1 STRUCTURAL SPECIFICATIONS 2 FOOTING DETAIL 3 BEAM DETAIL & SCHEDULE

B
A) CONCRETING: L1

L2
L-SUPPORT M-SUPPORT R-SUPPORT
A.1 FOOTING,COLUMN,NON POST-TENSIONED BEAMS AND GIRDERS,SLABS,

B
TOP BAR TOP BAR TOP BAR

L1/4

L1/4

L2/4

L2/4

L3/4
REINFORCED CONCRETE WALLS,STAIRS
TOP TB
---------------------------------------F'c=20.68 Mpa (3,000 psi) @28 DAYS N.G.L. BARS
A.2 SUSPENDED SLABS,BEAMS & GIRDERS (FOR POST-TENSIONED MEMBERS ONLY) MIDDLE BAR

D
-----------------------------------------F'c=20.68 Mpa (3,000psi)@ 28 DAYS (AS SPECIFIED)

DEPTH OF EXCAVATION
BOTTOM
BARS BB
A.3 GROUND FLOOR SLAB ON FILL
R-SUPPORT
-----------------------------------F'c=17.24Mpa (2,500psi) @28 DAYS L-SUPPORT M-SUPPORT BOT. BAR AT SECTIONS

BAR "L"
BOT. BAR BOT. BAR
A.4 OTHERS NOT SPECIFIED---------F'c=20.68Mpa (3,000psi) @ 28 DAYS

L1/5

L1/5

L2/5

L2/5

L3/5
L&R-SUPPORT MIDSPAN
B) REINFORCEMENT:

VARIES

MINIMUM

LENGTH

H
B.1 ALL MILD REINFORCING BARS SHALL BE ROUND "DEFORMED STRUCTURAL GRADE"
CONFIRMING TO ASTM A-615
----------------------------------Fy=276 Mpa(40,000psi) LEFT SUPPORT MIDSPAN RIGHT SUPPORT
B.2 ALL REINFORCING BARS DIAMETER IN MILLIMETERS INDICATED ON THE PLANS SHOULD MARK DIMENSION BAR Ø STIRRUPS
BE STRICTLY FOLLOWED.ANY DEVIATION FROM THOSE SPECIFIED SHALL HAVE THE WRITTEN TOP BOTTOM TOP BOTTOM TOP BOTTOM B x D (mm) (mm)
APPROVAL OF THE STRUCTURAL ENGINEER.

T
B.3 WHERE SPLICING IS REQUIRED;SLAB,BEAM & GIRDER REINFORCING BARS SHALL BE SPLICED FTB-1 & 2 3 3 3 3 3 3 200 x400 16 mm Ø AA
AT QUARTER POINT AND A MINIMUM LENGTH OF 40 TIMES THE DIAMETER OF THE BAR. BAR "S"
B.4 COLUMN VERTICAL BARS SHALL BE SPLICED AT MID-FLOOR HEIGHT,AND A B-1 3 2 2 3 3 2 200 x400 16 mm Ø AA
PLAN

WIDTH
MINIMUM LENGHT OF 40d ALSO NOT MORE THAN 50 B-2 3 3 3 3 3 3 200 x400 16 mm Ø A
BARS SHALL BE SPLICED AT ANY GIVEN SECTION.
C) STURCTURAL STEEL % OF THE TOTAL NUMBER OF SCHEDULE OF FOOTING B-3 4 4 4 4 4 4 250 x400 16 mm Ø A
C.1 ALL STRUCTURAL STEEL,BOTH ANGLESAND STEEL PLATES SHALL CONFORM TO
ASTM A36---------------------------Fy=284.16Mpa(36,000psi) SIZE (m) BOTTOM BARS B-4 4 3 3 4 4 3 200 x400 16 mm Ø A
DEPTH OF
C.2 WELDING ELECTRODES SHALL BE E60xx SERIES. MARK THK REMARKS
(mm) WIDTH LENGTH BAR 'S' BAR 'L' EXCAVATION B-5/CB 5 5 5 5 5 5 250 x400 16 mm Ø A
C.3 MACHINE AND ANCHOR BOLTS SHALL CONFORM TO ASTM A-325
F-1 400 1.50 1.50 12 - 16 mmØ 12 - 16 mmØ 2.00 (VERIFY) ISOLATED FTG B-6 3 3 3 3 3 3 250 x400 16 mm Ø A

TYP. COLUMN ELEVATION F-2 400 1.25 1.25 10 - 16 mmØ 10 - 16 mmØ 2.00 (VERIFY) ISOLATED FTG B-7 5 5 5 5 5 5 250 x450 16 mm Ø A
RB-1 4 3 3 4 4 3 200 x400 16 mm Ø AA
S1 RB-2 4 3 3 4 4 3 250 x400 16 mm Ø AA
50 mm

NOTE: NO FOOTING SHOULD REST ON BACKFILL MATERIALS. STIRRUPS "AA" 10mm. Ø 1 @ 50mm., 2 @ 100mm., 2 @ 150mm., REST @ 250mm. O.C.
(SEE COLUMN SCHEDULE)

Lo

"A" 10mm. Ø 1 @ 50mm., 3 @ 100mm., 4 @ 150mm., REST @ 250mm. O.C.


ROOF DECK BEAM

5 WALL FOOTING DETAIL


Ø 10 mm VERT. BAR
6 DET. OF TWO-WAY SLAB 7 DET. OF ONE-WAY SLAB
DISTRIBUTION OF COLUMN TIE

W/IN CENTER HALF

CLASS "C" SPLICE


4" CHB (INTERIOR WALL) @ EVERY 600 mm O.C.
OF COLUMN HT.

0.40
6" CHB (EXTERIOR WALL) Ø 10 mm HORIZONTAL BAR
@ EVERY 3 LAYER OF CHB TOP BARS TOP BARS
50 mm

SECOND FLOOR BEAM @ SUPPORTS

MIN.DEPTH OF EXCAVATION
@ SUPPORTS
Lo

N.G.L.

3 - 10mmØ BARS
S1 10mmØ @ 0.30m O.C.
TOP BARS
50 mm

3-10mm Ø
(SEE COLUMN SCHEDULE)

0.80

LONGITUDINAL @ SUPPORTS
BARS
10mm Ø @ 0.30m O.C.
TRANSVERSE BARS
B = SMALLER DIMENSION OF COLUMN BOT BARS
0.20

SHORT SPAN
S3

SHORT SPAN
S 1 = 2*S SECTION PLAN @ MIDSPAN
DISTRIBUTION OF COLUMN TIE

S 2 = NOT TO EXCEED B/4 OR 4"

0.40
S2 S 3 = NOT TO EXCEED 1646 OF VERTICAL TOP BARS
BAR, 48 db OF TIES, OR B.
9 COLUMN SCHEDULE @ SUPPORTS
50 mm

Lo = LARGEST COLUMN DIMENSION BOT BARS


Lo

BOT BARS
BUT NOT LESS THAN 1/6 OF @ MIDSPAN
CLEAR COLUMN HEIGHT OR CONTINUOUS
C-1 C-2 C-1/C-2/PC
GROUND FLR TO 2ND FLOOR

GROUND FLR TO 2ND FLOOR

2ND FLOOR TO ROOF LEVEL


450mm.
FOOTING

SPAN SPAN
LONG LONG

LEGEND
SUSPENDED SLAB SCHEDULE
WF - WALL FOOTING S-1 - TWO WAY SLAB
C1/F1 - COLUMN & FOOTING
R E I N F O R C E M E N T
- CONTINUOUS COLUMN SIZE : 250 x 400 mm SIZE : 250 x 400 mm SIZE : 200 x 400 mm
THK
S-2 - ONE WAY SLAB
VERT. BARS : VERT. BARS : VERT. BARS :
MARK PARALLEL TO SHORT SPAN PARALLEL TO LONG SPAN REMARKS
10 - 16 mm Ø 8- 16 mm Ø 8 - 16 mm Ø (mm)
- TERMINATED COLUMN TB @ SUPPORT BB @ MIDSPAN TB @ SUPPORT BB @ MIDSPAN
TIES : 1 - 10 mm Ø TIES : 1 - 10mm Ø TIES : 1 - 10mm Ø
B-1 - BEAM DESIGNATION S-1 100 12 mmØ @ 0.200 m.o.c. 12 mmØ @ 0.200 m.o.c.
PC - PLANTED COLUMN TWO-WAY
1 @ 50mm., 2 @ 100mm., 1 @ 50mm., 2 @ 100mm., 1 @ 50mm., 2 @ 100mm.,
S-2 125 12 mmØ @ 0.150 m.o.c. 12 mmØ @ 0.150 m.o.c. TWO-WAY
SW - STAIR WELL 3 @ 150 mm., REST @ 3 @ 150 mm., REST @ 3 @ 150 mm., REST @
200mm. O.C. 250 mm. O.C. 250 mm. O.C. LEDGE 75 10 mmØ @ 0.300 m.o.c. 10 mmØ @ 0.300 m.o.c. ONE-WAY

C:\Users\jonthan\Documents\_PASCUAL APARTMENT2
ENGINEER: CADD BY : R.O.A.
REPUBLIC ACT 9226 Drawings and specifications PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.
duly signed, stamped or sealed as instruments of service are DATE : 10-20-11
properties and documents of the architect, whether the object
MA. TERESITA S. DE LEON STRUCTURAL SCHEDULES

Jonathan M. Lontok, uap for which they are made is executed or not. It shall be unlawful
for any person, without written consent of the architect or PTR NO.: 3643214 REG NO.: 71644
DESIGNED BY

DATE
:

:
JML/ROA

10-20-11 PROPOSED 2-STOREY COMMERCIAL BLDG. MR & MRS. JULIUS PASCUAL


STRUCTURAL DETAILS
S 04
A R C H I T E C T author of said documents to duplicate or to make copies of
said documents for use in the repetition of and for other DATE: 1-4-2011 DATE: CHECKED BY : JML SHT.# 04
___ OF 04
___
projects or building, whether executed partly or in whole.
MAKATI CITY
LOCATION: 258 QUIRINO AVE. TAMBO PARANAQUE CITY ADDRESS : 258 QUIRINO AVE. TAMBO PARANAQUE CITY
PLACE: TIN: 164-749-829 APPROVED BY : JML ARCHITECTURAL