MAKING MODERN LIVING POSSIBLE

Thermostatic expansion valves


Type T2 / TE2
Maximum flexibility The original…
For more than 30 years, the Danfoss T2 type valve has set the standard in all dry
− maximum dedication expansion applications throughout the “catchment” market.
Other manufacturers have tried to copy the design, but the continuous product
development that Danfoss employs ensures that the valve functionality is always
on the cutting edge of technology.

REFRIGERATION &
AIR CONDITIONING DIVISION
T2 / TE2: reliable and easy to use
Thermostatic expansion valves regulate the injection of liguid refrigerant into evaporators.
Injection is controlled by the refrigerant superheat. Therefore the valves are especially suit-
able for liquid injection in ”dry“ evaporators where the superheat at the evaporator outlet
is proportional to the evaporator load.

Advantages - Large temperature range. - Interchangeable orifice assembly


Equally applicable to freezing, refrigeration - easy stocking
and air conditioning applications. - easy capacity matching
- Rated capacities from 0.5 to 15.5 kW - better service
(0.15 to 4.5 TR) for R22.

Facts - Can be supplied with MOP - Valves for special temperature ranges can
(Max. Operating Pressure). be supplied.
Protects the compressor motor against ex- - Flare / solder adaptor can be supplied.
cessive evaporating pressure during normal
operation.

Features - Laser-welded power element: - Stainless steel power element, capillary


- longer diaphragm life tube and bulb:
- high pressure tolerance and working - high corrosion resistance
pressure - high strength and vibration resistance
- Laser-engraved label.

Capillary tube in
stainless steel

Laser-welded stainless
steel power element

Bulb in stainless steel


Flare or solder outlet

Interchangeable orifice
assembly with dirt Easy adjustment of
protection filter superheat setting

Inlet in flare. Solder


adaptor is an option
Technical data and ordering
Thermostatic element with: bulb strap, without: orifice, filter cone and nuts Flare × flare connection
Connection Code no.
Pressure Capillary
tube Range N Range NM Range NL Range B
Refrigerant Valve type equalization Inlet × outlet 1)
Flare –40 to +10°C –40 to –5°C –40 to –15°C –60 to –25°C
m in. × in. mm × mm Without MOP MOP +15°C MOP 0°C MOP –10°C Without MOP MOP –20°C
TX 2 - 1.5 3
/8 × 1/2 10 × 12 068Z3206 068Z3208 068Z3224 068Z3226 068Z3207 068Z3228
R22
TEX 2 ¼ in. 1.5 3
/8 × 1/2 10 × 12 068Z3209 068Z3211 068Z3225 068Z3227 068Z3210 068Z3229
TZ 2 - 1.5 3
/8 × 1/2 10 × 12 068Z3496 068Z3516
R407C
TEZ 2 ¼ in. 1.5 3
/8 × 1/2 10 × 12 068Z3501 068Z3517
TN 2 - 1.5 3
/8 × 1/2 10 × 12 068Z3346 068Z3347 068Z3393 068Z3369
R134a
TEN 2 ¼ in. 1.5 3
/8 × 1/2 10 × 12 068Z3348 068Z3349 068Z3392 068Z3370
TS 2 - 1.5 3
/8 × 1/2 10 × 12 068Z3400 068Z3402 068Z3406 068Z3408 068Z3401 068Z3410
R404A/R507
TES 2 ¼ in. 1.5 3
/8 × 1/2 10 × 12 068Z3403 068Z3405 068Z3407 068Z3409 068Z3404 068Z3411

Thermostatic element with: bulb strap, without: orifice, filter cone and nuts Flare × solder connection
Connection Code no.
Pressure Capillary
Refrigerant Valve type equalization tube Range N Range NL Range B
Inlet Outlet –40 to +10°C –40 to –15°C –60 to –25°C
Solder Flare ODF solder
m Without MOP MOP +15°C MOP –10°C Without MOP MOP –20°C
TX 2 - 1.5 3
/8 in. 1
/2 in. 068Z3281 068Z3287 068Z3357 068Z3319
TX 2 - 1.5 10 mm 12 mm 068Z3302 068Z3308 068Z3366 068Z3361 068Z3276
R22
TEX 2 ¼ in. 1.5 /8 in.
3
/2 in.
1
068Z3284 068Z3290 068Z3359 068Z3220
TEX 2 6 mm. 1.5 10 mm 12 mm 068Z3305 068Z3311 068Z3367 068Z3363 068Z3277
TZ 2 - 1.5 3
/8 in. 1
/2 in. 068Z3329
TZ 2 - 1.5 10 mm 12 mm 068Z3502 068Z3514
R407C
TEZ 2 ¼ in. 1.5 3
/8 in. 1
/2 in. 068Z3446 068Z3447
TEZ 2 6 mm. 1.5 10 mm 12 mm 068Z3503 068Z3515
TN 2 - 1.5 3
/8 in. 1
/2 in. 068Z3383 068Z3387
TN 2 - 1.5 10 mm 12 mm 068Z3384 068Z3388
R134a
TEN 2 ¼ in. 1.5 3
/8 in. 1
/2 in. 068Z3385 068Z3389
TEN 2 6 mm. 1.5 10 mm 12 mm 068Z3386 068Z3390
TS 2 - 1.5 3
/8 in. 1
/2 in. 068Z3414 068Z3416 068Z3429 068Z3418 068Z3420
TS 2 - 1.5 10 mm 12 mm 068Z3435 068Z3423 068Z3436 068Z3425 068Z3427
R 404A/R507
TES 2 ¼ in. 1.5 3
/8 in. 1
/2 in. 068Z3415 068Z3417 068Z3430 068Z3419 068Z3421
TES 2 6 mm. 1.5 10 mm 12 mm 068Z3422 068Z3424 068Z3437 068Z3426 068Z3428

Orifice assembly
Range N: –40 to +10°C Range B: –60 to –25°C Code no.
Rated capacity Rated capacity Rated capacity Rated capacity
Orifice in tons (TR) in kW in tons (TR) in kW Flare × Flare Solder adaptor
no.
R404A R404A R404A R404A version version
R22 R407C R134a R22 R407C R134a R22 R22
R507 R507 R507 R507
0X 0.15 0.16 0.11 0.11 0.50 0.50 0.40 0.38 0.15 0.11 0.50 0.38 068-2002 068-2089
00 0.30 0.30 0.25 0.21 1.0 1.1 0.90 0.70 0.20 0.21 0.70 0.70 068-2003 068-2090
01 0.70 0.80 0.50 0.45 2.5 2.7 1.8 1.6 0.30 0.45 1.0 1.6 068-2010 068-2091
02 1.0 1.1 0.80 0.60 3.5 3.8 2.6 2.1 0.60 0.60 2.1 2.1 068-2015 068-2092
03 1.5 1.6 1.3 1.2 5.2 5.6 4.6 4.2 0.80 1.0 2.8 3.5 068-2006 068-2093
04 2.3 2.5 1.9 1.7 8.0 8.6 6.7 6.0 1.2 1.4 4.2 4.9 068-2007 068-2094
05 3.0 3.2 2.5 2.2 10.5 11.3 8.6 7.7 1.5 1.7 5.2 6.0 068-2008 068-2095
06 4.5 4.9 3.0 2.6 15.5 16.7 10.5 9.1 2.0 1.9 7.0 6.6 068-2009 068-2096
The rated capacity is based on: Evaporating temperature te = +5°C for range N and te = –30°C for range B,
condensing temperature tc = +32°C, and refrigerant temperature ahead of valve tl = +28°C.

Solder adaptor without orifice assembly Filter


Connection - ODF solder Code no. Filter type Code no. The flare orifice in T2 and TE2 can be used
1
/4 in. 068-2062 For flare connection 068-0003 with a solder adaptor when the orifice filter
6 mm 068-2063 For solder adaptor 068-0015 is replaced with a specific filter intended
6 mm 068-41011)
for solder adaptors. Only in this way the
The adaptor is for use with thermostatic sealing requirements of DIN 8964 can be
3
/8 in. 068-2060
expansion valves T2 and TE2. fulfilled.
10 mm 068-2061
When the adaptor is fitted correctly it meets Solder adaptors for filter driers (FSA) must
10 mm 068-41001) not be used in the T2 inlet.
the sealing requirements of DIN 8964.
1
) Including filter
Quality in everything we do
T2 / TE2 are part of the Danfoss thermostatic expansion If the component you are looking for is not mentioned in
valve program which covers a wide range of components this leaflet or if you have special requirements, Danfoss
used in refrigeration systems. Our production utilises partner wholesalers or our local Danfoss team can offer
state-of-the-art processes and every product is thoroughly you help and guidance and will do their utmost to fulfill
tested in accordance with the most demanding standards. your needs.

Related products

Electronic
thermostat
Thermostatic
Solenoid valve expansion
valve

Temperature
sensor

Sight glass Ball valve Filter drier Ball valve

The Danfoss expansion valve programme

Thermostatic exp. valves Thermostatic exp. valves Electronically controlled Electronically controlled Electronically controlled
in stainless steel for for smaller and medium exp. valves for smaller exp. valves for medium exp. valves for larger
smaller plants sized plants plants sized plants plants

Visit Danfoss on www.danfoss.com

DKRCC.PB.AA0.A3.02 / 520H1258 Produced by Danfoss AC-DSL. 03.2006

You might also like