Product Specification

37446F

RP-3000
Remote Panel for
easYgen-3000 Series
Genset Controls

DESCRIPTION • Remote annunciation


and remote control of
The RP-3000 is a remote control and annunciation
panel for use with the back-panel mounted the easYgen-3000 Series
easYgen-3100/3400 or door-mounted generator controls
easYgen-3200/3500 genset controls.

It offers switchgear builders an off-the-shelf HMI op- • Password-protected re-


tion for any application where remote control is de-
sired, such as hospitals, marine switchboards, drill mote configuration for
platforms, data centers, landfill and wastewater gas- all parameter settings
to-power applications or other outdoor switchgear
installations.
• Same look and feel as
The RP-3000 is an ideal solution for door-mounted
applications, providing control from the front panel
the easYgen-3200/3500
with greatly reduced wiring to the access door, while display
keeping high-voltage connections located safely on
the back panel.
• Color display
The RP-3000 allows remote control, remote visualiza-
tion (including a synch-scope), and password-
protected remote configuration of the easYgen-3000 • CAN communication to
Series generator controls, with access to its complete genset control
menu structure and all parameter settings.

It has the same look and feel as the easYgen-3200 or • Multi-lingual Capability
easYgen-3500 genset control.

Each RP-3000 remote panel communicates with a • CE Marked


single easYgen-3000 Series genset control via CAN
communication. A single relay output is provided to
signal “Ready for Operation”. • UL / cUL Listing

• LR & ABS Marine


Features
• DNV1
• Each RP-3000 connects directly to one
easYgen-3100/3400 or easYgen-3200/3500
via CAN Bus communication port
• Output relay signal indicates
“Ready for Operation”
• Multi-lingual display capability

1 For details see last page


SPECIFICATIONS
Power supply ........................................................ 12/24 Vdc (8 to 40 Vdc) Housing Front panel flush mounting .................. Plastic housing
Intrinsic consumption ..................................................................max. 12 W Dimensions WxHxD .......................................... 282 × 217 × 67 mm
Ambient temperature (operation) ....................... -20 to 70 °C / -4 to 158 °F Front cutout WxH .................................. 249 [+1.1] × 183 [+1.0] mm
Ambient temperature (storage) ........................ -30 to 80 °C / -22 to 176 °F Connection ....................................................... screw/plug terminals 2.5 mm²
Ambient humidity...................................................... 95 %, non-condensing Front.................................................................................... insulating surface
Relay output .......................................................................... potential free Sealing Front .................................. IP66 (with screw fastening)
Contact material ............................................................................... AgCdO Front .................................. IP54 (with clamp fastening)
Load (GP)......................................................................2.00 Aac@250 Vac Back ...................................................................... IP10
................... 2.00 Adc@24 Vdc / 0.36 Adc@125 Vdc / 0.18 Adc@250 Vdc Weight .................................................................................... approx. 1,300 g
Pilot duty (PD) .............................................................................................. Disturbance test (CE) ............ tested according to applicable EN guidelines
................... 1.00 Adc@24 Vdc / 0.22 Adc@125 Vdc / 0.10 Adc@250 Vdc Listings .............................................................................................UL / cUL
Marine ................................LR (Type Approval), ABS (Type Approval), DNV

DIMENSIONS

Plastic housing for front panel mounting


TERMINAL DIAGRAM
FEATURES OVERVIEW
International
Woodward
PO Box 1519 Model RP-3000
Fort Collins CO, USA
80522-1519
1000 East Drake Road HMI
Fort Collins CO 80525 Soft keys (advanced LCD display) DynamicsLCDTM Yes
Ph: +1 (970) 498-3634 Color display 
Fax: +1 (970) 498-3058 I/Os
email: CAN bus communication interfaces FlexCANTM 1
[email protected] RS-232 1
Relay output ( Ready for operation ) 1
Europe
Woodward GmbH Listings/Approvals
Handwerkstrasse 29 UL / cUL Listing 
70565 Stuttgart, Germany LR Marine Type Approval 
Ph: +49 (0) 711 789 54-510 ABS Marine Type Approval 
Fax: +49 (0) 711 789 54-101 DNV  (P/N 8446-1046 only)
email: CE Marked 
[email protected] Part Numbers
Front panel mounting with display (easYgen-3100/3200/3400/3500) P/N 8446- 1048
Distributors & Service
Front panel mounting with display (easYgen-3400/3500 Marine) P/N 8446- 1046
Woodward has an international
Spare connector kit P/N 8923- 1314
network of distributors and
service facilities. For your
nearest representative, call the
Fort Collins plant or see the RP-3000 OVERVIEW
Worldwide Directory on our
website. The following easYgen-3000 genset controls are supported by the RP-3000 remote panel.

RP-3000 P/N 8446-1048 P/N 8446-1046


www.woodward.com
easYgen-3100/3200
Package P11 / Package P22  -
easYgen-3400/3500
Package P1  -
easYgen-3400/3500 Marine
- 
For more information contact:

Package P1

1 easYgen-3100/3200 Package P1 software version 1.15xx or higher.


1 easYgen-3100/3200 Package P2 software version 1.13xx or higher.

Subject to technical modifications.

This document is distributed for


informational purposes only. It is not
to be construed as creating or
becoming part of any Woodward
Governor Company contractual or
warranty obligation unless expressly
stated in a written sales contract.

We appreciate your comments


about the content of our publica-
tions. Please send comments
including the document number
below to
[email protected]

© Woodward

All Rights Reserved

37446F - 2012/07/Stuttgart

You might also like