ENGLISH

INSTALLATION MANUAL

AIR
CONDITIONER

Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
Floor standing

MFL67040414 www.lg.com
Rev.03_070819 Copyright © 2015 - 2019 LG Electronics Inc. All Rights Reserved.
2 TIPS FOR SAVING ENERGY
ENGLISH

TIPS FOR SAVING ENERGY


Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:

• Do not cool excessively indoors. This may be harmful for your health and may consume more
electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors and windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the
air flow or weaken the cooling / dehumidifying functions.

For your records


Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS 3

ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product.

! WARNING
It can result in serious injury or death when the directions are ignored.

! CAUTION
It can result in minor injury or product damage when the directions are ignored.

! WARNING
• Installation or repairs by unqualified persons can result in hazards to you and others.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.

Installation
• Always perform grounding.
- Otherwise, it may cause electric shock.
• Don’t use an electric cable or a terminal block which is damaged.
- Otherwise, it may cause a fire or electric shock.
• For installation of the product, always contact the service center or a professional installation
agency.
- Otherwise, it may cause a fire, electric shock, explosion or injury.
• Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
- If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not
attached securely, it could result in a fire or electric shock due to dust, water, etc.
• Always install an earth leakage breaker and a dedicated switching board.
- No installation may cause a fire and electric shock.
• Do not keep or use flammable gases or combustibles near the air conditioner.
- Otherwise, it may cause a fire or the failure of product.
• Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.
- It may cause injury or an accident.
• Do not disassemble or repair the product randomly.
- It will cause a fire or electric shock.
• Do not install the product at a place that there is concern of falling down.
- Otherwise, it may result in personal injury.
• Do not turn on the breaker or power under condition that front panel, cabinet, top cover, control box
cover are removed or opened.
- Otherwise, it may cause fire, electric shock, explosion or death.
4 IMPORTANT SAFETY INSTRUCTIONS
ENGLISH

Operation
• Do not share the outlet with other appliances.
- It will cause an electric shock or a fire due to heat generation.
• Do not use the damaged electric cable.
- Otherwise, it may cause a fire or electric shock.
• Do not modify or extend the electric cable randomly.
- Otherwise, it may cause a fire or electric shock.
• Turn off the breaker or power if strange sounds, smell, or smoke comes from it.
- Otherwise, it may cause electric shock or a fire.
• Keep the flames away.
- Otherwise, it may cause a fire.
• Do not use the electric cable near the heating tools.
- Otherwise, it may cause a fire and electric shock.
• Do not open the suction inlet of the indoor/outdoor unit during operation.
- Otherwise, it may electric shock and failure.
• Do not allow water to run into electrical parts.
- Otherwise, it may cause the failure of machine or electric shock.
• Hold the plug by the head when taking it out.
- It may cause electric shock and damage.
• Never touch the metal parts of the unit when removing the filter.
- They are sharp and may cause injury.
• Do not step on the indoor/outdoor unit and do not put anything on it.
- It may cause an injury through dropping of the unit or falling down.
• Do not place a heavy object on the electric cable.
- Otherwise, it may cause a fire or electric shock.
• When the product is submerged into water, always contact the service center.
- Otherwise, it may cause a fire or electric shock.
• Take care so that children may not step on the outdoor unit.
- Otherwise, children may be seriously injured due to falling down.
IMPORTANT SAFETY INSTRUCTIONS 5

ENGLISH
! CAUTION
Installation
• Install the drain hose to ensure that drain can be securely done.
- Otherwise, it may cause water leakage.
• Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to
the neighbors.
- Otherwise, it may cause dispute with the neighbors.
• Always inspect gas leakage after the installation and repair of product.
- Otherwise, it may cause the failure of product.
• Keep level parallel in installing the product.
- Otherwise, it may cause vibration or water leakage.
• For installation of the product, do not use the pipe less than 5m
- Otherwise, it may cause damage of compressor and to form dewdrop on the indoor unit.
- Also, it may cause to decrease capacity.
• Use caution when unpacking and installing.
- Sharp edges may cause injury.

Operation
• Avoid excessive cooling and perform ventilation sometimes.
- Otherwise, it may do harm to your health.
• Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
- The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
• Do not use an appliance for special purposes such as preserving animals vegetables, precision
machine, or art articles.
- Otherwise, it may damage your properties.
• Do not place obstacles around the flow inlet or outlet.
- Otherwise, it may cause the failure of appliance or an accident.
6 TABLE OF CONTENTS
ENGLISH

TABLE OF CONTENTS
2 TIPS FOR SAVING ENERGY
3 IMPORTANT SAFETY INSTRUCTIONS
7 INSTALLATION PLACE
7 Select the best Location

8 INSTALLATION
8 Indoor unit installation
9 Precautions in bending

10 WIRING CONNECTION
10 Connecting the cable

11 LEAKAGE TEST AND EVACUATION


11 Vacuum drying of the connecting pipes and the indoor unit

12 FINAL CHECK AND TEST RUN


13 CONVENIENT FUNCTIONS
13 Child Lock Operation Function
13 Auto Dry Function
14 Desired airflow direction memory function
14 Auto restart operation
15 Installer Setting-Group Setting
INSTALLATION PLACE 7

ENGLISH
INSTALLATION PLACE
Select the best Location
Indoor unit
- There should not be any heat source or steam near the unit.
- There should not be any obstacles to prevent the air circulation.
- A place where air circulation in the room will be good.
- A place where drainage can be easily obtained.
- A place where noise prevention is taken into consideration.
- Do not install the unit near the door way.
- Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.
- The indoor unit must keep the maintenance space.

300 mm
300 mm

300 mm
8 INSTALLATION
ENGLISH

INSTALLATION
Indoor unit installation
1 The mounting floor should be strong and
solid enough to prevent it from vibration.
2 Drill the piping hole with 65 mm diameter
hole-core drill at either the right or the left
of indoor unit. The hole should be sightly
slant to the outdoor side.
Knock-out hole

- When using knock-out hole to route


the piping, insert the plastic cover in
knock-out hole in order to prevent the
piping from damaged by sharp edge of
the hole.
200 mm
65 mm
65 mm
90 mm

Wall
INSIDE OUTSIDE

Core Drill

3 Insert the plastic tube through the hole.


4 Cut the extruded outside part of the plastic
tube, if necessary.
Wall
INSIDE OUTSIDE

Tilt
Plastic tube
(Bushing)
Cut if
necessary
More
than 15 mm
INSTALLATION 9

ENGLISH
Precautions in bending
1 If it is necessary to bend or stretch the tubing, use the spring which is attached to the tubing
instead of pipe bender.
- Please make a careful notice to make a smooth line.
- Hold the tubing with your two hands closely and then bend or stretch it slowly not to make
any crack.
- Remember that the radius (R) should exceed 70 mm (Refer to Fig. 1).
2 Do not repeat the bending process to prevent the tubing from cracking or crushing.
3 Keep in mind that the bending part should not be cracked and make the radius (R) as long as
possible (Refer to Fig. 2).

Spring

more than R 70 mm

(Fig. 1)

(Fig. 2)
10 WIRING CONNECTION
ENGLISH

WIRING CONNECTION
Connecting the cable
Indoor unit
* The inside and outside connecting cable can be connected after opening the inlet grille.
1 Open the inlet grille manually.
2 Open the control cover with screwdriver(⊕).

‫ں‬

‫ڹ‬ ‫ڸ‬
‫ں‬
Ground

Connecting
cable

3 Connect the cables to the terminal block(①) in the control box.


And fix the cable to cord clamp(②). Close the plastic cover of terminal block(①).

<Outdoor Unit Power Supply : 1 Ø> <Outdoor Unit Power Supply : 3 Ø>
1(L) 2(N) 3 Indoor unit 1(L) 2(N) 3 Indoor unit

1(L) 2(N) 1(L) 2(N) 3 Outdoor unit 1(L) 2(N) 3 Outdoor unit

POWER SUPPLY POWER SUPPLY

4 Secure the control cover to the original position with the screw(③).
5 Close the inlet grille.
LEAKAGE TEST AND EVACUATION 11

ENGLISH
LEAKAGE TEST AND EVACUATION
Vacuum drying of the connecting pipes and the indoor unit
The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on
the compressor.
1 Confirm that both the liquid side valve and the gas side valve are set to the closed position.
2 After connecting the piping, check the joints for gas leakage with gas leak detector.
3 Remove the service port nut, and connect the gauge manifold and the vacuum pump to the
service port by the charge hose.
4 Vacuum the indoor unit and the connecting pipes until the pressure in them lowers to below
0.8 Torr by the vacuum pump.
5 Remove the valve stem nuts, and fully open the stems of the 2-way and 3-way valves with a
hexagon wrench.
6 Tighten the valve stem nuts of the 2-way valve and 3-way valve.
7 Disconnect the charge hose and fit the nut to the service port.
(Tightening torque: 1.8 kgf·m)

Indoor unit Liquid side


Closed Outdoor unit
2-way valve/
3-way valve

Gas side

3-way
valve
Closed

Vacuum pump

OPEN CLOSE
12 FINAL CHECK AND TEST RUN
ENGLISH

FINAL CHECK AND TEST RUN


A test run allows you to check if the product
has been properly installed before operating
the product.
Hold down the Power button and Temp. down
button on the indoor unit simultaneously for 3
seconds. “Lo” appears on the display screen,
and the product performs a test run for 18
minutes.

MODE

Final check points during Test Run


1 Is the unit securely mounted?
2 Is the installation location adequate?
3 Does the water piping work adequately
and without leakage?
4 Are trapped drain lines installed at
condensated drain connections?
5 Has the refrigeration cooling cycle been
kept sealed?
6 Is the electrical wiring adequate and are
the screws tightened on terminals?
7 Does the remote control work properly?
8 Does the display on the indoor unit work
properly?
9 Do you hear any abnormal noises?
10 Does the heating/cooling work properly?
11 Does the water drain properly?
CONVENIENT FUNCTIONS 13

ENGLISH
CONVENIENT FUNCTIONS
Child Lock Operation Function Auto Dry Function
1 Press the fan speed button and high 1 Auto dry function can be setted/released
temperature setting buttons by manipulating indoor unit button or
simultaneously for 3 seconds. Or press the remote control.
X button on remote control.
2 When pressing the button after setting
2 During child lock operation, the function, evaporator in indoor unit will
- Whenever you press any button on be automatically dried as showing counting
display panel, it will immediately display 00 to 99 on its display panel.
"CL", which means display panel is
3 After indicating 99 on the display panel,
locked.
the unit will be automatically turned off.
- All the button on the indoor unit display
panel will not work. * Auto dry function is released at initial
state as standard.
- But the button on the remote controller
will be operated.
For Setting Auto Dry Function
If manipulating indoor unit, press the
button and MODEbutton simultaneously for 3
seconds.
If manipulating remote control for Cooling
MODE
Only model, press button.
The indoor unit will respond with beep once
and indicate “SC” on its display panel. Then
Auto dry function will be set.

For Releasing Auto Dry Function


If manipulating indoor unit, press the
button and MODEbutton simultaneously for 3
3 Press the fan speed button and high seconds.
temperature setting buttons
If manipulating remote control for Cooling
simultaneously for 3 seconds again. The
Only model, press button.
unit will respond with beep. child lock
The indoor unit will respond with beep twice
operation will removed.
and Auto dry function will be removed.

MODE
14 CONVENIENT FUNCTIONS
ENGLISH

Desired airflow direction Auto restart operation


memory function When power is supplied again after unit
(Up/down louver only) operation has been stopped because of
interruption of power supply due to outage or
You can register a discharge angle in the other causes, auto restart will be performed
product by turning off the Auto Swing function by remembering previous setting.
at the desired angle.
- When power is supplied, outdoor unit
operation will be started within 3 minutes.
For setting desired airflow
direction memory function 1 Auto restart operation can be
established/released by manipulating
Press the Mode button and Temp. down indoor unit button.
button on the indoor unit simultaneously for 3 * When initial state, Auto restart operation
seconds. to register the discharge angle. will be set up as standard.

For releasing desired airflow For releasing restart function


direction memory function
Press the on/off, fan speed, high temp and
- Switch from the mode in which the Auto low temp buttons (4 buttons) simultaneously
Swing angle was registered to another mode for 3 seconds.
to clear the registered angle.
The unit will respond with beep and restart
- Change the vane angle by setting another operation will be removed.
function, such as Power Cooling Operation,
to clear the registered angle. For setting restart function
After funtion release, Press the on/off, fan
speed, high temp and low temp buttons (4
buttons) simultaneously for 3 seconds.
The unit will respond with beep and restart
MODE
operation will be setted.

MODE
CONVENIENT FUNCTIONS 15

ENGLISH
Installer Setting-Group
Setting
This function is the settings when controlling
group control.

MODE

1 Press the ,
MODE , (3 buttons)
simultaneously for 3 seconds.
- The indoor unit will respond with beep
once and indicate “SL” on its display
panel. Then Slave will be set.
2 One more press the ,
MODE , (3
buttons) simultaneously for 3 seconds.
- The indoor unit will respond with beep
twice. Then Master will be set.

! NOTE
• Set as a master by default
• Some functions may not be available
during a group control except basic
operation settings
• Some functions may not be supported,
depending on the model.
16