Technical parametersTechnical Parameter

Models POW-LVM3K-24V-H

AC mode

Rated input voltage 110/120Vac

Input voltage range (90Vac-140Vac) ±2%

Frequency 50Hz/ 60Hz (Auto detection)

47±0.3Hz ~ 55±0.3Hz (50Hz);


Frequency Range
57±0.3Hz ~ 65±0.3Hz (60Hz);

Overload/short circuit protection Circuit breaker

Efficiency >95%

Conversion time
10ms (typical)
(bypass and inverter)

AC reverse protection Available

Maximum bypass overload current 40A

Inverter mode

Output voltage waveform Pure sine wave

Rated output power (VA) 3000

Rated output power (W) 3000

Power factor 1

Rated output voltage (Vac) 120Vac

Output voltage error ±5%

Output frequency range (Hz) 50Hz±0.3Hz; 60Hz±0.3Hz

Maximum Efficiency >92%


(102% < load <110%) ±10%: report error and turn off the
output after 5 minutes;
(110% < load < 125%) ± 10%: report error and turn off
Overload protection
the output after 10 seconds;
Load >125% ±10%: report error and turn off the output
after 5 seconds;
Peak power 6000VA

Loaded motor capability 2HP

Rated battery input voltage 24V (Minimum starting voltage 22V)

Undervoltage alarm/ shutdown voltage/ overvoltage alarm


Battery voltage range
/ overvoltage recovery... settable on LCD screen)

Power saving mode Load≤50W

AC charging

Battery type Lead acid or lithium battery

Maximum charge current


0-40A
(can be set)

Charge current error ±5Adc

Charge voltage range 20–33Vdc

Short circuit protection Circuit breaker and blown fuse

Circuit breaker specifications 40A

Overcharge protection Alarm and turn off charging after 1 minute

PV charging

Maximum PV open circuit voltage 450Vdc

PV operating voltage range 120~450Vdc

MPPT voltage range 120~400Vdc

Battery voltage range 20~33Vdc

Maximum input power 4000W

PV charging current range


0~80A
(can be set)

Charging short circuit protection Blown fuse

Wiring protection Reverse polarity protection

Hybrid charging Max charger current specifications (AC charger + PV charger)

Max charger current (can be set) 0~80A


Certified specifications

Certification CE(IEC 62109-1)/FCC/SAA

EMC certification level EN61000, C2

Operating temperature range -10℃ ~ 55℃

Storage temperature range -25℃ ~ 60℃

Humidity range 5% to 95% (Conformal coating protection)

Noise ≤60dB

Heat dissipation Forced air cooling, variable speed of fan

Communication interface USB/CAN/RS485(WiFi/GPRS)/Dry node control

Size (L*W*D) 378mm*280mm*103mm

Weight (kg) 8