DS DIESSEFLUID CONTROL

Product origin
Design & Manufacturing

GLASS level gauges ITALY

● WITH REFLEX GLASSES


● WITH TRANSPARENT GLASSES
● WELD-ON TYPE
● WITH GLASS TUBE
TO RECOMMEND THE MOST SUITABLE LEVEL GAUGE FOR A PARTICULAR PURPOSE,
PLEASE PROVIDE THE FOLLOWING DATA WHEN ASKING FOR ADVICE OR A QUOTATION.

► essential data

• ►CENTRE-TO-CENTRE DISTANCE (distance between process connections)


• MINIMUM VISIBLE LENGTH REQUIRED
• ► TYPE OF CONNECTIONS (flanged-threaded-weld-on) and related STANDARDS (UNI-ANSI-DIN…)
• POSITION OF PROCESS CONNECTIONS
• POSITION OF THE VALVE HANDLING
• ► REQUIRED MATERIAL (wetted and non-wetted parts)
• ► TYPE OF FLUID
• ► DESIGN AND MAXIMUM OPERATING PRESSURES
• ► DESIGN AND MAXIMUM OPERATING TEMPERATURES
• ANY ADDITIONAL ACCESSORIES

Glass level gauges give very accurate level readings, making them the
ideal product for calibrating other instruments as well.
They play a crucial role during system start-up.
READING TYPE
The required visible length depends on the type of
fluid and the shape of the tank.
The visible length with a single glass varies from 95
mm to 320 mm. If the required visible length
exceeds these measurements, additional glasses of
the same length are joined together and mounted
on a single bar.
To ensure continuous reading along a housing
consisting of numerous glasses, one or more
housings can be placed on the side at the points
where the reading is interrupted.

Single Multiple Multiple


housing housing housing with
continuous
reading
GLASS LEVEL GAUGES
Code

1 Basic Type

DS LG DIESSE Glass level gauge

2 Level Gauge Model

Pos. 1: Level Gauge type Pos. 2: No. of sections Pos. 3: Glass size / type

RTR Reflex - rotating execution with tubular cover


RTF Reflex - fixed distance execution with tubular cover
RBR Reflex - rotating execution with lateral covers
RBF Reflex - fixed distance execution with lateral covers
RCR Reflex - rotating execution with light cover
RDR Reflex - rotating execution with light cover - flat body Options Pos. 3
RCF Reflex - fixed distance execution with light cover Standard Type A
RPF Reflex - fixed distance execution with heavy cover /B Type B
RXF Reflex - fixed distance execution with heavy cover - flat body /RV Right View
REF Reflex - fixed distance execution with heavy cover - flat body - flanged connections /LV Left View
TCR Transparent - rotating execution with light cover /MS Glass protection with MICA shield
TMR Transparent - rotating execution with light cover - flat body /KFS Glass protection with ECTFE shield
TCF Transparent - fixed distance execution with light cover
TMF Transparent - fixed distance execution with light cover - flat body
TPF Transparent - fixed distance execution with heavy cover
TXF Transparent - fixed distance execution with heavy cover - flat body
TEF Transparent - fixed distance execution with heavy cover - flat body - flanged connections
RCW Reflex - weld-on type with light cover
TCW Transparent - weld on type with light cover
TVR Tubular glass type

3 Process connections

Pos. 1: Nominal dimension Pos. 2: Nominal pressure Pos. 3: Type / Finish Pos. 4: Position
Standard Side / Side
/SB Side / Bottom
/TS Top / Side
4 Gauge Valves model /TB Top / Bottom

Pos. 1: Type of valves Pos. 2: Drain and Vent connection

0 None 0 Blind
PB Plug BSP
GR18 Cylindrical plug cocks PT Plug NPT
FL Flange
MT18 Cylindrical plug cocks - Monolithic body D12 Cylindrical plug cock (Standard)
D18 Cylindrical plug cock
NPV Push button valves PM18 Three way cylindrical plug manometer setting valve with control flange
SHV Globe valves DHV Globe valve
SBB Ball valves DBB Ball valve

5 Distance Centre-to-centre

M… Distance between connections centres in mm


M [SL…HL] Standard distance: see table in each level gauge type data-sheet

6 Materials

Pos. 1: Wetted parts Pos. 2: Non-wetted parts Pos. 3: Gaskets

CS Carbon steel ASTM A105 galvanized CS Carbon steel galvanized Standard Graphite / Copper
LF2 Carbon steel A105 LF2 galvanized SS Stainless steel AISI 316 GF Graphite / AISI 316
SS Stainless steel AISI 316L PC PTFE / Copper
BRS Brass PF PTFE / 316
GG EPDM (For glass tube)
7 Accessories

LC Lower check ball UC Upper check ball LUC Check balls (lower + upper)
LPH Lower pusher UPH Upper pusher LUPH Pusher (lower + upper)
VSG Calibrated scale NFE Non-frosting extension CR… Continuous reading
MLA Minimum level arrow EVA50 Bulb type illuminator TDR Microwave transmitter
GPU Glass tube protection MJT Middle terminal for glass tube CPTV Union nut for “U” shaped protection
LFC Weight closing for lower handle UFC Weight closing for upper handle LUFC Weight closing for all handles (lower + upper)
SMHD Cocks handles lock (all ) LU-SMHD Shut-off cocks handles lock D/V-SSHD Vent and drain handles lock
IFS Interface connection OP Painting SB Support bracket
ELC Remote control VP Vent pipe

8 Approvals

EEx ATEX SHP… Marine

Code 1 2 3 4 5 6 7 8

e.g. DS LG - RBF17 - 20/40/RF - GR18/D12/PB - M 420 - CS/CS - LC/VSG - EEx

Rev.2 Specifications and design can be subject to change without notice 1.3
DS DIESSE FLUID CONTROL

Product origin
Design & Manufacturing

REFLEX level gauges ITALY

The level is ascertained using a glass which has a smooth side and a wetted prismatic side. The level of the fluid inside the level gauge is shown by
using the optical principles of refraction: the wetted part fully absorbs light and so the fluid appears to be black. The part in contact with the gas, on the
other hand, fully reflects light and so the gas appears to be of a very light colour.

The product line includes level gauges suitable for pressure ratings from PN10 to PN250 and a huge number of industrial process applications.

This type of gauge is recommended:


for taking clear and simple readings (see counter-indications below)
if you are looking for an inexpensive gauge which will also save you money on
maintenance costs

Operating limits / Conditions:


Process:
Max. pressure: 255,5 bar @ 38°C (rating class 1500)
Max. temperature: 300°C (max. temperature allowed by borosilicate glasses as per the
DIN 7081 standard - see page 1.69)

Steam: (see page 1.59)


Max. pressure: 22 bar
Max. temperature: 216°C (saturated steam @ 22 bar)

For saturated steam values > 20 bar, a low-maintenance transparent level gauge with
mica shield protection should be used (see graph "Abrasion caused by boiler water"
for the estimated glass life).
Not only does the glass life depend on the temperature, it depends on the pH of the
water (the higher the value, the shorter the glass life).

The product is NOT suitable for use in the following instances:


q if exposed to corrosive fluid (e.g. caustic soda, hydrofluoric acid, citric acid ...)
q if exposed to high pressure steam
q if subjected to repeated thermal shocks
In the scenarios listed above, the glass must be protected with MICA or PCTFE shields, so a transparent level gauge is necessary
q for checking the level of separation between two immiscible fluids (interface)
q for checking the colour of a fluid (all fluids look very dark)
q in cases where the fluid is particularly viscous (a film may form on the glass which prevents you from taking an accurate reading)
q in cases where the fluid is particularly dark (the reflex principle is rendered ineffective)

Types:

PN16 PN40 PN40/64 PN40/64 PN100/160 PN160 PN250


Class 300 Class 300 Class 600/900 Class 900 Class 1500
DS DIESSE FLUID CONTROL

REFLEX level gauges

Materials / Specifications:
Connections between housing and cocks:
- with grinded pipes and stuffing box (View can be turned by the customer during installation)
- fixed centre-to-centre distance with metal seal (View can be turned during manufacture)
Wetted parts:
- standard: galvanized ASTM A105 or A105 LF2 carbon steel, ASTM A182 F316L stainless steel
- additional options: on request
Non-wetted parts:
- standard: galvanized carbon steel, AISI 316/316L stainless steel
- additional options: on request
Gaskets: (See page 1.71)
- standard: graphite/copper (ASTM A105), graphite/AISI 316 (A105 LF2 and ASTM A182 F316L)
- additional options: PTFE/AISI 316; other extras on request
Glasses: (See page 1.69)
- reflex borosilicate glasses, thermally pre-stressed and extra hard as per the DIN 7081 standard
Shut-off: (See page 1.49)
- standard: upper valve and lower valve (side/side)
- additional options: on request
Drain: (See page 1.50)
- standard: threaded valve
- additional options: on request
Vent: (See page 1.50)
- standard: blind (For grinded pipes version)
- threaded with plug (For fixed distance version)
- additional options: on request

Tank connections:
Flanged:
- UNI standard: PN40 DN15 / DN20 / DN25
- ANSI standard: #150 / #300 / #600 DN ½” / ¾” / 1”
- additional options: on request
Threaded:
- BSP (GAS) standard: ½”-M / ¾”-M
- NPT standard: ½”-M / ¾”-M
Weld-on: from ½” to 1” BW or SW
Option: further connections type or direct connections to the process without shut-off cocks (see page 1.49 for more details)

Shut-off cocks, drain cock and vent cock:


- Cylindrical plug cocks (GR18 or DS MT18 - see page 1.47)
- Globe valves (DS SHV - see page 1.48)
- Push-button valves (DS NPV - see page 1.48)
- Ball valves (DS SBB)

Spare parts:
Our spare parts are interchangeable with those of major international manufacturers.
For the full range of complete sets, turn to the spares section on page 1.69.

Accessories:
Lower and/or upper safety ball, pusher for safety ball, calibrated scale, non-frosting extension, minimum level arrow, continuous reading, cocks handles
lock (See page 1.55 for details)

Certifications (On request):


- ATEX
- Tests and inspection by Notified Bodies
- NACE MR0175
- Others on request

All DIESSE products are individually checked and tested in accordance with company quality procedures and the industry regulations currently in
effect.
Certificates can be issued on request.
Technical data

Service conditions
Max Pressure: PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase
REFLEX TYPE
PN40 Distance (Centre-to-centre)
Standard: see below table (Distance adjustable - 0 mm / + 10 mm)
Option: On request intermediate distances and over 3.000 mm
DS LG - RBR GR18
Materials (Standard)
Execution: CS/CS SS/CS
Gauge body & cocks body: ASTM A105 AISI 316L
Code: DS LG-RBR…-… /40/RF-GR18/…/…-M…-CS/CS Cocks trim: AISI 303 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
DS MT18: cylindrical plug type with monolithic body - Straight type - Quick 90° closing
(see page 1.47) Centre-to-centre distance M = B + 115 mm or 140 mm
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.49)
Vent: Standard: blind Option: see page 1.50
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.50

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69) Option: type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RBR: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 40 Nm

Spare parts
Housing DS RBR: see from page 1.69 (Drawing with components and parts list see page 1.61)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+105 M = B+130 VL x No. elements

11 1x1 130 235 260 95 115x1 2,4


12 2x1 155 260 285 120 140x1 2,8
13 3x1 180 285 310 145 165x1 3,3
14 4x1 205 310 335 170 190x1 3,8
15 5x1 235 340 365 200 220x1 4,3
16 6x1 265 370 395 230 250x1 4,9
17 7x1 295 400 425 260 280x1 5,4
18 8x1 335 440 465 300 320x1 6,1
19 9x1 360 465 490 320 340x1 6,6
24 4x2 410 515 540 375 190x2 7,5
25 5x2 470 575 600 435 220x2 8,5
26 6x2 530 635 660 495 250x2 9,7
27 7x2 590 695 720 555 280x2 10,7
28 8x2 670 775 800 635 320x2 12,1
29 9x2 720 825 850 680 340x2 13,1
36 6x3 795 900 925 760 250x3 14,4
37 7x3 885 990 1015 850 280x3 15,9
38 8x3 1005 1110 1145 970 320x3 18,0
39 9x3 1080 1185 1210 1040 340x3 19,5
47 7x4 1180 1285 1310 1145 280x4 21,2
48 8x4 1340 1445 1470 1305 320x4 24,0
49 9x4 1440 1545 1570 1400 340x4 26,0
57 7x5 1475 1580 1605 1440 280x5 26,5
58 8x5 1675 1780 1805 1640 320x5 30,0
59 9x5 1800 1905 1930 1760 340x5 32,5
68 8x6 2010 2115 2140 1975 320x6 35,9
69 9x6 2160 2265 2290 2120 340x6 38,9
78 8x7 2345 2450 2475 2310 320x7 41,9
79 9x7 2520 2625 2650 2480 340x7 45,4
88 8x8 2680 2785 2810 2645 320x8 47,9
89 9x8 2880 2985 3010 2840 340x8 51,9
Tab. RBR

Rev.2 Specifications and design can be subject to change without notice 1.7
Technical data

Service conditions
Max Pressure: PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
REFLEX TYPE
PN40 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm
DS LG - RBF GR18
Materials (Standard)
Execution: CS/CS SS/CS
Gauge body & cocks body: ASTM A105 AISI 316L
Code: DS LG-RBF…-… /40/RF-GR18/…/…-M…-CS/CS Cocks trim: AISI 303 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69) Option: type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RBF: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 40 Nm

Spare parts
Housing DS RBR: see from page 1.69 (Drawing with components and parts list see page 1.61)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+40 VL x No. elements

11 1x1 130 170 95 115x1 3,7


12 2x1 155 195 120 140x1 4,1
13 3x1 180 220 145 165x1 4,6
14 4x1 205 245 170 190x1 5,1
15 5x1 235 275 200 220x1 5,6
16 6x1 265 305 230 250x1 6,2
17 7x1 295 335 260 280x1 6,7
18 8x1 335 375 300 320x1 7,4
19 9x1 360 400 320 340x1 7,9
24 4x2 410 450 375 190x2 8,8
25 5x2 470 510 435 220x2 9,8
26 6x2 530 570 495 250x2 11,0
27 7x2 590 630 555 280x2 12,0
28 8x2 670 710 635 320x2 13,4
29 9x2 720 760 680 340x2 14,4
36 6x3 795 835 760 250x3 15,7
37 7x3 885 925 850 280x3 17,2
38 8x3 1005 1045 970 320x3 19,3
39 9x3 1080 1120 1040 340x3 20,8
47 7x4 1180 1220 1145 280x4 22,5
48 8x4 1340 1380 1305 320x4 25,3
49 9x4 1440 1480 1400 340x4 27,3
57 7x5 1475 1515 1440 280x5 27,8
58 8x5 1675 1715 1640 320x5 31,3
59 9x5 1800 1840 1760 340x5 33,8
68 8x6 2010 2050 1975 320x6 37,2
69 9x6 2160 2200 2120 340x6 40,2
78 8x7 2345 2385 2310 320x7 43,2
79 9x7 2520 2560 2480 340x7 46,7
88 8x8 2680 2720 2645 320x8 49,3
89 9x8 2880 2920 2840 340x8 53,2
Tab. RBF

Rev.2 Specifications and design can be subject to change without notice 1.8
Technical data

Service conditions
Max Pressure: PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase
REFLEX TYPE
PN40 Distance (Centre-to-centre)
Standard: see below table (Distance adjustable - 0 mm / + 10 mm)
Option: On request intermediate distances and over 3.000 mm
DS LG - RCR GR18
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Code: DS LG-RCR…-… /40/RF-GR18/…/…-M…-CS/CS Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.49)
Vent: Standard: blind Option: see page 1.50
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.50

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RCR: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS RCR: see from page 1.69 (Drawing with components and parts list see page 1.62)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+105 M = B+130 VL x No. elements

11 1x1 130 235 260 95 115x1 3,0


12 2x1 155 260 285 120 140x1 3,5
13 3x1 180 285 310 145 165x1 4,0
14 4x1 205 310 335 170 190x1 4,4
15 5x1 235 340 365 200 220x1 5,2
16 6x1 265 370 395 230 250x1 5,6
17 7x1 295 400 425 260 280x1 6,3
18 8x1 335 440 465 300 320x1 7,0
19 9x1 360 465 490 320 340x1 7,6
24 4x2 410 515 540 375 190x2 8,6
25 5x2 470 575 600 435 220x2 10,2
26 6x2 530 635 660 495 250x2 11,0
27 7x2 590 695 720 555 280x2 12,5
28 8x2 670 775 800 635 320x2 13,8
29 9x2 720 825 850 680 340x2 15,0
36 6x3 795 900 925 760 250x3 16,5
37 7x3 885 990 1015 850 280x3 18,6
38 8x3 1005 1110 1145 970 320x3 20,7
39 9x3 1080 1185 1210 1040 340x3 22,5
47 7x4 1180 1285 1310 1145 280x4 24,7
48 8x4 1340 1445 1470 1305 320x4 27,5
49 9x4 1440 1545 1570 1400 340x4 29,9
57 7x5 1475 1580 1605 1440 280x5 30,8
58 8x5 1675 1780 1805 1640 320x5 34,3
59 9x5 1800 1905 1930 1760 340x5 37,3
68 8x6 2010 2115 2140 1975 320x6 41,3
69 9x6 2160 2265 2290 2120 340x6 44,8
78 8x7 2345 2450 2475 2310 320x7 48,0
79 9x7 2520 2625 2650 2480 340x7 52,2
88 8x8 2680 2785 2810 2645 320x8 54,8
89 9x8 2880 2985 3010 2840 340x8 59,6
Tab. RCR

Rev.2 Specifications and design can be subject to change without notice 1.9
Technical data

Service conditions
Max Pressure: PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase
REFLEX TYPE
PN40 Distance (Centre-to-centre)
Standard: see below table (Distance adjustable - 0 mm / + 10 mm)
Option: On request intermediate distances and over 500 mm
DS LG - RDR GR18 / SHV
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 AISI 316L AISI 316L
Cocks body DS GR18: ASTM A105 AISI 316L AISI 316L
Cocks trim: AISI 303 AISI 316 AISI 316
Valves body DS SHV: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Code: DS LG-RDR…-… /40/RF-GR18/…/…-M…-CS/CS Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Valves DS SHV: globe type - Opening/Closing by handwheel
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.49)
Vent: Standard: blind Option: see page 1.50
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.50

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN40-64 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69) Option: type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RDR: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)
Code: DS LG-RDR…-… /40/RF-SHV/…/…-M…-CS/CS Valves DS SHV: Kg. 11,8 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS RDR: see from page 1.69 (Drawing with components and parts list see page 1.62)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el B M = B+105 M = B+130 VL

11 1x1 130 235 260 95 115 2,9


12 2x1 155 260 285 120 140 3,4
13 3x1 180 285 310 145 165 3,8
14 4x1 205 310 335 170 190 4,4
15 5x1 235 340 365 200 220 5,2
16 6x1 265 370 395 230 250 5,6
17 7x1 295 400 425 260 280 6,0
18 8x1 335 440 465 300 320 6,5
19 9x1 360 465 490 320 340 7,5
Tab. RDR

Rev.2 Specifications and design can be subject to change without notice 1.10
Technical data

Service conditions
Max Pressure: PN40 and PN64; Class 300 (A105: 51 bar @ 38°C; AISI 316L: 49,6 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
REFLEX TYPE
PN40 and PN64 / Class 300 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm
DS LG - RCF GR18
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Code: DS LG-RCF…-… /40/RF-GR18/…/…-M…-CS/CS Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN40-64 DN15-20-25 ANSI #150-300-600/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RCF: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS RCF: see from page 1.69 (Drawing with components and parts list see page 1.62)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+40 VL x No. elements

11 1x1 130 170 95 115x1 4,3


12 2x1 155 195 120 140x1 4,8
13 3x1 180 220 145 165x1 5,3
14 4x1 205 245 170 190x1 5,7
15 5x1 235 275 200 220x1 6,5
16 6x1 265 305 230 250x1 6,9
17 7x1 295 335 260 280x1 7,6
18 8x1 335 375 300 320x1 8,3
19 9x1 360 400 320 340x1 8,9
24 4x2 410 450 375 190x2 9,9
25 5x2 470 510 435 220x2 11,5
26 6x2 530 570 495 250x2 12,3
27 7x2 590 630 555 280x2 13,8
28 8x2 670 710 635 320x2 15,1
29 9x2 720 760 680 340x2 16,3
36 6x3 795 835 760 250x3 17,8
37 7x3 885 925 850 280x3 19,9
38 8x3 1005 1045 970 320x3 22,0
39 9x3 1080 1120 1040 340x3 23,8
47 7x4 1180 1220 1145 280x4 26,0
48 8x4 1340 1380 1305 320x4 28,8
49 9x4 1440 1480 1400 340x4 31,2
57 7x5 1475 1515 1440 280x5 32,1
58 8x5 1675 1715 1640 320x5 35,6
59 9x5 1800 1840 1760 340x5 38,6
68 8x6 2010 2050 1975 320x6 42,6
69 9x6 2160 2200 2120 340x6 46,1
78 8x7 2345 2385 2310 320x7 49,3
79 9x7 2520 2560 2480 340x7 53,5
88 8x8 2680 2720 2645 320x8 56,1
89 9x8 2880 2920 2840 340x8 60,9
Tab. RCF

Rev.2 Specifications and design can be subject to change without notice 1.11
Technical data

Service conditions
Max Pressure: PN40 and PN64; Class 300 (A105: 51 bar @ 38°C; AISI 316L: 49,6 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
REFLEX TYPE
PN40 and PN64 / Class 300 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm
DS LG - RCF SHV
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Code: DS LG-RCF…-… /40/RF-SHV/…/…-M…-CS/CS Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN40-64 DN15-20-25 ANSI #150-300-600/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RCF: see below table
Valves DS SHV: Kg. 11,8 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS RCF: see from page 1.69 (Drawing with components and parts list see page 1.62)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 4,3


12 2x1 155 235 120 140x1 4,8
13 3x1 180 260 145 165x1 5,3
14 4x1 205 285 170 190x1 5,7
15 5x1 235 315 200 220x1 6,5
16 6x1 265 345 230 250x1 6,9
17 7x1 295 375 260 280x1 7,6
18 8x1 335 415 300 320x1 8,3
19 9x1 360 440 320 340x1 8,9
24 4x2 410 490 375 190x2 9,9
25 5x2 470 550 435 220x2 11,5
26 6x2 530 610 495 250x2 12,3
27 7x2 590 670 555 280x2 13,8
28 8x2 670 750 635 320x2 15,1
29 9x2 720 800 680 340x2 16,3
36 6x3 795 875 760 250x3 17,8
37 7x3 885 965 850 280x3 19,9
38 8x3 1005 1085 970 320x3 22,0
39 9x3 1080 1160 1040 340x3 23,8
47 7x4 1180 1260 1145 280x4 26,0
48 8x4 1340 1420 1305 320x4 28,8
49 9x4 1440 1520 1400 340x4 31,2
57 7x5 1475 1555 1440 280x5 32,1
58 8x5 1675 1755 1640 320x5 35,6
59 9x5 1800 1880 1760 340x5 38,6
68 8x6 2010 2090 1975 320x6 42,6
69 9x6 2160 2240 2120 340x6 46,1
78 8x7 2345 2425 2310 320x7 49,3
79 9x7 2520 2600 2480 340x7 53,5
88 8x8 2680 2760 2645 320x8 56,1
89 9x8 2880 2960 2840 340x8 60,9
Tab. RCF

Rev.2 Specifications and design can be subject to change without notice 1.12
Technical data

Service conditions
Max Pressure: PN100; Class 600 (A105: 102 bar @ 38°C; AISI 316L: 99,3 bar @ 38°C) and
PN160; Class 900 (A105: 153,1 bar @ 38°C; AISI 316L: 148,9 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)
GLASS LEVEL GAUGE
View
REFLEX TYPE Standard: front, on request lateral (right or left) adjustable in the production phase
PN100 and PN160 / Class 600 and 900
Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
DS LG - RPF GR18 Option: On request intermediate distances and over 2.000 mm

Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Code: DS LG-RPF…-… /100/RF-GR18/…/…-M…-CS/CS Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN100-160 DN20 - DN25 ANSI #600-900/RF DN ¾“ - 1“
Standard threaded unions: BSP-M ¾” - 1” NPT-M ¾” - 1”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RPF: see below table
Cocks DS GR18: Kg. 9,2 approx. (With flanges UNI DN20 PN100)

Tightening torque of housing screws


Standard: 75 Nm

Spare parts
Housing DS RPF: see from page 1.69 (Drawing with components and parts list see page 1.63)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+50 VL x No. elements

11 1x1 130 180 95 115x1 7,7


12 2x1 155 205 120 140x1 8,6
13 3x1 180 230 145 165x1 9,9
14 4x1 205 255 170 190x1 11,0
15 5x1 235 285 200 220x1 12,3
16 6x1 265 315 230 250x1 13,1
17 7x1 295 345 260 280x1 14,8
18 8x1 335 385 300 320x1 16,0
19 9x1 360 410 320 340x1 17,7
24 4x2 410 460 375 190x2 20,5
25 5x2 470 520 435 220x2 23,1
26 6x2 530 580 495 250x2 24,7
27 7x2 590 640 555 280x2 28,1
28 8x2 670 720 635 320x2 30,5
29 9x2 720 770 680 340x2 33,9
36 6x3 795 845 760 250x3 36,3
37 7x3 885 935 850 280x3 41,4
38 8x3 1005 1055 970 320x3 45,0
39 9x3 1080 1130 1040 340x3 50,1
47 7x4 1180 1230 1145 280x4 54,7
48 8x4 1340 1390 1305 320x4 59,5
49 9x4 1440 1490 1400 340x4 66,3
57 7x5 1475 1525 1440 280x5 68,0
58 8x5 1675 1725 1640 320x5 74,0
59 9x5 1800 1850 1760 340x5 82,5
Tab. RPF

Rev.2 Specifications and design can be subject to change without notice 1.13
Technical data

Service conditions
Max Pressure: PN100; Class 600 (A105: 102 bar @ 38°C; AISI 316L: 99,3 bar @ 38°C) and
PN160; Class 900 (A105: 153,1 bar @ 38°C; AISI 316L: 148,9 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)
GLASS LEVEL GAUGE
View
REFLEX TYPE Standard: front, on request lateral (right or left) adjustable in the production phase
PN100 and PN160 / Class 600 and 900
Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
DS LG - RPF SHV Option: On request intermediate distances and over 2.000 mm

Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Code: DS LG-RPF…-… /100/RF-SHV/…/…-M…-CS/CS Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN100-160 DN20-25 ANSI #600-900/RF DN ¾“ - 1“
Standard threaded unions: BSP-M ¾” - 1” NPT-M ¾” - 1”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RPF: see below table
Valves DS SHV: Kg. 13,5 approx. (With flanges UNI DN20 PN100)

Tightening torque of housing screws


Standard: 75 Nm

Spare parts
Housing DS RPF: see from page 1.69 (Drawing with components and parts list see page 1.63)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 7,7


12 2x1 155 235 120 140x1 8,6
13 3x1 180 260 145 165x1 9,9
14 4x1 205 285 170 190x1 11,0
15 5x1 235 315 200 220x1 12,3
16 6x1 265 345 230 250x1 13,1
17 7x1 295 375 260 280x1 14,8
18 8x1 335 415 300 320x1 16,0
19 9x1 360 440 320 340x1 17,7
24 4x2 410 490 375 190x2 20,5
25 5x2 470 550 435 220x2 23,1
26 6x2 530 610 495 250x2 24,7
27 7x2 590 670 555 280x2 28,1
28 8x2 670 750 635 320x2 30,5
29 9x2 720 800 680 340x2 33,9
36 6x3 795 875 760 250x3 36,3
37 7x3 885 965 850 280x3 41,4
38 8x3 1005 1085 970 320x3 45,0
39 9x3 1080 1160 1040 340x3 50,1
47 7x4 1180 1260 1145 280x4 54,7
48 8x4 1340 1420 1305 320x4 59,5
49 9x4 1440 1520 1400 340x4 66,3
57 7x5 1475 1555 1440 280x5 68,0
58 8x5 1675 1755 1640 320x5 74,0
59 9x5 1800 1880 1760 340x5 82,5
Tab. RPF

Rev.2 Specifications and design can be subject to change without notice 1.14
Technical data

Service conditions
Max Pressure: PN160; Class 900 (A105: 153,1 bar @ 38°C; AISI 316L: 148,9 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
REFLEX TYPE
PN160 / Class 900 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 2.000 mm
DS LG - RXF GR18
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Code: DS LG-RXF…-… /160/RF-GR18/…/…-M…-CS/CS Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN160 DN20 - DN25 ANSI #900/RF DN ¾“ - 1“
Standard threaded unions: BSP-M ¾” - 1” NPT-M ¾” - 1”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RXF: see below table
Cocks DS GR18: Kg. 9,2 approx. (With flanges UNI DN20 PN100)

Tightening torque of housing screws


Standard: 75 Nm

Spare parts
Housing DS RXF: see from page 1.69 (Drawing with components and parts list see page 1.63)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+50 VL x No. elements

11 1x1 130 180 95 115x1 11,3


12 2x1 155 205 120 140x1 12,7
13 3x1 180 230 145 165x1 14,4
14 4x1 205 255 170 190x1 15,5
15 5x1 235 285 200 220x1 17,7
16 6x1 265 315 230 250x1 19,0
17 7x1 295 345 260 280x1 21,3
18 8x1 335 385 300 320x1 23,1
19 9x1 360 410 320 340x1 25,2
24 4x2 410 460 375 190x2 28,0
25 5x2 470 520 435 220x2 32,4
26 6x2 530 580 495 250x2 35,0
27 7x2 590 640 555 280x2 39,6
28 8x2 670 720 635 320x2 43,2
29 9x2 720 770 680 340x2 47,4
36 6x3 795 845 760 250x3 51,0
37 7x3 885 935 850 280x3 57,9
38 8x3 1005 1055 970 320x3 63,3
39 9x3 1080 1130 1040 340x3 69,6
47 7x4 1180 1230 1145 280x4 76,2
48 8x4 1340 1390 1305 320x4 83,4
49 9x4 1440 1490 1400 340x4 91,8
57 7x5 1475 1525 1440 280x5 94,5
58 8x5 1675 1725 1640 320x5 103,5
59 9x5 1800 1850 1760 340x5 114,0
Tab. RXF

Rev.2 Specifications and design can be subject to change without notice 1.15
Technical data

Service conditions
Max Pressure: PN160; Class 900 (A105: 153,1 bar @ 38°C; AISI 316L: 148,9 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
REFLEX TYPE
PN160 / Class 900 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 2.000 mm
DS LG - RXF SHV
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Code: DS LG-RXF…-… /160/RF-SHV/…/…-M…-CS/CS Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN160 DN20-25 ANSI #900/RF DN ¾“ - 1“
Standard threaded unions: BSP-M ¾” - 1” NPT-M ¾” - 1”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RXF: see below table
Valves DS SHV: Kg. 13,5 approx. (With flanges UNI DN20 PN160)

Tightening torque of housing screws


Standard: 75 Nm

Spare parts
Housing DS RXF: see from page 1.69 (Drawing with components and parts list see page 1.63)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 11,3


12 2x1 155 235 120 140x1 12,7
13 3x1 180 260 145 165x1 14,4
14 4x1 205 285 170 190x1 15,5
15 5x1 235 315 200 220x1 17,7
16 6x1 265 345 230 250x1 19,0
17 7x1 295 375 260 280x1 21,3
18 8x1 335 415 300 320x1 23,1
19 9x1 360 440 320 340x1 25,2
24 4x2 410 490 375 190x2 28,0
25 5x2 470 550 435 220x2 32,4
26 6x2 530 610 495 250x2 35,0
27 7x2 590 670 555 280x2 39,6
28 8x2 670 750 635 320x2 43,2
29 9x2 720 800 680 340x2 47,4
36 6x3 795 875 760 250x3 51,0
37 7x3 885 965 850 280x3 57,9
38 8x3 1005 1085 970 320x3 63,3
39 9x3 1080 1160 1040 340x3 69,6
47 7x4 1180 1260 1145 280x4 76,2
48 8x4 1340 1420 1305 320x4 83,4
49 9x4 1440 1520 1400 340x4 91,8
57 7x5 1475 1555 1440 280x5 94,5
58 8x5 1675 1755 1640 320x5 103,5
59 9x5 1800 1880 1760 340x5 114,0
Tab. RXF

Rev.2 Specifications and design can be subject to change without notice 1.16
Technical data

Service conditions
Max Pressure: PN250; Class 1500 (A105: 255,5 bar @ 38°C; AISI 316L: 239,2 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
REFLEX TYPE
PN250 / Class 1500 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 2.000 mm
DS LG - REF SHV
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Code: DS LG-REF…-… /1500/…-SHV/…/…-M…-CS/CS Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/AISI 316 Option: PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN250 DN On request ANSI #1500 DN On request
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B, thickness 21 mm (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS REF: see below table
Valves DS SHV: Kg. 16,5 approx. (With flanges 1” ANSI 1500#RF)

Tightening torque of housing screws


Standard: 90 Nm

Spare parts
Housing DS REF: see from page 1.69 (Drawing with components and parts list see page 1.63)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 13,4


12 2x1 155 235 120 140x1 15,2
13 3x1 180 260 145 165x1 17,3
14 4x1 205 285 170 190x1 18,8
15 5x1 235 315 200 220x1 21,5
16 6x1 265 345 230 250x1 23,3
17 7x1 295 375 260 280x1 26,0
18 8x1 335 415 300 320x1 28,5
19 9x1 360 440 320 340x1 31,0
24 4x2 410 490 375 190x2 34,6
25 5x2 470 550 435 220x2 40,0
26 6x2 530 610 495 250x2 43,5
27 7x2 590 670 555 280x2 49,1
28 8x2 670 750 635 320x2 53,9
29 9x2 720 800 680 340x2 59,0
36 6x3 795 875 760 250x3 63,7
37 7x3 885 965 850 280x3 72,1
38 8x3 1005 1085 970 320x3 79,4
39 9x3 1080 1160 1040 340x3 86,9
47 7x4 1180 1260 1145 280x4 95,1
48 8x4 1340 1420 1305 320x4 104,9
49 9x4 1440 1520 1400 340x4 114,9
57 7x5 1475 1555 1440 280x5 118,1
58 8x5 1675 1755 1640 320x5 130,3
59 9x5 1800 1880 1760 340x5 142,8
Tab. REF

Rev.2 Specifications and design can be subject to change without notice 1.16.1
Technical data

Service conditions
Max Pressure: PN16
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase
REFLEX TYPE
PN16 Distance (Centre-to-centre)
Standard: see below table (Distance adjustable - 0 mm / + 10 mm)

DS LG - RTR GR18 / MT18 Materials (Standard)


Execution: CS/CS
Gauge body & cocks body: ASTM A105
Cocks trim: AISI 303
Code: DS LG-RTR…-… /16/RF-GR18/…/…-M…-CS/CS Non-wetted parts: Carbon steel galvanized

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
DS MT18: cylindrical plug type with monolithic body - Straight type - Quick 90° closing
(see page 1.47) Centre-to-centre distance M = B + 115 mm or 140 mm
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN16/40 DN15-20-25 ANSI #150/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.49)
Vent: Standard: blind Option: see page 1.50
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.50

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RTR: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)
Cocks DS MT18: Kg. 6,1 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 25 Nm

Spare parts
Housing DS RTR: see from page 1.69 (Drawing with components and parts list see page 1.61)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)
Cocks DS MT18: see from page 1.72 (Drawing with components and parts list see page 1.67)

With cocks type DS GR18:

Code: DS LG-RTR…-… /16/RF-MT18/…/…-M…-CS/CS CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT
Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+105 M = B+130 VL x No. elements

11 1x1 130 235 260 95 115x1 1,8


12 2x1 155 260 285 120 140x1 2,0
13 3x1 180 285 310 145 165x1 2,2
14 4x1 205 310 335 170 190x1 2,5
15 5x1 235 340 365 200 220x1 2,9
16 6x1 265 370 395 230 250x1 3,2
17 7x1 295 400 425 260 280x1 3,6
18 8x1 335 440 465 300 320x1 4,0
19 9x1 360 465 490 320 340x1 4,3
Tab. RTR
With cocks type DS MT18 (Monolithic body):

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+115 M = B+140 VL x No. elements

11 1x1 130 245 270 95 115x1 1,8


12 2x1 155 270 295 120 140x1 2,0
13 3x1 180 295 320 145 165x1 2,2
14 4x1 205 320 345 170 190x1 2,5
15 5x1 235 350 375 200 220x1 2,9
16 6x1 265 380 405 230 250x1 3,2
17 7x1 295 410 435 260 280x1 3,6
18 8x1 335 450 475 300 320x1 4,0
19 9x1 360 475 500 320 340x1 4,3
Tab. RTRMT

Rev.2 Specifications and design can be subject to change without notice 1.17
Technical data

Service conditions
Max Pressure: PN16
Max Temperature:
- With PTFE gaskets and ball valves DS SBB: 120°C
GLASS LEVEL GAUGE - With graphite gaskets and cylindrical plug cocks DS D12: 170°C
REFLEX TYPE View
PN16 Standard: front, on request lateral (right or left) adjustable in the production phase

Distance (Centre-to-centre)
DS LG - RTF SBB / D12 On request, Fixed distance, not adjustable

Materials (Standard)
Execution: CS/CS
Gauge body: ASTM A105
Body, ball and sealing of ball valves DS SBB: Brass (CW617N) / Brass (CW617N) / PTFE
Body, trim and sealing of cocks DS D12: ASTM A105 / AISI 303 / Graphite
Non-wetted parts: Carbon steel galvanized
Code: DS LG-RTF…-1/2”GASM-SBB/DBB/PB-M…-CS/CS
Gaskets
Standard: PTFE/copper Option: graphite/copper

Valves
Standard: ball valves DS SBB threaded 1/2” BSP-M - Quick 90° closing
Handling: lever operated

Option: on request cylindrical plug cocks DS D12 threaded 1/2” BSP-M or 1/2” BSP-F - Quick 90°
closing (See page 3.3)
Handling: lever operated with PP handle

Process connections:
Standard: threaded 1/2” BSP-M (With ball valves DS SBB)
threaded 1/2” BSP-F (With revolving female connections - without valves)

Vent:
Standard: threaded 3/8” BSP-F with plug

Drain:
Standard: ball valve DS DBB threaded 3/8” BSP-F - Quick 90° closing
Handling: lever operated

Option:
on request with cylindrical plug cocks DS D12 threaded 3/8” BSP-F or BSP-M

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RTF: see below table
Ball valve DS SBB: Kg. 0,2 unit approx.
Cock DS D12: Kg. 0,5 unit approx.

Tightening torque of housing screws


Standard: 20 Nm

Spare parts
Housing DS RTF: see from page 1.69 (Drawing with components and parts list see page 1.61)
Cocks DS D12: see from page 1.72

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M VL

11 1x1 130 On request 95 115 1,8


12 2x1 155 On request 120 140 2,0
13 3x1 180 On request 145 165 2,2
14 4x1 205 On request 170 190 2,5
15 5x1 235 On request 200 220 2,9
16 6x1 265 On request 230 250 3,2
17 7x1 295 On request 260 280 3,6
18 8x1 335 On request 300 320 4,0
19 9x1 360 On request 320 340 4,3
Tab. RTF

Rev.2 Specifications and design can be subject to change without notice 1.18
Technical data

Service conditions
Max Pressure: PN25
Max Temperature: 170°C

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
REFLEX TYPE
PN25 Distance (Centre-to-centre)
On request, Fixed distance, not adjustable

DS LG - RBFPM D18 Materials (Standard)


Execution: CS/CS
Gauge body & cocks body: ASTM A105
Cocks trim: AISI 303
Non-wetted parts: Carbon steel galvanized

Gaskets
Standard: graphite/copper

Shut-off cocks
Standard: cylindrical plug cocks DS D18 threaded 1/2” BSP-F - Quick 90° closing (See page 3.4)
Handling: lever operated with PP handle

Process connections:
Standard: threaded 1/2” BSP-F (With cylindrical plug cocks DS D18)
threaded M28x2-F (With revolving female connections - without valves)

Vent:
Standard: three way cylindrical plug manometer setting valve with control flange DS PM18
threaded 1/2” BSP-F (See page 3.5)
Handling: lever operated with PP handle
Code: DS LG-RBFPM…-1/2”GASF-D18/D12/PM18-M…-CS/CS Option: on request threaded 1/2" BSP-F with plug (Without cock)

Drain:
Standard: with cylindrical plug cock DS D12 threaded 1/2” BSP-M with drain tube - Quick 90°
closing (See page 3.3)
Handling: lever operated with PP handle

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)
Option: type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RBFPM: see below table
Cocks DS D18: Kg. 0,9 unit approx.
Cock DS PM18: Kg. 1,2 unit approx.
Cock DS D12: Kg. 0,5 unit approx.

Tightening torque of housing screws


Standard: 40 Nm

Spare parts
Housing DS RBFPM: see from page 1.69 (Drawing with components and parts list see page 1.61)
Cocks DS D18: see from page 1.72
Cock DS PM18: see from page 1.72
Cock DS D12: see from page 1.72

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M VL

11 1x1 130 On request 95 115 2,4


12 2x1 155 On request 120 140 2,8
13 3x1 180 On request 145 165 3,3
14 4x1 205 On request 170 190 3,8
15 5x1 235 On request 200 220 4,3
16 6x1 265 On request 230 250 4,9
17 7x1 295 On request 260 280 5,4
18 8x1 335 On request 300 320 6,1
19 9x1 360 On request 320 340 6,6
Tab. RBFPM

Rev.2 Specifications and design can be subject to change without notice 1.19
DS DIESSE
FLUID CONTROL

Product origin
Design & Manufacturing

MARINE LEVEL GAUGES ITALY

On request the product is available also with


the approval certificate of Lloyd's Register
Technical data

Service conditions
Pressione max: PN16
Temperatura max: 150°C

GLASS LEVEL GAUGE Application


Fluid storage tanks also aboard of ships
REFLEX TYPE
PN16 View
Standard: front, on request lateral (right or left) adjustable in the production phase

DS LG - RBF NPV Distance (Centre-to-centre)


Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm

Code: DS LG-RBF…-… /40/RF-NPV/…/…-M…-CS/CS Materials (Standard)


Execution: CS/CS SS/CS
Gauge body & valve body: ASTM A105 AISI 316L
Stem and disc: AISI 410 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Self-closing Valve
DS NPV: self-closing, push button type
Handling: opening by push button (Standard: valve on the right side; On request on the left side)
Process connections:
Standard flange: UNI PN16 DN15-20-25 ANSI #150/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Option: further connections types
Vent: Standard: threaded ½” with vent pipe Option: on request (See details at page 1.52)
Drain: Standard: threaded ½” with plug Option: on request (See details at page 1.52)

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69) Option: type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RBF: see below table
Valve DS NPV: Kg. 2,6 approx. (With flanges UNI DN20 PN16)

Tightening torque of housing screws


Standard: 40 Nm

Spare parts
Housing DS RBF: see from page 1.69 (Drawing with components and parts list see page 1.61)
Valve DS NPV: see from page 1.74 (Drawing with components and parts list see page 1.67)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+60 VL x No. elements

11 1x1 130 190 95 115x1 3,7


12 2x1 155 215 120 140x1 4,1
13 3x1 180 240 145 165x1 4,6
14 4x1 205 265 170 190x1 5,1
15 5x1 235 295 200 220x1 5,6
16 6x1 265 325 230 250x1 6,2
17 7x1 295 355 260 280x1 6,7
18 8x1 335 395 300 320x1 7,4
19 9x1 360 420 320 340x1 7,9
24 4x2 410 470 375 190x2 8,8
25 5x2 470 530 435 220x2 9,8
26 6x2 530 590 495 250x2 11,0
27 7x2 590 650 555 280x2 12,0
28 8x2 670 730 635 320x2 13,4
29 9x2 720 780 680 340x2 14,4
36 6x3 795 855 760 250x3 15,7
37 7x3 885 945 850 280x3 17,2
38 8x3 1005 1065 970 320x3 19,3
39 9x3 1080 1140 1040 340x3 20,8
47 7x4 1180 1240 1145 280x4 22,5
48 8x4 1340 1400 1305 320x4 25,3
49 9x4 1440 1500 1400 340x4 27,3
57 7x5 1475 1535 1440 280x5 27,8
58 8x5 1675 1735 1640 320x5 31,3
59 9x5 1800 1860 1760 340x5 33,8
68 8x6 2010 2070 1975 320x6 37,2
69 9x6 2160 2220 2120 340x6 40,2
78 8x7 2345 2405 2310 320x7 43,2
79 9x7 2520 2580 2480 340x7 46,7
88 8x8 2680 2740 2645 320x8 49,3
89 9x8 2880 2940 2840 340x8 53,2
Tab. RBF
Rev.2 Specifications and design can be subject to change without notice 1.20
Technical data

Service conditions
Max Pressure: PN25 and PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE Application


Fluid storage tanks also aboard of ships
REFLEX TYPE
PN25 and PN40 / Class 150 View
Standard: adjustable on 360° in the installation phase

DS LG - RBR GR18 - LFC Distance (Centre-to-centre)


Standard: see below table (Distance adjustable - 0 mm / + 10 mm)
Option: On request intermediate distances and over 3.000 mm

Code: DS LG-RBR…-… /40/RF-GR18/…/…-M…-CS/CS-LFC Materials (Standard)


Execution: CS/CS SS/CS
Gauge body & cocks body: ASTM A105 AISI 316L
Cocks trim: AISI 303 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Lower cock with weight closing accessory for self closing
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types to the process (See page 1.49)
Vent: Standard: blind Option: see page 1.50
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.50

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69) Option: type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RBR: see below table
Cocks DS GR18 with weight closing for lower handle: Kg. 10,8 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 40 Nm

Spare parts
Housing DS RBR: see from page 1.69 (Drawing with components and parts list see page 1.61)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+105 M = B+130 VL x No. elements

11 1x1 130 235 260 95 115x1 2,4


12 2x1 155 260 285 120 140x1 2,8
13 3x1 180 285 310 145 165x1 3,3
14 4x1 205 310 335 170 190x1 3,8
15 5x1 235 340 365 200 220x1 4,3
16 6x1 265 370 395 230 250x1 4,9
17 7x1 295 400 425 260 280x1 5,4
18 8x1 335 440 465 300 320x1 6,1
19 9x1 360 465 490 320 340x1 6,6
24 4x2 410 515 540 375 190x2 7,5
25 5x2 470 575 600 435 220x2 8,5
26 6x2 530 635 660 495 250x2 9,7
27 7x2 590 695 720 555 280x2 10,7
28 8x2 670 775 800 635 320x2 12,1
29 9x2 720 825 850 680 340x2 13,1
36 6x3 795 900 925 760 250x3 14,4
37 7x3 885 990 1015 850 280x3 15,9
38 8x3 1005 1110 1145 970 320x3 18,0
39 9x3 1080 1185 1210 1040 340x3 19,5
47 7x4 1180 1285 1310 1145 280x4 21,2
48 8x4 1340 1445 1470 1305 320x4 24,0
49 9x4 1440 1545 1570 1400 340x4 26,0
57 7x5 1475 1580 1605 1440 280x5 26,5
58 8x5 1675 1780 1805 1640 320x5 30,0
59 9x5 1800 1905 1930 1760 340x5 32,5
68 8x6 2010 2115 2140 1975 320x6 35,9
69 9x6 2160 2265 2290 2120 340x6 38,9
78 8x7 2345 2450 2475 2310 320x7 41,9
79 9x7 2520 2625 2650 2480 340x7 45,4
88 8x8 2680 2785 2810 2645 320x8 47,9
89 9x8 2880 2985 3010 2840 340x8 51,9
Tab. RBR

Rev.2 Specifications and design can be subject to change without notice 1.21
Technical data

Service conditions
Max Pressure: PN25 and PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE Application


Fluid storage tanks also aboard of ships
REFLEX TYPE
PN25 and PN40 / Class 150 View
Standard: front, on request lateral (right or left) adjustable in the production phase

DS LG - RBF GR18 - LFC Distance (Centre-to-centre)


Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm

Code: DS LG-RBF…-… /40/RF-GR18/…/…-M…-CS/CS - LFC Materials (Standard)


Execution: CS/CS SS/CS
Gauge body & cocks body: ASTM A105 AISI 316L
Cocks trim: AISI 303 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Lower cock with weight closing accessory for self closing
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300-600/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types to the process (see page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Reflex - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69) Option: type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS RBF: see below table
Cocks DS GR18 with weight closing for lower handle: Kg. 10,8 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 40 Nm

Spare parts
Housing DS RBR: see from page 1.69 (Drawing with components and parts list see page 1.61)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+40 VL x No. elements

11 1x1 130 170 95 115x1 3,7


12 2x1 155 195 120 140x1 4,1
13 3x1 180 220 145 165x1 4,6
14 4x1 205 245 170 190x1 5,1
15 5x1 235 275 200 220x1 5,6
16 6x1 265 305 230 250x1 6,2
17 7x1 295 335 260 280x1 6,7
18 8x1 335 375 300 320x1 7,4
19 9x1 360 400 320 340x1 7,9
24 4x2 410 450 375 190x2 8,8
25 5x2 470 510 435 220x2 9,8
26 6x2 530 570 495 250x2 11,0
27 7x2 590 630 555 280x2 12,0
28 8x2 670 710 635 320x2 13,4
29 9x2 720 760 680 340x2 14,4
36 6x3 795 835 760 250x3 15,7
37 7x3 885 925 850 280x3 17,2
38 8x3 1005 1045 970 320x3 19,3
39 9x3 1080 1120 1040 340x3 20,8
47 7x4 1180 1220 1145 280x4 22,5
48 8x4 1340 1380 1305 320x4 25,3
49 9x4 1440 1480 1400 340x4 27,3
57 7x5 1475 1515 1440 280x5 27,8
58 8x5 1675 1715 1640 320x5 31,3
59 9x5 1800 1840 1760 340x5 33,8
68 8x6 2010 2050 1975 320x6 37,2
69 9x6 2160 2200 2120 340x6 40,2
78 8x7 2345 2385 2310 320x7 43,2
79 9x7 2520 2560 2480 340x7 46,7
88 8x8 2680 2720 2645 320x8 49,3
89 9x8 2880 2920 2840 340x8 53,2
Tab. RBF
Rev.2 Specifications and design can be subject to change without notice 1.22
DS DIESSE FLUID CONTROL

Product origin
Design & Manufacturing

TRASPARENT level gauges ITALY

In this kind of level gauge, the fluid is held between two smooth glasses. The level can be identified as the fluid has a different level of transparency
compared to gases and steam.

The transparent level gauge is particularly recommended for applications where the glass needs to be protected from corrosive fluids and high
temperatures. A lamp can also be fitted behind the gauge to improve visibility in special operating conditions.

With natural light With artificial light (illumination lamp)

The product line includes level gauges suitable for pressure ratings from PN10 to PN250 and a huge number of industrial process applications.

This type of gauge is recommended:


q for use with corrosive fluids (protective shield for the glass is required)
q for steam with an operating pressure > 20 bar (protective shield for the glass is required)
q if repeated thermal shocks are likely (protective shield for the glass is required)
q for checking the interface (level of separation between two immiscible fluids)
q for checking the colour of a fluid
q for dirty / oily fluids

Operating limits / Conditions:


Process:
Max. pressure: 255,5 bar @ 38°C (rating class 1500)
Max. temperature: 300°C (max. temperature allowed by borosilicate glasses as per the DIN 7081 standard - see page 1.69)

Steam: (see page 1.59)


Max. pressure: 70 bar
Max. temperature: 280°C

Types:

PN25/40 PN40/64 PN64/100 PN100/160 PN250


Class 150/300 Class 300 Class 600 Class 600/900 Class 1500
DS DIESSE FLUID CONTROL

TRASPARENT level gauges

Materials / Specifications:
Connections between housing and cocks:
- with grinded pipes and stuffing box (View can be turned can be positioned by the customer during installation)
- fixed centre-to-centre distance with metal seal (View can be turned can be positioned during manufacture)
Wetted parts:
- standard: galvanized ASTM A105 or A105 LF2 carbon steel, ASTM A182 F316L stainless steel
- additional options: on request
Non-wetted parts:
- standard: galvanized carbon steel, AISI 316/316L stainless steel
- additional options: on request
Gaskets: (See page 1.71)
- standard: graphite/copper (ASTM A105), graphite/AISI 316 (A105 LF2 and ASTM A182 F316L)
- additional options: PTFE/AISI 316; other extras on request
Glasses: (See page 1.69)
- transparent borosilicate glasses, thermally pre-stressed and extra hard as per the DIN 7081 standard
Shut-off: (See page 1.49)
- standard: upper valve and lower valve (side/side)
- additional options: on request
Drain: (See page 1.50)
- standard: threaded valve
- additional options: on request
Vent: (See page 1.50)
- standard: blind (for grinded pipes version)
- threaded with plug (for fixed distance version)
- additional options: on request

Tank connections:
Flanged:
- UNI standard: PN40 DN15 / DN20 / DN25
- ANSI standard: #150 / #300 / #600 DN ½” / ¾” / 1”
- additional options: on request
Threaded:
- BSP (GAS) standard: ½”-M / ¾”-M
- NPT standard: ½”-M / ¾”-M
Weld-on: from ½” to 1” BW or SW
Option: further connections type or direct connections to the process without shut-off cocks (See page 1.49 for more details)

Shut-off cocks, drain cock and vent cock:


- Cylindrical plug cocks (GR18 or DS MT18 - see page 1.47)
- Globe valves (DS SHV - see page 1.48)
- Push-button valves (DS NPV - see page 1.48)
- Ball valves (DS SBB)

Spare parts:
Our spare parts are interchangeable with those of major international manufacturers.
For the full range of complete sets, turn to the spares section on page 1.69.

Accessories:
Mica or PCTFE protective shield for the glass, flameproof and watertight illumination lamp (ATEX approved), lower and/or upper safety ball, pusher for
safety ball, calibrated scale, non-frosting extension, minimum level arrow, continuous reading, cocks handles lock (See page 1.55 for details)

Certifications (On request):


- ATEX
- Tests and inspection by Notified Bodies
- NACE MR0175
- Others on request

All DIESSE products are individually checked and tested in accordance with company quality procedures and the industry regulations currently in
effect.
Certificates can be issued on request.
Technical data

Service conditions
Max Pressure: PN25 e PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase
TRANSPARENT TYPE Note: depending on operating conditions, each element may have one or more internal
PN25 and PN40 reinforcements

Distance (Centre-to-centre)
DS LG - TCR GR18 Standard: see below table (Distance adjustable - 0 mm / + 10 mm)
Option: On request intermediate distances and over 3.000 mm

Materials (Standard)
Code: DS LG-TCR…-… /40/RF-GR18/…/…-M…-CS/CS Execution: CS/CS SS/CS SS/SS
Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.49)
Vent: Standard: blind Option: see page 1.50
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.50

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TCR: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS TCR: see from page 1.69 (Drawing with components and parts list see page 1.64)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+105 M = B+130 VL x No. elements

11 1x1 130 235 260 95 115x1 3,2


12 2x1 155 260 285 120 140x1 3,8
13 3x1 180 285 310 145 165x1 4,3
14 4x1 205 310 335 170 190x1 4,7
15 5x1 235 340 365 200 220x1 5,5
16 6x1 265 370 395 230 250x1 6,0
17 7x1 295 400 425 260 280x1 6,7
18 8x1 335 440 465 300 320x1 7,4
19 9x1 360 465 490 320 340x1 8,1
24 4x2 410 515 540 375 190x2 9,2
25 5x2 470 575 600 435 220x2 10,8
26 6x2 530 635 660 495 250x2 11,8
27 7x2 590 695 720 555 280x2 13,3
28 8x2 670 775 800 635 320x2 14,6
29 9x2 720 825 850 680 340x2 16,0
36 6x3 795 900 925 760 250x3 17,7
37 7x3 885 990 1015 850 280x3 19,8
38 8x3 1005 1110 1145 970 320x3 21,9
39 9x3 1080 1185 1210 1040 340x3 24,0
47 7x4 1180 1285 1310 1145 280x4 26,3
48 8x4 1340 1445 1470 1305 320x4 29,1
49 9x4 1440 1545 1570 1400 340x4 31,9
57 7x5 1475 1580 1605 1440 280x5 32,8
58 8x5 1675 1780 1805 1640 320x5 36,3
59 9x5 1800 1905 1930 1760 340x5 39,8
68 8x6 2010 2115 2140 1975 320x6 43,6
69 9x6 2160 2265 2290 2120 340x6 47,8
78 8x7 2345 2450 2475 2310 320x7 50,8
79 9x7 2520 2625 2650 2480 340x7 55,7
88 8x8 2680 2785 2810 2645 320x8 57,9
89 9x8 2880 2985 3010 2840 340x8 63,5
Tab. TCR

Rev.2 Specifications and design can be subject to change without notice 1.25
Technical data

Service conditions
Max Pressure: PN25 e PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase
TRANSPARENT TYPE Note: depending on operating conditions, each element may have one or more internal
PN25 and PN40 reinforcements

Distance (Centre-to-centre)
DS LG - TCR SHV Standard: see below table (Distance adjustable - 0 mm / + 10 mm)
Option: On request intermediate distances and over 3.000 mm

Materials (Standard)
Code: DS LG-TCR…-… /40/RF-SHV/…/…-M…-CS/CS Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: blind Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TCR: see below table
Valves DS SHV: Kg. 11,8 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS TCR: see from page 1.69 (Drawing with components and parts list see page 1.64)
Valves DS GR18: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+105 M = B+130 VL x No. elements

11 1x1 130 235 260 95 115x1 3,2


12 2x1 155 260 285 120 140x1 3,8
13 3x1 180 285 310 145 165x1 4,3
14 4x1 205 310 335 170 190x1 4,7
15 5x1 235 340 365 200 220x1 5,5
16 6x1 265 370 395 230 250x1 6,0
17 7x1 295 400 425 260 280x1 6,7
18 8x1 335 440 465 300 320x1 7,4
19 9x1 360 465 490 320 340x1 8,1
24 4x2 410 515 540 375 190x2 9,2
25 5x2 470 575 600 435 220x2 10,8
26 6x2 530 635 660 495 250x2 11,8
27 7x2 590 695 720 555 280x2 13,3
28 8x2 670 775 800 635 320x2 14,6
29 9x2 720 825 850 680 340x2 16,0
36 6x3 795 900 925 760 250x3 17,7
37 7x3 885 990 1015 850 280x3 19,8
38 8x3 1005 1110 1145 970 320x3 21,9
39 9x3 1080 1185 1210 1040 340x3 24,0
47 7x4 1180 1285 1310 1145 280x4 26,3
48 8x4 1340 1445 1470 1305 320x4 29,1
49 9x4 1440 1545 1570 1400 340x4 31,9
57 7x5 1475 1580 1605 1440 280x5 32,8
58 8x5 1675 1780 1805 1640 320x5 36,3
59 9x5 1800 1905 1930 1760 340x5 39,8
68 8x6 2010 2115 2140 1975 320x6 43,6
69 9x6 2160 2265 2290 2120 340x6 47,8
78 8x7 2345 2450 2475 2310 320x7 50,8
79 9x7 2520 2625 2650 2480 340x7 55,7
88 8x8 2680 2785 2810 2645 320x8 57,9
89 9x8 2880 2985 3010 2840 340x8 63,5
Tab. TCR
Rev.2 Specifications and design can be subject to change without notice 1.26
Technical data

Service conditions
Max Pressure: PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase
TRANSPARENT TYPE
PN40 Distance (Centre-to-centre)
Standard: see below table (Distance adjustable - 0 mm / + 10 mm)
Option: On request intermediate distances and over 3.000 mm
DS LG - TMR GR18
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Code: DS LG-TMR…-… /40/RF-GR18/…/…-M…-CS/CS Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.49)
Vent: Standard: blind Option: see page 1.50
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.50

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69) Option: type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TMR: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS TMR: see from page 1.69 (Drawing with components and parts list see page 1.64)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+105 M = B+130 VL x No. elements

11 1x1 130 235 260 95 115x1 3,6


12 2x1 155 260 285 120 140x1 4,3
13 3x1 180 285 310 145 165x1 4,9
14 4x1 205 310 335 170 190x1 5,4
15 5x1 235 340 365 200 220x1 6,3
16 6x1 265 370 395 230 250x1 6,9
17 7x1 295 400 425 260 280x1 7,7
18 8x1 335 440 465 300 320x1 8,6
19 9x1 360 465 490 320 340x1 9,4
24 4x2 410 515 540 375 190x2 10,6
25 5x2 470 575 600 435 220x2 12,4
26 6x2 530 635 660 495 250x2 13,6
27 7x2 590 695 720 555 280x2 15,2
28 8x2 670 775 800 635 320x2 17,0
29 9x2 720 825 850 680 340x2 18,6
36 6x3 795 900 925 760 250x3 20,3
37 7x3 885 990 1015 850 280x3 22,7
38 8x3 1005 1110 1145 970 320x3 25,4
39 9x3 1080 1185 1210 1040 340x3 27,8
47 7x4 1180 1285 1310 1145 280x4 30,2
48 8x4 1340 1445 1470 1305 320x4 33,8
49 9x4 1440 1545 1570 1400 340x4 37,0
57 7x5 1475 1580 1605 1440 280x5 37,7
58 8x5 1675 1780 1805 1640 320x5 42,2
59 9x5 1800 1905 1930 1760 340x5 46,2
68 8x6 2010 2115 2140 1975 320x6 50,6
69 9x6 2160 2265 2290 2120 340x6 55,4
78 8x7 2345 2450 2475 2310 320x7 59,0
79 9x7 2520 2625 2650 2480 340x7 64,6
88 8x8 2680 2785 2810 2645 320x8 67,4
89 9x8 2880 2985 3010 2840 340x8 73,8
Tab. TMR

Rev.2 Specifications and design can be subject to change without notice 1.27
Technical data

Service conditions
Max Pressure: PN40
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase
TRANSPARENT TYPE
PN40 Distance (Centre-to-centre)
Standard: see below table (Distance adjustable - 0 mm / + 10 mm)
Option: On request intermediate distances and over 3.000 mm
DS LG - TMR SHV
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Code: DS LG-TMR…-… /40/RF-SHV/…/…-M…-CS/CS Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: blind Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69) Option: type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TMR: see below table
Valves DS SHV: Kg. 11,8 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS TMR: see from page 1.69 (Drawing with components and parts list see page 1.64)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE SL DISTANCE HL VISIBLE GLASS WEIGHT


Length Pipes L = 57 Pipes L = 70 Length Length Housing
[mm] M [-0/+10 mm] M [-0/+10 mm] [mm] [mm] [Kg]

x No. el. B M = B+105 M = B+130 VL x No. elements

11 1x1 130 235 260 95 115x1 3,6


12 2x1 155 260 285 120 140x1 4,3
13 3x1 180 285 310 145 165x1 4,9
14 4x1 205 310 335 170 190x1 5,4
15 5x1 235 340 365 200 220x1 6,3
16 6x1 265 370 395 230 250x1 6,9
17 7x1 295 400 425 260 280x1 7,7
18 8x1 335 440 465 300 320x1 8,6
19 9x1 360 465 490 320 340x1 9,4
24 4x2 410 515 540 375 190x2 10,6
25 5x2 470 575 600 435 220x2 12,4
26 6x2 530 635 660 495 250x2 13,6
27 7x2 590 695 720 555 280x2 15,2
28 8x2 670 775 800 635 320x2 17,0
29 9x2 720 825 850 680 340x2 18,6
36 6x3 795 900 925 760 250x3 20,3
37 7x3 885 990 1015 850 280x3 22,7
38 8x3 1005 1110 1145 970 320x3 25,4
39 9x3 1080 1185 1210 1040 340x3 27,8
47 7x4 1180 1285 1310 1145 280x4 30,2
48 8x4 1340 1445 1470 1305 320x4 33,8
49 9x4 1440 1545 1570 1400 340x4 37,0
57 7x5 1475 1580 1605 1440 280x5 37,7
58 8x5 1675 1780 1805 1640 320x5 42,2
59 9x5 1800 1905 1930 1760 340x5 46,2
68 8x6 2010 2115 2140 1975 320x6 50,6
69 9x6 2160 2265 2290 2120 340x6 55,4
78 8x7 2345 2450 2475 2310 320x7 59,0
79 9x7 2520 2625 2650 2480 340x7 64,6
88 8x8 2680 2785 2810 2645 320x8 67,4
89 9x8 2880 2985 3010 2840 340x8 73,8
Tab. TMR

Rev.2 Specifications and design can be subject to change without notice 1.28
Technical data

Service conditions
Max Pressure: PN40; Class 300 (A105: 51 bar @ 38°C; AISI 316L: 49,6 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
TRANSPARENT TYPE Note: depending on operating conditions, each element may have one or more internal
PN40 / Class 300 reinforcements

Distance (Centre-to-centre)
DS LG - TCF GR18 Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm

Materials (Standard)
Code: DS LG-TCF…-… /40/RF-GR18/…/…-M…-CS/CS Execution: CS/CS SS/CS SS/SS
Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TCF: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS TCF: see from page 1.69 (Drawing with components and parts list see page 1.64)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+40 VL x No. elements

11 1x1 130 170 95 115x1 4,5


12 2x1 155 195 120 140x1 5,1
13 3x1 180 220 145 165x1 5,6
14 4x1 205 245 170 190x1 6,0
15 5x1 235 275 200 220x1 6,8
16 6x1 265 305 230 250x1 7,3
17 7x1 295 335 260 280x1 8,0
18 8x1 335 375 300 320x1 8,7
19 9x1 360 400 320 340x1 9,4
24 4x2 410 450 375 190x2 10,5
25 5x2 470 510 435 220x2 12,1
26 6x2 530 570 495 250x2 13,1
27 7x2 590 630 555 280x2 14,6
28 8x2 670 710 635 320x2 15,9
29 9x2 720 760 680 340x2 17,3
36 6x3 795 835 760 250x3 19,0
37 7x3 885 925 850 280x3 21,1
38 8x3 1005 1045 970 320x3 23,2
39 9x3 1080 1120 1040 340x3 25,3
47 7x4 1180 1220 1145 280x4 27,6
48 8x4 1340 1380 1305 320x4 30,4
49 9x4 1440 1480 1400 340x4 33,2
57 7x5 1475 1515 1440 280x5 34,1
58 8x5 1675 1715 1640 320x5 37,6
59 9x5 1800 1840 1760 340x5 41,1
68 8x6 2010 2050 1975 320x6 44,9
69 9x6 2160 2200 2120 340x6 49,1
78 8x7 2345 2385 2310 320x7 52,1
79 9x7 2520 2560 2480 340x7 57,0
88 8x8 2680 2720 2645 320x8 59,2
89 9x8 2880 2920 2840 340x8 64,8
Tab. TCF

Rev.2 Specifications and design can be subject to change without notice 1.29
Technical data

Service conditions
Max Pressure: PN40; Class 300 (A105: 51 bar @ 38°C; AISI 316L: 49,6 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
TRANSPARENT TYPE Note: depending on operating conditions, each element may have one or more internal
PN40 / Class 300 reinforcements

Distance (Centre-to-centre)
DS LG - TCF SHV Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm

Materials (Standard)
Code: DS LG-TCF…-… /40/RF-SHV/…/…-M…-CS/CS Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN40 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TCF: see below table
Valves DS SHV: Kg. 11,8 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS TCF: see from page 1.69 (Drawing with components and parts list see page 1.64)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 4,5


12 2x1 155 235 120 140x1 5,1
13 3x1 180 260 145 165x1 5,6
14 4x1 205 285 170 190x1 6,0
15 5x1 235 315 200 220x1 6,8
16 6x1 265 345 230 250x1 7,3
17 7x1 295 375 260 280x1 8,0
18 8x1 335 415 300 320x1 8,7
19 9x1 360 440 320 340x1 9,4
24 4x2 410 490 375 190x2 10,5
25 5x2 470 550 435 220x2 12,1
26 6x2 530 610 495 250x2 13,1
27 7x2 590 670 555 280x2 14,6
28 8x2 670 750 635 320x2 15,9
29 9x2 720 800 680 340x2 17,3
36 6x3 795 875 760 250x3 19,0
37 7x3 885 965 850 280x3 21,1
38 8x3 1005 1085 970 320x3 23,2
39 9x3 1080 1160 1040 340x3 25,3
47 7x4 1180 1260 1145 280x4 27,6
48 8x4 1340 1420 1305 320x4 30,4
49 9x4 1440 1520 1400 340x4 33,2
57 7x5 1475 1555 1440 280x5 34,1
58 8x5 1675 1755 1640 320x5 37,6
59 9x5 1800 1880 1760 340x5 41,1
68 8x6 2010 2090 1975 320x6 44,9
69 9x6 2160 2240 2120 340x6 49,1
78 8x7 2345 2425 2310 320x7 52,1
79 9x7 2520 2600 2480 340x7 57,0
88 8x8 2680 2760 2645 320x8 59,2
89 9x8 2880 2960 2840 340x8 64,8
Tab. TCF
Rev.2 Specifications and design can be subject to change without notice 1.30
Technical data

Service conditions
Max Pressure: PN40 e PN64; Class 300 (A105: 51 bar @ 38°C; AISI 316L: 49,6 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
TRANSPARENT TYPE
PN40 and PN64 / Class 300 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm
DS LG - TMF GR18
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Code: DS LG-TMF…-… /40/RF-GR18/…/…-M…-CS/CS Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN40-64 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69) Option: type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TMF: see below table
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS TMF: see from page 1.69 (Drawing with components and parts list see page 1.64)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+40 VL x No. elements

11 1x1 130 170 95 115x1 5,4


12 2x1 155 195 120 140x1 6,1
13 3x1 180 220 145 165x1 6,7
14 4x1 205 245 170 190x1 7,2
15 5x1 235 275 200 220x1 8,1
16 6x1 265 305 230 250x1 8,8
17 7x1 295 335 260 280x1 9,5
18 8x1 335 375 300 320x1 10,4
19 9x1 360 400 320 340x1 11,2
24 4x2 410 450 375 190x2 12,4
25 5x2 470 510 435 220x2 14,2
26 6x2 530 570 495 250x2 15,4
27 7x2 590 630 555 280x2 17,0
28 8x2 670 710 635 320x2 18,8
29 9x2 720 760 680 340x2 20,4
36 6x3 795 835 760 250x3 22,1
37 7x3 885 925 850 280x3 24,5
38 8x3 1005 1045 970 320x3 27,2
39 9x3 1080 1120 1040 340x3 29,6
47 7x4 1180 1220 1145 280x4 32,0
48 8x4 1340 1380 1305 320x4 35,6
49 9x4 1440 1480 1400 340x4 38,8
57 7x5 1475 1515 1440 280x5 39,5
58 8x5 1675 1715 1640 320x5 44,0
59 9x5 1800 1840 1760 340x5 48,0
68 8x6 2010 2050 1975 320x6 52,4
69 9x6 2160 2200 2120 340x6 57,2
78 8x7 2345 2385 2310 320x7 60,8
79 9x7 2520 2560 2480 340x7 66,4
88 8x8 2680 2720 2645 320x8 69,2
89 9x8 2880 2920 2840 340x8 75,6
Tab. TMF

Rev.2 Specifications and design can be subject to change without notice 1.31
Technical data

Service conditions
Max Pressure: PN40 e PN64; Class 300 (A105: 51 bar @ 38°C; AISI 316L: 49,6 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
TRANSPARENT TYPE
PN40 and PN64 / Class 300 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 3.000 mm
DS LG - TMF SHV
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Code: DS LG-TMF…-… /40/RF-SHV/…/…-M…-CS/CS Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN40-64 DN15-20-25 ANSI #150-300/RF DN ½“ - ¾“ - 1“
Standard threaded unions: GAS-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69) Option: type A (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TMF: see below table
Valves DS SHV: Kg. 11,8 approx. (With flanges UNI DN20 PN40)

Tightening torque of housing screws


Standard: 35 Nm

Spare parts
Housing DS TMF: see from page 1.69 (Drawing with components and parts list see page 1.64)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 5,4


12 2x1 155 235 120 140x1 6,1
13 3x1 180 260 145 165x1 6,7
14 4x1 205 285 170 190x1 7,2
15 5x1 235 315 200 220x1 8,1
16 6x1 265 345 230 250x1 8,8
17 7x1 295 375 260 280x1 9,5
18 8x1 335 415 300 320x1 10,4
19 9x1 360 440 320 340x1 11,2
24 4x2 410 490 375 190x2 12,4
25 5x2 470 550 435 220x2 14,2
26 6x2 530 610 495 250x2 15,4
27 7x2 590 670 555 280x2 17,0
28 8x2 670 750 635 320x2 18,8
29 9x2 720 800 680 340x2 20,4
36 6x3 795 875 760 250x3 22,1
37 7x3 885 965 850 280x3 24,5
38 8x3 1005 1085 970 320x3 27,2
39 9x3 1080 1160 1040 340x3 29,6
47 7x4 1180 1260 1145 280x4 32,0
48 8x4 1340 1420 1305 320x4 35,6
49 9x4 1440 1520 1400 340x4 38,8
57 7x5 1475 1555 1440 280x5 39,5
58 8x5 1675 1755 1640 320x5 44,0
59 9x5 1800 1880 1760 340x5 48,0
68 8x6 2010 2090 1975 320x6 52,4
69 9x6 2160 2240 2120 340x6 57,2
78 8x7 2345 2425 2310 320x7 60,8
79 9x7 2520 2600 2480 340x7 66,4
88 8x8 2680 2760 2645 320x8 69,2
89 9x8 2880 2960 2840 340x8 75,6
Tab. TMF

Rev.2 Specifications and design can be subject to change without notice 1.32
Technical data

Service conditions
Max Pressure: PN64 e PN100; Class 600 (A105: 102 bar @ 38°C; AISI 316L: 99,3 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
TRANSPARENT TYPE Note: depending on operating conditions, each element may have one or more internal
PN64 and PN100 / Class 600 reinforcements

Distance (Centre-to-centre)
DS LG - TPF GR18 Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 2.000 mm

Materials (Standard)
Code: DS LG-TPF…-… /100/RF-GR18/…/…-M…-CS/CS Execution: CS/CS SS/CS SS/SS
Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN64-100 DN20 - DN25 ANSI #600/RF DN ¾“ - 1“
Standard threaded unions: BSP-M ¾” - 1” NPT-M ¾” - 1”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TPF: see below table
Cocks DS GR18: Kg. 9,2 approx. (With flanges UNI DN20 PN100)

Tightening torque of housing screws


Standard: 75 Nm

Spare parts
Housing DS TPF: see from page 1.69 (Drawing with components and parts list see page 1.65)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+50 VL x No. elements

11 1x1 130 180 95 115x1 7,9


12 2x1 155 205 120 140x1 9,0
13 3x1 180 230 145 165x1 10,5
14 4x1 205 255 170 190x1 11,5
15 5x1 235 285 200 220x1 12,8
16 6x1 265 315 230 250x1 13,5
17 7x1 295 345 260 280x1 15,4
18 8x1 335 385 300 320x1 16,8
19 9x1 360 410 320 340x1 18,1
24 4x2 410 460 375 190x2 21,5
25 5x2 470 520 435 220x2 24,1
26 6x2 530 580 495 250x2 25,5
27 7x2 590 640 555 280x2 29,3
28 8x2 670 720 635 320x2 32,1
29 9x2 720 770 680 340x2 34,7
36 6x3 795 845 760 250x3 37,5
37 7x3 885 935 850 280x3 43,2
38 8x3 1005 1055 970 320x3 47,4
39 9x3 1080 1130 1040 340x3 51,3
47 7x4 1180 1230 1145 280x4 57,1
48 8x4 1340 1390 1305 320x4 62,7
49 9x4 1440 1490 1400 340x4 67,9
57 7x5 1475 1525 1440 280x5 71,0
58 8x5 1675 1725 1640 320x5 78,0
59 9x5 1800 1850 1760 340x5 84,5
Tab. TPF

Rev.2 Specifications and design can be subject to change without notice 1.33
Technical data

Service conditions
Max Pressure: PN64 e PN100; Class 600 (A105: 102 bar @ 38°C; AISI 316L: 99,3 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
TRANSPARENT TYPE Note: depending on operating conditions, each element may have one or more internal
PN64 and PN100 / Class 600 reinforcements

Distance (Centre-to-centre)
DS LG - TPF SHV Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 2.000 mm

Materials (Standard)
Code: DS LG-TPF…-… /100/RF-GR18/…/…-M…-CS/CS Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN64-100 DN15-20-25 ANSI #600/RF DN ¾“ - 1“
Standard threaded unions: BSP-M ¾” - 1” NPT-M ¾” - 1”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: valve DS DHV threaded ¾” Option: see page 1.54

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TPF: see below table
Valves DS DS SHV: Kg. 13,5 approx. (With flanges UNI DN20 PN100)

Tightening torque of housing screws


Standard: 75 Nm

Spare parts
Housing DS TPF: see from page 1.69 (Drawing with components and parts list see page 1.65)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 7,9


12 2x1 155 235 120 140x1 9,0
13 3x1 180 260 145 165x1 10,5
14 4x1 205 285 170 190x1 11,5
15 5x1 235 315 200 220x1 12,8
16 6x1 265 345 230 250x1 13,5
17 7x1 295 375 260 280x1 15,4
18 8x1 335 415 300 320x1 16,8
19 9x1 360 440 320 340x1 18,1
24 4x2 410 490 375 190x2 21,5
25 5x2 470 550 435 220x2 24,1
26 6x2 530 610 495 250x2 25,5
27 7x2 590 670 555 280x2 29,3
28 8x2 670 750 635 320x2 32,1
29 9x2 720 800 680 340x2 34,7
36 6x3 795 875 760 250x3 37,5
37 7x3 885 965 850 280x3 43,2
38 8x3 1005 1085 970 320x3 47,4
39 9x3 1080 1160 1040 340x3 51,3
47 7x4 1180 1260 1145 280x4 57,1
48 8x4 1340 1420 1305 320x4 62,7
49 9x4 1440 1520 1400 340x4 67,9
57 7x5 1475 1555 1440 280x5 71,0
58 8x5 1675 1755 1640 320x5 78,0
59 9x5 1800 1880 1760 340x5 84,5
Tab. TPF

Rev.2 Specifications and design can be subject to change without notice 1.34
Technical data

Service conditions
Max Pressure: PN100; Class 600 (A105: 102 bar @ 38°C; AISI 316L: 99,3 bar @ 38°C) and
PN160; Class 900 (A105: 153,1 bar @ 38°C; AISI 316L: 148,9 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)
GLASS LEVEL GAUGE
View
TRANSPARENT TYPE Standard: front, on request lateral (right or left) adjustable in the production phase
PN100 and PN160 / Class 600 and 900
Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
DS LG - TXF GR18 Option: On request intermediate distances and over 2.000 mm

Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Code: DS LG-TXF…-… /160/RF-GR18/…/…-M…-CS/CS Gauge body & cocks body: ASTM A105 AISI 316L AISI 316L
Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)
Process connections:
Standard flanges: UNI PN100-160 DN20 - DN25 ANSI #600-900/RF DN ¾“ - 1“
Standard threaded unions: BSP-M ¾” - 1” NPT-M ¾” - 1”
Options: further connections types or direct connections to the process without shut-off cocks
(See page 1.51)
Vent: Standard: threaded ½” with plug Option: see page 1.52
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.52

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TXF: see below table
Cocks DS GR18: Kg. 9,2 approx. (With flanges UNI DN20 PN100)

Tightening torque of housing screws


Standard: 75 Nm

Spare parts
Housing DS TXF: see from page 1.69 (Drawing with components and parts list see page 1.65)
Cocks DS GR18: see from page 1.72 (Drawing with components and parts list see page 1.66)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+50 VL x No. elements

11 1x1 130 180 95 115x1 11,6


12 2x1 155 205 120 140x1 13,2
13 3x1 180 230 145 165x1 15,1
14 4x1 205 255 170 190x1 16,5
15 5x1 235 285 200 220x1 18,3
16 6x1 265 315 230 250x1 19,5
17 7x1 295 345 260 280x1 22,0
18 8x1 335 385 300 320x1 24,1
19 9x1 360 410 320 340x1 25,8
24 4x2 410 460 375 190x2 30,0
25 5x2 470 520 435 220x2 33,6
26 6x2 530 580 495 250x2 36,0
27 7x2 590 640 555 280x2 41,0
28 8x2 670 720 635 320x2 45,2
29 9x2 720 770 680 340x2 48,6
36 6x3 795 845 760 250x3 52,5
37 7x3 885 935 850 280x3 60,0
38 8x3 1005 1055 970 320x3 66,3
39 9x3 1080 1130 1040 340x3 71,4
47 7x4 1180 1230 1145 280x4 79,0
48 8x4 1340 1390 1305 320x4 87,4
49 9x4 1440 1490 1400 340x4 94,2
57 7x5 1475 1525 1440 280x5 98,0
58 8x5 1675 1725 1640 320x5 108,5
59 9x5 1800 1850 1760 340x5 117,0
Tab. TXF

Rev.2 Specifications and design can be subject to change without notice 1.35
Technical data

Service conditions
Max Pressure: PN100; Class 600 (A105: 102 bar @ 38°C; AISI 316L: 99,3 bar @ 38°C) and
PN160; Class 900 (A105: 153,1 bar @ 38°C; AISI 316L: 148,9 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)
GLASS LEVEL GAUGE
View
TRANSPARENT TYPE Standard: front, on request lateral (right or left) adjustable in the production phase
PN100 and PN160 / Class 600 and 900
Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
DS LG - TXF SHV Option: On request intermediate distances and over 2.000 mm

Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Code: DS LG-TXF…-… /160/RF-SHV/…/…-M…-CS/CS Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/copper Option: graphite/AISI 316 or PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN100-160 DN20-25 ANSI #600-900/RF DN ¾“ - 1“
Standard threaded unions: BSP-M ¾” - 1” NPT-M ¾” - 1”
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: cock DS DHV threaded ¾” Option: see page 1.54

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TXF: see below table
Valves DS SHV: Kg. 13,5 approx. (With flanges UNI DN20 PN100)

Tightening torque of housing screws


Standard: 75 Nm

Spare parts
Housing DS TXF: see from page 1.69 (Drawing with components and parts list see page 1.65)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 11,6


12 2x1 155 235 120 140x1 13,2
13 3x1 180 260 145 165x1 15,1
14 4x1 205 285 170 190x1 16,5
15 5x1 235 315 200 220x1 18,3
16 6x1 265 345 230 250x1 19,5
17 7x1 295 375 260 280x1 22,0
18 8x1 335 415 300 320x1 24,1
19 9x1 360 440 320 340x1 25,8
24 4x2 410 490 375 190x2 30,0
25 5x2 470 550 435 220x2 33,6
26 6x2 530 610 495 250x2 36,0
27 7x2 590 670 555 280x2 41,0
28 8x2 670 750 635 320x2 45,2
29 9x2 720 800 680 340x2 48,6
36 6x3 795 875 760 250x3 52,5
37 7x3 885 965 850 280x3 60,0
38 8x3 1005 1085 970 320x3 66,3
39 9x3 1080 1160 1040 340x3 71,4
47 7x4 1180 1260 1145 280x4 79,0
48 8x4 1340 1420 1305 320x4 87,4
49 9x4 1440 1520 1400 340x4 94,2
57 7x5 1475 1555 1440 280x5 98,0
58 8x5 1675 1755 1640 320x5 108,5
59 9x5 1800 1880 1760 340x5 117,0
Tab. TXF

Rev.2 Specifications and design can be subject to change without notice 1.36
Technical data

Service conditions
Max Pressure: PN250; Class 1500 (A105: 255,5 bar @ 38°C; AISI 316L: 239,2 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)

GLASS LEVEL GAUGE View


Standard: front, on request lateral (right or left) adjustable in the production phase
TRANSPARENT TYPE
PN250 / Class 1500 Distance (Centre-to-centre)
Standard: see below table for minimum distance (Fixed distance, not adjustable)
Option: On request intermediate distances and over 2.000 mm
DS LG - TEF SHV
Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Gauge body: ASTM A105 / A105 LF2 AISI 316L AISI 316L
Code: DS LG-TEF…-… /1500/…-SHV/…/…-M…-CS/CS Valves body: A105 LF2 AISI 316L AISI 316L
Stem, disc / seat valves: AISI 410 / AISI 316 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite/AISI 316 Option: PTFE/AISI316

Shut-off valves
DS SHV: globe type
Handling: by handwheel
Process connections:
Standard flanges: UNI PN250 DN On request ANSI #1500 DN On request
Options: further connections types or direct connections to the process without shut-off valves
(See page 1.53)
Vent: Standard: threaded ½” with plug Option: see page 1.54
Drain: Standard: cock DS DHV threaded ¾” Option: see page 1.54

Glasses
Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to DIN 7081
Standard: fitted with type B, thickness 21 mm (See page 1.69)

Accessories
See from page 1.55

Weights
Housing DS TEF: see below table
Valves DS SHV: Kg. 16,5 approx. (With flanges 1” ANSI 1500#RF)

Tightening torque of housing screws


Standard: 90 Nm

Spare parts
Housing DS TEF: see from page 1.69 (Drawing with components and parts list see page 1.65)
Valves DS SHV: see from page 1.74 (Drawing with components and parts list see page 1.68)

CODE TYPE BODY DISTANCE VISIBLE GLASS WEIGHT


Length MINIMUM SL Length Length Housing
[mm] [mm] [mm] [mm] [Kg]

x No. el. B M = B+80 VL x No. elements

11 1x1 130 210 95 115x1 13,7


12 2x1 155 235 120 140x1 15,7
13 3x1 180 260 145 165x1 18,0
14 4x1 205 285 170 190x1 19,8
15 5x1 235 315 200 220x1 22,1
16 6x1 265 345 230 250x1 23,8
17 7x1 295 375 260 280x1 26,7
18 8x1 335 415 300 320x1 29,5
19 9x1 360 440 320 340x1 31,6
24 4x2 410 490 375 190x2 36,6
25 5x2 470 550 435 220x2 41,1
26 6x2 530 610 495 250x2 44,5
27 7x2 590 670 555 280x2 50,5
28 8x2 670 750 635 320x2 55,9
29 9x2 720 800 680 340x2 60,1
36 6x3 795 875 760 250x3 65,2
37 7x3 885 965 850 280x3 74,2
38 8x3 1005 1085 970 320x3 82,4
39 9x3 1080 1160 1040 340x3 88,7
47 7x4 1180 1260 1145 280x4 97,9
48 8x4 1340 1420 1305 320x4 108,9
49 9x4 1440 1520 1400 340x4 117,3
57 7x5 1475 1555 1440 280x5 121,6
58 8x5 1675 1755 1640 320x5 135,5
59 9x5 1800 1880 1760 340x5 145,8
Tab. TEF

Rev.2 Specifications and design can be subject to change without notice 1.36.1
DS DIESSE FLUID CONTROL

Product origin
Design & Manufacturing

weld-on level gauges ITALY

This type of level gauge is designed to be welded on to the tank and withstand the pressure inside it.

It is made from both carbon steel and stainless steel and can take reflex and transparent glasses.
Reflex glasses are recommended as they improve visibility.

In order to prevent warping or distortions while the level gauge is in service, the technician tasked with installing the product must
reinforce the wall of the tank where the gauge is to be welded on.

For visible lengths exceeding 320 mm, we recommend welding additional gauges on different axes to avoid weakening the tank
structure.

During welding operations (which must only be carried out prior to gauge assembly), special care must be taken to avoid exposing
the weld-on base to high temperatures for long periods of time as this may comprise the resistance of the gauge when in operation.

Operating limits / Conditions:

Process:
Max. pressure: rating class 300 (A105: 51 bar; AISI 316L :
49,6 bar) @ 38°C

Max. temperature: 300°C (max. temperature allowed by


borosilicate glasses as per the DIN 7081
standard - see page 1.69)

On request: rating class 600 (A105: 102 bar; AISI 316L :


99,3 bar) @ 38°C
Materials / Specifications

Weld-on base:
- standard: flat with a hole running along the whole visible length
- additional options: with radius (state the tank radius); with 2 holes (Ø: 15 mm)
at the far ends of the visible length

Wetted parts:
- standard: galvanized ASTM A105 or A105 LF2 carbon steel,
ASTM A182 F316L stainless steel
- additional options: on request

Non-wetted parts:
- standard: galvanized carbon steel, AISI 316L stainless steel
- additional options: on request

Gaskets: (see page 1.71)


- standard: graphite
- additional options: PTFE; other extras on request

Glasses: (see page 1.69)


- reflex or transparent borosilicate glasses, thermally pre-stressed and
extra hard as per the DIN 7081 standard

Spare parts:
Our spare parts are interchangeable with those of major international manufacturers.
For the full range of complete sets, turn to the spares section on page 1.69.

Accessories:
Mica or PCTFE protective shield (for transparent glass only), calibrated scale, non-frosting extension, minimum
level arrow (see page 1.55 for details)

Certifications (on request):


- NACE MR0175
- Others on request

This kind of level gauge can only be tested once it has been
welded on to the tank in question.
All DIESSE components are individually checked and tested in
accordance with company quality procedures and the
industry regulations currently in effect.
Certificates can be issued on request.
Technical data

Service conditions
Max Pressure: PN40; Class 300 (A105: 51 bar @ 38°C; AISI 316L: 49,6 bar @ 38°C)
Option: PN100; Class 600 (A105: 102 bar @ 38°C; AISI 316L: 99,3 bar @ 38°C)
Max Temperature: 300°C (According to DIN 7081 for glasses, see page 1.69)
WELD-ON GLASS LEVEL GAUGE
Total length
REFLEX and TRANSPARENT Standard: see below table
PN40 / Class 300 Option: On request intermediate lengths and over 1.080 mm

Process connections
DS LG - RCW / TCW Standard: Drilling on the whole visible length
Option: Two holes Ø 15 mm at the opposite ends of the visible length or two pipes welded at the
centre-to-centre distance requested (See below drawing)

Code: DS LG-RCW…-CS/CS REFLEX Execution of housing to be weld


Code: DS LG-TCW…-CS/CS TRANSPARENT Standard: flat
Option: On request with back radius

Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Housing body: ASTM A105 AISI 316L AISI 316L
Cover: ASTM A105 ASTM A105 AISI 316L
Bolts and nuts: Carbon steel galvanized Carbon steel galvanized AISI 316

Gaskets
Standard: graphite Option: PTFE

Glasses
Reflex and Transparent - Borosilicate glass, “extra hard” and thermally pre-stressed - According to
DIN 7081
Standard: fitted with type B (See page 1.69)
Option: type A (See page 1.69)

Accessories
See from page 1.55

Weights
See below table

Tightening torque of screws


Standard: 25-30 Nm

Spare parts
See from page 1.69

Recommendation
For requested visible lengths over 320 mm, to avoid the tank structure weakness, it is
recommended to weld on the tank more level gauges positioned on different axes

CODE TYPE BODY VISIBLE GLASS WEIGHT


Length Length Length Housing
[mm] [mm] [mm] [Kg]

x No. el. B VL x No. elements

11 1x1 130 95 115 2,5


12 2x1 155 120 140 3,0
13 3x1 180 145 165 3,4
14 4x1 205 170 190 3,9
15 5x1 235 200 220 4,7
16 6x1 265 230 250 5,1
17 7x1 295 260 280 5,6
18 8x1 335 300 320 6,0
19 9x1 360 320 340 6,9
24 4x2 410 375 190x2 7,8
25 5x2 470 435 220x2 9,4
26 6x2 530 495 250x2 10,2
27 7x2 590 555 280x2 11,2
28 8x2 670 635 320x2 12,0
Code: DS LG-RCWSP…-CS/CS REFLEX 29 9x2 720 680 340x2 13,8
Code: DS LG-TCWSP…-CS/CS TRANSPARENT 36 6x3 795 760 250x3 15,3
37 7x3 885 850 280x3 16,8
38 8x3 1005 970 320x3 18,0
39 9x3 1080 1040 340x3 20,7
Tab. RCW/TCW

Rev.2 Specifications and design can be subject to change without notice 1.38
DS DIESSE FLUID CONTROL

Product origin
Design & Manufacturing

level gauges ITALY


WITH GLASS TUBE
Level gauges with a glass tube are an inexpensive but valid option for checking the level of non-hazardous or non-reactive fluids
in unpressurised tanks.

An external metal protection of the glass tube is recommended.

Available configurations:

Borosilicate glass tube. Diameter: 16 mm; thickness:


2.5 mm.

Centre-to-centre distance with a single tube: 3000 mm.


Visible length (without protection):
centre-to-centre distance - 95 mm.
Visible length (with protection):
centre-to-centre distance - 135 mm.
Spare glass tube: centre-to-centre distance - 30 mm.
Spare protection: centre-to-centre distance - 100 mm.

In the event of greater centre-to-centre distances,


additional pipes can be connected up via middle
terminals for glass tube

Operating limits / Conditions:


Process:
Max. pressure: 5 bar @ 38°C (the max. pressure also
depends on the length and temperature)

Max. temperature: 120°C

The product is NOT suitable for use in the following


instances:
• if it is likely to be exposed to vibrations (glass tube will
break)
• if the installation is situated by a walkway (possibility of
blows/impact)
• if exposed to steam (shortens glass tube life)
Materials / Specifications

Transparent tube: grade 3.3 borosilicate glass


Glass protection (optional): AISI 304 stainless steel
Wetted parts:
- standard: galvanized ASTM A105 or A105 LF2 carbon steel, ASTM A182 F316L stainless steel
- additional options: on request
Non-wetted parts:
- standard: galvanized carbon steel, AISI 316/316L stainless steel
- additional options: on request
Gaskets: (see page 1.72)
Cocks:
- standard: graphite/copper (ASTM A105), graphite/AISI 316 (A105 LF2 and ASTM A182 F316L)
- additional options: PTFE; other extras on request
Sealing gasket:
- standard: EPDM
- additional options: graphite or PTFE; other extras on request
Shut-off: (see page 1.49)
- standard: upper valve and lower valve (side/side)
- additional options: on request
Drain: (see page 1.50)
- standard: threaded valve
- additional options: on request
Vent: (see page 1.50)
- standard: blind
- additional options: threaded with plug; other extras on request

Tank connections:
Flanged:
- UNI standard: PN40 DN15 / DN20 / DN25
- ANSI standard: #150 DN ½” / ¾” / 1”
- additional options: on request
Threaded:
- BSP (GAS) standard: ½”-M / ¾”-M
- NPT standard: ½”-M / ¾”-M
Weld-on: from ½” to 1” BW or SW
Option: further connections type or direct connections to the process without shut-off cocks
(see page 1.49 for more details)

Shut-off cocks, drain cock and vent cock:


- Cylindrical plug cocks

Spares:
Our spare parts are interchangeable with those of major international manufacturers.
For the full range of complete sets, turn to the spares section on page 1.69.

Accessories:
Stainless steel "U" protection, lower and/or upper safety ball, pusher for safety ball, calibrated, non-frosting
extension, minimum level arrow, continuous reading, cocks handles lock (see page 1.55 for details)

Certifications (on request):


--

For this kind of gauge the pressure test can be performed only
on the cocks (on request),glass tubes cannot be tested due to
their fragility. All DIESSE components are individually checked
and tested in accordance with company quality procedures
and the industry regulations currently in effect.
Certificates can be issued on request.
Technical data

Service conditions
Max Pressure: 5 barg (Max. pressure also function of the length and the temperature)
Max Temperature: 120°C

LEVEL GAUGE View


Standard: adjustable on 360° in the installation phase (Rotating the "U" shaped protection)
WITH GLASS TUBE AND
“U” SHAPED PROTECTION Distance (Centre-to-centre)
On request
Max with a single glass tube 3.000 mm
DS LG - TVR GR18 / MT18 Option: on request are available distances over 3.000 mm using the middle terminals to connect
more glass tubes

Visible length [VL]


Code: DS LG-TVR…-… /16/RF-GR18/…/…-M…-CS/CS
With shut-off cocks DS GR18

 With the “U” shaped protection


Visible length [VL] = Centre-to-centre distance [M] - 135 mm (With extended stuffing box
covers to fasten the "U"
shaped protection)

 Without protection
Visible length [VL] = Centre-to-centre distance [M] - 95 mm (With standard stuffing box covers)

With shut-off cocks DS MT18

 With the “U” shaped protection


Visible length [VL] = Centre-to-centre distance [M] - 145 mm (With extended stuffing box
covers to fasten the "U"
shaped protection)

 Without protection
Visible length [VL] = Centre-to-centre distance [M] - 105 mm (With standard stuffing box cover)

Materials (Standard)
Execution: CS/CS SS/CS SS/SS
Cocks body: ASTM A105 AISI 316L AISI 316L
Cocks trim: AISI 303 AISI 316 AISI 316
Non-wetted parts: Carbon steel galvanized Carbon steel galvanized AISI 316

Glass tube
Standard: borosilicate glass 3.3, Ø 16 mm, thickness 2,5 mm
Code: DS LG TVR…-… /16/RF-MT18/…/…-M…-CS/CS
Protection for glass tube (Option always recommended)
Standard: metal sheet "U" shaped in stainless steel AISI 304

Gaskets
Standard: Cocks: graphite/copper Glass sealing: EPDM
Option: Cocks: graphite/AISI 316 Glass sealing: graphite
Cocks: PTFE/AISI316 Glass sealing: PTFE

Shut-off cocks
DS GR18: cylindrical plug type - Straight type - Quick 90° closing
DS MT18: cylindrical plug type with monolithic body - Straight type - Quick 90° closing
Handling: lever operated with PP handle (Standard: right; Option: left)

Process connections:
Standard flanges: UNI PN16/40 DN15-20-25 ANSI #150/RF DN ½“ - ¾“ - 1“
Standard threaded unions: BSP-M ½” - ¾” NPT-M ½” - ¾”
Options: further connections types or direct connections to the process without cocks
(See page 1.49)
Vent: Standard: blind Option: see page 1.50
Drain: Standard: cock DS D12 threaded ½” Option: see page 1.50

Accessories
See from page 1.55

Weights
Cocks DS GR18: Kg. 7,4 approx. (With flanges UNI DN20 PN40)
Cocks DS MT18: Kg. 6,1 approx. (With flanges UNI DN20 PN40)

Spare parts
MIDDLE TERMINAL Glass tube: Length = Centre-to-centre distance [M] - 30 mm
CODE: MJT Protection: Length = Centre-to-centre distance [M] - 100 mm
Cocks DS GR18: see from page 1.72
(Drawing with components and parts list see page 1.66)
Cocks DS MT18: see from page 1.64
(Drawing with components and parts list see page 1.67)

Utilization

The product is NOT suitable for use in the following instances:


 if it is likely to be exposed to vibrations (Glass tube will break)
 if the installation is situated by a walkway (Possibility of blows/impact)
 if exposed to steam (Shortens glass tube life)

Rev.2 Specifications and design can be subject to change without notice 1.41