Daikin One+ Thermostat Commissioning Menu Outline for Mini/multi-split (S21) equipment, v2.0.

2 software
Display
Level 1 Level 2 Level 3 Level 4 Level 5 Default only? Conditions
english
spanish (radio buttons) english
welcome french
use large font (checkbox) (disabled)
continue
unitary
single/multi-split (S21) (radio buttons) unitary
equipment type
VRV,SkyAir,single/multi-split (P1P2)
continue
(to smart thermostat setup
begin setup with 5 main steps below)
factory reset
setup
setup options run dealer demo mode
run homeowner demo mode
learn more
unitary
equipment type mini/multi-split (S21) unitary
VRV, SkyAir, mini/multi-split
(P1/P2) VRV will be supported in the future.
use wifi
1. Communication (list of available networks)
networks
search again
Only appears when "use wifi" selected
home wifi Only appears when connected to acive wifi
connected to internet
Yes network.
connected to DaikinOne Only appears if successfully connect to
Cloud Yes internet.
english
language francais english
espanol
(month, day, and year
build date set automatically when connect to WiFi.
selection)
(hour, minute, and am/pm
set automatically when connect to WiFi.
date & time selection)
use 24-hour format disabled
time zone (list of time zones) Pacific set automatically when connect to mobile app.
2. Personalization
main room
upstairs
downstairs
hallway
device name bedroom
(text entry for other) main room
kitchen
other
(other name)
fahrenheit
degree units celsius
fahrenheit
Indoor Unit: (model #)
(pick from list)
(description based on
model number) edit (text entry)
Serial #: (text entry)
Indoor Unit: (model #)
wall-mount Set automatically when model number
ceiling cassette selected from list. Default allows manual
unit type Maybe
single-flow cassette entry, also allowed if manually entered model
floor-mount number.
Outdoor Unit: (model #)
(pick from list)
(description based on model
Outdoor Unit: (model #) number)
edit (text entry)
Serial # (text entry)
3. Equipment Number of filters 1, 2 1
Setup Standard filter Do you want to remove
Remove equipment Yes/No
this equipment?
indoor air quality sensor
Add Equipment Can only add 1 of each type.
HEPA filter
Filter box
Do you want to remove Cancel
Indoor air quality sensor Remove equipment
this equipment? Continue
Number of filters 1, 2 0
HEPA filter Do you want to remove Cancel
Remove equipment
this equipment? Continue
Number of filters 1, 2 0
Filter box Do you want to remove Cancel
Remove equipment
this equipment? Continue
(date and time of error)
(code - Indoor Unit #)
Error History (error description)
(minor error code)
Clear error history? Cancel/Continue Yes/No
Temperature calibration -7°F to 7°F in 1°F steps 0°F
Calibration
Humidity calibration -15% to 15% in 1% steps 0%
4. System
EEV open degree (pulse) Emura only
Optimization
outdoor air temp Emura only
heat exchanger temp Emura only
Outdoor unit discharge temperature Emura only
Status liquid pipe temp Emura only
outdoor fan RPM Emura only
power consumption Emura only
electric current Emura only
Indoor unit indoor suction temp Emura only
therm on/off Emura only
heating: 57 to 86
min/max setpoints
57°F to 90°F 57°F to 90°F cooling: 64 to 90
Temperature setpoint
2°F to 9°F in 1°F steps 4°F
dead band:
deadband / overcool
Overcooling allowed to
0°F to 3°F in 1°F steps 0°F
dehumidify:
1, 2, 3, 4°F
cool/heat start timer diff (0.5, 1, 1.5, 2.0°C)
1°F

changeover settings

5. Preferences
cool/heat
1, 2, 3, 4°F
1°F Must be >= to start timer diff
forced changeover diff (0.5, 1, 1.5, 2.0°C)
changeover settings
Timer started on heat-to-cool or cool-to-heat
0 to 60 min. in 15 min. transition so doesn't change modes too
0
5. Preferences steps quickly. Timer is ignored if forced changeover
changeover timer diff is reached.
500 to 10,000 sf in 100 sf
house settings House size
steps
dealer information name (text entry)
phone (text entry)
email (text entry)
website (text entry)
message (text entry)
Standard filter off, 1, 2, 3, 4, 6, or 12 off if added in "add equipment"
off, 1, 2, 3, 4, 6, or 12
HEPA filter off if added in "add equipment"
reminders months
Filter box off, 1, 2, 3, 4, 6, or 12 off if added in "add equipment"
service reminder off, 3, 6, or 12 months off