Date: 2/11/2024

SURVEY OF EXISTING MILL MACHINERY INSTALLED AND OPERATING AMPS DATA FOR THE UPGRADI
To: Mr Tey-Mill Manager
Please provide the following information data: This surveys are crucial for the mill upgrade and ele

Item Station (Existing Installed Information) Units


1 Threshing Station
1. Number of Unit of Thresher Drum?
1.1 Number of Unit of first stage?
1.2 Number of Unit of 2nd stage?
2. Number of Fruit Elevators?
3. Number of Bottom Cross Conveyor
3.1 Diameter of Conveyor?
3.2 Gearmotor Kw

2 Press/Digester Station
1. Number of Press & Digester/Any additional units?
2. P15-Number of units
3. P25 Number of Units
4. Digester Feeding Conveyor Number of units?
4.1 Diameter of Conveyor & motor Kw

3 Depericarping Station
1. CBC Below Presses- Number of Units?
1.1 Diameter of CBC 1A / Kw of GM (Gearmotor)
1.2 Diameter of CBC 1B/Kw of GM

Line 1
2. CBC No.2 (Line 1)
2.1 Diameter & Kw of Gearmotor
3. Nut Polishing Drum
3.1 Diameter and Kw of GM
3.2 Fibre Cyclone Fan
Model and Motor Kw
3.3 Airlock Diameter and Kw of GM
4. Destoner System
Fan's Model & Motor Kw

Line 2
2. CBC No.2 (Line 2)
2.1 Diameter & Kw of Gearmotor
3. Nut Polishing Drum
3.1 Diameter and Kw of GM
3.2 Fibre Cyclone Fan
Model and Motor Kw
3.3 Airlock Diameter and Kw of GM
4. Destoner System
Fan's Model & Motor Kw

4 Kernel Recovery Station (Existing Line 1 & 2)


4.1 Number of Ripple Mills
4.2 Line 1: LTDS system
LTDS No.1 -Fan Model & Motor Kw
LTDS No.2 -Fan Model & Motor Kw
4.2 Line 2: LTDS system
LTDS No.1 -Fan Model & Motor Kw
LTDS No.2 -Fan Model & Motor Kw
4.3 Number of Claybath?
4.4 Number of Hydrocyclone?
4.5 Number of Kerenl Silos?

5 Fibre Conveyor system from Line 1 & Line 2 Below Fibre Cyclone
5.1 Diameter of Fibre Conveyor No.1 below Fibre Cyclone
Conveyor Gearmotor Kw/Running Amps?
5.1 Diameter of Fibre Conveyor No.2 below Fibre Cyclone
Conveyor Gearmotor Kw/Running Amps?

6 Clarification Station
6.1 Number of VCT
: Capacity No.1
: Capacity No.2
6.2 Number of Decanter
:Capacity Each
6.3 Number of Separator
: Capacity each
6.4 No. of Unit Vaccum Oil Dryer
: VD No.1: Capacity
: VD No.2: Capacity

7 Boiler Station
Number of Boiler ?
7.1 Boiler Number 1 : Capacity/Pressure
7.2 Boiler Number 2 : Capacity/Pressure
7.3 Boiler Number 3: Capacity/Pressure

8 Engine Room
Number of Steam Turbine
8.1 Turbine No. 1 Capacity:
8.2 Turbine No.2 Capacity:
8.3 Turbine No.3 Capacity:

9 EFB Press Station


Number of EFB Presses?
Any Additional required?

10 Electrical Distribution (Measurement) MCC Recording Amps


Existing Line 1 & 2 (from Engine Room MSB)
10.1 To Boiler No.1 MCC on full running load
10.2 To Boiler No.2 MCC on full running load
10.3 To Boiler No.3 MCC on full running load
10.4 To Solvent Extraction Plant MCC-Full Load

10.5 To Existing Sterilization Station-Full running load

10.6 To Loading Ramp Station-Full running load

10.7 Threshing Station-Full Load

10.8 Press/Digester station-Full Load

10.9 Depericarping Station-Full Load

10.10 Kernel Recovery Station-Full Load

10.11 To Water Treatment Plant

10.12 To Effluent Treatment Plant

10.13 To Mill office

10.14 To Fertilizer Plant

10.15 To EFB Press Station & Cake Dryer

Total Operating Amps in full mill capacity line 1 & line 2