Conv WP-Explosion Proof MCP
Conv WP-Explosion Proof MCP
UL, C-UL, CSFM Listed; Non-Coded Manual Stations, Cast Metal Construction
FM Approved; MEA (NYC)
Acceptance*
Features
Common mechanical and electrical features:
• Rugged cast metal construction
• Terminal connections for In/Out Wiring
• Visible break rod provides status indicator; optional, not required for
operation
• Standard operation station will mount semi-flush on a single gang box,
2 1/2 in. deep
• Operation is compliant with ADA requirements
• Listed to UL Standard 38
Models are available with:
• Single action operation with SPST contacts
• Dual action PUSH operation with SPST contacts Figure 1: 2099-9138 Single Action Manual Station
• Explosion-proof/weather-proof operation with DPDT contacts
Accessories:
• 2975-9211, weather-proof surface mount cast aluminum box, provides
NEMA Type 3R rating**
• 2975-9212, indoor operation surface mount box
Description
Cast metal construction: For applications requiring cast metal
construction, these non-coded manual stations provide a variety of
models and operations. Single action stations are operated by pulling
the handle. Dual action stations require that you push the top "PUSH"
lever to grab the "PULL" lever.
Indication and reset: When pulled, the alarm condition is mechanically Figure 2: 2099-9139 Dual Action Manual Station
latched and indicated by the extended handle. You can reset by
®
unlocking and opening the enclosure. A Simplex “B” key controls the
lock.
* Refer to page 2 for additional agency listing references. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety
Code. For non-explosion-proof models, see CSFM Listing 7150-0026:0215 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination,
revision, and possible cancellation. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are
the property of Tyco Fire Protection Products. ** NEMA 3R rating is achieved when used with weatherproof mounting box 2975-9211 and supplied gaskets.
S2099-0009 Rev 8 02/2021
Non-Coded Manual Stations, Cast Metal Construction
Product selection
Table 1: Manual station models
Model* Description
2099-9138 Single Action Station; SPST, N.O. contact
2099-9139 Dual Action Station with PUSH Lever; SPST, N.O. contact
Explosion-Proof & Weather-Proof Station with Enclosure; DPDT contacts; NEMA 4X rated; UL listed, FM and CSFM Approved for:
2099-9144 **
Class I, Groups B, C, and D; Class II, Groups E, F, and G; also FM approved for Class III Groups E, F, and G
252-019 B key for manual station reset
Note:
* UL, C-UL listing is under model numbers shown except as noted. For other listing agencies, reference Signal Communications Corporation (SIGCOM),
model Series SG-32. Accepted for use – City of New York Department of Buildings – MEA 382-94-E Volume II (SIGCOM).
** For listings, reference Signal Communications Corporation (SIGCOM) model Series SGX-32; CSFM ref. 7151-1408:0112.
Table 2: Accessories (model 2099-9144 includes enclosure, separate box is not required)
Model Description
2975-9211 Red Weatherproof Box; cast aluminum construction with gasket kit, required for NEMA 3R rating
2975-9212 Red Surface Mount Box; stamped steel construction
2099-9829 Twelve replacement break rods
Specifications
Table 3: Standard application stations
Specification Rating
Contact ratings (resistive) UL, C-UL, & CSFM = 1 A @ 30 VDC or 125 VAC; FM = 1 A @ 30 VAC/VDC
Operation with 2975-9211 box Temperature range = -40°F to 150°F (-40°C to 66°C); suitable for outdoor applications; NEMA 3R
rated
Operation with 2975-9212 box Temperature range = 32°F to 140°F (0°C to 60°C); intended for indoor applications
Humidity range = up to 90% RH at 90°F (32°C)
Table 4: Explosion-Proof & Weather-Proof (Model 2099-9144)
Specification Rating
Contact ratings 1 A @ 30 VDC, resistive; 10 A @ 120 VAC, resistive
Temperature range -67°F to 302°F (-55°C to 150°C); suitable for outdoor applications; rated NEMA 4X
Table 5: General specifications (all models)
Specification Rating
Wiring connections Terminal blocks for IN/OUT wiring, up to 14 AWG (2.08 mm )
2
Housing and handles Cast zinc; both PUSH and PULL handles
Colors Red housings with white levers and white raised lettering
Additional information Refer to Installation Instructions supplied with product
© 2021 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without
notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co.
Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are
registered trademarks of the National Fire Protection Association (NFPA).
S2099-0009 Rev 8 02/2021