2/MTT/PM/F05
ELECTRONICA MTT - SERVICE DEPT.
E FANUC SYSTEM -
G CATEGORY - WW / OW / SC
H E & C DATE -
0.20
0.20
PAGE - 2/7
9 Tighten all screws on all terminal strips,
MCBs, contactors, OLRs, Relay
sockets,SMPS & Transformers,
switches etc inside the electrical cabinet
.
0.20
10 Tighten all electrical connections inside
the oil cooler unit . 0.20
11 Check shielding of all feedback cables
are properly grounded .
0.10
12 Check contactor OLRs are set
according to motor current for the
following -
Hydraulic motor
Lubrication motor
Coolant motor
Chip conveyor motor
Oil mist motor
Base coolant motor
Flood coolant motor
Tsc motor
ATC motor
Magazine motor.
Spindle oil cooler motor
0.40
13 Check tightness of all allied connectors
0.15
14 Check tightness of all connectors on
fanuc system.
0.10
15 Check 3 phse 415V mains input supply
to stabiliser
0.05
16 Check stabiliser output voltage & adjust
If nesessary to +/- 1%
0.10
17 Check voltage between earth & neutral
inside panel. It should less than 3 volts
0.05
18 Check main earthing connection is
proper. 0.05
19 Check wetness of earthpit
PAGE - 4/7
0.10
34 Check condition of hyd. Hoses, if
required replace it
0.05
35 Check function of pressure setting
valves are working.
0.05
36 Clean the Tank of lub.unit & spindle oil
cooler unit .
0.25
37 Clean the inlet suction filters
0.10
38 Check the lub. Oil quality as per the
specifications. 0.05
39 Check lub oil level, if required refill it.
0.10
40 Replace the oil of sp. Cooler unit -
frequency 6 months .
0.30
41 Check all the lub. Points at sliding
surfaces and ball screws for its
functionality
0.45
42 Check lub. Pressure is set as per
norms if not set accordingly.
0.10
PAGE - 5/7
43 Check float switch and pressure switch
operation 0.05
44 Check oil leakage if any from all lub.
Points. if so,rectify leakage points.
0.05
45 Check nylon pipes are intact.
0.05
46 Check for auto lub. Cycle is working as
per the ON & OFF timer set values. 0.05
47 Check the temp of oil cooler unit is
maintaining. If required set temp on oil
cooler unit .
0.10
48 Check over the piping conditions of the
air and coolant circuits .
0.10
49 Check whether any Coolant leakage
between the guards or not .
0.20
50 Check condition of belts.
0.10
51 Check axis movement is smooth.
0.05
52 Check back lash for all the three axis. If X=
required adjust in parameters. Pl Y=
specify backlash values under
observation column Z=
0.20
53 Check and clean wipers of slides 0.30
54 Check any abnormal noise from slide 0.05
55 movement
Tighten the/ all
ball screws
axis / motors to
gibs properly 1.00
assure best operating conditions.
0.10
72 Set all proximity switches as per APC
cycle.
0.15
73
Check whether customer has
maitained the extra copy of all the
documents in safe custody.
PAGE - 7/7
NOTE : - IF THE M/C IS EVER BEEN MOVED & ACCURACY, PRALLELISM, SQURENESS,
SP.RUNOUT, POSITIONING ACCURACY ETC. ARE FOUND DISTURBED . THE SAME WILL
NOT BE COVERED UNDER PREVENTIVE MAINT. FOR SETTING THE SAME SEPARATE
ACTIVITY HAS TO BE PLANNED ON CHAREABLE BASIS.,
1)
2)
3)
4)