Class Notes Uncertainty
Class Notes Uncertainty
1.1 Definitions
• Error analysis is the evaluation of uncertainty in measurements
• Error means uncertainty, not mistake, no negative connotation.
• Experimentation => measurements => comparison to a standard
e.g., length, time, weight, volume, chemical composition etc.
Example 1.
Measurement of length.
Questions:
o Why would repeated measurements give different numbers (what is the cause)
o What is the “true” length. (What actually do we mean by the length of the object;
there is no such thing, only a range of lengths).
o How do I report the length?
o How can I minimize the “error” or uncertainty in the measurement?
Example 2.
Measurement of particle number concentration with a CNC or CPC.
In some cases there is no way to compare the measurement to a correct value, (i.e.,
measurements of particle chemical composition). Normally, compare your measurement
to a more accurate standard. If you have no accurate standard, you may have a very
precise measurement but it could be far off from the correct answer. Need a “gold
standard” to test accuracy of measurement.
No "gold" standard
y
x
want as small random
error as possible, can't say
much about the bottom situation
Note, use all significant figures in the calculations, round off answer to
appropriate sig. figs.
Method 1: Exact Solution; it can be shown that the final error due to the combined
independent and random errors of individual measurements is (with negligible
approximation, 1st order Taylor series expanded about 0, -see Taylor Chapt 3 for detailed
derivations):
If the errors are independent, then can expect some cancellation between errors and the
total error will be less. Thus, better to use quadrature sum in above equation.
ΔCN = 5.95 + 11.68 + 0.59 [1/cm3] = 18.22 1/cm3 and the concentration is 590±18
Using quadrature sum: ΔCN = sqrt[5.952 + 11.682 + 0.592] = 13.12 (less than above).
7.5 5
7 ± 0.5
4
6.5 3.5
3
4
2
3±1
2 0.5
Repeated experiments: If you repeat an experiment you can use the (random) variation in
the measurements to estimate uncertainties due to random errors.
The error of the mean, (or standard error), is the uncertainty associated with the mean.
For similar expts. the uncertainty of each measurement is similar (~stdev), thus to reduce
uncertainty of mean, repeat the experiment (however, standard error is weak function of
N)
Mean ± standard error multiple measurements
X ± stdev one measurement
Confidence intervals:
1-σ = 68.3% confidence interval: Eg: x ± Δx, where Δx = σ = stdev: this means
that you are 68% confident that x is within x-Δx and x+Δx, if random errors are normally
distributed (or there is a 68% probability the event will be within ±1 σ either side of the
measurement (area under normal curve ±1 stdev from mean is 68%).
2-σ = 95.4% confidence intervals:
3-σ = 99.7% confidence intervals:
Assumes
• no uncertainty in x
• y uncertainties are all the
intercept A
same magnitude (if no
x weightings are used)
Measurement 2 • each y-measurement is
y
governed by normal dist.
and with same σy.
Measurement 1
The calibration curve has three distinct regions. (See figure 1). The segment Below the
Limit of Detection is where the factor level is not great enough or intense enough to
produce a signal greater than the background noise of the instrument. There is a high
noise to signal ratio. The Linear Region is the region where the response is
proportional to the factor level. As factor level increases, response increases. The linear
region extends to the Limit of Linearity, or the maximum factor level that will produce a
linear response. Any measurements of factor levels greater than the limit of linearity will
fall in the region Beyond the Limit of Detection, or where the detection device becomes
overloaded with incoming data.
The integrity of a calibration curve depends on how much of the entire linear range is
defined. In figure 2, three points denote a linear portion of the calibration curve, but there
is great uncertainty. Are these points merely coincidence or are they in the linear region?
In order to accurately describe such a curve, a series of know standards must be
constructed to add detail to the wide interval between points (figure 3)
Figure 2: Calibration Curve
20
18
16
14
12
Response
10
0
0 4 8 12 16 20 24
Factor Level
Figure 3: Calibration Curve
20
18
16
14
12
Response
10
0
0 4 8 12 16 20 24
Factor Level
Once a reliable calibration curve has been determined, factor levels for unknown samples
can be determined. The general formula for the linear portion of a calibration curve is
response = (slope × FL )+ b
Of course, for the calibration curve to be effective the factor must be detected and a
response provided. If the response of an unknown falls outside the established linear
range of the calibration curve, then additional work is required. If the response falls
below the Limit of Detection, then one must concentrate the sample. If the response lies
above the Limit of Linearity, then one must dilute the sample.
NOTE: All measurements (data points) and calibration curves have statistical limitations.
The following pages contain information and mathematical equations that describe some
of the basic statistics required for quantitative work for this course. Other possible
references include: Quantitative Chemical Analysis, Chemometrics, or Instrumental
Analysis textbook for a complete inventory of statistics for chemistry. Many statistics
texts will also be helpful.