4.2.1 May Ngat SM6
4.2.1 May Ngat SM6
BMTBD-nxcuong
https://electrical-engineering-portal.com/substation-data-center
SM6 Switchgears
1
https://electrical-engineering-portal.com/substation-data-center
SM6 Switchgears
https://electrical-engineering-portal.com/substation-data-center
SM6 Switchgears
MV/LV dry type transformer without
enclosure installed in Data Center
2
SM6 Switchgears
standards
• recommendations:
IEC 298, 265, 129,
694, 420, 56;
primary distribution
secondary distribution
7
BMTBD-nxcuong
3
MV/LV transformer substations
Public distribution
Consumer substations
Primary distribution
Secondary distribution
8
BMTBD-nxcuong
Industrial
distribution
substations
9
BMTBD-nxcuong
4
Switch cubicles
2
1 1. switchgear
4 2. busbars
3. operating mechanism
3
4. low voltage
5. connection
10
BMTBD-nxcuong
5
1 1. switchgear
3 2. busbars
3. operating mechanism
4. connection and circuit breaker
5. low voltage
3
4
11
BMTBD-nxcuong
5
Switchgear (switch and disconnector) compartment
safety membrane
switch-diconnector
Earthing switch
12
BMTBD-nxcuong
Switchgear compartment
1 enclosure
2 cover
3 operating shaft
4 fixed contact
5 moving contact
6 seal
13
BMTBD-nxcuong
6
Switchgear compartment
3-position switch
Isolation
Making capacity of earthing switch
Optimized breaking technique
14
BMTBD-nxcuong
Busbar compartment
15
BMTBD-nxcuong
7
Connection and switchgear (circuit breaker) compartment
Single-handed connection
Field distributors
16
BMTBD-nxcuong
17
BMTBD-nxcuong
8
SF6 circuit breaker
special sensors
dedicated electronic relays
no auxiliary power supply
18
BMTBD-nxcuong
1 enclosure
2 bottom cover
3 operating shaft
4 main moving contact
5 moving arcing contact
6 fixed arcing contact
7 sealing system
8 compression chamber
9 moving piston
10 valves
11 insulating nozzle
19
BMTBD-nxcuong
9
breaking principle
20
BMTBD-nxcuong
21
BMTBD-nxcuong
10
Operating mechanism compartment
22
BMTBD-nxcuong
Positive break
Natural interlocking
23
BMTBD-nxcuong
11
For protection and control/monitoring systems
24
BMTBD-nxcuong
Easergy P3 relay
25
BMTBD-nxcuong
12
Protection and control monitoring functions
26
BMTBD-nxcuong
27
BMTBD-nxcuong
13
Connection to networks
29
BMTBD-nxcuong
Protection
Fuses-switch Fuses-switch
unit combination unit
PM 375 QM 375
30
BMTBD-nxcuong
14
Protection
Fuses-switch Fuses-switch
combination unit combination unit,
right or left outgoing line
31
BMTBD-nxcuong
Protection
32
BMTBD-nxcuong
15
Protection
Single-isolation circuit
Single-isolation
breaker unit right or
circuit breaker unit
left outgoing line
33
BMTBD-nxcuong
Protection
DM2 750
BMTBD-nxcuong
Disconnector: Double-function operating mechanism CS 34
16
Protection
35
BMTBD-nxcuong
MV metering
36
BMTBD-nxcuong
17
MV metering
37
BMTBD-nxcuong
38
BMTBD-nxcuong
18
Functions required by private networks
Incoming Incoming
cable-connection unit cable-connection unit
39
BMTBD-nxcuong
SM 375 TM 375
40
BMTBD-nxcuong
19
Functions required by private networks
41
BMTBD-nxcuong
Electrical characteristics
20
Electrical characteristics
Easy installation
44
BMTBD-nxcuong
21
Overall quality
Routine tests
Inspections
EDF/SEPIA
mechanical quality audit
operating times
seal Annual production
Dielectric line sampling
45
BMTBD-nxcuong
22