Ic485ai Um W 2020-07-22
Ic485ai Um W 2020-07-22
RoHS
This product is RoHS compliant.
IC485AI User Manual
Online Registration
You can register your product at our online support center:
International http://support.aten.com
Online Support
International
North America
-3-
Telephone Support
For telephone support, call this number:
International 886-2-8692-6959
China 86-400-810-0-810
Japan 81-3-5615-5811
Korea 82-2-467-6789
North America 1-888-999-ATEN ext 4988
1-949-428-1111
-4-
Package Contents
The RS232 / RS485 Interface Converter package contains the
following items:
Check to make sure that all the components are present and that
nothing got damaged in shipping. If you encounter a problem,
contact your dealer.
Read this manual thoroughly and follow the installation and
operation procedures carefully to prevent any damage to the unit,
and/or any of the devices connected to it.
ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights
reserved. All other trademarks are the property of their respective owners.
-5-
Overview
Features
-6-
Cable distance of up to 1200 m (4000 ft.)
Compact size
Components
Top view:
1 6
2
4 5
1. Status LEDs
RTS: Lights to indicate that RTS has been pulled high.
TxD: Flashes when data transmission occurs.
2. RS-422 / RS-485 Terminal Block
3. Grounding Tab
4. DCE /DTE Selection Switch
If the IC-485AI is going to be plugged into a DTE device, the
switch must be set to DCE, and vice versa.
5. Power Jack
The cable from the Power Adapter plugs in here.
6. RS-232 DB-25 Female Connector
-7-
Bottom View:
1. DIP Switch
This eight segment DIP Switch, located on the unit’s bottom
panel, is used to configure the switch’s operating parameters.
-8-
DIP Switch Configuration
The IC-485AI’s settings for Baud Rate, Data Format, and RS-422
/ RS-485 Mode are configured by setting the eight segment DIP
Switch located on its bottom panel
Note: When you change any of the DIP Switch settings, you
must reset the device by powering it off, then powering
it on again.
Note: 1. The Baud Rate must be the same for all units on the
installation.
2. The default is 9600 bps.
SW 4: Reserved
-9-
SW 5-6: Data Format
These two switch segments configure the bit settings for Start,
Data, Parity, and Stop.
- 10 -
Operating Modes
Point-to-Point
A Point-to-Point configuration is one in which two devices,
located at two different places are linked for communication by a
pair of IC-485AI units. There are two configurations: Point-to-
Point Full Duplex, and Point-to-Point Half Duplex.
DB-25 DB-25
Connect T+ R+ Connect
to PC#1's T- R- to PC#2's
COM port R- T- COM port
R+ T+
- 11 -
2. Point-to-Point 2 Wire Half Duplex
DB-25 DB-25
Connect T+ R+ Connect
to PC#1's T- R- to PC#2's
COM port R- T- COM port
R+ T+
Multidrop
A Multidrop configuration is one in which more than two devices
are linked for communication using several IC-485AI units. One
of the devices that one of the IC-485AIs connects to is designated
as the Primary device. All the remaining devices that the rest of
the IC-485AIs connect to are designated as Secondary devices.
Up to 31 Secondary devices can be connected. There are two
configurations: Multidrop Full Duplex and Multidrop Half Duplex.
- 12 -
1. Multidrop Full Duplex
- 13 -
2. Multidrop Half Duplex
Multidrop Half Duplex uses reverse two wire cabling, to link all
the connected IC-485AI units:
Primary Secondary 1
T+ R+
PC1 T- R- PC2
COM1/ R- T- COM1/
COM2 R+ T+ COM2
Secondary 2
R+
PC3
R-
COM1/
T-
COM2
T+
Secondary 3
R+
R- PC4
T- COM1/
T+ COM2
.
.
Secondary 31
For all of the units set SW7 and SW8 according to the
table on p.9 to configure each unit’s RS-485 operating
mode (see p.10 for RS-485 operation details).
- 14 -
Simplex
A Simplex configuration is one in which more than two devices
are linked for communication using several IC-485AI units in a
manner similar to Multidrop. The difference is that in a Simplex
configuration, the Primary device can only talk, and the
Secondary devices can only listen.
Simplex uses reverse two wire cabling to link all the
connected IC-485AI units, as shown in the figure below:
Primary Secondary 1
T+ R+
PC1 PC2
T- R-
COM1/ COM1/
R- T-
COM2 COM2
R+ T+
Secondary 2
R+
PC3
R-
COM1/
T-
COM2
T+
Secondary 3
R+
PC4
R-
COM1/
T-
COM2
T+
:
:
Secondary 31
For all IC-485AI units, set the unit to DCE or DTE depending
on what type of device the IC-485AI will plug into (if it will plug
into a DCE device, configure it for DTE, and vice versa).
For all of the units (Primary and Secondary), set SW7 ON; set
SW8 ON.
- 15 -
Installation
1. Make sure that all the devices you will be connecting up are
powered off.
2. Set each IC-485AI’s configuration switches according to the
information provided in the Switch Configuration and
Operating Modes sections.
3. Plug the IC-485AI’s DB-25 female connector into the
computer’s RS-232C port.
4. Connect the IC-485AI units to each other.
a) Use two or four wire twisted pair cable in a reverse or
straight through configuration according to the
information provided in the Switch Configuration and
Operating Modes sections.
Note: 1. When tightening the terminal connector screws it is
recommended to use a Phillips PH1 Screwdriver.
2. Over-tightening the terminal connector screws may
result in damage to your IC-485AI and difficulty
loosening the screws.
b) See p.17 for the Terminal Block pin assignments.
5. Power on the computers. The units are now ready for
operation.
- 16 -
RS-422 / RS-485 Installation Diagrams
Primary Secondary 31
T+ R+
T- R-
R- T-
R+ T+
Secondary 1 Secondary 30
4,000'
RS-422 Full Duplex
Secondary 1 Secondary 30
4,000'
RS-485 Half Duplex
- 17 -
Appendix
Circuit Test
To test the IC-485AI’s internal circuits, connect a dumb terminal
to the unit and do the following:
1. Set the DCE / DTE switch to the opposite of the terminal.
2. Set all DIP Switch segments to ON.
3. Connect one wire from Tx+ (1) to Rx+ (4); connect a second
wire from Tx- (2) to Rx- (3).
4. Set the terminal to Full Duplex.
5. Set the baud rate of the communicaton application to 1200
bps.
6. Enter data.
If the circuit is operational, data appears on the screen
- 18 -
RS-485 Operation Mode Flow Charts
RTS Control Mode
Start
RTS=0
Send Receive
No No
Yes Yes
Receive
RTS=1
Data
Send
Complete
Data
No
Yes
Complete
Yes No
- 19 -
Auto Send Data Mode
Start
No
Idle Receive
CTS=0 Data
Data
Complete
to Send
No No
Yes Yes
Send
Data
Complete
Yes No
- 20 -
DCE / DTE Connection Description
- 21 -
Specifications
Function Specification
Power Consumption DC 9V; 900mW (max.)
Data Rate Up to 115.2 Kbps under 1200 m
(4000 ft.)
Connectors 1 x DB-25 female (RS-232);
1 x 4 Post Terminal Block (RS-422 /
RS-485);
1 x Grounding Tab
Function Slide Switch DCE / DTE Select
Switches
DIP Switch Segment 1-3: Baud Rate;
Segment 4: Reserved;
Segment 5&6: Data Format (bits);
Segment 7&8: RS-422 / RS-485
Select
Cable Distance Up to 1200 m (4000 ft.)
Operating Temperature 0 ~ 50ºC
Storage Temperature 20 ~ 60º C
Humidity 0 ~ 80% RH
Housing Plastic (ABS)
Weight 60 g
Dimensions (L x W x H) 54 x 74.5 x 18.5 mm
- 22 -
Troubleshooting
Symptom Action
Data Transmission Check that IC-485AI units are securely
Failure plugged into the computers’ serial ports.
Check that the cables are properly set up
and properly connected.
Check that SW1 and the DIP Switch are set
properly.
Insert terminal resistors according to the
information given on p. 13
Data Loss or Error Check that the Data Rate and Data Format
are the same for all devices.
Insert terminal resistors according to the
information given on p. 13
- 23 -
Limited Warranty
ATEN warrants its hardware in the country of purchase against
flaws in materials and workmanship for a Warranty Period of two
[2] years (warranty period may vary in certain regions/countries)
commencing on the date of original purchase. This warranty
period includes the LCD panel of ATEN LCD KVM switches.
Select products are warranted for an additional year (see A+
Warranty for further details). Cables and accessories are not
covered by the Standard Warranty.
- 24 -