RATING: PRECAUTIONS:
ORDERING:
DESIGN PRESSURE………450 PSI at 120°F DO…read, understand and follow all instructions;
Please note that we require your
(3.1 MPa @ 49°C) failure to take every precaution will void warranty Using the chart below, please check the
membrane brand and model number
MIN. OPERATING TEMP……...………20°F and may result in vessel failure features you require and fax them with
when ordering. If this information is not
(-7°C) DO…mount the shell on horizontal members at span your purchase order to our customer
initially available, you may provide it at
FACTORY TEST PRESSURE…CE / ASME “S” using complaint vessel supports furnished; service department for expedited
a later date by checking the appropriate
675 / 585 PSI tighten hold down straps just snug processing.
box below.
(4.65Mpa) / (4 MPa) DO…provide overpressure protection for vessel set at For optional materials and/or features
BURST PRESSURE……..…………2700 PSI not more than 105% of design pressure not listed below, please consult factory
(18.6 MPa) DO…inspect end closures regularly; replace for pricing and availability.
components that have deteriorated and correct
INTENDED USE: causes of corrosion
The CodeLine Model 80E45 Fiberglass RO VESSEL LENGTH CODE – please check one
Pressure Vessel is designed for continuous, long- DO NOT… make rigid piping connections to ports or
term use as housing for reverse osmosis membrane MODEL 80E45 -1 -2 -3 -4 -5 -6 -7
clamp vessel in any way that resists growth of
elements to desalt typical brackish waters at fiberglass shell under pressure; ∆DIA = 0.02 in.
pressures up to 450 psi. Any make of eight-inch (0.5mm) and ∆L = 0.2 in. (5mm) for a length
nominal diameter spiral-wound element is easily
MEMBRANE BRAND AND MODEL – please check one and fill in
code –6 vessel
accommodated; the appropriate interfacing DO NOT… hang piping manifolds from ports or use
information
hardware for the element specified is furnished vessel in any way to support other components;
with the vessel. Please supply adapters for the following membrane brand and specific model
branch connection piping may be simply
Brand_________________________Model_______________________
supported between the header and port; maximum
The CodeLine Model 80E45 must be installed weight of branch piping; feed/concentrate – 16 lbs
operated and maintained in accordance with the (7 kg); permeate – 8 lbs (4 kg) CERTIFICATION REQUIRED
listed precautions and good industrial practice to DO NOT… operate vessel at pressures and
assure safe operation over a long service life. temperatures in excess of its rating ASME Stamped and National Board Registered (please consult factory for pricing)
DO NOT… operate vessel without permeate ports CE Marked
The high performance reinforced plastic shell must internally connected with a complete set of Standard, Certified by Pentair water.
be allowed to expand under pressure; undue elements and interconnecting hardware
restraint at support points or piping connections DO NOT… operate vessel with permeate pressure in
can cause leaks to develop in the shell. The end
EXTERIOR FINISH – please check one
excess of 125 psi at 120°F (0.9 MPa @ 49°C)
closure, incorporating close fitting, interlocking DO NOT… overtighten the connection to the
metal components, must be kept dry and free of Standard – white high-gloss polyurethane coating.
permeate port (hand-tighten plus one-quarter turn,
corrosion; deterioration can lead to catastrophic Option – optional colors are available for 50 or more vessels per order.
check for leaks)
mechanical failure of the head. Call factory for pricing details.
DO NOT… tolerate leaks or allow end closures to be
routinely wetted in any way
The end closures, incorporating close-fitting, DO NOT… pressurize vessel until double-checking to MATERIAL OPTIONS
interlocking metal components, must be kept dry verify that the retaining ring is completely inside
and free from corrosion; deterioration can lead to the groove Standard – All materials as per drawing 99112 on the first page.
catastrophic mechanical failure of the heads. DO NOT… work on any component until first Customer specified materials: -
verifying that pressure is relieved from vessel (Please consult the factory, as these options will affect pricing and vessel lead-time.)
Pentair Water will assist the purchaser in DO NOT… operate at pH levels below 3 or above 10
determining the suitability of this standard vessel
for their specific operating conditions. The final
determination however, including evaluation of the
standard material of construction for compatibility >ĞŶŶƚĞĐŚďǀ
with the specific corrosive environment, shall be
the responsibility of the purchaser.
ZŽƚƚĞƌĚĂŵƐĞǁĞŐϰϬϮŵ
ϮϲϮϵ,,ĞůĨƚ
Specifications are subject to change without notice.
dĞů͘нϯϭͲϭϱͲϮϲϭ͘Ϭϵ͘ϬϬ
&Ădž͘нϯϭͲϭϱͲϮϲϭ͘ϲϮ͘ϴϵ
www.lenntech.com
DWG. NO. 99112-L, © Pentair Water Page 2 of 2.
[email protected]