SCHEDULES OF LOAD & COMPUTATION 01. ALL ELECTRICAL WORKS HEREIN SHALL COMPLY TO THE LATEST PROVISIONS OF THE PHILIPPINE ELECTRICAL CODE, THE
ULES AND REGULATIONS OF THE LOCAL CODES ENFORCING AUTHORITIES CONCERNED.
POWER CKT. BREAKER
CKT L.O. C.O. OTHERS VOLTS AMPS. WIRE GROUND CONDUITS 02. ALL ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER
WATTS AT AF P COMPLYING TO THE PSEC SAFETY STANDARDS.
1 10 1000 230 4.34 15 80 2 2-3.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc 03. POWER SERVICE ENTRANCE SHALL BE 220 VOLTS, 60 HERTZ.
2 10 1000 230 4.34 15 80 2 2-3.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc
04. MINIMUM SIZE OF WIRE AND TO BE USED SHALL BE 2.0 mm2 THW AND 15 mmØ FCP RESPECTIVELY.
3 8 800 230 3.47 15 80 2 2-3.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc
05. ALL PIPES SLEEVES SHALL BE PROVIDED WITH PROPER SUPPORT OR ANCHORAGE NECESSARY FOR PERMANENT
4 10 1000 230 4.34 15 80 2 2-3.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc CONNECTIONS WITH CONCRETE WALLS AND BEAMS.
5 13 1300 230 5.65 15 80 2 2-3.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc 06. NO CIRCUIT POWER AND SPECIAL OUTLETS HAVE A LOAD NOT MORE THAN 80% OF ITS RATING.
6 16 1600 230 6.95 15 80 2 2-3.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc 07. ALL CONVENIENCE OUTLET, 3 PRONG ( PARALLEL SLOT, GROUNDING TYPE ) AND LIGHTING SWITCHES SHALL BE RATED 15A
250V, AND 10A RESPECTIVELY AS MANUFACTURED BY "PANASONIC" OR APPROVED EQUAL.
7 15 2700 230 11.73 20 80 2 2-5.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc
8 15 2700 230 11.73 20 80 2 2-5.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc 08. THE MINIMUM SIZE OF CONDUIT SHALL 3.5mm² IN TYPE THW COPPER ( PHELPS DODGE ) AND 20mmØ PVC RESPECTIVELY
( REFER TO LOAD SCHED. FOR OTHER WIRE SIZES AND TYPE OF INSULATION ).
9 12 2160 230 9.39 20 80 2 2-5.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc
09. FOR EACH SPARE BRANCH CIRCUIT IN PANEL BOARD PROVIDE ONE 20mmØ PVC EMPTY CONDUIT CONNECTED TO AN
10 ACU 1HP 1620 230 2.17 30 80 2 2-5.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc OCTAGONAL BOX AT ABOVE CEILING.
11 ACU 1HP 1620 230 2.17 30 80 2 2-5.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc 10. ALL FEEDERS AND BRANCH CIRCUIT SHALL BE INSTALLED AS INDICATED ON PLAN, INDIVIDUAL CIRCUIT HOMERUNS TO
PANELBOARD SHALL NOT BE CONBINED IN THE SAME RACEWAY UNLESS OTHERWISE INDICATED ON THE PLAN.
12 ACU 1HP 1620 230 2.17 30 80 2 2-5.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc
13 ACU 1HP 1620 230 2.17 30 80 2 2-5.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc 11. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SERVICE ENTRANCE FOR CONNECTION TO THE POWER SUPPLY
AND ALSO THE ACTUAL LOCATION OF TELEPHONE SERVICE REQUIREMENT FOR THE CONNECTION TO MAIN TEL CABINET.
14 SPARE 230 2.17 80 2 2-5.5mm² thhn 1-2.0mm² TW IN 15mmØ pvc
12. THE METHOD OF WIRING SHALL BE AS FOLLOWS:
total: 20740 90.17 A. POWER SERVICE ENTRANCE --------------------------------------- RSG CONDUIT SCH. 40
B. LIGHTING AND CONV. OUTLETS ------------------------------------ PVC CONDUIT SCH. 40 BY NELTEX
IT= 20740230
W x 80% DF USE : 14mm² THHN 8.0mm² TW C. TELEPHONE, INTERCOM & CABLE TV ---------------------------- PVC CONDUIT SCH. 40 BY NELTEX
VOLT IN 25mmØ RSC 13. ALL MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED SHALL BE BRAND NEW AND MUST BE OF APPROVED TYPE.
= 72.13 AMPERES MAIN :80AT, ,2P 60H z,230v 14. MOUNTING HEIGHT SHALL BE AS FOLLOWS:
A. KILLOWATT HOUR METER...............................1.60 M. ABOVE FIN. FLR. LINE
B. PANEL BOARD...................................................1.80 M. ABOVE FIN. FLR. LINE
C. SWITCHES.........................................................1.50 M. ABOVE FIN. FLR. LINE
D. CONVENIENCE OUTLET...................................0.30 M. ABOVE FIN. FLR. LINE
E. TELEPHONE, TV & INTERCOM OUTLET ........0.30 M ABOVE FIN. FLR. LINE
F. SPECIAL OUTLET ............................................ AS DIRECTED BY ARCHITECT
15. ALL MOUNTING HEIGHTS ARE SUBJECT TO ARCHITECT'S APPROVAL PRIOR TO INSTALLATION.
LEGEND: 16. ALL METAL HOUSING OF LIGHTING FIXTURES, BOXES, CONDUITS, PANELBOARDS SHALL BE PROPERLY CONNECTED TO THE
GROUNDING SYSTEM OF THE BUILDING.
PINLIGHT CIRCUIT LINE ABOVE CEILING
17. UPON COMPLETION OF ELECTRICAL CONSTRUCTION WORK, THE FOLLOWING TEST SHALL BE PERFORMED BY THE
CONTRACTOR INCLUSIVE OF THE INSTALLATION TO BE REPORTED IN DETAILS ON FORMS APPROVED BY THE OWNER
INCANDESCENT LAMP CIRCUIT LINE BELOW FLOOR REPRESENTATIVE.
A. INSULATION RESISTANCE
B. GROUND RESISTANCE TEST
FLUORESCENT LAMP SWITCH LINE C. OPERATIONAL TEST
D. SYSTEM TEST AND ACCEPTANCE
CONVENIENCE OUTLET M CIRCUIT HOMERUN
WP
WEATHER PROOF Sa ONE GANG SWITCH 80 AT WORKMANSHIP: THE WORK THROUGHOUT SHALL BE EXECUTED IN THE MOST AND THOROUGH MANNER KNOWN TO TRADE
AND TO THE SATISFACTION OF THE ARCHITECT AND THE ENGINEER.
CONVENIENCE OUTLET
REF
REF OUTLET S abc THREE - GANG SWITCH 1 2
ACU
ACU OUTLET M KILOWATT HOUR METER 15 AT 15 AT SITE!
PANEL BOARD SERVICE ENTRANCE 3 4
CIRCUIT BREAKER LINE
TEL
TELEPHONE OUTLET ( W/ RJ 45 ) 15 AT 15 AT
MCB
MAIN CIRCUIT BREAKER TELEPHONE OUTLET ( W/ RJ 45 ) 5 6
LAMP POST
20 AT 20 AT
7 8
20 AT 30 AT
9 10
30 AT 30 AT
11 12
30 AT SPARE
MDP
M 2 - 14mm² THHN
13 14
1 - 8.0mm2 TW
IN 25 mmØ RSC
80 AT
3.5mm² TW
GROUND WIRE
N.G.L.