LIT5124
LIT5124
Spectrophotometer
• Speed analysis of a wide range of samples and enable your analysts to carry
out unique experiments using preprogrammed procedures and storage capacity
for custom calibrations.
The DR/4000 is ideal for analyzing compounds that require multiple wave-
lengths, longer path lengths or time course operations. It is available in
two models:
• DR/4000 V has visible spectrum capabilities with a range of 320 to 1100 nm.
2
E x p a n d
Your Capabilities
The DR/4000 is ideally suited for applications in diverse fields
such as water and wastewater treatment, industrial processes,
quality control, food and beverage processing, pharmaceutical
production and chemical synthesis. And because the DR/4000
Spectrophotometer is part of a complete solution that supplies
everything you need to run even the most complicated tests,
you can expand your testing capabilities. You get:
3
The D R
/4 0 0 0
Surpasses Comparable
Spectrophotometers
Designed to increase Resolution and Accuracy
productivity and The DR/4000 gives you industry-leading accuracy and outstanding precision
for the most reliable test results. You can set the wavelength step size as
efficiency without small as 0.1 nm, and the sample blank correction feature permits automated
measurements with precision and stability. And when you power up the
sacrificing accuracy, DR/4000, it automatically aligns the lamp, performs a wavelength calibration
and an offset correction; and performs memory, voltage and system tests.
the DR/4000 outper-
forms any other Scanning Measurements
spectrophotometer The DR/4000 U can scan across the range of 190 to 1100 nm, while the
DR/4000 V scans from 320 to 1100 nm. With the scan overlay, scan add and
in its class. Take a scan subtract features, you can easily analyze and compare sample results.
The DR/4000 U automatically performs lamp changeover when it moves
closer look at its from visible to UV wavelengths.
4
Flexible Sample Handling
The innovative, patented modular sample
compartment can accommodate multi- or single-
cell holders. In addition to handling one-inch,
one-centimeter, five-centimeter and 10-centimeter
sample cells, the DR/4000 also accommodates:
*Not included
5
Advanced
Guides You Through Each Test
Software
Conduct Sophisticated Experiments
The DR/4000’s advanced software enables you to conduct experiments on
challenging samples. Most operations can be accomplished with just a few
keystrokes, and intuitive messages guide you from one screen to the next.
Scanning Function
First, identify the optimum wavelength at which the
study should be conducted by scanning across the
wavelength range. Just select the wavelength scan range,
key in the rate at which the data will be collected, and
select either %T or ABS. You will then be prompted by
the instrument to take a baseline and start the data
collection. The data is available either tabulated or
displayed in a graphical form, with peaks and valleys
located automatically. Zoom in or out to view a selected
range of data. Automatically or manually store the scan
for future recall. Scans may be overlayed, and then
added or subtracted.
Time-Course Function
In the next phase of the experiment, you may wish to
ascertain the length of time required for maximum color
development in the test sample. With a DR/4000, you
can monitor changes in %T or ABS at a single
wavelength over a defined period of time. Just select the
wavelength, key in the time period (hours, minutes or
seconds) and select either %T or ABS. The instrument
will store the data, which can be recalled onto the
screen in graphical or tabular form for further study.
6
User Calibration
In the final phase of the study, you must generate a calibration
curve. After selecting the option for user-entered calibrations,
you are prompted to enter the appropriate information into a
table. As the measurements are made, the DR/4000 prompts
you for each standard sample. Once the data collection is
completed, the DR/4000 prompts you to select linear,
quadratic, cubic or piece-wise linear formulas. The calibration
curve is displayed in graphical or tabular format for review. If
desired, you can add more points or delete outliers. You can
also identify alternative chemical species (P instead of
PO4-3 for example) at this time, if desired.
Custom Calibrations
Store up to 200 of your own calibrations in its memory. Each
calibration curve can contain up to 16 data points. A simple
programming procedure makes it easy to key in your data to
adapt the instrument to your laboratory’s protocols or special
testing requirements. The DR/4000 accommodates any test
within its analysis range. Just establish a calibration curve
using the appropriate data or standards, and store.
Preprogrammed Calibrations
More than 130 preprogrammed Hach methods are permanently
stored in the instrument’s non-volatile memory. You can call up
wavelength measurements with just a few keystrokes, and a
user-oriented interface guides you through each procedure.
As new methods become available, they are packaged into
software upgrades you can purchase to update your DR/4000.
Standard Additions
To ensure confidence in your results, the DR/4000 includes a standard
additions option. Just key in the appropriate information, add an aliquot
of standard to your sample and the DR/4000 calculates the percent
recovery. Used with Hach calibrations or user-entered methods, standard
additions can identify interferences, bad reagents or faulty procedures.
Multiwavelength Analysis
With the DR/4000, you can measure a sample at up to four different
wavelengths, in rapid succession, in one operation.
7
Sophisticated Optics
The DR/4000’s optical system consists of a Seya-
Namioka split-beam diffraction grating monochroma-
tor, a light source and silicon photodiode detectors.
Innovative reference beam technology ensures stable,
accurate readings. A halogen gas-filled tungsten lamp
is the light source for visible spectrum analysis, while
a deuterium lamp provides the light source for UV When the light source is activated, the optics system
separates the light into a monochromatic beam, which
analysis. When you power up the DR/4000, a self-test passes through the sample cell to the photodetector.
procedure checks offset correction, wavelength calibra- The photodetector responds to the light’s intensity and
relays that information to the microprocessor. Readout
tion, lamp alignment, memory system and voltages. displays in concentration, ABS or %T.
J
F
E
G
A
H
I B
K C
I
D B
Deuterium Lamp A
Aperture Stop B
Rotating Concave Spherical Mirror C
Tungsten Halogen Lamp D
Rotating Concave Holographic Grating E
Order Sorting Filter F
Reference Detector G
Fused Silica Beam Splitter H
Convex Fused Silica Lens I
Sample Cell J
Measurement Detector K
8
Sample Specification
for
DR/4000 UV-VIS
The spectrophotometer is a scanning, laboratory instrument
capable of analysis in the near infrared, visible and ultraviolet
spectrum. It has an intuitive user interface to simplify complex
methods; proven, preprogrammed procedures based on accepted
standard methods; illustrated manuals for both operating the
instrument and running the tests; and technical support available
by telephone and/or web site.
A backlit, liquid crystal display screen is provided for the graphical display of
spectral scans, calibration curves and data points along with quantitative data
generated during the analysis. Display contrast and viewing angle is adjustable.
Operator-selectable readout modes is available for concentration, ABS and %T.
Alpha-numeric prompting messages and menus is provided on the display in multiple
languages including English, French, Spanish, German, Portuguese and Japanese.
A read-only memory (ROM) is provided with preprogrammed calibration data for more
than 130 colorimetric test procedures to provide direct readout in concentration mode
without the need for calculations or calibration curves. The instrument provides
storage of up to 200 user-generated calibrations with linear, cubic, quadratic and
piecewise curve-fitting capability. It has the capacity to store up to 200 data points,
10 spectral scans, and 10 time course scans, and is able to store, recall or print data
with the push of a button. Users have the ability to download data to a printer, PC
or LIMS, and, using Microsoft® Windows®-compatible software, output it as a text file
or spreadsheet.
9
Parameters, Methods,
The table below lists test ranges, methods of analysis and corresponding reagent sets for the DR/4000
Spectrophotometer. The complete procedure for each test is included in the manual supplied with the instrument.
The ranges are given for the precalibrated instrument readout; higher ranges can be analyzed by sample dilution.
12
Flow-Cell Module
This module speeds the measurement of multiple
samples; eliminates errors caused by using different,
unmatched sample cells; and contributes to high
sensitivity and accurate measurement of very low
concentrations. The Flow-Cell Module, designed to
increase precision, also prevents contamination or
dilution between successive samples. Available with
a 1-inch or 1-cm pathlength quartz cell.
COD/Test ‘N Tube™/UniCell™
Carousel Adapter
This five-position, 16-mm sample cell adapter is designed
to provide a way to group, record and quickly perform
several sample measurements at a time. Configured to
accept vials containing chemical oxygen demand,
Test ‘N Tube™ (chlorine, total nitrogen, nitrate, nitrite,
ammonia, phosphorus), and UniCell™ (ammonium, nitrate,
total nitrogen, phosphate, and sulfate) premeasured
reagents, this carousel speeds testing with minimal human
intervention. Depending on the setup menu selected by
the analyst, the DR/4000 automatically rotates the sample
cells and reads the concentrations in a preprogrammed
sequence. An alert sounds when the readings are complete.
Technical Support
Whether you need advice about ordering reagents,
detecting interferences or entering your own calibrations,
technical support staff are as close as your telephone. For
intensive training on the DR/4000 and other Hach systems,
contact the dealer or distributor serving your area.
Extended Warranty
and Certification
In addition to the one-year
warranty offered on the DR/4000,
Hach also offers an extended
warranty agreement, which covers
parts and service for your instrument
for an additional one to three
years. Performance verification
services are also available to ensure
that your instrument meets factory
specifications.
13
DR /4000 UV - VIS
Spectrophotometer
Specifications:
Wavelength range:
DR/4000 U: 190 to 1100 nm
DR/4000 V: 320 to 1100 nm
Wavelength accuracy: ±1 nm
Monochromator Design: Seya-Namioka split-beam
monochromator
Wavelength calibration: Internal, automatic
at turn-on with visual
feedback
Wavelength repeatability: ±0.1 nm
Wavelength resolution: 0.1 nm
Grating: 1200 lines/mm;
8 nm/mm dispersion
Wavelength slew rate: 15,000 nm/minute
Spectral bandwidth: 4 nm nominal,
5 nm maximum,
Source lamp: Deuterium (DR/4000 U
only); Gas-filled tungsten
(DR/4000 U and DR/4000 V)
Source lamp change: Automatic changeover
Display: Backlit, graphic, liquid
crystal display with
adjustable viewing angle,
contrast control
Photometric range: -3.0 to 3.0 ABS
Photometric linearity: ±0.002 ABS
Stray light: >3.3 ABS, <0.05 %T
at 220 nm and 340 nm
Readout modes: Concentration, absorbance,
% transmittance
External outputs: Parallel or RS-232 Serial
Sample compartment: Modular, easily accessible,
interchangeable for diverse
testing requirements
Line power: AC line power selectable for
95 to 240 Vac, 50/60 Hz
Dimensions: 42W x 29D x 16H cm
(16.5 x 11.4 x 6.3 in)
Weight: 9 kg (20 lb.)
Compliance: European CE mark, ETL and
ETLc safety marks
14
Catalog Information:
48000-00 DR/4000 U Spectrophotometer
Visible and UV spectrum. Includes 1-inch matched sample cells; 1-cm
matched quartz sample cells; Single Cell Module; AccuVac® and 16-mm
vial adapters; 1-inch and 1-cm cell adapters; Carousel Module; and
carousel inserts (1-inch, four-position and 1-cm, six-position); dust
cover; replacement lamp kit; illustrated manual set; and power cord.
48000-02 DR/4000 U Spectrophotometer (European model)
Includes continental European power cord and fuses.
48100-00 DR/4000 V Spectrophotometer
Visible spectrum only. Includes 1-inch matched sample cells; Single Cell
Module; AccuVac® and 16-mm vial adapters; 1-inch and 1-cm cell
adapters; dust cover, replacement lamp kit; illustrated manual set; and
power cord.
48100-02 DR/4000 V Spectrophotometer (European model)
Includes continental European power cord and fuses.
48090-03 Sipper Module, 1-inch quartz sample cell
48090-06 Sipper Module, 1-cm quartz sample cell
48090-07 Sipper Module, Micro 1-cm pathlength quartz cell
48070-05 Flow-Cell Module, 1-cm quartz cell
48070-04 Flow-Cell Module, 1-inch quartz cell
48070-08 Temperature Control Module
48070-02 Carousel Module Kit
48070-01 Single Cell Module Kit
48190-00 1-inch Square Cell Adapter
48105-00 1-inch Carousel Adapter, four position
48115-00 1-cm Carousel Adapter, six position
48186-00 5-cm Single Cell Adapter
48118-00 10-cm Single Cell Adapter
48588-00 1-cm Microcell Adapter
48584-00 1-cm Square Cell Adapter
48274-00 COD/TNT/UniCell™, 16-mm Carousel Adapter,
five position
48189-00 COD/TNT, 16-mm Round Cell Adapter
48187-00 AccuVac®, 1-inch Single Round Cell Adapter
26126-02 1-inch Glass Sample Cell, matched pair with stoppers
26659-02 1-inch Precision Matched Sample Cells, matched pair
26659-04 1-inch Precision Matched Sample Cells, set of four
26659-08 1-inch Precision Matched Sample Cells, set of eight
24102-12 1-inch Polystyrene Sample Cell with cap, 12/pk
20951-00 1-cm Glass Sample Cells, matched pair, square
26295-00 1-cm Low Volume microcell, plastic, disposable,
100/pk (1.5mL)
48228-00 1-cm Quartz Sample Cell, 1 pair with caps
26244-50 5-cm Quartz Sample Cell with cap
26292-50 5-cm Optical Glass Sample Cell with cap
26244-01 10-cm Quartz Sample Cell with cap
26292-01 10-cm Glass Sample Cell with cap
48129-00 Computer Interface Cable, 6 ft.
49665-00 HachLink™ Software
49503-00 Printer Cable
49544-00 Software Upgrade Package
An exceptional, complete
laboratory analysis
system that includes a
superior instrument,
prepared reagents, proven
methods, complete
instructions and personal
service for running
Water •
UV - VIS Wastewater
Boiler/cooling water
•
•