LOADS ON STRUCTURAL MEMBERS

1) SLAB: S1 (A&B), S2(A&B) Load on Slab


Slab Unfactored Trap.Load Triang.Load
Assumed thickness = 150mm no. Load of slab (KN/m) (KN/m)
A) Dead Load A B A B
1) Self load 0.15*25 = 3.75 KN/m2 S1 7.8148 9.424 11.428 9.37776 9.37776
S2 7.8148 13.259 12.012 10.41973333 10.4197333
2) Finishing Load S3 4.862 4.844 3.744
a) Screed (50 mm) 21*50 = 1.05 KN/m2
b) Plaster (12+50mm) 20.4*0.062= 1.2648 KN/m3

c) Tile(1" ) 0.25 KN/m2 Formula Used:


B) Live load Triangular Load: WLx/3
a) Access provided 1.5 KN/m2 Trapezoidal Load: WLx/2 * (1-1/(3.b^2)) where, b= Ly/Lx
b) Access not provided 0 KN/m2
Total 7.8148 KN/m2
Factored Load (F = 1.5) 11.7222 KN/m2 Slab Slab
Type of Size d D
2) SLAB: S3 (Cap Slab) no. Slab (mm) (mm)
Assumed thickness = 100 mm S1 Two way Cont. 100 150
A) Dead Load S2 Two
Twoway
wayCont.
SS 100 150
1) Self load 0.100*25 = 2.5 KN/m2 S3 cap slab 75 100

2) Finishing Loads Slab DIMENSIONS OF SLAB


a) Plaster (12+18mm) 20.4*0.03= 0.612 KN/m3 no.
B) Live load Lx Ly

a) Access provided 0 KN/m2 A B A B


b) Access not provided 0.75 KN/m2 S1 3.6 3.6 3.62 4.8
c) Water Tank 1 KN/m2 S2 4 4 5.93 4.8
Total 4.862 KN/m2 S3 2.31 3.6
Factored Load (F = 1.5) 7.293 KN/m2
Load For Cantilever Slab portion = DL + Plaster + Inaccessible IL = 5.7648 KN/m2

LOAD ON STAIRCASE

FOR LANDING FOR GOING


1) Self weight = 0.175*25 = 4.375 KN/m2 1) Self weight = 5.78125 KN/m2

2)Screed (30mm) = 21*0.03= 0.63 KN/m2 2)Screed(30mm)= 21*0.03= 0.63 KN/m2


3) Marble (18mm) = 26.5*0.018= 0.477 KN/m2 3) Marble (18mm)= 26.5*0.018= 0.477 KN/m2
4) Plaster (12mm) = 20.4*0.012= 0.2448 KN/m2 4) Plaster (12mm)= 20.4*0.012= 0.2448 KN/m2
Total FF Load 1.3518 KN/m2 Total FF Load 1.3518 KN/m2

Live Load 3 KN/m2 Live Load 3 KN/m2


Total on Plinth and
50% Load Distributed 8.7268 KN/m2 Total 10.133 KN/m2
Roof Beam Each 4.363 KN/m2

STAIRCASE DETAILS REMARKS:


Riser Tread Waist Slab Landing
Thickness Slab

150 mm 200 mm 125 mm 175 mm Load from waist slab (1 m)


= Area of slab* 1* Density of RCC
` 4.363 10.13 4.363 = √(0.15^2 + 0.2^2)*0.125 *1 *25
4KN/ 3KN/ 4KN/ = 0.78125 KN/m
m2 m2 m2 Waist slab load for unit length = 0.78125/0.2 = 3.90625 KN/m2
R2 = (4.363*1.18*0.59 +
10.133*1.8*2.08 + 1.18 3.6 m 0.62m
4.363*0.62*3.29) / 3.6 = m
13.854 KN/m
R1 = 4.363*(1.18+0.62) + 10.133*1.8 - 13.854 = 7.577 KN/m

Load due to steps = Area of step * Density * 1


=1/2 * 0.2 * 0.15 *25
Load due to steps = Area of step * Density * 1
Load on Mid Landing Beam = 13.854 KN/m =1/2 * 0.2 * 0.15 *25
Load on Roof and Plinth Beam = 7.577 KN/m = 0.375 KN/m
Steps Load per unit length = 0.375/0.2 = 1.875 KN/m2

LOADS ON BEAMS
Load Thick. Density Ht. (mm) Load (KN/m)
Parapet 230 mm 20 KN/m3 1000 4.6 The height of wall is obtained after deducting the beam depth.
Wall 230 mm 20 KN/m3 1150 5.29 Reactions of mid landing beam B1= 13.854 KN/m
2650 12.19 Reactions of landing beam B8= 7.577 KN/m
Tri. Trap. Parapet Wall Total Factored
b D d Span Self Wt. Load Load Load Load Load Load
Beam Type mm mm mm mm KN/m KN/m KN/m KN/m KN/m KN/m KN/m
B1
(Mid-
Landing
) SS 230 350 300 2310 2.0125 0 0 0 5.29 21.1565 31.735
B2 Cont 230 350 300 3620 2.0125 0 9.424 4.6 0 32.7313608 49.097
B3 Cont 230 350 300 4800 2.0125 0 11.428 4.6 0 42.022068 63.033
B4 Cont 230 350 300 3600 2.0125 0 0 0 12.19 14.2025 21.304
B5 SS 230 350 300 3600 2.0125 9.37776 0 0 12.19 23.58026 35.37
B6 Cont 230 350 300 3600 2.0125 18.75552 0 0 0 20.76802 31.152
B7 Cont 230 350 300 3600 2.0125 9.37776 0 4.6 0 34.43762 51.656
B8 Cont 230 350 300 2310 2.0125 0 13.259 0 12.19 35.0385 52.558
B9 Cont 230 350 300 3620 2.0125 0 22.683 0 0 24.6955 37.043
B10 Cont 230 350 300 4800 2.0125 0 23.44 0 0 25.4525 38.179
B11 Cont 230 350 300 4000 2.0125 10.41973333 0 4.6 0 37.32432933 55.986
B12 Cont 230 350 300 4000 2.0125 20.83946667 0 0 0 22.85196667 34.278
B13 Cont 230 350 300 4000 2.0125 10.41973333 0 4.6 0 37.32432933 55.986
B14 Cont 230 350 300 5930 2.0125 0 13.259 4.6 0 49.0644472 73.597
B15 Cont 230 350 300 4800 2.0125 0 12.012 4.6 0 42.606068 63.909
B16 Cont 230 350 300 2310 2.0125 0 0 0 12.19 14.2025 21.304
B17 SS 230 350 300 2310 2.0125 3.744 0 0 0 20.0993224 30.149
B18 SS 230 350 300 3600 2.0125 0 4.844 0 0 27.148596 40.723
B19 SS 230 350 300 3600 2.0125 0 4.844 0 0 27.148596 40.723
B20 SS 230 350 300 2310 2.0125 3.744 0 0 0 20.0993224 30.149
NOTE: IN BEAMS B1 AND B8, THE STAIRCASE LOAD IS ADDED IN THE TOTAL
AND IN THE RESPECTIVE ADJACENT BEAMS THE LOAD OF CANTILEVER SLABS ARE ADDED IN TOTAL.

LOAD ON COLUMNS
Unit Weight Influence Area
1m 9" Factored
Beam 1m 9" Parapet 9'' Wall Slab Beam Parapet 9'' Slab Load Load
Column (KN/m) (KN/m) (KN/m2) (KN/m2) (m) (m) Wall (m2) (m2) (KN) (KN) Remarks

B4,B16: DL, B1:DL+Stair


B1,B16 2.65m: load, 1.15m wall above
B16,B4: 2.0125 2.65m : 53 :1.155 0.67965 B16&2.65m wall above B1
C1 B1: 15.8665 1.15m : 23 B4: 1.8 1.15m:0.2656 99.119 148.6785 and B4

B1,B16 B1: DL+Stair load,


B2,B5,B16 :1.155 2.65m: B16,B5: DL, 1.15m wall
:2.0125 2.65m : 53 B2:1.81 0.67965 above B16 &2.65m wall
C2 B1: 15.8665 4.6 1.15m : 23 7.8148 B5: 1.8 1.81 1.15m:0.2656 6.786 155.448 233.172 above B5, Parapet

B2,B3,B6: DL
C3 2.0125 4.6 7.8148 6.01 4.21 10.946 127.102 190.653 Parapet, Slab: DL+LL
B3,B7: DL,
C4 2.0125 4.6 7.8148 4.2 4.2 8.32 102.892 154.338 Parapet, Slab: DL+LL
B4, B11: B4: 1.8 B4,B11: DL, B8: DL+Stair
2.0125 B11: 2 load,2.65m wall above B4
C5 B8: 9.5895 4.6 53 7.8148 B8: 1.155 2 0.67965 3.91 127.217 190.8255 and B8, Parapet

B5: 1.8 B5,B9: DL, B8: DL+Stair


B5, B9: 2.0125 B9: 1.81 load,2.65m wall above B5
C6 B8: 9.5895 53 7.8148 B8: 1.155 0.67965 9.188 158.881 238.3215 and B8

No walls , Beam: DL
C7 2.0125 7.8148 8.01 15.998 151.241 226.862 Slab: DL+LL
Beam: DL, Slab: DL+LL
C8 2.0125 4.6 7.8148 6.2 3.8 9.12 111.328 166.992 Parapet
Beam: DL, Slab: DL+LL
C9 2.0125 4.6 7.8148 4.965 4.965 5.93 89.273 133.91 Parapet
Beam: DL, Slab: DL+LL
C10 2.0125 4.6 7.8148 7.365 5.365 10.73 133.454 200.181 Parapet
Beam: DL, Slab: DL+LL
C11 2.0125 4.6 7.8148 4.4 4.4 4.8 76.706 115.059 Parapet

C12 2.0125 4.6 4.6 4.862 2.955 0 0 1.33056 22.616 33.924 Beam DL, Slab DL+LL

C13 2.0125 4.6 4.6 4.862 2.955 0 0 1.33056 22.616 33.924 Beam DL, Slab DL+LL

C14 2.0125 4.6 4.6 4.862 2.955 0 0 1.33056 22.616 33.924 Beam DL, Slab DL+LL

C15 2.0125 4.6 4.6 4.862 2.955 0 0 1.33056 22.616 33.924 Beam DL, Slab DL+LL
Load from upper floor column C12, C13, C14, and C15 are added on column C1,C2, C5, and C6 are added correspondingly.
Self weight of column = Unit weight of RCC * Volume
For Ground Floor = 25*0.4*0.4*(3-0.35-0.125) 10.1 KN
=10.1 KN

For First Self weight of column = Unit weight of RCC * Volume


Floor (Terrace) = 25*0.4*0.4*(3-0.35-0.1) 10.2 KN
=10.2 KN

All are
HIGHEST LOAD ON COLUMN OF TERRACE FLOOR (FACTORED) = Equally Loaded 33.924 KN

HIGHEST LOAD ON COLUMN OF GROUND FLOOR (FACTORED) = C6 238.3215 KN


CHECK:

Total Load Beared By Columns


(Unfactored)= 1332.661 KN

Total Load (Slab + Beam + Wall + Staircase +Parapet)


(Unfactored) = 1239.894 KN
Slab 750.933008 KN Error = 0.65% # SATISFACTORY FOR PRELIMINARY DESIGN
Beam 141.700125 KN
Wall 156.3057 KN
Parapet 141.45 KN
Staircase 49.50561 KN
LOADS ON STRUCTURAL MEMBERS
Load on Slab
Slab Unfactored Trap.Load Triang.Load
1) SLAB: S1 (A&B), S2(A&B) no. Load of slab (KN/m) (KN/m)
Assumed thickness = 125mm A B A B
A) Dead Load S1 6.537 5.916 7.354 5.883 5.883
1) Self load 0.125*25 = 3.125 KN/m2 S2 6.537 8.665 7.627 6.537 6.537
S3 4.862 3.814 2.808
2) Finishing Load
a) Screed (50 mm) 21*50 = 1.05 KN/m2

b) Plaster (12+18mm) 20.4*0.03= 0.612 KN/m3


c) Tile(1" ) 0.25 KN/m2 Formula Used:
B) Live load Triangular Load: Load * Triangular Area / Span
a) Access provided 1.5 KN/m2 Trapezoidal Load: Load * Trapezoidal Area / Span
b) Access not provided 0 KN/m2
Total 6.537 KN/m2
Factored Load (F = 1.5) 9.8055 KN/m2
2) SLAB: S3 (Cap Slab)
Assumed thickness = 100 mm Slab TypeSlab
of Sized D
A) Dead Load no. Slab (mm) (mm)

1) Self load 0.100*25 = 2.5 KN/m2 S1 Two way Cont. 100 125
2) Finishing Loads S2 Two
Twoway
wayCont.
SS 100 125
a) Plaster (12+18mm) 20.4*0.03= 0.612 KN/m3 S3 cap slab 75 100

B) Live load DIMENSIONS OF SLAB


a) Access provided 0 KN/m2 Slab
b) Access not provided 0.75 KN/m2 no. Lx Ly
c) Water Tank 1 KN/m2 A B A B
Total 4.862 KN/m2 S1 3.6 3.6 3.62 4.8
Factored Load (F = 1.5) 7.293 KN/m2 S2 4 4 5.93 4.8
S3 2.31 3.6

LOADS ON BEAMS

Load Thick. Density Ht. (mm) Load (KN/m)

Parapet 230 mm 20 KN/m3 1000 4.6 The height of wall is obtained after deducting the beam depth.
Wall 230 mm 20 KN/m3 1150 5.29 Reactions of mid landing beam B1= 13.854 KN/m
2650 12.19 Reactions
Tri. of landing beam
Trap. B8=Parapet 7.577
Wall KN/m
Total Factored
Beam
B1 Type b D d Span Self Wt. Load Load Load Load Load Load
(Mid- mm mm mm mm KN/m KN/m KN/m KN/m KN/m KN/m KN/m
Landing) SS 230 350 300 2310 2.0125 0 0 0 5.29 21.1565 31.735

B2 Cont 230 350 300 3620 2.0125 0 5.916 4.6 0 29.2234 43.835
B3 Cont 230 350 300 4800 2.0125 0 7.354 4.6 0 37.9481 56.922
B4 Cont 230 350 300 3600 2.0125 0 0 0 12.19 14.2025 21.304
B5 SS 230 350 300 3600 2.0125 5.883 0 0 12.19 20.0855 30.128

B6 Cont 230 350 300 3600 2.0125 11.766 0 0 0 13.7785 20.668


B7 Cont 230 350 300 3600 2.0125 5.883 0 4.6 0 30.9429 46.414
B8 Cont 230 350 300 2310 2.0125 0 7.41425974 0 12.19 29.1938 43.791
B9 Cont 230 350 300 3620 2.0125 0 15.37839779 0 0 17.3909 26.086
B10 Cont 230 350 300 4800 2.0125 0 14.981 0 0 16.9935 25.49

B11 Cont 230 350 300 4000 2.0125 6.537 0 4.6 0 33.4416 50.162

B12 Cont 230 350 300 4000 2.0125 13.074 0 0 0 15.0865 22.63
B13 Cont 230 350 300 4000 2.0125 6.537 0 4.6 0 33.4416 50.162
B14 Cont 230 350 300 5930 2.0125 0 8.665 4.6 0 44.4704 66.706
B15 Cont 230 350 300 4800 2.0125 0 7.627 4.6 0 38.2211 57.332
B16 Cont 230 350 300 2310 2.0125 0 0 0 12.19 14.2025 21.304
B17 SS 230 350 300 2310 2.0125 2.808 0 0 0 19.1633 28.745
B18 SS 230 350 300 3600 2.0125 0 3.814 0 0 26.1186 39.178
B19 SS 230 350 300 3600 2.0125 0 3.814 0 0 26.1186 39.178
B20 SS NOTE:
230 IN BEAMS
350 B1 AND
300 B8, THE STAIRCASE
2310 2.0125 LOAD
2.808 IS ADDED
0 IN THE
0 TOTAL0 19.1633 28.745
AND IN THE RESPECTIVE ADJACENT BEAMS THE LOAD OF CANTILEVER SLABS ARE ADDED IN TOTAL.
CONCLUSION: THIS METHOD GIVES OUT LOWER LOADS IN BEAMS COMPARED TO EQUIVALENT UDL METHOD.
HENCE EQ. UDL METHOD IS USED FOR ANALYSIS TO ENSURE CONSERVATIVE DESIGN.

SECTION A-A
SECTION C-C
SECTION D-D
SECTION 1-1
SECTION 2-2
SECTION 3-3