controller PFR 6 / PFR 12

POWER FACTOR REGULATOR Controller PFR 6/ PFR 12


The Controller PFR 6/ PFR 12 PF regulators measure cosϕ in a supply system and control the connection and disconnection of capacitors to
obtain a target programmed value.
Display
Standard mode: Displays cosϕ
cosϕ Indication / setting
C/K setting. See paragraph 6
Program setting. See 4.2
Delay time setting for switching on/off operations
Nr of steps setting
Setting CT phase and polarity connection
- Cursor keys (when in setting mode)
- Manual ON / OFF (push during more than 1s when in RUN mode)
- Push both to see the Nr of connected steps
SETUP KEY: Push during more than 1s to enter SETUP mode
Lagging current indication (Inductive load)
11 Leading current indication (Capacitive load)

This manual is an easy guide for the use and operation of the Any manipulation or use of the equipment out of the conditions
Controller PFR 6/PFR 12. For more information, the complete specified by the manufacturer may put in risk the user safety. Before
manual can be downloaded from the web site of ZEZ SILKO: any maintenance operation the equipment must be disconnected from power
www.zez-silko.cz supply. In case of miss operation or protection fault the equipment must be
disconnected from supply and remain out of service ensuring against any
accidental reconnection.

1.- Regulator Connection

For proper operation it’s necessary to install a current transformer, CT A B COM 1 2 3 4 5 6 C D


POWER
(normally In / 5 A), which primary must be sized according to the SUPPLY
maximum expected load current in the installation.
The regulator supply (C-D terminals) must be taken between two S1 S2 L2 L3
phases and the CT should be located in the third phase. See technical
characteristics for cable sizes and required protections.
Must use an switch or automatic switch for supply the regulator RELAY C1..C6

RELAY C7..C12
The current transformer , CT, S1
CT
must be located so that it S2
measures the whole load current
plus the correction capacitors Sólo en
Computermax 12

CAPACITORS COM 7 8 9 10 11 12

Control system FCP (Minimum number of operations)


2.- TECHNICAL CHARACTERISTICS
3.- Four Quadrants Operation
Supply and V measurement input 400 VAC - standard, 110, 230, 480 VAC-on request, +15%-10%
terminals (C-D) 45-65 Hz, Connect preferably to phases L2-L3 The Controller PFR 6/PFR 12 regulators operate in 4 quadrants (suitable
Supply cables size and protection Cross section 1,5mm2 ; 0,5 to 2A Fuses gl type
for imported or exported active power). For exported power, a negative
Current transformer (CT) , In /5 , Place preferably in phase L1 symbol is displayed in the cosϕ indication. Check phase connection and
Current measurement circuit
Minimum cabling cross section 2,5mm2
setup if there is no exported energy and the indication is not correct (see 4.3,
Current measurement margin 0,1 to 5 A (maximum overload +20%) SET-UP - phase)
Accuracy of measurements Voltage and current :1%; cosϕ : 2% ± 1 dígit
110V: 7 VA (no load) ; 8 VA(6 relays); 9,8 VA(12 relays)
230V: 7 VA (no load) ; 8 VA(6 relays); 9,6 VA(12 relays) Lagging / Inductive 90º Lagging / Inductive
Power consumptions
400V: 6 VA (no load) ; 7,5 VA(6 relays); 9,5 VA(12 relays) KW - KW +
480V: 7,8 VA (no load) ; 8,6 VA(6 relays); 10 VA(12 relays) kVAr + kVAr +
Display 1 line x 3 digits x 7segments + 20 icons Cosϕ - Cosϕ +
Output Relay Contacts Max. 250 VAC, 10 A, AC1
Output Relay Cabling and Cabling cross section 1,5mm2 , Protection by means of a 6A 180º 0º
Protection circuit breaker (C curve) or by a 6A fuse (gl type)
KW - KW +
Alarm Output Relay Last relay automatically set as alarm output , if not in use
kVAr - kVAr -
EN 61010, EN 61000-3-2, EN 61000-3-3, EN 50081-2, EN 50082-
Compliant to the following Cosϕ - Cosϕ +
1, EN 50082-2, EN 61000-4-2, EN 61000-4-4, EN 61000-4-8, EN
Standards
61000-4-5, EN 61000-4-11 , UL 94
Safety / Insulation Category III , Class II, According to EN 61010-1, Leading/Capacitive Leading/Capacitive
-90º
Temperature limits: -20ºC a +60ºC; Relative Humidity 95%
Environment limit conditions
(without condensation). Max. Altitude: 2000m

Protection degree
IP51 (panel mounted) Exported Power Imported Power
IP30 (regulator box) , According to EN-60529
controller PFR 6 / PFR 12

4.- SETUP AND MEASUREMENTS


To enter the SETUP mode, press the setup key (9), for more than 1s. If all the capacitors are disconnected, the access in immediate, otherwise a disconnection sequence
starts and then accesses to setup menu. In the SETUP mode, if no key is pressed for 3 minutes, the equipment exits such mode and returns to normal operation mode.

Key to access the SETUP mode:


- Long push to enter and exit SETUP mode. Also DELETE max values when 4.1.- RUN & Measuring mode
In normal operation mode (RUN mode) the regulator display may show different
in the measuring mode
parameters (V, I, cosϕ, etc.) The displayed parameter is pointed by the sign .
- Short push: to change from display mode to edit mode and vice versa.
If no key is pushed during more than 3 minutes, the regulator exits the SETUP By default the regulator displays the cosϕ, but pushing the keys the
mode without changing the setup. following parameters can be explored: Current (I), Current harmonics (THD), Mains
: Symbol showing which parameter is being displayed or edited. Voltage (V), Maximum current (I MAX) y Maximum voltage (V MAX). If both keys
are pushed simultaneously the regulator displays the Nr of connected steps.
- In the display mode: Cursors to select an option. points to the option
- In edit mode: Change a parameter value A long push of key when maximum values are displayed causes de deletion of
recorded max values.
Display SETUP Parameters Edit SETUP parameters Description
MENU OPTIONS
4.2.- Program selection
This setting depends on the kvar ratio between the different capacitor steps. For
instance if the bank is 10+20+20+20 kvar the program is 1:2:2:2, so the option 122
must be selected.
Display Program Display Program
111 1:1:1:1 248 1:2:4:8
122 1:2:2:2 112 1:1:2:2
124 1:2:4:4
Target cos ϕ (def=1) 4.3.- Selecting the CT connection phase
Reactive I of 1st step, Choose among the options in the table depending on CT connection and the
C/K adjustment phases where V is measured. In normal installations (no exported energy) choose
Range: 0.02 – 1.00 the option for which the displayed cosϕ is between 0.7 Ind and 0.98 Cap.
See paragraph 6 V-I phase shift at Measuring phases Phase where TC is
Display
cosϕ=1 for V connected
Program setting T1 30º L3-L2 L3
Depends on the kvar T2 270º L3-L2 L1
relationship between T3 150º L3-L2 L2
successive steps. T4 210º L3-L2 L3 (CT reversed)
See paragraph 4.2 T5 90º L3-L2 L1 (CT reversed)
T6 330º L3-L2 L2 (CT reversed)
Delay for successive
steps (4 -999 s) . 4.4.- Selecting the rated primary current of CT
Re-connection delay
is = 5 times T ON
If the LED is blinking indicates that we are in SETUP mode and
adjusting primary CT current. When in RUN mode or when Iprimary is displayed,
Selection of Nr of the LED indicates whether the displayed current has a scale factor x1 (LED OFF)
relays , PFR 6 or 12 or x10 (LED ON)
depending on type 5.- Error Codes
CT connection . See ERR CODE DISPLAY DESCRIPCIÓN ACTUACIÓN
paragraph 4.3. The Load current below measuring threshold or Forces all the
E.01 Alll zeros
CT not connected relays OFF
display shows T1, T2,
cos ϕ and E.02 Overcompensation. The regulador is asking to NO ACTION
T3, T4, T5 or T6. E.02
alternate blinking disconnect Cs and they are all disconnected
Accept the option cos ϕ and E.03 Sub-compensation. The regulator is asking for more NO ACTION
giving cosϕ between E.03
alternate blinking Cs and they are all connected
0.7 Ind and 0.98 Cap cos ϕ and E.04 Over current. The current is + 20%. Above primary NO ACTION
E.04
alternate blinking rated current
CT primary current cos ϕ and E.05 Overvoltage. Voltage is +15%. Above rated voltage NO ACTION
E.05
setting. See alternate blinking
paragraph 4.4

6.- C/K table depending on initial cosϕ , desired cosϕ and CT ratio
CT Ratio Lower step reactive power (kvar) at 400V C/K calculation:
CT 2.5 5,00 7.5 10,0 12,5 15,0 20,0 25,0 30,0 37,5 40,0 50,0 60,0 75,0 80,0
If It is the primary rated current of the CT and It
150/5 0,12 0,24 0,36 0,48 0,60 0,72 0,96 Ic the rated current of the lower capacitor step, =K
200/5 0,09 0,18 0,27 0,36 0,45 0,54 0,72 0,90 the C/K must be set according to the 5
250/5 0,07 0,14 0,22 0,29 0,36 0,43 0,58 0,72 0,87 calculations shown below:
300/5 0,06 0,12 0,18 0,24 0,30 0,36 0,48 0,60 0,72 0,90 0,96 Q
400/5 0,05 0,09 0,14 0,18 0,23 0,24 0,36 0,48 0,58 0,67 0,72 0,87
IC =
Example : CT current ratio = 500/5 3 .V
500/5 0,07 0,11 0,14 0,18 0,22 0,29 0,36 0,45 0,54 0,54 0,72 0,87 Lower step power: 60 kvar at 400V
600/5 0,06 0,09 0,12 0,15 0,18 0,24 0,30 0,36 0,45 0,48 0,60 0,72 0,90 0,96
800/5 0,07 0,09 0,11 0,14 0,18 0,23 0,27 0,33 0,36 0,45 0,54 0,68 0,72 500 60.000
K= = 100 ; I C = = 86 ,7 A
1000/5 0,05 0,07 0,09 0,11 0,14 0,18 0,22 0,27 0,29 0,36 0,43 0,54 0,57 5 1,73 × 400 Ic
C/ K =
1500/5 0,05 0,06 0,07 0,10 0,12 0,14 0,18 0,19 0,24 0,29 0,36 0,38 Ic 86 ,7 K
C/K = = = 0 ,867
2000/5 0,05 0,07 0,09 0,11 0,13 0,14 0,18 0,22 0,27 0,28 K 100
2500/5 0,06 0,07 0,09 0,10 0,12 0,14 0,17 0,22 0,23
3000/5 0,05 0,06 0,07 0,09 0,10 0,12 0,14 0,18 0,19
4000/5 0,05 0,06 0,07 0,09 0,11 0,14 0,14
For different voltages (V) of 400V, table result must be multiply for 400/V, or calculate C/K parameter using the expressions.

7.- Technical Service


ZEZ SILKO Tel: +420 465 673 111
For any inquiry about the regulator operation or in case of malfunction please
Pod černým lesem 683 Fax: +420 465 612 319
contact with technical service.
Žamberk e-mail: [email protected]
Czech Republic web: www.zez-silko.cz