Crack Width Calculations (ACI 350-06/ACI 224R-01)

Input Data
Material Properties :-
Concrete Compressive Strength FC` 48 Mpa Moduls Of Rupture Modifier 1.00

Concrete Compressive Strength Fy 420 Mpa

Section Properties :-
Section Width b 1000 mm Exposure Condition
Section Thickness h 300 mm wc-all 0.00 mm
User Define
Cover To Center Of Closest Tension Bars dc 50 mm wc-all 0.20 mm
Cover To Center Of Tension Bars dcg 50 mm Max Stress Of Tension Steel
Important Note:- As Per ACI350R-01 When The Concrete Cover Exceed 50mm Use Only 50mm Normal Enviromental Exposure-One Way Member

Applied Service Moment :-


Applied Tension Axial Force (+ve) Ts 180 Kn

Applied Service Moment Ms 220 Kn.m Method 01


Section Reinfocement :- wcr = 11*10^-6*β*Fs*(A*dc)^1/3 Method 01
No Dia Area/mm2 wcr = 2*(Fs/Es)*β*((dc)^2+(S/2)^2))^0.5Method 02
Main 7 16 1406.72
Tension RFT
Extra 7 16 1406.72
Spacing Between Bars S 150 mm

Compression RFT No Dia Area/mm2


Compression RFT Main 7 16 1406.72
Spacing Between Bars S 150 mm

Output Data

Concrete Modulus Of Elasticity Ec 32562.555 Mpa


Steel Modulus Of Elasticity Es 200000.00 Mpa
Modular Ratio n 6.142 U.Less
N.A Depth X 75.308 mm
Gross Moment Of Inertia Ig 2250000000.00 mm4
Cracked Moment Of Inertia Icr 674343031.640621 mm4
Moduls Of Rupture Fr 4.30 Mpa

Cracking Moment Mcr 64.43 Kn.m Mcr < Ma Need Crack Width Calculations
Stress On Tension Steel Fs 378.69 Mpa Fs > Fs max - Unsafe
Max Stress On Tension Steel Fs-max 229.47 Mpa
Check For High Bond Bars Fs-bond 280.00 Mpa Fs > Fs bond - Unsafe
Depth Factor β 1.286 U.Less
Effective Tension Area A 7142.857 mm2

Allowable Crack Width wcr-all 0.20 mm


Eng Abdulrahman Elgohary
Actual Crack Width wcr-act 0.380 mm Unsafe Actual > Allowable Tel 0525273709 / United Arab Emirates