LOGIC EPROM RESET

Put the elevator in normal from controller and Cabin.

Disconnect the cable INS from LOGIC Board (KL 13 green connector – middle white cable)

INS signal

Then press silmutaneously the push buttons on Logic board : right arrow – down arrow – Enter –
ESC. (for 3 sec)

Release the 4 push button silmutaneously.

Logic eprom ask you for the code : press 4 times ENTER.

You can see that the eprom makes initiallization.


After few sec the board writes INSPECTION , at that point connect the cable INS and put the lift in
ispection from controller.

Press enter to access parameter of programming and follow the below parameters :

Par am et er s of Indicator s
PARAMETERS PROGRAMMING Next departure Arrow s ( Y/N )
Call Registry Flashing ( Y/N )
Gener al Tim er s
Direction Arrow s Flashing ( Y/N )
Travel Timer High Speed ( 20 -60 )
Landing Calls Flashing ( Y/N )
Travel Timer Slow Speed ( 6 -45 )
Car Lights Timer ( 0-60 )
Travel Timer Releveling ( 0 -15 )
Timer Lift in Use ( 0-60 )
On Level Betw een Floors ( 0-10 )
Gong Activation Point ( 0-1 )
Auto Parking Timer ( 0 -10 )
Gong Pulse Duration (100-3000 )

Par am et er Level Funct ions


No of Floors ( 2-8 )
CHECK FAULT HISTORY
Parking Level Choise ( 2-8 )
Check Error History
Delete Fault History

Par am et er of Door Funct ions ADJUST TIME AND DATE


Type of Doors ( 0-1 ) Adjust Date
Door Signals Permanent ( Y/N ) Adjust Time
Parking With Open Doors ( Y/N )
Door Open Time on Level ( 3-45 ) SPECIAL PARAM ETERS
Door Close Time-Out Time ( 3-45 ) Parking Timer
Door Pos Open on Out of Order ( Y/N ) Relev.Start Delay
No Car Door Function ( Y/N ) Reset Positioning
Check Door Zone
Timer Between Calls
Par am et er Elevat or Motion Inspection Speed
Choise of Lift Type ( 0-5 ) Maintenance Speed
Motor Delay Stop Time ( 0-3000 ) PTC Check Motor Health
Valve Delay Stop Time ( 0-3000 ) PTC Check Oil Temperature
Υ/Δ Timer Start Time ( 0-5000 ) Tring Not Found Oil Temperature
Intermediate VVVF speed activation ( Y/N ) Dip Switch 1 Setting
END of Motion Delay Activation ( Y/N ) Debounce Time For Safety 10
END of Motion Delay Seting ( 0-5000 ) Debounce Time For Safety 8
Trig Not Found Tstop Dow n ( 0-1000 ) Debounce Time For Safety 8a
Car Landing Common ( Y/N ) Debounce Time For Safety 6
Single Automatic Push Button ( Y/N ) Debounce Time For Safety 1b
Manual Control With C3, C4 ( Y/N )

Par am et er of Fir e Fight ing


Def ine Fireman Type ( 0-3 )
Def ine Fireman Level ( 1-8 )

PASSWORD FOR SPECIAL PARAMETERS 4 TIMES UP ARROW.