Project :- Proposed BMS for SICC Project

Date :- 01 November 2018

DIGITAL POINTS ANALOGUE POINTS

DIGITAL OUTPUT DIGITAL INPUT ANALOGUE INPUT ANALOGUE OUTPUT I/O's SUMMARY
Digital Display

Duct Supply Air Temp. and Humidity

Duct Return Air Temp. and Humidity

Room Temp. & Humidity c/w display


Room Low/High Pressure Alarm
SERVICE / EQUIPMENT DESCRIPTION FOR MECHANICAL SYSTEM

AHU's/FCU's Filter Dirty Alarm

Room Temperature & Humidity

Analog Output Points


Outdoor Air Temp. & Humidity

Network Thermostat Interface


Duct Supply Air Temperature

Digital Output Points


Duct Return Air Temperature

Room Temperature set-point

Heater Curent Valve Control


Room Diff. Pressure Display
EQUIPMENT

Analog Input Points


Water Filtration Filter Alarm
Trip/Fault Alarm/AC Failure

Room Differential Pressure

High Level Chiller Interface


Low/high Fuel Level Alarm

Digital Input Points


Modulating Valve Actuator
Duct Differential Pressure
High Temperature Alarm
High Water Level Alarm
High/Low Speed Status

HEPA Filter Dirty Alarm

Low Water Level Alarm


Room Humidity Display

Start/Stop Command

Off Coil Temperature


Room Temp. Display

Water Diff. Pressure


On/Off control Valve

Low pressure alarm


Duty/Standby Mode

Gas Leak Detection

Water Temperature
Room Temperature

Digital Power Meter


Dhumidifier Control
Auto/Manual Mode

Duct Air Flow Rate

Motorised Damper
Local / BAS Mode

Room Humidity

Water Flow rate


Water Pressure
Lighting Control

Variable Speed
Valve feedback
On / Off Status

I/O's Sub-total
Occupy Mode

CO2 Sensing
Fire Alarm
Quantity
ITEM

7.0 Auditorium

7.1 AHU's & FCU's


Standard AHU for stage area
7.1.1 AHU-L4-1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 2 4 10 3 19
7.1.2 AHU-L4-2 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 2 4 10 3 19

AHU With Heat Recovery Wheel and Heat Pipes


7.1.3 AHU-L1-1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 2 4 10 3 19
7.1.4 Heat Recovery Wheel 1 1 1 1 1 1 1 0 3 3 0 6
7.1.5 Exhaust fan for Heat Recovery Wheel ( EAF-L1-1 ) 1 1 1 1 1 0 3 0 1 4
7.1.6 Fresh air booster fan ( FAF-L1-1 ) 1 1 1 1 1 0 3 0 1 4

7.1.8 AHU-L1-2 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 2 4 10 3 19
7.1.9 Heat Recovery Wheel 1 1 1 1 1 1 1 0 3 3 0 6
7.1.10 Exhaust fan for Heat Recovery Wheel ( EAF-L1-2 ) 1 1 1 1 1 0 3 0 1 4
7.1.11 Fresh air booster fan ( FAF-L1-2 ) 1 1 1 1 1 0 3 0 1 4

7.1.12 AHU-L1-3 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 2 4 10 3 19

Heat Recovery Wheel 1 1 1 1 1 1 1 0 3 3 0 6

Exhaust fan for Heat Recovery Wheel ( EAF-L1-3 ) 1 1 1 1 1 0 3 0 1 4

Fresh air booster fan ( FAF-L1-3 ) 1 1 1 1 1 0 3 0 1 4

7.1.13 FCU's (High Level Interface Thermostat) 20 0 0 0 0 0 20

7.2 Smoke Ventilaton Fans (SSF & FAF)


No monitoring by BMS is necessary. All monitoring and
control under fire fighting with remote panel at FCC.

VO (Item 1.0 - 1.3) Sub-total :- 5 0 0 5 14 14 0 14 0 0 0 5 0 0 0 0 0 0 0 0 0 5 3 0 3 0 0 5 5 0 0 3 0 0 0 0 5 10 10 0 5 5 5 11 0 5 0 20 0 0 10 47 59 21 137

Page 1 of 5 12/02/2024
ITEM

Total Point
7.0 AUDITORIUM

Digital Thermostats
Digital Power Meter
Total For Each Point Type :-
Summary of I/O points :-

Sensors and Transducers :-


EQUIPMENT
Project :- Proposed BMS for SICC Project

Damper Actuator for fresh air damper


SERVICE / EQUIPMENT DESCRIPTION FOR MECHANICAL SYSTEM

Quantity
0

Room Temp. Display

5
0
0
0

Room Humidity Display

20
0

Room Diff. Pressure Display


Digital Display

5
5

Start/Stop Command
0
0

Room Low/High Pressure Alarm


0
0

10

Lighting Control
5
5
DIGITAL OUTPUT

On/Off control Valve


14
14

On / Off Status
14
14

Trip/Fault Alarm/AC Failure


0
0

High/Low Speed Status


Flow switch
14
14

Local / BAS Mode


0
0

Auto/Manual Mode
Water Flow Sensor
0
0

Water Pressure Sensor


0

Duty/Standby Mode
Water Diff.Pressure Sensor
0
0

Water Temperature Sensor


Filter Dirty Alarm Dp switch

Occupy Mode
Float Water Level Alarm Sensor

Fuel Tank Level Sensor - Lo & Hi


5
5

AHU's/FCU's Filter Dirty Alarm


HEPA Filter Dirty Alarm Dp switch
47
0
0

HEPA Filter Dirty Alarm


DIGITAL INPUT

0
0

Low Water Level Alarm


0
0

High Water Level Alarm


0
0

Low/high Fuel Level Alarm


0
0

Water Filtration Filter Alarm


5
0
0
0
0
5

10
10
0
0

Gas Detection
0
0

Low pressure alarm


0
0

High Temperature Alarm


0
0

Fire Alarm
5
5

Off Coil Temperature


3
3

Duct Supply Air Temperature


0
0

Duct Supply Air Temp. and Humidity


3
3

Duct Return Air Temperature


0
0

Duct Return Air Temp. and Humidity


Car Park CO sensors
Air Quality (CO2) sensor
0
0

Space Humidity sensor


Duct Temperature sensor
5
5

Room Temperature
Space Temperature sensor
5
5

Room Humidity
Room Temp. & Humidity sensors
0
0

Room Temperature & Humidity


Outdoor Temp. & Humidity sensors
0
0

Duct Temperature & Humidity sensor

Room Temp. & Humidity c/w display


3
3

59

Outdoor Air Temp. & Humidity


Room Temp. & Humidity sensors c/w display
0
0

Room Temperature set-point


ANALOGUE INPUT

0
0

Duct Air Flow Rate


0
0

Duct Differential Pressure


0
0

Room Differential Pressure


ANALOGUE POINTS

5
5

CO2 Sensing

Page 2 of 5
10
10

Water Temperature
2
5
0
0
5
5
0

0
11
10
10

Water Pressure
0
0

Water Diff. Pressure


5
5

Water Flow rate


5
5

Valve feedback
5
5

Modulating Valve Actuator


11
11

Variable Speed
0
0

21

Dhumidifier Control
5
5

Motorised Damper
0
0
ANALOGUE OUTPUT

Heater Curent Valve Control


20
20

Network Thermostat Interface


0
0

Digital Power Meter


0
0

High Level Chiller Interface


10
10

Digital Output Points


47
47

Digital Input Points


137
59
59

Analog Input Points


21
21

Analog Output Points


I/O's SUMMARY

I/O's Sub-total
137
137

12/02/2024
ITEM

8.1
Date :-

8.1.1 Chillers

MSB LV2
Standard AHU

2.0 Electrical board


8.0 Auditorium BOH

8.2 AHU's & FCU's


8.1.2 Chilled Water Pumps
Air Cooled Chillers

8.3 Ventilaton Fans (SSF & FAF)


8.3.1 Auditorium storage exhaust fan
8.1.3 Chilled Water Common Header

8.3.2 Auditorium storage fresh air fan

DB Lighting for common area


EQUIPMENT

8.2.2 PFCU (High Level Interface Thermostat)


8.2.3 FCU's (High Level Interface Thermostat)
8.2.4 ACSU (High Level Interface Thermostat)
Project :- Proposed BMS for SICC Project
01 November 2018

FCU L3 Corridor, FCU Green Rm, MLDR, FLDR


8.2.1 AHU L2 Corridor, AHU CR. AHU RH1, AHU RH2
8.1.4 Chilled Water Bypass Valve + Differential Pressure
SERVICE / EQUIPMENT DESCRIPTION FOR MECHANICAL SYSTEM

VO (Item 1.0 - 1.4) Sub-total :-


2
2
2
6
4
4
1
2
3
3

31
Quantity

Room Temp. Display

Room Humidity Display

Room Diff. Pressure Display


Digital Display

2
2
4
4
3
3

18
Start/Stop Command

0
Room Low/High Pressure Alarm

10
10
Lighting Control

0
DIGITAL OUTPUT

On/Off control Valve

2
2
4
4
3
3

18
On / Off Status

2
2
4
4
3
3

18
Trip/Fault Alarm/AC Failure

0
High/Low Speed Status
2
2
4
4
3
3

18
Local / BAS Mode

0
Auto/Manual Mode

0
Duty/Standby Mode

0 Occupy Mode
DIGITAL POINTS

4
4

AHU's/FCU's Filter Dirty Alarm


0

HEPA Filter Dirty Alarm


DIGITAL INPUT

Low Water Level Alarm


0

High Water Level Alarm


0

Low/high Fuel Level Alarm


0

Water Filtration Filter Alarm


0

Gas Leak Detection


0

Page 3 of 5
Low pressure alarm
0

High Temperature Alarm


0

Fire Alarm
8
4
4

Off Coil Temperature


0

Duct Supply Air Temperature


0

Duct Supply Air Temp. and Humidity


0

Duct Return Air Temperature


0

Duct Return Air Temp. and Humidity


3
3

Fan speed/ Pump speed


8
4
4

Room Temperature
0

Room Humidity
0

Room Temperature & Humidity


0

Room Temp. & Humidity c/w display


1
1

Outdoor Air Temp. & Humidity


0

Room Temperature set-point


ANALOGUE INPUT

Duct Air Flow Rate


0

Duct Differential Pressure


0

Room Differential Pressure


ANALOGUE POINTS

6
2
4

CO2 Sensing
8
8
6

22

Water Temperature
6
6

Water Pressure
4
1
3

Water Diff. Pressure


8
3

11

Water Flow rate


8
4
4

Valve position
9
4
4
1

Modulating Valve Actuator


2
2
4
3
0

11

Variable Speed
0

Dhumidifier Control
4
4

Motorised Damper
0
ANALOGUE OUTPUT

Heater Curent Valve Control


2
6

39

Network Thermostat Interface


31
4
3
3

21
11

Digital Power Meter


3
3

High Level Chiller Interface


2
2
4
0
0
3
3

14

Digital Output Points


6
6
0
0
9
9

46
16

Digital Input Points


0
2
1
0
6

56
32
15

Analog Input Points


2
2
1
0
3
0

20
12

Analog Output Points


I/O's SUMMARY

2
0

10
12
64
21
27

I/O's Sub-total
136

12/02/2024
ITEM

Total Point
MSB LV2
2.0 Electrical board

Digital Thermostats
Digital Power Meter
Total For Each Point Type :-
Summary of I/O points :-

DB Lighting for common area


EQUIPMENT

Sensors and Transducers :-


Project :- Proposed BMS for SICC Project

1.0 Air-conditioning & Ventilation Services

Damper Actuator for fresh air damper


SERVICE / EQUIPMENT DESCRIPTION FOR MECHANICAL SYSTEM

Quantity

0 Room Temp. Display

0
0

Room Humidity Display


0

4
Room Diff. Pressure Display

21

31
Digital Display

18
18

Start/Stop Command
0
0

Room Low/High Pressure Alarm


38
20
10
10

Lighting Control
0
0
DIGITAL OUTPUT

On/Off control Valve


18
18

On / Off Status
18
18

Trip/Fault Alarm/AC Failure


0
0

High/Low Speed Status


18
18

Local / BAS Mode


Flow switch
0
0

Auto/Manual Mode
0
0

Duty/Standby Mode

Water Flow Sensor


0
0

Occupy Mode
Water Pressure Sensor
DIGITAL POINTS

Water Diff.Pressure Sensor


4
4

Water Temperature Sensor

AHU's/FCU's Filter Dirty Alarm


Filter Dirty Alarm Dp switch
58

Float Water Level Alarm Sensor

Fuel Tank Level Sensor - Lo & Hi


0
0

HEPA Filter Dirty Alarm


HEPA Filter Dirty Alarm Dp switch
DIGITAL INPUT

0
0

Low Water Level Alarm


0
0

High Water Level Alarm


0
0

Low/high Fuel Level Alarm


0
0

Water Filtration Filter Alarm


0
0

Gas Detection
4
6
0
0
0
4
0
0

Page 4 of 5
11
22

Low pressure alarm


0
0

High Temperature Alarm


0
0

Fire Alarm
8
8

Off Coil Temperature


0
0

Duct Supply Air Temperature


0
0

Duct Supply Air Temp. and Humidity


0
0

Duct Return Air Temperature


0
0

Duct Return Air Temp. and Humidity


3
3

Car Park CO sensors


Air Quality (CO2) sensor
8
8

Room Temperature
Space Humidity sensor
Duct Temperature sensor
0
0

Room Humidity
Space Temperature sensor
0
0

Room Temperature & Humidity


Room Temp. & Humidity sensors
0
0

Room Temp. & Humidity c/w display


Outdoor Temp. & Humidity sensors
1
1

77

Outdoor Air Temp. & Humidity


Duct Temperature & Humidity sensor
0
0

Room Temperature set-point


Room Temp. & Humidity sensors c/w display
ANALOGUE INPUT

0
0

Duct Air Flow Rate


0
0

Duct Differential Pressure


0
0

Room Differential Pressure


ANALOGUE POINTS

6
6

CO2 Sensing
22
22

Water Temperature
6
6

Water Pressure
1
6
0
0
0
8
0
8
4
4

Water Diff. Pressure


11
11

Water Flow rate


8
8

Valve feedback
9
9

Modulating Valve Actuator


11
11

Variable Speed
0
0

24

Dhumidifier Control
4
4

Motorised Damper
0
0
ANALOGUE OUTPUT

Heater Curent Valve Control


39
39

Network Thermostat Interface


32
11
21

Digital Power Meter


3
3

High Level Chiller Interface


14
14

Digital Output Points


46
46

Digital Input Points


136
56
56

Analog Input Points


20
20

Analog Output Points


I/O's SUMMARY

I/O's Sub-total
136
136

12/02/2024
ITEM

8.1
Date :-

8.1.1 Chillers

Standard AHU
8.0 Auditorium BOH

8.2 AHU's & FCU's


8.1.2 Chilled Water Pumps

8.4.1 Standard Exhaust Fan


Air Cooled Chillers

8.4 Other smaller exhaust fans


8.3 Ventilaton Fans (SSF & FAF)
8.1.3 Chilled Water Common Header

8.3.1 Auditorium storage exhaust fan


8.3.2 Auditorium storage fresh air fan
EQUIPMENT

8.2.2 PFCU (High Level Interface Thermostat)


8.2.3 FCU's (High Level Interface Thermostat)
8.2.4 ACSU (High Level Interface Thermostat)
Project :- Proposed BMS for SICC Project
01 November 2018

FCU L3 Corridor, FCU Green Rm, MLDR, FLDR


8.2.1 AHU L2 Corridor, AHU CR. AHU RH1, AHU RH2
8.1.4 Chilled Water Bypass Valve + Differential Pressure
SERVICE / EQUIPMENT DESCRIPTION FOR MECHANICAL SYSTEM

VO (Item 1.0 - 1.4) Sub-total :-


3
2
2
2
6
4
4
1
2
3
3

31
Quantity

Room Temp. Display

Room Humidity Display

Room Diff. Pressure Display


Digital Display

3
2
2
4
4
3
3

21
Start/Stop Command

0
Room Low/High Pressure Alarm

0
Lighting Control

0
DIGITAL OUTPUT

On/Off control Valve

3
2
2
4
4
3
3

21
On / Off Status

3
2
2
4
4
3
3

21
Trip/Fault Alarm/AC Failure

0
3 High/Low Speed Status
2
2
4
4
3
3

21
Local / BAS Mode

0
Auto/Manual Mode
0
Duty/Standby Mode
0

Occupy Mode
DIGITAL POINTS

4
4

AHU's/FCU's Filter Dirty Alarm


0

HEPA Filter Dirty Alarm


DIGITAL INPUT

Low Water Level Alarm


0

High Water Level Alarm


0

Low/high Fuel Level Alarm


0

Water Filtration Filter Alarm


0

Gas Leak Detection


0

Low pressure alarm


0

High Temperature Alarm


0

Fire Alarm
8
4
4

Off Coil Temperature


0

Duct Supply Air Temperature


0

Duct Supply Air Temp. and Humidity


0

Duct Return Air Temperature


0

Duct Return Air Temp. and Humidity


3
3

Fan speed/ Pump speed


3
4
4

11

Room Temperature
0

Room Humidity
0

Room Temperature & Humidity


0

Room Temp. & Humidity c/w display


1
1

Outdoor Air Temp. & Humidity


0

Room Temperature set-point


ANALOGUE INPUT

Duct Air Flow Rate


0

Duct Differential Pressure


0

Room Differential Pressure


ANALOGUE POINTS

6
2
4

CO2 Sensing

Page 5 of 5
8
8
6

22

Water Temperature
6
6

Water Pressure
4
1
3

Water Diff. Pressure


8
3

11

Water Flow rate


8
4
4

Valve position
9
4
4
1

Modulating Valve Actuator


2
2
4
3
0

11

Variable Speed
0

Dhumidifier Control
4
4

Motorised Damper
0
ANALOGUE OUTPUT

Heater Curent Valve Control


2
6

39

Network Thermostat Interface


31
4
3
3

10

Digital Power Meter


3
3

High Level Chiller Interface


3
2
2
4
0
0
3
3

17

Digital Output Points


9
6
6
0
0
9
9

55
16

Digital Input Points


3
0
2
1
0
6

59
32
15

Analog Input Points


0
2
2
1
0
3
0

20
12

Analog Output Points


I/O's SUMMARY

2
0

15
10
12
64
21
27

I/O's Sub-total
151

12/02/2024
ITEM

Total Point
MSB LV2
2.0 Electrical board

Digital Thermostats
Digital Power Meter
Total For Each Point Type :-
Summary of I/O points :-

DB Lighting for common area

Sensors and Transducers :-


EQUIPMENT

1.0 Air-conditioning & Ventilation Services


Project :- Proposed BMS for SICC Project

Damper Actuator for fresh air damper


SERVICE / EQUIPMENT DESCRIPTION FOR MECHANICAL SYSTEM

Quantity

0 Room Temp. Display

4
0
0

10
Room Humidity Display

31
0

Room Diff. Pressure Display


Digital Display

21
21

Start/Stop Command
0
0

Room Low/High Pressure Alarm


31
0

10
10

Lighting Control
0
0
DIGITAL OUTPUT

On/Off control Valve


21
21

On / Off Status
21
21

Trip/Fault Alarm/AC Failure


0
0

High/Low Speed Status


Flow switch
21
21

Local / BAS Mode


0
0

Auto/Manual Mode

Water Flow Sensor


0
0

Water Pressure Sensor Duty/Standby Mode

Water Diff.Pressure Sensor


0
0

Water Temperature Sensor


Filter Dirty Alarm Dp switch

Occupy Mode
DIGITAL POINTS

Float Water Level Alarm Sensor

Fuel Tank Level Sensor - Lo & Hi


4
4

AHU's/FCU's Filter Dirty Alarm


HEPA Filter Dirty Alarm Dp switch
67
0
0

HEPA Filter Dirty Alarm


DIGITAL INPUT

0
0

Low Water Level Alarm


0
0

High Water Level Alarm


0
0

Low/high Fuel Level Alarm


0
0

Water Filtration Filter Alarm


4
6
0
0
0
4

11
22
0
0

Gas Detection
0
0

Low pressure alarm


0
0

High Temperature Alarm


0
0

Fire Alarm
8
8

Off Coil Temperature


0
0

Duct Supply Air Temperature


0
0

Duct Supply Air Temp. and Humidity


0
0

Duct Return Air Temperature


0
0

Duct Return Air Temp. and Humidity


Car Park CO sensors
Air Quality (CO2) sensor
3
3

Space Humidity sensor


Duct Temperature sensor
11
11

Room Temperature
Space Temperature sensor
0
0

Room Humidity
Room Temp. & Humidity sensors
0
0

Room Temperature & Humidity


Outdoor Temp. & Humidity sensors
0
0

Duct Temperature & Humidity sensor

Room Temp. & Humidity c/w display


1
1

80

Outdoor Air Temp. & Humidity


Room Temp. & Humidity sensors c/w display
0
0

Room Temperature set-point


ANALOGUE INPUT

0
0

Duct Air Flow Rate


0
0

Duct Differential Pressure


0
0

Room Differential Pressure


ANALOGUE POINTS

6
6

CO2 Sensing

Page 6 of 5
22
22

Water Temperature
1
6
0
0
0
0
8
6
6

0
11

Water Pressure
4
4

Water Diff. Pressure


11
11

Water Flow rate


8
8

Valve feedback
9
9

Modulating Valve Actuator


11
11

Variable Speed
0
0

24

Dhumidifier Control
4
4

Motorised Damper
0
0
ANALOGUE OUTPUT

Heater Curent Valve Control


39
39

Network Thermostat Interface


21
11
10

Digital Power Meter


3
3

High Level Chiller Interface


17
17

Digital Output Points


55
55

Digital Input Points


151
59
59

Analog Input Points


20
20

Analog Output Points


I/O's SUMMARY

I/O's Sub-total
151
151