Product datasheet

Specifications

Motion controller, Modicon M262,


5ns/instruction, 4 axes, Ethernet,
Sercos
TM262M15MESS8T

EAN Code: 3606489604202

Main
Range of product Logic/motion controller - Modicon M262

Product or component type Motion controller

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
[Us] rated supply voltage 24 V DC - 15...20 %

Discrete I/O number 8

upstream connectivity IIoT-ready machine to cloud


Connected machine to plant

Complementary
Supply voltage limits 20.4…28.8 V DC

PLC Power Consumption 82 W

Inrush current 40 A

Number of overvoltage protection With

Discrete input number 4, discrete input fast input conforming to IEC 61131-2 Type 1

Discrete input voltage 24 V

Discrete input voltage type DC

Discrete input logic Sink

Voltage state 1 guaranteed >= 15 V for DC

Voltage state 0 guaranteed <= 5 V for DC

Discrete input current 7.5 mA for fast input

Input impedance 2.81 kOhm for input

Response time <= 1 µs turn-on, I0...I3 terminal(s) for fast input


<= 1 µs turn-off, I0...I3 terminal(s) for fast input
<= 1 µs turn-on, Q0...Q3 terminal(s) for fast output
<= 1 µs turn-off, Q0...Q3 terminal(s) for fast output

Configurable filtering time 0.001 ms for fast input


0.002 ms for fast input
0.005 ms for fast input
0.01 ms for fast input
0.05 ms for fast input
0.1 ms for fast input
0.5 ms for fast input
1 ms for fast input
4 ms for fast input
12 ms for fast input

Discrete output number 4 transistor fast output

Discrete output voltage 24 V DC

Discrete output current 0.5 A for fast output (Q0...Q3)

Discrete output type Transistor

29 Nov 2024 1
Discrete output logic Source

Output voltage limits 30 V DC

Maximum current per output 0.5 A with Q0...Q3 for fast output
common
Maximum output frequency 300 kHz

Accuracy +/- 0.1 % at 0.02…0.1 kHz for fast output


+/- 1 % at 0.1…1 kHz for fast output

Maximum leakage current 10 µA for output

Maximum tungsten load <1.5 W

Protection type Short-circuit and overload protection with automatic reset


Reverse polarity protection
Short-circuit protection

Reset time 200 ms automatic reset fast output

Maximum number of I/O 7TM3 IO module (local I/O-Architecture)


expansion module 7TM3 IO module (remote I/O-Architecture)
64TM3, TM5 or TM7 IO island (distributed I/O-Architecture)

Execution time for 1 KInstruction 0.005 ms

Memory capacity 32 MB for program RAM


32 MB for OS/website RAM
192 MB for system memory RAM

Data backed up 1 GB built-in flash memory for backup of user programs

Data storage equipment <= 32 GB SDHC card (optional)

Backup time 1000 h at 25 °C

Application structure 8 event tasks


4 cyclic master tasks
3 cyclic master tasks + 1 freewheeling task
8 external event tasks

Realtime clock With

Clock drift <= 10 s/month at 25 °C

Cycle time 0.5 ms

Positioning functions Libraries axes coordinated function


Libraries axes synchronous function
Sercos 3 motion bus function

Integrated connection type Ethernet/Sercos 1 with RJ45 connector and 10/100BASE-T interface
Ethernet 2 with 2 RJ45 connector and 100/1000BASE-T interface
Serial link with RJ45 connector and RS232/RS485 interface
1 encoder with female SUB-D 15 connector and RS422/SSI interface
Smart Communication Bus
TM3 IO bus
USB type mini B

Transmission rate 115 kbit/s for bus length of 15 m for RS485


115 kbit/s for bus length of 3 m for RS232
480 Mbit/s for bus length of 3 m for USB
10/100 Mbit/s for Ethernet1
10/100/1000 Mbit/s for Ethernet2

Communication port protocol EtherNet/IP adapter


EtherNet/IP scanner
Modbus TCP client/server
Modbus TCP IO scanner
Modbus TCP NVL
Ethernet RSTP
Modbus SL client/server
Modbus SL IO scanner
Modbus SL modem management
Machine Expert
ASCII manager
ASCII modem management
Sercos III master

2 29 Nov 2024
Maximum number of connected EtherNet/IP: 64
devices Modbus TCP: 64
Modbus TCP/EtherNet/IP: 96

Communication service MQTTs


OPC UA server (Encrypt)
HTTPs Methods (API)
Web server
Web visu
TLS 1.2
TLS 1.3
SNTP
NTP client/server
FTP client/server
FTPs server
SQL client (remote access)
DHCP client
DHCP server
DNS client
POP3s client
SMTP client
SNMP client/server

Local signalling 1 LED (green/red) for PWR


1 LED (green/red) for RUN
1 LED (green/red) for ERROR (fault)
1 LED (green/red) for stop forced
1 LED (green/red) for I/O error (I/O)
1 LED (green/orange) for SD card activity
1 LED (green/orange) for SL activity
1 LED (green/red) for ETH1 state
1 LED (green/red) for ETH2 state
1 LED (green/red) for EIP MS
1 LED (green/red) for EIP NS
1 LED (green/red) for Sercos

Electrical connection removable spring terminal blockfor inputs and outputs


removable spring terminal blockfor connecting the 24 V DC power supply

Product compatibility External encoder 5/24 V DC no encoder power supply

Maximum cable distance between Shielded cable: <3 m for fast input
devices Shielded cable: <3 m for fast output
Unshielded cable: <50 m for input
Unshielded cable: <50 m for output
Shielded cable: <30 m for RS485 link
Shielded cable: <15 m for RS232

Insulation Between fast input and internal logic at 550 V AC


Non-insulated between inputs
Between fast output and internal logic at 550 V AC
Non-insulated between outputs
Between input and output at 550 V AC
Between supply and internal logic at 550 V AC
Non-insulated between supply and ground

Encoder type Incremental encoder

Surge withstand 1 kV power lines (DC) common mode conforming to IEC 61000-4-5
1 kV shielded cable common mode conforming to IEC 61000-4-5
0.5 kV relay output differential mode conforming to IEC 61000-4-5
1 kV input common mode conforming to IEC 61000-4-5
1 kV transistor output common mode conforming to IEC 61000-4-5

Mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit

Height 100 mm

Depth 90 mm

Width 125 mm

Net weight 0.67 kg

Environment

29 Nov 2024 3
Standards UL 61010-1
UL 61010-2-201
CSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
CSA C22.2 No 213
ANSI/ISA 12-12-01
IEC 61131-2

Product certifications CE
cULus
cULus HazLoc Class I Division 2 CSA 22-2 No 213
RCM
EAC
Achilles
KC

Resistance to electrostatic 4 kV on contact conforming to IEC 61000-4-2


discharge 8 kV on air conforming to IEC 61000-4-2

Resistance to electromagnetic 10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3


fields 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3
1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3

Resistance to fast transients 2 kV (power lines) conforming to IEC 61000-4-4


1 kV (Ethernet line) conforming to IEC 61000-4-4
1 kV (serial link) conforming to IEC 61000-4-4
1 kV (input) conforming to IEC 61000-4-4
1 kV (transistor output) conforming to IEC 61000-4-4

Resistance to conducted 10 V 0.15...80 MHz conforming to IEC 61000-4-4


disturbances 3 V 0.1...80 MHz
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)

Electromagnetic emission Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz
conforming to IEC 55011
Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz
conforming to IEC 55011
Radiated emissions - test level: 40 dBµV/m at 30…230 kHz conforming to IEC 55011
Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500
kHz conforming to IEC 55011
Radiated emissions at 230…1000 MHz conforming to IEC 55011

Immunity to microbreaks 0.01 ms

Ambient air temperature for -20…60 °C (horizontal installation)


operation -20…50 °C (vertical installation)
-20…45 °C (flat mounting)

Ambient air temperature for -40…85 °C


storage
Relative humidity 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)

IP degree of protection IP20

Pollution degree 2

Operating altitude 0...2000 m

Storage altitude 0…3000 m

Vibration resistance 3.5 mm at 2…8.4 Hz on symmetrical rail


1 gn at 8.4…200 Hz on symmetrical rail
3.5 mm at 2…8.4 Hz on panel mounting
1 gn at 8.4…200 Hz on panel mounting

Shock resistance 15 gn for 11 ms

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 13.8 cm

Package 1 Width 18.3 cm

4 29 Nov 2024
Package 1 Length 13.1 cm

Package 1 Weight 850.0 g

Unit Type of Package 2 S03

Number of Units in Package 2 8

Package 2 Height 30 cm

Package 2 Width 30 cm

Package 2 Length 40 cm

Package 2 Weight 7.7 kg

Unit Type of Package 3 P06

Number of Units in Package 3 64

Package 3 Height 75.0 cm

Package 3 Width 40.0 cm

Package 3 Length 80.0 cm

Package 3 Weight 69.6 kg

Contractual warranty
Warranty 18 months

29 Nov 2024 5
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain
partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use
Longer, Use Again” campaign to extend product lifetimes and recyclability.

How this information helps you

Environmental footprint

Carbon footprint (kg CO2 eq,


1204
Total Life cycle)

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Packaging made with recycled


No
cardboard

Packaging without single use


Yes
plastic

Pro-active compliance
EU RoHS Directive (Product out of EU RoHS legal
scope)

SCIP Number Aee2b861-0272-4e88-8e3e-89ad0cfa3229

REACh Regulation REACh Declaration

China RoHS Regulation China RoHS declaration

PVC free Yes

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

6 29 Nov 2024
The product must be
disposed on European Union
WEEE markets following specific
waste collection and never
end up in rubbish bins

Take-back No

29 Nov 2024 7
Product datasheet TM262M15MESS8T

Dimensions Drawings

Side and Front Views

8 29 Nov 2024
Product datasheet TM262M15MESS8T

Mounting and Clearance

Correct Mounting Position

29 Nov 2024 9
Product datasheet TM262M15MESS8T

Acceptable Mounting Position

10 29 Nov 2024
Product datasheet TM262M15MESS8T

Incorrect Mounting Positions

29 Nov 2024 11
Product datasheet TM262M15MESS8T

Minimum Clearances

12 29 Nov 2024
Product datasheet TM262M15MESS8T

Connections and Schema

Encoder RS422 / 24 VDC

(1) Encoder
(2) Return Option
(3) Encoder Sub-D

29 Nov 2024 13
Product datasheet TM262M15MESS8T

Encoder RS422 / 5 VDC or Push Pull

(1) Encoder
(2) Return Option
(3) Encoder Sub-D

14 29 Nov 2024
Product datasheet TM262M15MESS8T

Encoder SSI

(1) Encoder
(2) Return Option
(3) Encoder Sub-D

29 Nov 2024 15
Product datasheet TM262M15MESS8T

Image of product / Alternate images

Alternative

16 29 Nov 2024
Product datasheet TM262M15MESS8T

29 Nov 2024 17