3500 22 01 01 CN
3500 22 01 01 CN
The TDI operates in the RIM slot of a 3500 rack in conjunction with the M series
monitors (3500/40M, 3500/42M, etc.) to continuously collect steady state and
transient waveform data and pass this data through an Ethernet link to the host
software. (Refer to the Compatibility section at the end of this document.) Static
data capture is standard with the TDI, however using an optional Channel
Enabling Disk will allow the TDI to capture dynamic or transient data as well. The
TDI features improvements in several areas over previous communication
processors and incorporates the Communication Processor function within the
3500 rack.
Although the TDI provides certain functions common to the entire rack it is not
part of the critical monitoring path and has no effect on the proper, normal
operation of the overall monitor system. Every 3500 rack requires one TDI or
RIM, which always occupies Slot 1 (next to the power supplies).
For Triple Modular Redundant (TMR) applications, the 3500 System requires a
TMR version of the TDI. In addition to all the standard TDI functions, the TMR TDI
also performs “monitor channel comparison”. The 3500 TMR configuration
executes monitor voting using the setup specified in the monitor options. Using
this method, the TMR TDI continually compares the outputs from three (3)
redundant monitors. If the TDI detects that the information from one of those
monitors is no longer equivalent (within a configured percent) to that of the other
two monitors, it will flag the monitor as being in error and place an event in the
System Event List.
C US
Page 1 of 9
OK Relay:
Specifications
Rated to 5A @ 24 Vdc/120 Vac,
Inputs 120 Watts/600 VA Switched
Power Power.
Consumption Normally closed
10.5 Watts contacts:
Page 2 of 9
Maximum • Initiation of transient data
Current: collection based on detecting
the machine speed within
<1 mAdc, Dry Contact to Common
one of two programmable
Alarm Inhibit: windows.
Description: • The number of transient
events that can be collected
Used to inhibit all alarms in the
is only limited by the
3500 rack.
available memory in the
Maximum module.
Current:
Alarm Data
<1 mAdc, Dry Contact to Common Collection
Rack Reset: • Pre- and post-alarm data.
Description: • 1 second of static values
collected for 10 minutes
Used to clear latched alarms and
before the event and 1
Timed OK Channel Defeat.
minute after the event.
Maximum
• 100 ms static values
Current:
collected for 20 seconds
<1 mAdc, Dry Contact to Common before the event and 10
seconds after the event.
Data Collection
Keyphasor* • 2.5 minutes of waveform
Inputs: data at 10-second intervals
before the alarm and 1
• Supports the four 3500 minute collected at 10-
system Keyphasor signals. second intervals after the
The speed range support is alarm.
based on the number of
dynamic channels enabled: Static Values
Data
Number of
Minimum Speed Maximum Speed • TDI will collect the static
Channels
values including the values
1 to 16 1 rpm 100,000 rpm measured by the monitors.
17 to 24 1 rpm 60,000 rpm • TDI provides four nX static
values for each point.
25 to 48 1 rpm 30,000 rpm
Amplitude and phase are
returned for each of the
values.
• Supports multiple events per
revolution speed inputs up to Waveform
20 kHz. Sampling
Startup / • Collection of waveforms for 48
Coastdown channels.
Data • DC-coupled waveforms.
• Simultaneous Synchronous and
• Data collected from speed
Asynchronous data sampled
and time intervals.
during all operational modes
• Increasing and decreasing • User-configurable Synchronous
speed interval independently waveform sampling rates:
programmable.
Specifications and Ordering Information
Part Number 161581-01
Rev. K (02/14)
Page 3 of 9
full spectrums the channels
- 1024 samples/rev for 2 must be within a monitor
revolutions, channel pair (30 kHz
frequency span data will not
- 720 samples/rev for 2
be phase correlated between
revolutions,
channel pairs).
- 512 samples/rev for 4
revolutions, Communications
Protocols
- 360 samples/rev for 4
revolutions, BN Host
Protocol:
- 256 samples/rev for 8
revolutions, Communication with 3500
Configuration Software, 3500
- 128 samples/rev for 16
Data Acquisition Software, and
revolutions,
3500 Display Software.
- 64 samples/rev for 32
BN TDI Protocol:
revolutions,
Communication with GE’s System
- 32 samples/rev fro 64
1* Asset Management and Data
revolutions, and
Collection Software.
- 16 samples/rev for 128
Front Panel
revolutions.
Communications:
• Asynchronous data sampled
to support an 800-line RS232
spectrum at the following Protocol
frequency spans: Supported:
- 10 Hz,
BN Host Protocol.
- 20 Hz,
Baud Rate:
- 50 Hz,
115.2 kbaud maximum (auto-
- 100 Hz, baud capable)
- 200 Hz, Cable Length:
- 500 Hz, USB Cable Length: 5 meters (16.4
ft) maximum. A 3 meter (9.8 ft)
- 1000 Hz,
cable is included with the 3500
- 2000 Hz, rack.
- 5000 Hz, Connector:
- 10 kHz, USB-B
- 20 kHz, and 10Base-T /
100Base-TX
- 30 kHz.
Ethernet I/O
• Asynchronous data is anti- Communications:
alias filtered.
Ethernet, 10Base-T and
• Channel Pairs for providing 100Base-TX. Conforms to
Orbit or synchronous full IEEE802.3.
spectrum presentations can
be split among multiple Protocol
monitors. For asynchronous Supported:
Page 4 of 9
BN Host Protocol and BN TDI Operating
Protocol using Ethernet TCP/IP. Temperature:
Connection: -30 °C to +65 °C (-22 °F to +149 °F)
RJ-45 (telephone jack style) for Storage
10Base-T/100Base-TX Ethernet Temperature:
cabling.
-40 °C to +85 °C (-40 °F to +185 °F)
Humidity:
Cable Length:
95%, non-condensing
100 metres (328 feet) maximum.
Battery Life
100 Base-FX
Powered TDI:
Ethernet I/O
38 years @ 50°C (122 °F)
Communications:
Un-powered
Ethernet, 100Base-FX Fiber Optic,
TDI:
full duplex multimode. Conforms
to IEEE802.3u. 12 years @ 50°C (122 °F)
Protocol Compliance and Certifications
Supported:
EMC
BN Host Protocol and BN TDI Standards:
Protocol using Ethernet TCP/IP. EN 61000-6-2 Immunity for Industrial
Environments
EN 55011/CISPR 11 ISM Equipment
Connection:
EN 61000-6-4 Emissions for Industrial
MT-RJ Male Fiber Optic connector Environments
for 100 Base-FX cabling.
Cable Length: European Community Directives:
2000 metres (6560 feet) EMC Directive 2004/108/EC
maximum, multimode fiber optic
cable.
Electrical Safety
Note Standards:
EN 61010-1
The 3500/22M has a MT-RJ Male connector on
the unit for Fiber Optic 100 Base-FX cabling
therefore you MUST use a MT-RJ Female European Community Directives:
connector on the fiber optic cable to ensure 2006/95/EC Low Voltage
proper connectivity.
Page 5 of 9
(-4 ºF to +150 ºF) (-4 ºF to +150 ºF)
Note: When used with Internal Barrier I/O Module, refer to
specification sheet 141495-01 for approvals information.
Page 6 of 9
02 100Base-FX (Fiber Optic) 100 Base-FX Fiber Optic Cable with MT-RJ Female
Ethernet I/O module connectors
161756-AXXX
C: Agency Approval Option A: Length (in ft.) up to 1300 ft (400 m) in length:
00 None 10 ft. – 500 ft. in 10 ft. increments only
01 CSA/NRTL/C 500 ft. – 1300 ft. in 100 ft. increments
02 CSA/ATEX only
Page 7 of 9
Graphs and Figures
Page 8 of 9
Compatibility
When upgrading your 3500 rack from a 3500/20 RIM to a 3500/22 TDI, there may be 3500 M modules (e.g. 3500/40M)
that are not compatible with the 3500/22. Please check with [email protected] for additional details.
* Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company.
Page 9 of 9