series

Media Converter Series


Industrial 10/100BASE-TX to 100BASE-FX Ethernet Media
Converter

OT Systems Ltd., 2015


Rev 1.2

www.ot-systems.com 1
ET1111 Series Installation & Operation Manual

Models covered in this manual

Micro Type Wall-Mount


Fiber connector in SC Fiber connector in ST

Multi-Mode (2-Fiber) Multi-Mode (2-Fiber)


ET1111-A-MT ET1111-G-MT

Single-Mode (2-Fiber) Single-Mode (2-Fiber)


ET1111-B-MT ET1111-H-MT

Multi-Mode (1-Fiber) Multi-Mode (1-Fiber)


ET1111-C-MT ET1111-I-MT
ET1111-D-MT ET1111-J-MT

Single-Mode (1-Fiber) Single-Mode (1-Fiber)


ET1111-E-MT ET1111-K-MT
ET1111-F-MT ET1111-L-MT

www.ot-systems.com 2
ET1111 Series Installation & Operation Manual

Table of Contents

TABLE OF CONTENTS............................................................................................................................................... 3

(1) SAFETY INSTRUCTIONS .................................................................................................................................. 4

(2) PRODUCT OVERVIEW .................................................................................................................................... 5

2.1 INTRODUCTION ..................................................................................................................................................... 5


2.2 PRODUCTS HIGHLIGHTS .......................................................................................................................................... 5
2.3 MODELS SELECTION TABLE ...................................................................................................................................... 6

(3) INSTALLATION................................................................................................................................................ 7

3.1 GENERAL ............................................................................................................................................................. 7


3.2 PACKAGE CONTENTS .............................................................................................................................................. 7
3.3 SELECTING A SITE FOR THE MEDIA CONVERTER ............................................................................................................ 8
3.4 INSTALLATION ....................................................................................................................................................... 8
3.5 INSTALLATION- WALL MOUNT ................................................................................................................................. 9
3.6 CONNECTING TO POWER ........................................................................................................................................ 9
DC Terminal Block Power Input ....................................................................................................................... 9

(4) CABLE CONNECTIONS & SETUP PROCEDURES .............................................................................................. 10

4.1 SYSTEM CABLE CONNECTIONS ................................................................................................................................ 10


4.2 CONNECTING TO YOUR NETWORK .......................................................................................................................... 11
4.2.3 The 10/100Base-TX Connector/Cabling ........................................................................................ 11
4.2.4 The 100Base-FX Connectors........................................................................................................... 12

(5) OPERATIONAL GUIDES ................................................................................................................................. 13

5.1 LEDS STATUS...................................................................................................................................................... 13


5.2 SIGNAL AND POWER PORTS................................................................................................................................... 13

(6) SPECIFICATIONS ........................................................................................................................................... 14

(7) DRAWINGS .................................................................................................................................................. 16

(8) WARRANTY INFORMATION ......................................................................................................................... 16

(9) CONTACT INFORMATION ............................................................................................................................. 17

APPENDIX A............................................................................................................................................................ A

1. CONNECTOR PINOUTS ................................................................................................................................... A

www.ot-systems.com 3
ET1111 Series Installation & Operation Manual

(1) Safety Instructions


Please be familiar with all information in this manual prior to installation and
operation.

Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following
safety precautions apply.

Warning: Do not disconnect the fiber optic connector while the unit is powered up.
Exposure to Class I invisible optical radiation is possible when the internal fiber optic
connector is disconnected while the unit is powered up.

Caution: Any access to the controls, adjustments, or performing operations, which are
other than those specified, may result in hazardous radiation exposure. Permanent eye
damage or other bodily injuries may be resulted from such exposure even for only
seconds.

Note 2: This assembly contains parts sensitive to damage by electrostatic discharge (ESD). ESD
precautionary procedures should be applied in the course of touching, removing or inserting parts
or assemblies.

www.ot-systems.com 4
ET1111 Series Installation & Operation Manual

(2) Product Overview

2.1 Introduction
OT Systems' ET1111 media converter offers an easy and affordable solution for network
managers to connect 10/100 Fast Ethernet from UTP to fiber optic cabling. The media converter
series uses a high performance auto-sensing exchange chip for full functionality of transfer and
exchange, guaranteeing the safety and stability of data transfer. The media converter is available
in both single-mode and multi-mode fiber.
This Sleek Microtype design media converter occupies limited space and it's ideal solution for
easy installation within most camera housings.

2.2 Products Highlights


Basic Features
 Microtype design - fits within most camera housings
 Converts 10/100Base-TX to 100Base-FX
 Full/Half duplex, Auto-Negotiation
 Singlemode or Multimode fiber operation
 Single or Dual-core fiber with SC or ST connectors
 Store and forward switching mechanism
 MDI/MDI-X Auto-Crossover supported
 Plug-and-Play
 12VDC or 24VAC Terminal Block Power inputs
 -10 °C to 60 °C (14 °F to 140 °F) operating temperature
 Supports Wall Mounting installation.

www.ot-systems.com 5
ET1111 Series Installation & Operation Manual

2.3 Models selection table

Descriptions

Models
Links Max.
Fiber Options Wavelengths Mounting
Budget Distance

ET1111-A-MT Multimode/2-fiber/SC 1310nm 14dB 2Km


ET1111-B-MT Singlemode/2-fiber/SC 1310nm 21dB 20Km
ET1111-C-MT Multimode/WDM 1-fiber/SC TX:1310nm/RX1550nm 21dB 2Km
ET1111-D-MT Multimode/WDM 1-fiber/SC TX:1550nm/RX1310nm 21dB 2Km
ET1111-E-MT Singlemode/WDM 1-fiber/SC TX:1310nm/RX1550nm 19dB 20Km
ET1111-F-MT Singlemode/WDM 1-fiber/SC TX:1550nm/RX1310nm 19dB 20Km Micro Type
ET1111-G-MT Multimode/2-fiber/ST 1310nm 14dB 2Km Wall-mount
ET1111-H-MT Singlemode/2-fiber/ST 1310nm 21dB 20Km
ET1111-I-MT Multimode/WDM 1-fiber/ST TX:1310nm/RX1550nm 21dB 2Km
ET1111-J-MT Multimode/WDM 1-fiber/ST TX:1550nm/RX1310nm 21dB 2Km
ET1111-K-MT Singlemode/WDM 1-fiber/ST TX:1310nm/RX1550nm 19dB 20Km
ET1111-L-MT Singlemode/WDM 1-fiber/ST TX:1550nm/RX1310nm 19dB 20Km

www.ot-systems.com 6
ET1111 Series Installation & Operation Manual

(3) Installation

3.1 General
All OT Systems products are thoroughly inspected, tested and securely packaged before
delivery to ensure a stable, intact and trouble-free service. Please check the equipment upon
receipt for any visible damage which may have been caused during shipping.

3.2 Package Contents


When you unpack the product package, you shall find the items listed below. Please inspect
the contents, and report any apparent damage or missing items immediately to your authorized
reseller.

 Media Converter
 Quick Installation Guide
 External 12VDC power adapter & Power Cord

The ET1111 Series (Fig. 3.1) can be either horizontally or vertically wall-mounted, or fits
within the most camera housings, etc. It works with an external 12VDC or 24VAC power supply.

Fig. 3.1 ET1111

www.ot-systems.com 7
ET1111 Series Installation & Operation Manual

3.3 Selecting a site for the Media Converter


As with any electric device, you should place the Media Converter where it will not be
subjected to extreme temperatures, humidity, or electromagnetic interference.
Specifically, the site you select should meet the following requirements:

- The ambient temperature should be between -10 to +60 degrees Celsius.


- The relative humidity should be less than 95 percent, non-condensing.
- Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards.
- Make sure that the Media Converter receives adequate ventilation.
- The power outlet should be within 1.8 meters of the Media Converter.

3.4 Installation
This chapter gives step-by-step instructions about how to install the Media Converter:

a) Mount the ET1111 onto a fixture or camera housings, e.g. a plank, (either on the
wall or on a flat surface) with two screws through the holes on the mounting
frame to secure it in position.
b) The power supply should also be mounted on the same fixture or in the proximity
for connection of the supply cables to the unit, provided that an AC power supply
socket is nearby for powering the adaptor.
c) Connect all the signal inputs and outputs at the unit with appropriate cables: fiber
optic cable for optical link and UTP/STP Cat 5 cable for Ethernet. Please refer to
Section 4.1 for the details.
d) Once the unit is powered up, check that the POWER LED on the unit is lit. If not,
check the power supply cable connections between the unit and the power
supply socket.
e) With all the signals available at the physical ports, check the status of LEDs
located on the unit. With correct status of each LED, installation is now completed
[for LEDs status, see Operational Guides on this manual’s Section (5)].

www.ot-systems.com 8
ET1111 Series Installation & Operation Manual

3.5 Installation- Wall Mount

(a) Top view (b) Side view


Fig. 3.2 Dimension of Micro type units

 Installation: Mount the Micro type unit onto a fixture, or camera housings, e.g. a
plank, (either on the wall or on a flat surface) with at least 2 screws piercing through
the holes on the mounting frame to secure it in position.
 Startup: Connect the supply voltage to start up the Media Converter via the terminal
block.
 Removal: Locate and remove the securing screws. Usually, but not limited to, at
least 2 screws.

3.6 Connecting to Power

Bottom panel – Ethernet Port and Power


Input

Ethernet Port
NETWORK - RJ45
connector
Power Input Assignment
Top Panel Bottom Panel 12VDC 1 GND Terminal
2 12V Block

DC Terminal Block Power Input


Step 1: Connect the DC power cord to the pluggable terminal block on the bottom of
Media Converter and then plug it into a standard DC outlet.
Step 2: Disconnect the power cord if you want to shut down the Media Converter.

www.ot-systems.com 9
ET1111 Series Installation & Operation Manual

(4) Cable Connections & Setup Procedures

4.1 System cable connections


Signal Cable Type Connector For details,
Type please refer to
Optical Single-mode or Multi-mode fiber SC or ST Connector Section 4.2.2
Ethernet Twisted-pair Cable RJ45 Connector Section 4.2.1
10BASE-T: UTP/STP Cat3, 4, 5
100BASE-TX: UTP/STP Cat 5
12VDC Power cord Terminal Block Section 3.6
Or
24VAC

Wiring Diagram

Fig 4.1 Media converter connection diagram

www.ot-systems.com 10
ET1111 Series Installation & Operation Manual

4.2 Connecting to Your Network


4.2.1 Cable Type & Length
It is necessary to follow the cable specifications below when connecting the Media
Converter to your network. Use appropriate cables that meet your speed and cabling
requirements.
Cable Specifications
Speed Connector Port Speed Cable Max.
Half/Full Duplex Distance
10Base-T RJ-45 10/20 Mbps 2-pair UTP/STP Cat. 3, 4, 5 100 m
100Base-TX RJ-45 100/200 Mbps 2-pair UTP/STP Cat. 5 100 m
100Base-FX SC, ST 100/200 Mbps MMF (62.5μm) 2 km
100Base-FX SC, ST 100/200 Mbps SMF (9 or 10μm) 20km

4.2.2 Cabling
Step 1: First, ensure the power of the Media Converter and end devices are turned off.
<Note> Always ensure that the power is off before any installation.
Step 2: Prepare cable with corresponding connectors for each type of port in use.
Step 3: Consult the cabling requirements based on connectors and speed.
Step 4: Connect one end of the cable to the Media Converter and the other end to a desired device.
Step 5: Once the connections between two end devices are made successfully, turn on the power and the
Media Converter is operational.

4.2.3 The 10/100Base-TX Connector/Cabling


A standard straight through cable is used for the connection between the Ethernet switch and
device. The products feature an auto-MDIX capability. For the details, Please see Appendix A for
your reference.

www.ot-systems.com 11
ET1111 Series Installation & Operation Manual

4.2.4 The 100Base-FX Connectors


The 100Base-FX Connections
The fiber port pinouts
The TX (transmit) port of device I is connected to the RX (receive) port of device II, and
the RX (receive) port of device I to the TX (transmit) port of device II.

X value:
A for Multimode fiber
B for Singlemode fiber
FIBER Connector
TX SC Optical Connector
RX SC Optical Connector

X value:
G for Multimode fiber
H for Singlemode fiber
FIBER Connector
TX ST Optical Connector
RX ST Optical Connector

The WDM 100Base-FX Connections


The fiber port pinouts
Only ONE optical fiber core is required to transmit and receive data.
* Special note for choosing WDM products:

Pair of products should be used for the optical transmission by different wavelengths (1310nm, 1550nm).
i.e. ET1111-C-MT should be match with ET1111-D-MT;
ET1111-E-MT should be match with ET1111-F-MT;
ET1111-I-MT should be match with ET1111-J-MT;
ET1111-K-MT should be match with ET1111-L-MT.

X value:
C and D for Multimode fiber
H and F for Singlemode fiber
FIBER Connector
SC Optical Connector

X value:
I and J for Multimode fiber
K and L for Singlemode fiber
FIBER Connector
ST Optical Connector

www.ot-systems.com 12
ET1111 Series Installation & Operation Manual

(5) Operational Guides


5.1 LEDs Status

LED State Indication

PWR Green Power on.

Off Power off.

FX LINK Green 100Base-FX

SPD Green 100Base-TX

Off 10Base-TX

LINK/ Steady A valid network connection established


ACT
Flashing Transmitting or receiving data.

ACT Stands for Activity.

5.2 Signal and Power Ports


FIBER - SC or ST Optical Connector(s) for 100BASE-FX fiber cable connection.
NETWORK - RJ45 with Cat. 5 for 10/100BASE-TX Ethernet connection.
DC12V- 2-pin Screw Terminal Block for 12VDC or 24VAC power connection.
AC24V -

www.ot-systems.com 13
ET1111 Series Installation & Operation Manual

(6) Specifications
Ethernet
Standards IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX/FX
IEEE 802.3x
Address table size 2048MAC addresses
Processing Type Store-and-Forward
Half-duplex and IEEE802.3x Full-duplex flow control
Forward and Filter Rate
10Base-T 10 / 20Mbps half / full-duplex
100Base-TX/FX 100 / 200Mbps half / full-duplex
Cabling
10BASE-T UTP/STP Cat. 3, 4, 5 or above
100BASE-TX UTP/STP Cat. 5 or above
Maximum Distance
Cat5 UTP Up to 100m
Connector
10/100BASE-TX 1X RJ45

Optical
Cabling 62.5/125μm (Multi-mode)
9/125μm (Single-mode)
Maximum Distance
Multi-mode fiber 2Km
Single-mode fiber 20Km
Wavelength(s) 1310nm
1310/1550nm
Connector SC or ST

Electrical and Mechanical


Input Power 12VDC or 24VAC (Terminal Block)

Power Consumption 2.4W Max.


Operating Voltage & Max. 0.2A @ 12VDC
Current Consumption

www.ot-systems.com 14
ET1111 Series Installation & Operation Manual

LED Indicators
Power Power Status
10/100 TX (Per Port) Link/Activity, Speed
100FX (Per Port) Link/Activity
Dimensions 36.2mm (W) × 98mm (D) × 24.5mm (H)
Net Weight 0.12Kg (0.22kg including PA)
Casing Aluminum case
Mounting Options Wall-Mount

Environmental
Operating Temperature -10°C to 60°C (14°F to 140°F)
Storage Temperature -25°C to 85°C (-13°F to 185°F)
Humidity 0% - 95% non-condensing

Regulatory Approvals
ISO9001
FCC Part 15, Class A
EN61000-3-2: 2006
EN61000-3-3: 2008
EN55024: 1998 +A1:2001+A2:2003

www.ot-systems.com 15
ET1111 Series Installation & Operation Manual

(7) Drawings

Fig. 7.1 Dimensional drawings of ET1111 (mm)

(8) Warranty Information


All OT Systems ET Series products are subject to a three-year limited warranty offered by
the company in normal circumstances. Please refer to the OT Systems Products Warranty
Statement for details. Access to the statement is available in our company website at
www.ot-systems.com.

www.ot-systems.com 16
ET1111 Series Installation & Operation Manual

(9) Contact Information


APAC Operation EMEA Operation AMERICAS Operation
Address: Address: Address:
Unit 1023, 10/F, Landmark North, J. Slovackio str. 4, LT-11107, 18 West Main Street, Plano,
39 Lung Sum Avenue, Sheung Vilnius, Lithuania IL 60545, U.S.A.
Shui, N.T., Hong Kong
Tel: (852) 2672 5153 Tel: (370) 60730087 Tel: (1) 630 554 9178
Fax: (852) 2679 0756 Fax: (370) 52051855 Fax: (1) 630 554 9179
Sales Inquiries Sales Inquiries Sales Inquiries
[email protected] [email protected] [email protected]
Technical Support Technical Support Technical Support
[email protected] [email protected] [email protected]

www.ot-systems.com 17
ET1111 Series Installation & Operation Manual

Appendix A

1. Connector Pinouts

RJ45 Connector (Male) RJ45 Connector (Female)

2. TIA/EIA-568 Cabling
T568A T568B
RJ45
Pin # Wire Diagram 10Base-T Signal 10Base-T Signal
Wire Color Wire Diagram Wire Color
100Base-TX Signal 100Base-TX Signal
1 White/Green Transmit+ White/Orange Transmit+
2 Green Transmit- Orange Transmit-
3 White/Orange Receive+ White/Green Receive+
4 Blue Unused Blue Unused
5 White/Blue Unused White/Blue Unused
6 Orange Receive- Green Receive-
7 White/Brown Unused White/Brown Unused
8 Brown Unused Brown Unused

3. Standard, Straight-Through Wiring Diagram(both ends are the same):


The Straight-Through wiring (or called “regular” Ethernet cable), both ends should be use the
same pin out on of RJ45 port.

www.ot-systems.com A

You might also like