BLOkon 03 Operating Manual Single Station
BLOkon 03 Operating Manual Single Station
BLOkon 03 Manual
OPERATING MANUAL
FOR CONTROL
SYSTEM OF BLOW
MOLDING MACHINE
Page 1 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
Business Mission
Streamline Controls Pvt. Ltd. (SCPL) is in the business of providing electronic &
computerized automation solution for different industries so as to enhance the
quality and productivity. Our motto is to provide indigenous, reliable and proven
products & hence to ensure consistent performance. Our concept of value to the
customers is to supply indigenous control systems designed with latest
technology, developed through extensive R & D, incorporating state of art
technology (world technology trend), manufactured under strictest quality control
system and duly tested, at competitive prices, delivered in time and supported by
service teams.
Ph.No. – 9328808665,,9328808669
E-mail –
[email protected]
web - www.streamlinecontrols.com
Page 2 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
PREFACE
BLOkon is multi functional controller incorporating micro controller, making it most versatile and
cost effective solution optimally designed to best suit the automation needs of blow molding machines.
For letter usage and maintenance of control system, detail study of this operating manual will be
helpful.
Page 3 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
CONTENTS
(B) INTRODUCTION
(C) FEATURES
(H) PRECAUTIONS
Page 4 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
(A) SPECIFICATIONS:
Input
Power:
Voltage -- 0-24Vac
Frequency -- 49-50 Hz
Consumption -- 30 VA Max.
Control:
Thermocouple -- J / K type - Isolated
Proximity/ -- NPN (NO type)
Limit switches 10-30Vdc - 50mA Max.
Output
Environment
Page 5 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
(B) INTRODUCTION
Blokon is a complete proven & reliable control system for Blow Molding Machine.
System consists of two units.
(1) MMI unit
(2) C.V.T. (Optional)/Transformer
This package has some obvious advantages over existing conventional Electrical
Systems. This occupies lesser space then conventional system. The simplicity of wiring from
solenoids to systems or limit switches to system and from Thermocouples to system makes it
easier and less time consuming for commissioning. This system has no moving parts, so
periodical maintenance is drastically reduced and there for reliability is definitely improved.
Function like Heating ON-OFF and Cycle Time Interlock makes this system much more superior
then the conventional system.
(C) FEATURES
Page 6 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
Operating Panel Description :
Front key board Sticker
Page 7 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
Key’s Description
1. Cursor Key
Press this key to move cursor from left to right direction for parameter
Setting in any menu.
Also use to open the password menu in online display
For Data input confirmation, save parameter & shift to next parameter.
Also Use to scroll online display.
Page 8 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
2. Manu Selector
Page 9 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
Blowing Key
Press for activate of blowing action manually.
Ejector Backward Key
Press for activate of Ejector Backward action manually.
Page 10 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
5. Common Function
Cutter Key
Press for activate of Cutter Left/Right action manually.
Parison Key
Press for activate of Extruder UP/Down action manually.
Page 11 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
(H) PRECAUTIONS
Equipment must be operating under correct power.(Install a voltage stabilizer while need)
All electrical elements with EARTH terminal, it is necessary for users to connect with the EARTH
terminal.
The high power cables should be separated from the low power cables to avoid interfere.
To prevent fire or hazard shock, do not expose the unit to rain or moistly place.
Thermocouples used for this system must be isolated (ungrounded) Fe/k type.
The wiring of each zone starting from thermocouple of heater must be verified.
For ex: first zone thermocouple must be connected to first channel of the system and heater of
first zone must be connected to heater 1of the system.
The limit switch and solenoids wiring must be done as per given wiring diagram.
If the proximity switches are used then use only PNP-NO type proximity switches.
Page 12 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
(I) Online View Screen
Page 13 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
View Screen 2
Page 14 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
View Screen 3
To go this page press save key in view screen2
1 2
10 12 14
9 11 13
Description of Page
Page 15 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
View Screen 5
To go this page press save key in view screen4
1 2
9 10 11
Description of Page
Page 16 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
View Screen 6
This page is useful to view the presence of each input. (Limit switch Or proximity
switch or push button)
Changes in the input status as per sensing of input indicates that the wiring and
electronic path of that input is functioning correctly.
Press save key once again to exit from VIEW: INPUT & enter in next page
View Screen 7
When any output is activated, Number is shown on LCD opposite activated output
number in digital output block. Please refer list of outputs for more information.
Press Save key once again to exit from VIEW: OUTPUTS & enter in Next Page
Page 17 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
Password Entry
Press Shift key in any of online display.
It is require to exit from any menu at the time of password entry.
First line of LCD will show “ Enter Password”.
Second line of LCD show Enter Password and it’s value.
Set require password value using INC, DEC and SHIFT key.
On pressing SAVE key the set value will be saved.
List of password entry parameter is given below.
No. Message Description Range Level
1 Entr Paswd Enter Password 0-9999 User
Page 18 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
24 ProBand Z2 C Proportional Band of Zone 2 0-100 C Supervisor
25 ProBand Z3 C Proportional Band of Zone 3 0-100 C Supervisor
26 IntGain Z1 S Integral Gain of Zone 1 0-1000 Sec Supervisor
27 IntGain Z2 S Integral Gain of Zone 2 0-1000 Sec Supervisor
28 IntGain Z3 S Integral Gain of Zone 3 0-1000 Sec Supervisor
29 CyTime Z1 S Cycle Time of Zone 1 0-100 Sec Supervisor
30 CyTime Z2 S Cycle Time of Zone 2 0-100 Sec Supervisor
31 CyTime Z3 S Cycle Time of Zone 3 0-100 Sec Supervisor
32 CyTime DR S Cycle Time of Die Ring 0-100 Sec Supervisor
33 CyTime HW S Cycle Time of Hot Wire 0-100 Sec Supervisor
Set Timers
Press set TIMER key.
First line of LCD will show “Set Timers'.
Second, third and forth lines of LCD show timer’s name and it’s set value.
Select require timer using UP/ DOWN key.
Set require timer using INC, DEC and SHIFT key.
On pressing SAVE key the set value will be saved.
List of timer parameter is given below.
No. Message Description Range Level
0 Blow time Blow time 0-100.00 sec
Exhaust Tm Exhaust Time 0-100.00 sec
Cycle Dely Cycle Delay 0-10 Sec
Paris Ontm Parison Time 0-10 Sec
Cutter Dly Cutter Delay 0-10 Sec
Cutr Impls Cutter Impulse 0-10 Sec
CarIn Fast Carriage In fast time 00-10 Sec
Car Out Fas Carriage Out fast time 00-10 Sec
Car Out End Carriage out end time 00-10 Sec
MCls Fast Mold Close Time 00-10 Sec
Mopn Fast Mold Open Time 00-10 Sec
MCls Dely Mold Close Delay Time 00-10 Sec
Tonnage Tim Tonnage time 00-10 Sec
Blopin Dly Blow Pin In Delay 00-10 Sec
Blopin Fas Blow Pin In Fast Time 00-10 Sec
Blopin Int Blow Pin In Intermediate Time 00-10 Sec
Blopin Slo Blow Pin In Slow Time 00-10 Sec
BPOut DI Blow Pin Out Delay Time 000-100 Sec
Blow delay Blow Delay 000-100 Sec
Eject Time Ejector Time 000-100 Sec
BPOut Rel Blow Pin Out Release Time 00-10 Sec
Deflash In Deflash In Time 00-10 Sec
DefOut Dly Deflash OutDly 00-10 Sec
Deflash Mov Deflash move time 00-10 Sec
Cy Ovr Tim Cycle Over Time ( Limit for Total Cycle Time) 00-10 Sec
Page 19 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
Set Miscellaneous
Press set MISC key.
First line of LCD will show “ Set Miscellaneous'.
Second, third and forth lines of LCD show function’s name and it’s value/status.
Select require function using UP/ DOWN key.
Set require value/ status using INC, DEC and SHIFT key.
On pressing SAVE key the set value will be saved.
List of miscellaneous parameter is given below.
Page 20 of 23
STREAMLINE CONTROLS PVT.LTD.
BLOkon 03 Manual
(N) INTERLOCKS
It is a one type of alarm system which activate when cycle or any other function does not operate
properly because of those abnormal condition it indicate INTERLOCK
Type Of Mode
Interlocks Messages
Sr.No. Operation Description Of Messages Fully
On Screen Hand
Auto
IL.Lt MOpen End Left Mold fully open end y y
1 Left Mold Open IL.Lt Mold Not Open Left Mold is not fully open y
IL.Lt Mld Opn/Cls On Left Mold open and close input on y y
IL.Lt Mclose End Left Mold fully Close end y y
2 Left Mold Close IL.Lt Blow Pn no Out Left Blow pin is not out y y
IL.Lt Mld Opn/Cls On Left Mold open and close input on y y
IL.Lt Cariage In End Left Carriage in end y y
IL Lt Blo Pn no Out Left Blow pin is not out y y
3 Left Carriage In
IL.Rt Station no Out Right station is not out y y
IL.Lt Carr In/Out On Left carriage in and out input is on y y
IL.Lt Carige Out End Left Carriage out end y y
IL.Lt Cariage no Out Left Carriage is not out y y
4 Left Carriage Out
IL Lt Blo Pn no Out Left Blow pin is not out y y
IL.Lt Carr In/Out On Left carriage in and out input is on y y
5 Left Blow Pin In IL Lt Cariage no Out Left Carriage is not out y y
6 Left Blow Pin Out IL.Lt Blo Pn Out End Left Blow pin out end y y
7 Emergency IL.Emergency Press Press Emergency Push Button y y
8 Hydro Motor IL.Hyd Motor Not On Hydro motor is not on y y
9 Hydro Motor Overload IL.Hyd Motr Ovr load Hydro motor is overload y y
10 Left Safety Door IL.Lt Safty door Opn Left safety door open y y
11 Right Safety Door IL.Rt Safty door Opn Right safety door open y y
Actual cycle time is exceed from set
12 Cycle Time Over IL.Cycle Time Exceed y
cycle time
13 Batch Count IL.Batch Count Over Set batch count is over y
IL.Extruder Up End Extruder up end y y
14 Extruder IL.Extruder Dn End Extruder down end y y
IL.Extrudr Motr Trip Extruder motor is trip y y
IL.Low Temperature Temperature is Low y y
15 Heating IL.High Temperature Temperature is High y y
IL.Oil Temp High Oil Temperature is high y y