Edge Data Centers across 56 cities (2022 – 2027) Bhubaneshwar, Chandigarh, Coimbatore, Guwahati, Indore, Jaipur,
13 Edge Data Centers in Phase I (2022 – 2024) Kochi, Lucknow, Mangalore, Nagpur, Surat, Varanasi, Vishakhapatnam
ABOUT CHANDIVALI
DC PARK
YOTTA CHANDIVALI DATA CENTRE - LOCATION
LAND
OWNERSHIP Self-owned DESIGN PUE < 1.5 LAND AREA 4 Acres
STATUS
POWER NO. OF 2
FIBER FEASIBILITY Feasible Secured
PERMITTING / BUILDINGS
STATUS
FEASIBILITY STATUS
RACKS 12,000
NO. OF FIBER ESTIMATED End
4
PATHS GO-LIVE DATE 2025
TVRA Moderate
CONTRACTING Rating
FIBER OPERATORS COLO+
8+ OPTIONS IN 8
IN CAMPUS BTS
THE CAMPUS
DEDICATED ADMIN BLDG
SERVICES TYPES COLO+BTS
IN THE CAMPUS +Cloud
DEDICATED DG BLDG
YOTTA CHANDIVALI DC PARK – BUILDINGS M1 & M2
3. Racks 6,000
4. IT Power 33.5 MW
5. Total Power 50 MW
• 1 km from
Saki RSS
• 2.9 km from
Sahar RSS
PROPOSED HT POWER DISTRIBUTION
POWER BACK UP
MMR
FIBER DUCT
FIBER DUCT
MMR
21
PROPOSED REDUNDANT FIBRE CONNECTIVITY AT CHANDIVALI
4 paths from DC to
Main Highways
Redundant Fiber
Riser Conduits
Redundant
MM Rooms
Yotta Fiber to
other DCs & LSs* INTERNET EXCHANGES
Connectivity to
Hyperscalers
STANDOUT
FEATURES
OPERATIONAL FEATURES
2. Yotta Data Center Park Entrance 7. Explosive & Narcotics Detection 12. Server Key Access Management
4. Barbed fenced walls with more than 14. Biometric authentication to enter the
9. Access controlled visitor pass is issued from
500 Surveillance Cameras which are reception server hall
manually and AI Monitored
5. Dedicated vehicle holding with 10. Turnstile barriers to exit the lobby
boom barrier restricts access 15. Cage and Rack Authentication as
required
PROPOSED 15-LAYER PHYSICAL SECURITY
PROPOSED MATERIAL HANDLING AT YOTTA CHANDIVALI DC PARK
➢ Monitored and Managed 24x7 ➢ State of the art & feature rich BMS
Monitors round the clock
➢ Helpdesk for monitoring of auto alerts and
ticket management ➢ Monitors all parameters such
as Temperature, Relative Humidity,
➢ NOC - SOC Integration Power Consumption. Transformers,
➢ Automated intrusion detection Diesel Generator Sets, Fuel Storage,
High Tension Panels, Cooling
➢ Technical domain expertise and experience systems monitoring available.
PROPOSED ADMIN BUILDING FACILITIES
Our Project Management methodology is a comprehensive Project delivery approach which is consistently followed to manage the
projects in an effective and efficient manner.
Each Project is handled by a dedicated Project Manager who acts as the Single Point of Contact (SPOC) for customer during the
implementation phase for any issues as well as for availing new services.
PROCUREMENT
PROJECT
PROJECT PROJECT & PROJECT
DESIGN PHASE COMPLETION &
INITIATION PLANNING MOBILIZATION DELIVERY
HANDOVER
PHASE
31
WHY YOTTA
Own Land
Power Distribution to cater to DC park Capacity Design
IV Tier 3 with 99.982% Uptime
Dedicated Building, Floor, SHs, Cage
4 Redundant Fiber Path
15 Layers of Security
Secure Key Management System
Explosives and Narcotics Detection
RFID based Asset Tracking and Configuration Management Database (CMDB) access to the customer
Real Time 24x7 access of the Facility BMS system and the CCTV monitoring system to the customer
33
YOTTA CERTIFICATIONS & RECOGNITIONS – Global and Site Specific
Best DC Operations
*In progress Team By
ISO/IEC 27017:2015
ISO/IEC 27018: 2019
PII 732157
ISO 9001:2015
FS 731404 Excellence In Datacenter
Asia Pacific Awards 2021 By
ITMS 732160
ISO/IEC 20000-1:2018
PCI DSS
AIS 732033
ISO/IEC 27001:2013
IS 730449