ORD02 Wellhead Diagram History
ORD02 Wellhead Diagram History
Make FMC
Upper Type Model 120 Gate Valve, FE
Master Size 4.1/16"
Valve Rating 5,000 psi WP
Trim API AA / FMC /R
Make FMC
S A N D A B O V E 'A '
S E C T IO N Lower Type Model 120 Gate Valve, FE
Master Size 4.1/16"
Valve Rating 5,000 psi WP
Trim API AA / FMC /R
Make / Type FMC Thru-bore Adaptor Make / Type FMC
Upper 'C' Size / Rating 13-5/8" x 13.5/8" / 5,000 psi WP Assembly Size / Rating 13.5/8" x 4.1/16" / 5,000 psi WP
Section Outlet 1 Valve Gate Valve, 2 1/16" 5,000 psi WP FE Fittings SSSV Port / Test Port
Outlet 2 Fittings A2 Adapter x 2" API LP w/ bull plug&1/2" Tubing Make / Type FMC Split type
Make / Type - Hanger Size / Rating 13.5/8"/9" x 4.1/2"NV/5000psiWP
Middle 'B' Size / Rating - Casing Make / Type FMC
Section Outlet 3 Valve - Hanger Size / Rating 13 5/8" x 9 5/8" / 5,000 psi WP
Outlet 4 Fittings - Remarks After Audit 15/1/2. Oriented to Rio Negro.
Make / Type FMC Thru-bore - No orientation modification required.
Lower 'A' Size / Rating 13.5/8" 5K x 15.1/4" ACME & 20" lnd ring - Actuated SSV to be installed as 2nd lateral valve
Section Outlet 5 Valve Gate Valve, 2 1/16" 5,000 psi WP FE - Otherwise per drilling contracter requirements
Outlet 6 Fittings A2 Adapter x 2" API LP w/ bull plug&1/2" - Gaslift connection not required
816615373.xls
SUBSURFACE DEPARTMENT
Ourhoud SINGLE WELLHEAD AS INSTALLED
WELL : ORD-2 BLOCK / SAT : 406A / SAT 4 DATE COMPLETED : Oct 20 1995
FIELD : Ourhoud COUNTRY : Algeria
Make FMC
Upper Type Model 120 Gate Valve, FE
Master Size 4.1/16"
Valve Rating 5,000 psi WP
Trim API AA / FMC /R
Make FMC
Lower Type Model 120 Gate Valve, FE
Master Size 4.1/16"
Valve Rating 5,000 psi WP
Trim API AA / FMC /R
Make / Type FMC Thru-bore Adaptor Make / Type FMC
Upper 'C' Size / Rating 13-5/8" x 13.5/8" / 5,000 psi WP Assembly Size / Rating 13.5/8" x 4.1/16" / 5,000 psi WP
Section Outlet 1 Valve Gate Valve, 2 1/16" 5,000 psi WP FE Fittings SSSV Port / Test Port
Outlet 2 Fittings A2 Adapter x 2" API LP w/ bull plug&1/2" Tubing Make / Type FMC Split type
Make / Type - Hanger Size / Rating 13.5/8"/9" x 4.1/2"NV/5000psiWP
Middle 'B' Size / Rating - Casing Make / Type FMC
Section Outlet 3 Valve - Hanger Size / Rating 13 5/8" x 9 5/8" / 5,000 psi WP
Outlet 4 Fittings - Remarks After Audit 15/1/2. Oriented to Rio Negro.
Make / Type FMC Thru-bore - No orientation modification required.
Lower 'A' Size / Rating 13.5/8" 5K x 15.1/4" ACME & 20" lnd ring - Actuated SSV to be installed as 2nd lateral valve
Section Outlet 5 Valve Gate Valve, 2 1/16" 5,000 psi WP FE - Otherwise per drilling contracter requirements
Outlet 6 Fittings A2 Adapter x 2" API LP w/ bull plug&1/2" - Gaslift connection not required
816615373.xls
SUBSURFACE DEPARTMENT
Ourhoud SINGLE WELLHEAD AS INSTALLED
WELL : ORD-2 BLOCK / SAT : 406A / SAT 4 DATE COMPLETED : 02/07/2008
FIELD : Ourhoud COUNTRY : Algeria
816615373.xls