Veraviewepocs 2D

Thinking ahead. Focused on life.


Veraviewepocs 2D
The New Frontier of X-ray

MORITA‘s cutting edge technology produces 2D images of superior quality with high
resolution and low X-ray exposure.
The Veraviewepocs 2D features a variety of specialized programs, such as the
Orthoradial Panoramic projection, which reduces the overlapping of neighboring
teeth, and Shadow Reduction Panoramic projection, which reduces obstructing
shadows, as well as the AF (Auto-focus) function for accurate patient positioning.

2 3
Panoramic

Conventional Image

Automatic Image Enhancer comparison

Automatic Image
Super High Quality Image
Enhancement (AIE)
Veraviewepocs produces high resolution even in High Speed Mode. The resulting image offers superb density and contrast. Automatic Image
Digital Direct AE (Automatic Exposure) and Automatic Image Enhancement combine to give you the optimal image. Enhancement enhances the
details that can be observed
in areas which are either
extremely light or extremely
dark. DDAE and AIE perform
144 µm CPU
a logarithmic conversion to
produce the highest quality
image possible.
96 µm

Sensor
Fine High Speed Mode: pixel size 144 μm X-ray Head
Super Fine Mode: pixel size 96 μm

High Resolution Digital Direct Automatic Exposure (DDAE)


Fine High Speed Mode: DDAE adjusts the X-ray tube current (mA) dynamically by
At a pixel size of 144 μm, it produces superior high resolution images. detecting X-rays passing through the patient. This improves
the dynamic range, and, along with Automatic Exposure (AE),
Super Fine Mode: results in exceptionally clear images with the best possible
Produces an even better image with increased resolution. contrast and density. The automatic exposure level can be
adjusted to meet your individual requirements.

4 5
Panoramic

Standard Panoramic, Mag.: 1.3 x constant TMJ 4 Views, Mag.: 1.3 x constant
The thick/specially-designed image layer accommodates all the possible variations of dental Sharp, clear images of the TMJ are produced by aligning the angle of X-ray
arch shapes and sizes to produce extremely clear and sharp images. penetration with the longitudinal axis of the mandibular condyle head.

Pedodontic Panoramic, Mag.: 1.3 x constant (Mag.: 1.6 x is also available) Maxillary Sinus Panoramic, posterior Mag.: 1.5 x constant
For children or people with small jaws. The arm‘s rotation range is
reduced, and thus reduces X-ray exposure.

6 7
Panoramic Cephalometric

Standard Panoramic, Shadow Reduction


Mag.: 1.3 x constant Panoramic,
The thick/specially-designed Mag.: 1.3 x constant
image layer accommodates (Mag.: 1.6 x is also available)
all the possible variations of Produces images with less
dental arch shapes and sizes mandibular ramus shadow.
to produce extremely clear
and sharp images.

Light emitter

Orthoradial Panoramic, PSD sensor


Mag.: 1.3 x constant
(Mag.: 1.6 x is also available)
The perpendicular projection AF Automatic Positioning LA
of the X-ray reduces the
amount of overlapping with The light beam sensor automatically positions the C-arm Patient health first: only 1/10* X-ray exposure
emphasis on the maxillar without requiring the patient to move. It then measures the With only a tenth of the X-ray radiation, the radiation exposure is reduced significantly compared with conventional X-rays.
bicuspid region. distance to the patient's anterior teeth and AF automatically
moves the C-arm into the optimal position. This creates High quality images with a wide dynamic range
images with a high degree of reproducibility. Far more information about hard and soft tissue is received with just a single acquisition.

The semiconductor position detector (PSD sensor) measures distance with Fine High Speed CCD digital cephalometric
an extreme accuracy of 0.2 mm for high reproducibility. AF makes positioning High quality images in only 4.9 seconds.
easy and precise.
Variable image processing techniques are used to generate an impressive grayscale range.

* This comparison is made with the Veraviewepocs film-based system


8 9
Specification

Veraviewepocs 2D
Panoramic

960 mm (38-3/4")

2,355 mm (92-3/4")
max. 1,330 mm (52-3/8")
max. 1,380 mm (54-3/8")

EX-1: 96 mm (3-3/4")
1,500 mm (59")

40 mm (1-1/2") EX-2: 70 mm (2-3/4")

max. 1,775 mm (69-7/8")


min.1,055 mm (41-1/2")
115 mm (4-1/2")
max. 1,020 mm (40-1/8")

730 mm (28-3/4")

Panoramic Small Base Panoramic Panoramic/Cephalometric


1,500 mm (59")
Trade name Veraviewepocs 2D
Model X550
Type 2DA 2DB
Cassette Pan Pan/Ceph
Veraviewepocs 2D Input voltage EX-1: AC 120V 60 Hz, EX-2: 220/230/240 V 50/60 Hz
Panoramic/Cephalometric
Power consumption 2.0 kVA

1,490 mm (58-5/8") 510 mm (20")


X-ray generator
Tube voltage 60–80 kV
Tube current 1–10 mA
Effective focal spot 0.5 mm
2,355 mm (92-3/4")

Panoramic
845 mm (33-1/4")

Exposure time Fine high-speed mode approx. 7.4 seconds, Super fine mode approx. 15 seconds
max. 1,380 mm (54-3/8")
max. 1,330 mm (52-3/8")

Magnification ratio 1.3, 1.5, 1.6


1,500 mm (59")

Positioning Electric motor and AF optical distance sensor


max. 1,775 mm (69-7/8")
min. 1,125 mm (44-1/4")

Cephalometric
Imaging area — LA 225 x 254 mm, PA 225 x 203 mm
Magnification ratio — 1.1
max. 1,020 mm (40-1/8") Dimensions
W 1,020 x D 1,330 x H 2,355 mm W 2,000 x D 1,330 x H 2,355 mm
Main unit
(W 40-1/8“ x D 52-3/8“ x H 92-3/4“) (W 78-3/4“ x D 52-3/8“ x H 92-3/4“)
2,300 mm (90-1/2") Control box W 70 x D 40 x H 115 mm (W 2-3/4“ x D 1-1/2“ x H 4-1/2“)
Installation area 1.35 m2 (14.53 sf) 2.60 m2 (27.99 sf)
Weight Approx. 190 kg (418 lb.) Approx. 258 kg (568 lb.)

10 11
Diagnostic and Imaging Equipment

Treatment Units

Handpieces and Instruments

Endodontic System

Laser Equipment
Development and Manufacturing
J. MORITA MFG. CORP.
Laboratory Devices
680 Higashihama Minami-cho, Fushimi-ku,
Kyoto 612-8533, Japan
T +81. (0)75. 611 2141, F +81. (0)75. 622 4595 Educational and Training Systems
Morita Global Website
www.morita.com Auxiliaries
Distribution
J. MORITA CORP.
3-33-18 Tarumi-cho, Suita-shi, Osaka 564-8650, Japan
T +81. (0)6. 6380 1521, F +81. (0)6. 6380 0585

J. MORITA USA, INC.


9 Mason, lrvine CA 92618, USA
T +1. 949. 581 9600, F +1. 949. 581 8811

J. MORITA EUROPE GMBH


Justus-von-Liebig-Strasse 27b, 63128 Dietzenbach, Germany
T +49. (0)6074. 836 0, F +49. (0)6074. 836 299

MORITA DENTAL ASIA PTE. LTD.


150 Kampong Ampat
#06-01A KA Centre, Singapore 368324
T +65. 6779. 4795, F +65. 6777. 2279

J. MORITA CORP. AUSTRALIA & NEW ZEALAND


Suite 2.05, 247 Coward Street, Mascot NSW 2020, Australia
T +61. (0)2. 9667 3555, F +61. (0)2. 9667 3577

J. MORITA CORP. MIDDLE EAST


4 Tag Al Roasaa, Apartment 902, Saba Pacha 21311 Alexandria, Egypt
T +20. (0)3. 58 222 94, F +20. (0)3. 58 222 96

J. MORITA CORP. INDIA


Filix Office No.908, L.B.S. Marg, Opp. Asian Paints, Bhandup (West), Mumbai 400078, India
T +91-22-2595-3482

J. MORITA MFG. CORP. INDONESIA


28F, DBS Bank Tower, Jl. Prof. Dr. Satrio Kav. 3-5, Jakarta 12940, Indonesia
T +62-21-2988-8332, F + 62-21-2988-8201

SIAMDENT CO., LTD.


71/10 Mu 5, Thakham, Bangpakong, Chachuengsao 24130, Thailand
T +66. 38. 573042, F +66. 38. 573043
www.siamdent.com

Subject to technical changes and errors.

Pub: No. DI165-B00003-EN-3 JME EN0421