FULL OUTPUT COFRA 5.

2 DIM
MontP Cristiana Feliciano
PC60-13_Fogo [1] DTA

1. Profil choisi : Caracteristiques profilé


Epaisseur profil 0.75 mm
Poids profil 8.53 daN/m²
Cofraplus 60 Limite d'élasticité 350 MPa
0.75 mm Hauteur profil 58 mm
Pré-percé Largeur utile 1035 mm
Epaisseur de la dalle 130 mm

2. Données du projet

Travée L1 Coefficients de sécurité


Portée (m) 2.3 Coeff. partiel profil γM 1
Coeff. béton γC 1.5
N° du profil 1
Pondération perm. γG 1.35
Nombre d'étais 0.0
Pondération Surch. γQ 1.5
Coeff. Ψ1 0.5
Travée L1
tab_B2_td_01_kN 2.4
tab_B2_td_02_kN 5.0 Paramètres de calcul
Distrib. moment sur appui 0.3
Ponctuelle : Q(kN); a x b(mm)
Résistance au feu : REI 120 min
Essieu:Q(kN);L(m); a x b(mm) x coef dyn Limite d'élasticité armature : 500 MPa
Flèche au coulage : L/ 180
Flèche en service: L/ 500
Largeur appui interm. 120 mm

3. Matériaux rapportés Béton


Epaisseur de dalle 130 mm
Nuance béton C30/37
Chape 100 mm

Armatures complémentaires (c-dev : 10mm)


Treillis général PAF_C
S0
Calage: 38.0mm e0 25 mm
Renforts: feu+flexion Ø 14 chaque onde
S2
• = chaque onde e2 35 mm

4. Quantités - Ratios
QUANTITATIF ramené au m² de plancher donné à titre indicatif :
BETONNAGE : La mise en place du béton par pompe est recommandée. Poids total de la dalle 246.0 kg/m²
Litrage béton 95.0 l/m2
Attention !: Vérifier impérativement si les hypothèses de calcul sont conformes au Cahier des
Charges et au plan du projet Treillis général 1.25 kg/m²
Chapeau * 0.0 kg/m²
TS répartition 0.0 kg/m²
Cette information doit être transmis à tous les intervenants participant à la réalisation au
plancher collaborant. Renfort feu + flexion 5.84 kg/m²

PC60-13_Fogo [1] Tuesday 03 December 2024 p1


FULL OUTPUT

Note: Section designed according to DTA et CPT 3730_V2

Construction stage
= 0.801 <= 1.00 Deflection

= 0.917 <= 1.00 Sagging bending moment

= 0.303 <= 1.00 Reaction at end support

= -1.000 <= 1.00 Hogging bending moment

= -1.000 <= 1.00 Reaction at internal support

= -1.000 <= 1.00 Combined bending moment and support reaction

Composite slab
= 0.209 <= 1.00 Sagging bending moment

= -1.000 <= 1.00 Hogging bending moment

= -1.000 <= 1.00 Hogging bending moment at L/3 from internal support

= 0.256 <= 1.00 Longitudinal shear by partial connexion method

= 0.188 <= 1.00 Vertical shear - End support

= 0.431 <= 1.00 Vertical shear - internal support

= 0.287 <= 1.00 Deflection control

= 0.146
NOT_CONCERNED
<= 1.00 Vibration control

= NOT_CONCERNED Punching

= NOT_CONCERNED Cracking control

Fire resistance
= 0.423
NOT_CONCERNED
<= 1.00 Thermal insulation

= 0.803
NOT_CONCERNED
<= 1.00 Load bearing criterion
= NOT_CONCERNED Load bearing criterion at L/3 from internal support

= NOT_CONCERNED Free span moment - recommended checking

Note: Check imperatively whether the assumptions comply with project specifications and project
plan.

PC60-13_Fogo [1] Tuesday 03 December 2024 p2


1. Project Data
a. Profile Data: Cofraplus 60 / 0.75 mm / Pré-percé

Characteristics Values Unit


Thickness of profiled steel sheeting 0.75 mm

Self-weight of profiled steel sheeting 8.53 daN/m²

Height of profile 58 mm

Effective width of profile 1035 mm

Cross-sectional area of profile 902 mm²/m

Second moment of area of the profile 44.57 cm4 /m

Position of neutral axis of profile 33.7 mm

Sagging resistance moment of profile 4.212 kNm/m

End support reaction resistance of profile 22.184 kN/m

Internal support widths 60 / 160 mm

Maximum hogging resistance moment of profile 2.63 / 2.75 kNm/m

Maximum internal reaction resistance of profile 16.45 / 31.8 kN/m

Longitudinal shear strength of a composite slab 0.1 N/mm²

b. Composite slab
Spans:

Travée L1

Portée (m) 2.3

Static system: isostatique

Overall slab depth: 130 (mm)

Screed: 100 (mm)

PC60-13_Fogo [1] Tuesday 03 December 2024 p3


c. Construction stage
Number of spans / steel sheet:

Steel sheet L1

Number spans 1

Number of props/span:

Span L1

Number props 0.0

Note: for N>0, prop must be placed at 1/(N+1) of span

Prop width: (mm)

null 120 (mm)

PC60-13_Fogo [1] Tuesday 03 December 2024 p4


d. Reinforcement data
null

Yield strength: 500 MPa

Ductility class: B

Exposure class: XC1

Structural class: S3

Minimum cover: 25 (mm)

Calage: 15 (mm)

null 0 (mm)

null 35

null 0 (mm)

null 5

Note: overall mesh shall be continuous on support

e. Concrete data: normal / C30/37

Concrete wet self weight 25 kN/m³

Concrete dry self weight 24 kN/m³

fck 30 MPa
fctm 2.9 MPa

Ecm 33000 MPa

f. Project requirements

Shear bond method partielle

Deflection limit during construction L/ 180

Deflection limit in service L/ 500

Coefficient of moment redistribution 0.3


Coefficient mass related to live load (frequency) 0.5

Minimum frequency 2.6

Fire resistance period REI 120

Fire factor Ψf,i 0.5

PC60-13_Fogo [1] Tuesday 03 December 2024 p5


g. null

null
null Non

null > L500

null N/A

null
null Non

h. Loads acting on slab

- Uniformly distributed load

Span → L1

Permanent loads 2.4

Live load * 5.0

* unit : kN/m²

i. Partial safety factor

Material Actions
Steel sheet 1 Perm. load 1.35

Rebars 1.15 Live load 1.5

Concrete 1.5

Shearing 1.25

PC60-13_Fogo [1] Tuesday 03 December 2024 p6


2. Longitudinal section and cross-section

Longitudinal section

L1

Cross section

Profile: Cofraplus 60 / 0.75 mm / Pré-percé

Epaisseur profil 0.75 mm S0 Treillis général PAF_C

Poids profil 8.53 daN/m² e0 25 mm

Limite d'élasticité 350 MPa

Hauteur profil 58 mm

Largeur utile 1035 mm S2 Renforts: feu+flexion Ø 14 chaque onde

Epaisseur de la dalle 130 mm chaque onde e2 35 mm

PC60-13_Fogo [1] Tuesday 03 December 2024 p7


3. Details EN

IMPLEMENTATION OF THE COMPOSITE DECK: Supports, props, fasteners, openings, etc. ... shall
comply with the rules of Art, the guidance in "Prescription of technical requirements - CPT" and in
various documents of ArcelorMittal Construction

CONCRETE: The implementation of concrete by pump is recommended. Otherwise, the concrete


must be poured on the bearing elements without excessive accumulation, and immediately leveled to
the depth planned.

Poids total de la dalle 246.0 null

Litrage béton 95.0 l/m2

Treillis général 1.25 null

Chapeau * 0.0 null

TS répartition 0.0 null

Renfort feu + flexion 5.84 null

null

Note: The quantity above are given for information, more accurate values can be calculated taking
into account real conditions of the implementation on site.

PC60-13_Fogo [1] Tuesday 03 December 2024 p8


4. Construction stage

a. Loadings

Self weight of decking 8.53 daN/m²

Self weight of concrete slab 2.46 kN/m²

Construction load (working area 3mx3m) 1.5 kN/m²

Construction load (outside working area) 0.5 kN/m²

b. Deflection checking

- Maximum deflection under self weight of decking and wet concrete slab:

Steel sheet 1 2 3 4 5 6 7 8

f0 (mm) (without PEF) 9.5781

Additional weight (kN/m²) 0.168

Selfweight of slab (kN/m²) 2.628

falw (mm) (allowed) 12.777

fmax (mm) (with PEF, if any) 10.230

fmax / falw 0.8007

Unity factor: 0.801 <= 1.00 Pass

c. Sagging bending resistance check

Steel sheet 1 2 3 4 5 6 7 8

Max applied moment: MEdp 3.8642

Moment resistance: MRdp (kNm/m) 4.2120

MEdp / MRdp 0.9174

null

Unity factor: 0.917 <= 1.00 Pass

d. End support reaction

Steel sheet 1 2 3 4 5 6 7 8

Max applied reaction: REd, En (kN/m) 6.7204

Web crippling resistance: RRd, En 22.184

REd, En / RRd, En 0.3029

null

Unity factor: 0.303 <= 1.00 Pass

PC60-13_Fogo [1] Tuesday 03 December 2024 p9


e. Hogging bending resistance check

Steel sheet 1 2 3 4 5 6 7 8

Max applied moment: MEdn (kNm/m) -0.000

Moment resistance: MRdn (kNm/m) -0.000

MEdn / MRdn -1.000

null

Unity factor: -1.000 <= 1.00 Pass

f. Internal support reaction

Steel sheet 1 2 3 4 5 6 7 8

Max applied reaction: REd, In (kN/m) -0.010

Web crippling resistance: RRd, In -0.010

REd, In / RRd, In -1.000

null

Unity factor: -1.000 = 1.00 Pass

g. Interaction bending moment - reaction

Steel sheet 1 2 3 4 5 6 7 8

Max applied reaction: REd, In -0.010

Web crippling resistance: R0 -0.010

Max applied moment: MEdn -0.000

Moment resistance: M0 0.0000

MEdn / M0 + REd, In / R0 -1.000

Unity factor: -1.000 <= 1.00 Pass

5. Normal stage

a. Loadings
- Uniformly distributed loads

null

Span → 1 2 3 4 5 6 7 8

Self weight of composite slab 2.628

Additional permanent loads 2.4

Live loads (kN/m²) 5.0

PC60-13_Fogo [1] Tuesday 03 December 2024 p 10


b. Sagging bending moment
- Surface and constant line load

Span → 1 2 3 4 5 6 7 8

Applied moment (kNm/m) 9.448

Moment resistance (kNm/m) 45.234

null 0.209

Unity factor: 0.209 <= 1.00 Pass

c. Hogging bending moment

d. Hogging bending moment at L/3 from internal support

e. Longitudinal shear

Partial connexion method:


- Surface and constant line load

Span → 1 2 3 4 5 6 7 8

Applied moment (kNm/m) 9.355


Partial resistance moment (kNm/m) 36.600

Position (m) 1.036

Max unity factor MEd / MRd 0.256

Unity factor: 0.256 <= 1.00 Pass

f. Vertical shear sections/project_da 0

PC60-13_Fogo [1] Tuesday 03 December 2024 p 11


- Surface and constant line load

Max applied vertical shear

End support : VEd, En 16.432 kN/m

Internal support : VEd, In -0.010 kN/m

Vertical shear resistance:

End support : VRd, En 87.617 kN/m

Internal support : VRd, In 0.010 kN/m

Unity factor: 0.188 <= 1.00 Pass

Unity factor: -1.000 <= 1.00 Pass

g. null
- Surface and constant line load

Max applied vertical shear

End support : VEd, En 15.503 kN/m

Internal support : VEd, In -0.010 kN/m

null

End support : VRd, En 35.945 kN/m

Internal support : VRd, In 0.010 kN/m

Unity factor: 0.431 <= 1.00 Pass

Unity factor: -1.000 <= 1.00 Pass

i. Deflection checking

PC60-13_Fogo [1] Tuesday 03 December 2024 p 12


- Surface and constant line load

Span → 1 2 3 4 5 6 7 8
Deflection under total loads (mm) 1.318

Allowable deflection (mm) 4.600

null 0.287

Unity factor: 0.287 <= 1.00 Pass

k. Vibration control
Coefficient mass related to live load 0.50

Minimum required frequency: fmin 2.60 Hz

Estimated first frequency of the floor 17.813 Hz

Unity factor: 0.146 <= 1.00 Pass

PC60-13_Fogo [1] Tuesday 03 December 2024 p 13


6. Fire resistance
Required fire resistance: 120

a. Loadings
- Uniformly distributed loads:

Factor 0.5

Span → 1 2 3 4 5 6 7 8

Self weight of composite slab 2.628

Supplementary permanent loads 2.4

Live load 5.0

null kN/m²

b. Thermal insulation checking


Min required slab depth: 55.00 mm

Unity factor: 0.423 <= 1.00 Pass

c. Integrity criterion
For composite slabs the integrity criterion "E" is assumed to be satisfied (according to EN 1994-1-2).

d. Fire resistance checking

Span → 1 2 3 4 5 6 7 8

Moment resistance - hogging:

Span moment (kNm/m) 4.978

Span moment resistance (kN/m) 6.198

null 0.803

Unity factor: 0.803 <= 1.00 Pass

PC60-13_Fogo [1] Tuesday 03 December 2024 p 14


Recommended complementary checking: 0.35 free span moment

Span → 1 2 3 4 5 6 7 8

0.35 free span moment (kNm/m) 1.493

null 0.241

Unity factor: 0.241 <= 1.00 Pass

PC60-13_Fogo [1] Tuesday 03 December 2024 p 15