0% found this document useful (0 votes)
17 views2 pages

JSJDJFJ

Alsidodifj

Uploaded by

S B
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views2 pages

JSJDJFJ

Alsidodifj

Uploaded by

S B
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

6FM100/12Volt 100Ah

Solar GEL Series Batteries are specially designed for telecom use with
12+ years design life in float service. Byadopting a new AGM separator and
centralised venting system, the battery can be installed in any position while
manintaning high reliability.

Heavy Duty Grid Negative........Lead


Mechanized assembly Terminal........Copper
Non-spillable construction Positive........Lead dioxide
High Reliability and Stability Electrolyte........Sulfuric acid
Sealed and Maintenance-free Separator........Fiber glass
Long Life and low self-discharge design Safety Valve........EPDR
Container........ABS(UL94-HB) / (UL94-V0)

Nominal Voltage 12V

Ba�ery Model Rated capacity (10Hour rate) 100Ah

Cells Per ba�ery 6

Length Width Height Total Height


Dimension
331mm 173mm 213mm 220mm

Approx Weight 27.00 Kg

Internal Resistance Full charged at 25℃(77℉): Approx 5.0mΩ

Max.discharge current 800A(5s)

Floa�ng design life @ 25℃ (77℉) 12 years

10Hour rate(10A/10.8V) 5Hour rate(17A/10.8V) 3Hour rate(25A/10.5V) 1Hour rate(55A/10.5V)


Capacity @ 25℃ (77℉)
100Ah 85Ah 75Ah 55Ah

40℃ (104℉) 25℃ (77℉) 0℃ (32℉) -15℃(5℉)


Capacity affected by Temp(10 HR)
102% 100% 85% 65%

A�er 3 months storage A�er 6 months storage A�er 12 months storage


Self Discharge @ 25℃ (77℉)
93% 84% 65%

Cycle Use 14.5-14.9V (Ini�al charging current less than 30.0A)


Charge method @ 25℃ (77℉)
Float Use 13.6-13.8V
3

3
21 3
218

8.5

20
9

20

173
M8
331 17.5

F.V / TIME 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h


A 360.00 220.00 175.00 115.00 60.50 35.00 26.00 21.00 17.54 11.58 11.00 5.70
9.60V
W 3816.00 2336.40 1872.50 1242.00 659.45 381.50 286.00 231.00 192.96 128.57 122.10 64.13

A 330.00 211.00 160.83 109.17 60.00 33.58 25.50 20.00 17.21 11.40 10.50 5.60
10.20V
W 3597.00 2342.10 1793.29 1228.13 675.00 379.49 288.15 227.00 195.31 129.39 119.18 63.56

A 306.04 201.66 150.00 105.83 58.00 32.92 25.00 19.00 17.00 11.25 10.30 5.53
10.50V
W 3366.46 2268.68 1695.00 1206.50 661.20 376.90 286.25 218.50 195.50 129.38 118.45 63.60

A 278.67 199.92 140.00 101.00 57.00 32.08 24.50 18.67 16.25 10.96 10.00 5.46
10.80V
W 3065.33 2279.09 1603.00 1166.55 658.35 370.56 284.20 217.47 189.31 127.66 116.50 63.61

A 241.00 190.00 130.00 94.00 55.00 31.25 23.50 18.33 15.54 10.67 9.75 5.40
11.10V
W 2723.30 2194.50 1508.00 1099.80 643.50 365.63 276.13 216.33 183.39 125.87 115.05 63.72

Note: The above datas are average values. (Edition 2017-11)


Page 1 of 2
6FM100/12Volt 100Ah

120

2.16/6.48/13.0 100
Voltage (V)

1.85/5.55/11.1 80
1.80/5.40/10.8

Capacity(%)
0.25C 0.20C 0.17C 0.12C 0.1C 60
1.75/5.25/10.5 100%DOD 50%DOD 30%DOD
0.05C
0.55C 0.40C
1.70/5.10/10.2 40
1.65/4.95/9.90
3C 2C 1C 20
1.60/4.80/9.60
0
7min 15min 27min 1h 2h 3h 4h 5h 8h 10h 20h 200 400 600
0 800 1000 1200 1400

Number of cycles (cycles)


Discharge time

Charged
( V / 12V )

Volume

Current

Voltage
( V / CE )
( V / 8V )

( V / 6V )

( V / 4V )

(%) (XCA) (V)


140
15.6 10.4 7.8 5.2 2.6
120 0.25
15.0 Charged Volume
15.0 10.0 7.5 5.0 2.5 Cyc 100
le U 0.20
se 14.0 Charge Voltage
14.4 9.6 7.2 4.8 2.4 80
0.15
13.0
Stand
by Use 60
13.8 9.2 6.9 4.6 2.3
0.10
40 12.0
13.2 8.8 6.6 4.4 2.2
20 0.05
11.0
Charging Current
-10 0 10 20 30 40 50 60 0 0
0 2 4 6 8 10 12 14 16 18 20
Ambient temperature() Charging time (hours)

11 0

100
2.30V/Cell
5 90
Life (years)

Capacity (%)

80
1
70

60
40℃ 30℃ 20℃
50

0 40
10 20 30 40 50
0 2 4 6 8 10 12 14 16 18 20
Temperatura() Storage time: months

120 15 7.5 5.0 120 0.24


Charge Volume

100 14 7.0 4.7 100 0.20


Charge Voltage
Charge Voltage (V)

Charge Currient (CA)

80 13 6.5 4.3 80 0.16


Charge Volume (%)

① Discharge
Capacity (%)

100% (0.05 CA*20h)


50% (0.05 CA*10h)
12 6.0 4.0 ② Charge 60 0.12
60 Charge Voltaje 2.275V /cell
Testing conditions: floating voltage: 2.27 to 2.30V /cell Charge Current 0.1 CA
③ Temperature 25℃
Ambient temperature: 25 () 11 5.5 3.7 40 0.08
40

10 5.0 3.3 20 0.04


20 Charge Current

9 4.5 3.0 0 0
0 0 2 4 6 8 10 12 14 16 18 20 24 28
1 2 3
Charge Time (h)
Life (years)

Note: The above datas are average values. (Edition 2017-11)


Page 2 of 2

You might also like