PERSAN TERMOSIVA

HEAT and SOUND INSULATION PLASTER

Heat, Sound and Fire İnsulation Plaster

Description How To Use

Cement based, porous natural lightweight aggregates in the İn order to ensure ahomogeneous mixture, and the
mixture applied on the surface due to thermal-acoustic and
product performance packings are used at a time. Mixing
fire insulation that provides breathing space, polymers and
1000-1100 spees electric mixer concrete mixer machine or
chemical additives, multi-purpose insulation material in the
form of plaster. screet is preapared.

Certified to TS EN 998-1 TSE and EN 998-1 CE Back to plaster ratio of about 11-12 lt water inside and
Documents. mixed 4-5 minutes.
Areas of Usage During the appliccation starts to harden a few minutes of
It is used in place of rough cast on the surfaces such as the delay in product consistency are ready to use.
brick-gas concrete and concrete-pumice blocks in the
internal and external surfaces of buildings.
The prepared mortar, plaster strips between the steel
trowel or pump ıs applied in a single layer and leveled.
Features of Product Concrete forms, the material is removed after the
completion of pre-shrinkage and gaps are filled with
*It provides thermal, sound and fire insulation through one
product. plaster.
*It contributes to the budget in heating-cooling
Mixture Ratio
expenditures.
approximately 11-12 liters of water for 15 kg powder
*It does not put extra burden on the building since it is very
light. Application
*It does not require extra labor since it is applied as single
layer. The homogeneous mixture is applied as a single layer
*It does not let the formation of thermal bridges since it among the bars using a steel trowel or plaster pump; and
does not form interlayers. then is coated. When the pre-draining is over, the plaster
*It does not include harmful chemicals (carcinogen strips are removed and filled with PERSAN TERMOSIVA. If
materials) for the human and environmental health since it the product starts to set due to delays, it should be mixed
is an inorganic based material. for a few minutes.
*It forms fire barriers.
*It breaths. Points to take into consideration
*It increases the value of the buildings.
*It provides sound proof thanks to its cellular structure. * For PERSAN TERMOSIVA application, if the ambient
temperature is below +5°C or above +30°C, the suitable
conditions should be met. Extremely hot, rainy or windy
Application Procedure weather is not suitable for application.
Surface Preparation * The mixture starting to dry should not be mixed with water
and new material.
The application surface is cleaned from dust, oil, paint and * The material should not be applied thicker than 3 cm. If
stains. The loose parts are removed mechanically until necessary, the second layer is applied using a plaster
getting the solid ground. The absorbent and slippery mesh.
surfaces should be primed with eile TU-05. The strips that * The applications to be made on PERSAN TERMOSIVA
would determine the thickness of applied PERSAN should start at least 3 days later. The PERSAN
TERMOSIVA are fixed on the walls with the proper intervals TERMOSIVA surface must be watered once in 24 hours
to form plaster strips. interval or should be coated with eile PRIMER E 1 day after
the application.
* For the applications on exposed concrete surface, the
application floor must be primed with TU-05 or TU-06 to
increase the adherence of plaster mortar to the surface.
PERSAN TERMOSIVA
HEAT and SOUND INSULATION PLASTER

Technical Features

Structure of the material: It contains polymer and


fiber reinforced special cement as well as expanded
filling with special gradation.
Color : Grey/White
0 0
Application Temperature:+5 C/+30 C
Fire reaction : Class A 1
2
Bond resistance : ≥ 0.15 N/mm
Water Absorbency during Capillary Effects: W1
Compressive resistance : CS I
Thermal conductivity : Class T 1 ((0,052 W/mK) PERSAN YAPI ELEMANLARI MAD. SAN. TİC. A.Ş.
2
Water Vapor Permeability: ≤ 15 kg/m .s.Pa ORGANİZE SANAYİ BÖLGESİ 18 CADDE NO:1 ERZİNCAN
3
Hollow Dry Bulk Density: 400 ± 50 kg/m
2
Consumption : 3,5-4 Kg /m powder for 1 15
cm
Application Type : Steel Trowel-Plastering TS EN 998-1
Machine
Test Drying : 28 days (23 ®C )
Ready within : 2-3 days (23 ®C )
Water Absorbency during Capillary Effects: W1
Pot life : 120 minutes (23 ®C ) 2
Bond resistance: ≥ 0,15 N/mm
2
The typical values above are valid for the performances of the applications Water Vapor Permeability: ≤ 15 kg/m .s.Pa
28 days after their finish at +23°C for 50% relative humidity. The values Compressive resistance: CSI
might change due to the differences in the worksite environment.
Thermal conductivity factor: T1 sınıfı
Cleaning of ToolsThe tools and equipment used during the Fire reaction class: Class A 1
application should be cleaned with water. PERSAN
TERMOSIVA can be removed only mechanically after it
hardens.

Storage: Best stored in cool and dry place in their


unopened package with a maximum 11-fold stacking.

Shelf Life: 12 months following the production date under


the specified storage conditions and in unopened package

Packaging

Kraft sack of 15 kg

Safety Recommendations: Please wear the coveralls, protective gloves, glasses and mask suitable for occupational health and safety. Make sure that it does not contact the skin
and the eyes; in case it does, wash with plenty of water. In case swallowed, contact the closest health care institution immediately. Keep out of the reach of children. Keep food
and drinks away from the application areas.
Responsibility: In case the recommendations and application conditions specified above are not conformed, the applications (misuse) do not fall under the responsibility of
PERSAN A.Ş.The user is responsible for whether the product is used in accordance with its purpose, as well as the validity of application conditions and forms. PERSAN
A.Ş.does not accept any indemnity claim concerning the results, work accidents, direct or indirect damages or losses due to the misapplication of the products. PERSANA.Ş.
does not accept any indemnity claim concerning the results, work accidents, direct or indirect damages or losses due to the misapplication of the products.

Note: PERSAN reserves the right to improve/revise the product and this technical document over time. This Technical Data Sheet supersedes the former Technical Data Sheet
released for this product. The user must make sure that the available technical document is the latest updated version. If necessary, our company must be contacted to inquire the
updating status of the document. 2015

You might also like